MODENA ES0301HCWH Electric Storage Water Heater User Manual

May 15, 2024
MODENA

MODENA ES0301HCWH Electric Storage Water Heater

IMPORTANT SAFETY INFORMATION

General Remark
The installation and maintenance has to be done by qualified professionals or authorized technicians of MODENA. MODENA is not responsible for any damage or malfunction caused by wrong installation or the failure of following instructions that are included in this manual book. For more information regarding to installation and maintenance guidelines in details, please refer to below chapters.
Caution
Before installing this electric storage water heater, check and ensure that the power socket is properly functional and reliably grounded. Otherwise, the electrical storage water heater cannot be installed and used. Do not use an extension cord if there is a problem with the power socket. Incorrect installation and use of this water heater may result in serious injuries and loss of property.

Special Caution

  • If the supply cord is damaged, it must be replaced by MODENA technicians, MODENA service agent or similarly qualified persons in order to avoid a hazard.

  • The power socket must be earthed (grounded) reliably. The rated current of the socket should not be lower than 16A. The power socket and the power plug should be kept dry to prevent electrical leakage.

  • The installation height of the power socket should not be lower than 1.8 m.

  • The wall in which the electrical storage water heater is installed should be able to bear the twice bigger load than the weight of this water heater filled fully with water without distortion and cracks. Otherwise, other strengthening measures should be adopted.

  • The pressure relief valve that is attached with the water heater must be installed at the cold water inlet of this appliance (see Picture 1), and make sure it is not exposed in the foggy. The water may be out-flowed from the pressure relief valve, so the outflow pipe must be opened wide towards the air. The pressure relief valve needs to be checked and cleaned regularly to avoid blockage.

  • When using this water heater for the first time (or for the first use after maintenance), this heater cannot be switched on until it has been filled fully with water. When filling the water, at least one of the outlet valves of the water heater must be opened to exhaust the air. This valve can be closed after the water heater has been filled fully with water.

  • This appliance (water heater) is not intended to be used by persons with special needs for their physical, sensory or mental capabilities, or lack of experience and knowledge (including children), unless they have been given the supervision or instructions concerning the use of the appliance by a person who responsible for their safety. Children should be supervised to ensure that they are not playing with this water heater.

  • During the heating process, there may be drops of water dripping from the pressure relief hole, and this is a normal case. If there is an over-leaking, please contact MODENA Customer Care for repair. This pressure relief hole should not, under any circumstances, be blocked; otherwise, the water heater may be damaged, even resulting on accidents.

  • The drainage pipe that is connected to the pressure relief hole must be kept sloping downwards.

  • Since the water temperature inside the heating tank can reach up to 75oC, the hot water must not be directly flowed to human skin at the initial use. Adjust the water temperature in accordance to human skin endurance to avoid scalding.

  • If the flexible power supply cord is damaged, the special power cord provided by MODENA must be selected, and replaced by MODENA maintenance personnel (technician).

  • If any parts and components of this electrical storage water heater are damaged please contact MODENA Customer Care for repair.

  • In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must be not supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.

  • For the correct operation of the appliance, it is necessary to pay attention that the maximum inlet water pressure is 0.8 MPa, and the minimum inlet water pressure is 0.015 MPa.

  • When the water pressure is over 0.8 MPa, this will be automatically activated the safety valve, and the water may drip from the discharge pipe of the pressure-relief device (see Picture 2). Therefore, this pipe must be left open towards the air (atmosphere). The pressure-relief device should be operated / activated regularly to remove limestone deposits and to avoid blockage in the pipes.

  • Draining away the water inside the inner tank can be done from the pressure relief valve. Twist off the thread screw of the pressure relief valve and lift the handle of the drainage pipe valve upwards (Picture 3). Every drainage pipe that connected to the pressure-relief device must be installed in a continuously downward direction and in a frost-free environment.

PRODUCT INTRODUCTION

Nomenclature (The Terms to Classified Product Types and Names)

  • ES XXXX HD
  • ES = the product code of the electric storage water heater;
  • XXXX = capacity (L) and water heater type;
  • HCWH = water heater series;

Technical Performance Parameters

Rated Volume 30 L, 50 L, 80 L, 100 L
Rated Voltage 220V
Rated Pressure 0,75 MPa

Frequency

| 50Hz
Rated Water

Temperature

| 75 oC| Heating

Efficiency

| >90%
Water-proof Degree| IPX4| Structure Mode| Penyimpanan Air Tipe Tertutup

Hementik

Brief Introduction of Product Structure
ES XXXX HCWH

INSTALLATION

Installation Instruction

  1. The heating machine must be installed on a solid wall. If the wall is not able to withstand a load of 2 times the heating load, a special support must also be installed.
  2. Before determining the position of the bolt holes, you must ensure that the right side of the water heater is more than 200 mm (0.2 m) from the floor, so that there is a place for repairs when needed.
  3. Determine the 2 positions to install the expansion bolt with hook according to the instructions below, then hang up the water heater:

MODENA-ES0301HCWH-Electric-Storage-Water-Heater-fig-5

  1. The power supply must have good quality and adopts the mono-phase tri-pole that complies with the corresponding standard. Also, the power supply must suitable with the ground line where it must be installed properly in a high position and not easily splashed by water.

