AquilaPro KL01 Laser Measuring Tool
Product Information
Specifications:
- Laser receiving lens
- Laser emission port
- LCD display
- Main button
- Shut down button
- Function button
- Lanyard hole
- Charging port
Product Usage Instructions
Basic Operations
On/Off:
To turn on the device, press the main button for 0.5 seconds. To shut down,
press the shut down button for 2 seconds.
Switching Front/Rear Reference:
In the power-on state, press the function button for about 1 second to
switch the reference between front and rear. Note: Do not switch the reference
during measurement.
Switch Numerical Unit:
In the shutdown state, press and hold the main button to turn on the
device. Wait for about 2 seconds to enter the unit switching state. The unit
can be switched between meters (m), feet (ft), and inches (in).
Other Operations:
Return Operation:
Press the shutdown button for about 0.5 seconds to return to the previous
level of data or mode.
LCD Backlight Control:
Long press the main button for about 1 second to turn off/on the LCD
backlight.
Simple Measurement:
Single Measurement:
When powered on, press the main button for about 0.5 seconds to turn on the
red measurement laser.
Advanced Function Operation:
Switch Function Mode:
When powered on, short press the function button for about 0.5 seconds to
switch the function mode.
Area Measurement:
In this mode, you can measure and automatically calculate the area. Press the
main button to measure data (1), then press again to measure data (2). The
meter will display the calculated area.
Volume Measurement:
Similar to area measurement, in this mode, you can measure and calculate
volume by taking multiple measurements.
Primary Pythagorean Mode:
This mode uses the Pythagorean law to calculate measurements automatically.
Short press the main button to measure data c, and press again to measure data
b. The meter will calculate data a based on these measurements.
Frequently Asked Questions (FAQ):
Q: Can I switch the reference during measurement?
A: No, the reference should be selected before starting or after
finishing a single measurement.
Q: How do I change the numerical unit?
A: Switch between meters (m), feet (ft), and inches (in) by pressing and
holding the main button after turning on the device.
Q: How do I perform area measurements?
A: Press the main button to take measurements (1) and (2) for area
calculation in area measurement mode.
Interface
Item | Description |
---|---|
1 | Laser receiving lens |
2 | Laser emission port |
3 | LCD display |
4 | Main button |
5 | Shut down button |
6 | Function button |
7 | Lanyard hole |
8 | Charging port |
Operating Instructions
-
Do not look directly at the red laser light emitted from the laser-emitting port with your eyes. Looking directly at it will cause damage to your eyes.
-
Do not cover the receiving lens and laser emitting port of the rangefinder when measuring the distance, and place the rangefinder on a fixed baffle or bracket plane as much as possible.
-
During measurement, the rangefinder cannot be moved before the measurement result is displayed on the software interface.
-
The better the laser’s throwback (scattering, non-reflection) effect on the target surface, the farther its range. When the laser spot falls on the surface of the following objects, the measurement will be inaccurate:
-
Transparent surfaces (water, glass).
-
Surfaces that reflect surfaces(polished metals)
Porous surfaces (e.g. soundproof materials) -
Textured surfaces (e.g. rough plaster walls, natural stone).If necessary, reflective target paper (e.g. white paper) can be placed on top of these objects.
-
-
Front/Rear reference: means whether the body length is counted in the measurement data of both ways.
Front datum: Without fuselage length.
Rear reference: Include fuselage length
Basic operation
-
On/Off
- Press the main button 0.5S to turn on
- Press the shut down button 2S to shut down.
-
Switching front/rear reference
In the power-on state, press the function button for about is to switch the reference.
Note: The selection of the reference should be before the start of the measurement or after the end of a single measurement.
Do not switch the reference during the measurement process. -
Switch numerical unit
In the shutdown state, press the main button and turn it on and keep the keys on, wait for about 2s after turning on the device to enter the measurement numerical unit switching state.The unit can be switched between m (meter)/ft (feet)/in (inch) in turn. -
Other operations
- Return operation Press the shut-down button for about 0.5s to return to the previous level of data or mode.
- LCD backlight control Long press the switch button for about 1s to turn off/on the LCD backlight.
-
Simple measurement
-
Single measurement
When power on, press the main button for about 0.5s and turn on the red measurement laser.Short press again to start the measurement and display the data.
lf no operation, the laser will be automatically turned off after15s and meter will be automatically turned off after 60s. -
Consecutive measurement Long press the main button for about 1s to enter the consecutive measurement mode.In the process of moving the meter toa new position, the real-time distance measurement data will be displayed on the screen.Under consecutive mode, the meter will automatically display the maximum and minimum value of the measured data.
