MEIYA H7 High Precision Scale Instruction Manual
- May 15, 2024
- MEIYA
Table of Contents
MEIYA H7 High Precision Scale
Specifications:
-
Product Name: H7 Weighing Scale
-
Functions: Calibration, Sample confirmation, Unit switching,
Zeroing and Tare function -
Power Supply: [Toggle switch] on the bottom right side of the scale
Product Usage Instructions
PCS Function:
- If a sample has been taken before, press [MODE] to switch directly to PCS mode.
- If you need to resample:
- Press and hold [SMPL/SURE] to reselect the number of samples.
- While counting, press [MODE] to exit.
No Sample Taken Before:
- Press [MODE] to switch to PCS mode.
- Screen will display SP 10.
- Press [CAL] to select the value (10/20/50/100/200/500).
- Place the object, press [SMPL/SURE] to confirm and proceed.
Tare Function:
- Place an empty container on the scale.
- Hold [ZERO/TARE] for a few seconds until the screen shows 0.
- Place the items to be weighed in the container.
Calibration:
- Press and hold [CAL] for 4 seconds to enter calibration mode.
- Select calibration weight value (single-point arbitrary value or 3-stage calibration).
- To change calibrated weight value:
- Press [SMPL] to move the digit.
- Press [Zero/Tare] to change the digit size.
- Press [MODE] to confirm the calibration weight value.
- Place the weight and press [Zero/Tare] to complete calibration.
Frequently Asked Questions (FAQ):
-
Q: What should I do if the scale displays [-Erro-]?
A: If the weight is zero or negative, [-Erro-] will be displayed. Return to select the number of samples. -
Q: What does [-SLAC-] mean?
A: If the single weight is less than 50% of the index value, [-SLAC-] will be displayed before entering the PCS mode. -
Q: How do I reset the tared value of a container?
A: When all weight is removed from the weighing tray, the tared value of a container will be displayed as a negative number. Press [ZERO/TARE] again to return the scale to zero.
Thank you for purchasing the H7 weighing scale. Please read all operating instructions carefully before use. This weighing sale is a precision instrument. With proper use method, it will provide years of reliable service. Never load the scale with more than the maximum capacity. Although the H7 is extremely durable with extra overload protection design, overloading will permanently damage it!Place your scale at room temperature and keep the surrounding environment clean; extreme temperatures, dust, dirt, moisture, vibration, air currents or close proximity to other electronic equipment will all cause an adverse effect on the reliability and accuracy of your scale. The scale has delicate sensors and is easy to be affected, so handle the scale with care, avoid stress or violent vibration. Though our scale has shock- resistant design, there is no way to achieve complete protection. The damage due to the above reasons is not within the scope of warranty. If you have any problems, contact with us , our after-sale service email is YONCON_Services@outlook.com , we are glad to solve any your problems at anytime.
Button Descriptions.
[CAL]: Calibration function
[SMPL/SURE]: Sample function, confirm sampling number
[MODE]: Switch units and PCS (kg/g/lb)
[ZERO/TARE]: Zeroing and tare function
[Toggle switch]: turn on or off. The switch is on the bottom right side
of the scale
POWER SUPPLY
Accumulator battery:
The scale is powered by accumulator battery, and not removable. You can
disassemble and replace the accumulator battery by yourself if you have
professional equipment. Please remember to contact us if you have any
questions.
Power Adapter:
The scale can be powered by AC/DC Adaptor. The package includes an AC/DC
Adaptor, so you can use the scale with the adaptor connected to a power
source, or you can charge the scale with the adaptor. We recommend using a 6v
or 7v adapter, too many volts can easily have an adverse effect on the scale.
OPERATION INSTRUCTIONS
PCS Function:
This function is mainly used to calculate the number of products of the same
weight.
- If the sample has been taken before, press the [MODE] to switch directly to the PCS mode.
- If you need to resample, press and hold the [SMPL/SURE] to reselect the number of samples.
- While counting, press the [MODE] to exit.
- If no sample has been taken before, press the [MODE] to switch to PCS mode and the screen will display SP 10.
- Press the [CAL] to select the value 10/20/50/100/200/500, place the object, press the [SMPL/SURE] to confirm and go to the next step.
- When the number of samples is being selected, you can press [MODE] to exit.
Notes: If the weight is zero or negative, [-Erro-] will be displayed and
then return to select the number of samples.
If the single weight is less than 50% of the index value, [-SLAC-] will be
displayed before entering the PCS mode. If the sampled weight is less than 40
divisions, [-CSL-] will be displayed and then enter the PCS mode.
Tare Function:
Tare function can be used for eliminating the weight value of an empty
container. Place an empty container on the scale and hold on [ZERO/TARE] for a
few seconds until the screen shows “0”. Then place the items to be weighed in
the container.
NOTE: When all weight is removed from the weighing tray, the tared value
of a container will be displayed as a negative number. Press [ZERO/TARE] again
to return the scale to zero.
CALIBRATION
- Press and hold the [CAL] for 4 seconds to enter calibration mode and display ——
- Press the [Tare] to take the calibration zero point and display -CAL-
- Selecting the calibration weight value, flashing the calibration weight value or 3-stage calibration paragraph 1.
Single point arbitrary value: display a number 3-segment calibration method: display a number and CAL
- Press the [CAL] to select 2 types of calibration: single-point arbitrary value calibration, 3-stage calibration.
- If single point arbitrary value calibration is selected (last calibration value is displayed at the beginning)
- If you do not need to change the calibration weight value, place the weight and press the [Zero/Tare] to complete the calibration.
- If the calibrated weight value needs to be changed.
- Press [SMPL] to move the digit (starting from the highest digit), the current digit being changed flashes.
- Press [Zero/Tare] to change the current digit size.
- Press [MODE] to confirm the calibration weight value and enter flashing the whole calibration weight value.
- After confirming the calibration weight value, place the weight and press [Zero/Tare] to complete the calibration.
- If the 3-stage calibration is selected, the 3 stages are fixed to the maximum weighing value: 1/3, 2/3, full range, not changeable.
- Press [ZERO/TARE] to take the first calibration weight value, loading the first segment weight, after the value is taken, the second weight value will be displayed flashing.
- Load the second segment weight and take the calibration weight value automatically, after finishing, the third segment weight value will flash.
- Load the third segment weight, automatically take the calibration weight value, after completion, return to weighing.
SPECIFICATIONS
SPECIFICATIONS
LCD Display| ¨Yes ¨No| Units| kg, g, lb
Capacity| ▢10kg/0.1g ▢15kg/0.5g ▢30kg/1g
Scale Dimension| 9.09″(23.1cm)10.51″(26.7cm)4.01″(10.2cm)
Tray Dimension| 8.5″(21.6cm)*6.57″(16.7cm)
Power Source| Accumulator Battery / Adapter – DC 6V
Operating Temperature| Optimum 10-40℃ (50-104°f)
Customer Service| Within two years
After-Sale Service Email|
YONCON_Services@outlook.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>