  2. Install the power plug to the power socket on the wall. The power supply for this appliance must be around 220 V. It is recommended to place the power socket on the right above the water heater. The height of the socket to the ground should not be less than 1.8 m (see Picture 6). If there is problem on the power cord, the cord should be replaced by MODENA agents or qualified person who is able to do the replacement and repair so as to ensure the safety.

  3. If the size of the bathroom is too small, the water heater can be installed at another place. However, the water heater should be installed closely to the stand-point of hot water use (bathroom) to optimize the heat of the water.

Plumbing Connection

  • The dimension of each used pipe is G1/2 (”BSP ½”). The maximum and minimum pressures of the water inlet should use Pa (Bar) as the unit.
  • Connect the pressure relief valve to this water heater on its water inlet.
  • In order to avoid leakage when connecting the plumbing, the rubber seal gaskets that provided with this water heater must be added at the end of the threads to ensure the connection is leak-proof (see Picture 7).

MODENA-ES0301HCWH-Electric-Storage-Water-Heater-fig-7

NOTE
Please be sure to use the accessories provided by MODENA to install this electric storage water heater. This electric storage water heater cannot be hung on the bracket until it has been confirmed to be firm and reliable. Otherwise, this water heater may drop off from the wall, resulting to its damage, even serious accidents of injury to the user.

HOW TO USE

Operating Procedure

  • Check all the piping connection to avoid the leakage before turning on this electric storage water heater.

  • Open one of the outlet valves of the water heater, then, open the inlet valve .to get the water heater filled with water.

  • When the water flows out of the outlet pipe, it implies that the water heater has been filled fully with water, and the outlet valve can be closed.

  • Make sure that the tank is fully filled up with water; otherwise, it will damage the heating elements.

  • During normal operation, the water inlet valve should always kept open.

  • Insert the power plug into the power socket and check the reliability of the leakage protection device (ELCB). Press the testing button, the indicator light on the power plug should be off, and the reset button should bounce up; then push down the reset button, the indicator light will turns on to verify that the leakage protection works well (see Picture 10). If the reset button cannot be pressed during the use, the leakage protection device (ELCB) might be error or fails to work; If the reset button is pressed down and bounce up again, then it shows that the power circuit leaks or the the power supply is disconnected.

  • If the indicator lights turn on, the thermostat will automatically control the temperature. When water temperature inside the heater has reached the set point, water heater will switch off automatically. When water temperature falls below the set point, water heater will be turned on automatically to restore the heating.

Operating the Water Heater

  • Rotate the knob according to the marking (indicator) to increase or decrease the temperature setting.
  • Rotate the power controller knob to the position Min, Mid, or Max, and the water heating process starts.
  • The water heater needs to be turned on for a certain period of time to reach the desired (set) temperature.
  • During the heating process, it is normal to see the slight drip at the safety valve. Please do not cover the hole of the safety valve outlet.
  • Connect the outlet hole to a drainage pipe. The water may drip from the drainage pipe of the safety valve; therefore, this pipe must be exposed to the atmosphere (air)
  • The safety valve has to be operated regularly (preferably at least every six months) to remove the limestone deposit and to ensure that it is not blocked.

Function Introduction

  • Temperature dial function displays actual temperature and temperature setting.
  • Heating function: within 30oC to 75oC to set the heating temperature.
  • Safety function: with anti-dry protection, overheat protection to keep safe when using.

MAINTENANCE

General Instruction
WARNING!

Do cut off the power supply before do the water heater maintenance to avoid the danger of electric shock.

  • Check the power plug and the power socket as often as possible. Electrical contact must be secured and also must be provided proper grounding The power plug and the power socket must not heat excessively.
  • If the water heater is not used for a long time, especially in regions with low air temperature (below 0 oC), it is necessary to drain the water from the heating tank to prevent damage of the water heater due to the water-freezing in the internal tank. Refer to the “Important Safety Information” part in this manual book for the method of draining away the water from the internal tank
  • To make the water heater operation durable, it is recommended to regularly clean the internal tank and remove deposits in the heating element of the water heater. Also, check the condition of the magnesium anode (whether fully decomposed or not), and if necessary, replace it with a new one in case of full decomposition. Tank cleaning frequency depends on the hardness of the water in each location where this water heater is applied. Cleaning must be performed by MODENA or special maintenance services.