-
Advanced function Operation
Switch function mode: When power on, short press the function button for about 0.5s to switch the function mode, and press once to switch one function mode.
Area measurement
In this mode, the area can be measured and automatically calculated.Short
press the main button to measure the data (1), and then short press to measure
the data (2). The meter will automatically work out the area based on these 2
measurements and display it on the primary display area.
Area measurement symbol:
Volume measurement
In this mode, the volume can be measured and automatically calculated.
Short press the main button to measure data (1), short press again to measure
data (2), and short press again to measure data (3).
The meter will automatically work out the volume based on these 3 measurements
and display it on the primary display area.
Volume measurement symbol:
Primary Pythagorean
In this mode, the system uses the Pythagorean law a2+b2=c2, The third side
measurement data is automatically measured by the two side measurement data.
This mode can calculate the length of the target edge only by running the
Pythagorean law once, which is also called Primary Pythagorean mode.
Short press the main button to measure data c, and press again to measure data
b. After measuring the two data, the meter automatically calculates the length
of data a.
Primary Pythagorean symbol:
The position of laser distance meter is shown as below.
Secondary Pythagorean (data addition)
This device can measure height in two segments by taking three measurements. Press the operation key to get the data c, data b and data e, the laser automatically calculates the length of data (a1+a2).
Secondary Pythagorean symbol (data addition):
Secondary Pythagorean (data subtraction)
This device can measure height in two segments by taking three measurements. Click the operation key to get the data e, data b and data c, the laser automatically calculates the length of data a.
Secondary Pythagorean (data subtraction):
(Optional-only the model with tilt senser) One-key angle height measurement
In this mode, the system uses the built-in angle sensor and uses the Pythagorean law to measure, short press the key to measure the length D, the angle θ, shortest distance a and object height b can be measured by one key.
Primary Pythagorean and Angle measurement symbol:
Screen display Interface
Safety information
- Please don’t look into the beam directly. The laser project a class 2 laser (620-670nm, <1mW) that meets IEC 60825-1standar.
- Please place it in the area out of the reach of children.
- Don’t use this instrument in a flammable or explosive environment
- Don’t use this instrument near medical equipment or on the air
- The meter parts mush keep clean at any time, Please turn it off before clean it. When there is dust on the laser emitting port and the receiving lens, use a soft cloth with cleaning water or a neutral screen cleaner, then wipe it. Do not use acid or alkaline detergents for cleaning; as well, do not use alcohol or other solvents for cleaning.
- The meter is not waterproof, and it cannot be wetted or placed in water.
- Do not repair this instrument without permission. If the instrument is damaged, please contact your supplier.
- Please dispose of disused instruments in accordance with the laws of your location.
Problems and Solutions
Fault type | Possible causes and solutions. |
---|---|
Unable to turn on | No battery power, charge and then try to turn on. |
No display | 1. Turn off the backlight, short press shut down button for about |
1s to turn on/ off the backlight.
2. The display is damag- ed, please contact the supplier to solve.
---|---
Unable to charge| 1. The charging cable is damaged, replace the charging
cable to try to solve.
2. The charging module is damaged, please contact the supplier to solve.
Large error| 1. Add white reflector for harsh environment.
2. Fix calibration accuracy in setting page.
3. The ambient temperature is too low/high, please warm up/cool down the equipment.
No data
| 1. Laser receiving / emission port defacement, clean treatment.
2. The meter shake too much, please rest.
Specification
Item | Laser distance meter |
---|---|
Measuring range (general conditions*) | 0.03–30/40/50m (according to the actual |
selected equipment)
Measuring accuracy| ±2mm
Measuring range (unfavorable conditions*)| 0.03-20/30/40M (according to the
actual selected equipment)
Measuring accuracy (unfavorable conditions)|
±3mm
Display Unit
Minimum
|
1mm
Laser type| 620~670nm, Class2 ,<1mw
Battery life| 250mAh 5000 measurements (approx.)
Charging| DC 5V<1A
Operation Temperature| 0°-40°C
Storage| -20°-60°C
Relative air
humidity
| 80%
General conditions
Refers to the strong reflection ability of the laser irradiation area (such as
painting a white wall), the background lighting is dark and the working
temperature is 15-35°C. under this conditions, an error
±0.05 mm/m should be considered.
Unfavorable conditions
Refers to the weak reflection ability of the laser irradiation area (such as
black cardboard polished tiles), strong background lighting and working
temperature is <0°C or 45°CUnder this conditions, an error ±0.15 mm/m should
be considered.
Measuring range
When measurement under the laboratory environment (5 meters distance, 300LX
brightness), the times of the measurement, there will be deviation about ±500.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>