Tank Cleaning
After having been used in a long time, the tank of the water heater will have the dirt in it and therefore must be cleaned according to these steps:

  1. Turn off the power supply.
  2. Close the cold water valve.
  3. Open the hot water valve.
  4. Open the pressure relief valve (if used).
  5. Flush / rinse the tank with cold water.
  6. Repeat this process several times until the tank is completely clean.

Safety Valve Cleaning
Safety valves should be cleaned regularly to prevent any dirt that clogs the valve:

  1. Remove the safety valve, then clean and wash it.
  2. Check if the parts of the valve are still able to move well.
  3. After cleaning the valve, install the safety valve back to its position by first giving the seal tape around the end of valve.
  4. Fill the water heater with water after the pipes are refitted.

Magnesium Anode
Magnesium Anodes functions to neutralize the corrosive substances in the water and will run out in a certain time depending on the corrosive properties of the water. If the water has good enough quality (PAM), magnesium anode should be replaced within 2 (two) years. If the water quality is not good, magnesium anodes should be replaced 1 (one) year. To replace the magnesium anodes, contact MODENA Customer Care.

Heating Element
If the water contains lime (mud), the heating element cannot function properly (slow heat) because it was covered by a crust of lime (mud). Therefore, the heating element must be cleaned of each year. Contact MODENA Customer Care for cleaning.

PENYELESAIAN MASALAH

Check the things below before contacting MODENA Customer Care in the moment of operation disturbance:

Problem Possible Cause Recommended Action
Heating indicator light is off. Failures on the temperature controller.

Contact MODENA Customer Care for repair.

Power indicator light is off.

| 1.    Power source is not connected or badly connected

2.    Indicator light is damaged

3.    Overheating sensor is activated.

|

Contact MODENA Customer Care for repair.

---|---|---

No water flows out from hot water outlet.

|

1.    Water supply is cut off

2.    Water pressure is too low

3.    Water Inlet valve is not opened.

| 1.     Wait for the restoration of water supply.

2.     Use the water heater again when the water pressure is increased.

3.     Open the water inlet valve

of.

Water is not warm enough.

|

1.    Heating element is not active.

2.    Temperature controller is malfunction.

3.    No power supply to the water heater.

| 1.     Replace the heating element and contact MODENA Customer Care for repair.

2.     Contact MODENA

Customer Care for repair.

3.          Check the power supply.

Water temperature is too high.| Failures on the temperature control system.| Contact MODENA Customer Care for repair.

Water leak

|

1.    Trouble on the seal for each connected pipes.

2.    Leaking at the piping connection

3.    Leaking at the gasket

| 1.     Seal up the piping connection.

2.     Tighten the connection.

3.     Tighten the element or replace the gasket and Contact Customer Care for

repair.

DISPOSAL OF USED PRODUCT

This symbol on the product or in its packaging indicates that this product must not be treated as household waste. Instead, it should be taken to the appropriate waste collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by the inappropriate waste handling of this product. For more detailed information about the recycling of this product, please contact your local council or your household waste disposal service
layanan pembuangan sampah rumah tangga Anda.

SPECIFICATIONS

Model ES 0301 HCWH ES 0501 HCWH ES 0801 HCWH ES 1001 HCWH
Type Tank (Storage)
Installation Horizontal
Heat Source Electricity

Heating Tank

Material

| Steel
Heating Tank

Coating

| Enamel coated steel
Temperature Setting| Yes
Power Selection| Yes
Temperature Display| Yes
Electric Safety

(ELCB)

| Double
Overpressure Safety| Yes
Anti-rust| Magnihealth +
Capacity| 30 L| 50 L| 80 L| 100 L
Rated Power| 500 W| 1000 W| 1000 W| 1500 W
Water Pressure| 0.015 – 0.8 Mpa
Water Pipe

Diameter

| 0.5 Inci
Temperature| Maksimum 75 oC
Product Dimension| Ø355515 mm| Ø390645 mm| Ø440775 mm| Ø440925 mm
Product Weigt| 11,3 kg| 14,4 kg| 22 kg| 25,8 kg

Specifications of this appliance may change without notice to improve the quality of the product. Pictures in this manual are schematic and may not match your product exactly. Values stated on the machine labels or in the documentation accompanying it are obtained in laboratory in accordance with the relevant standards. Depending on operational and environmental conditions of the appliance, values may vary.

APPENDIX: WIRING DIAGRAM

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals