Hotpoint AH12H07D2B Electric Heater Heat Pump User Guide
- May 15, 2024
- Hotpoint
Table of Contents
Hotpoint AH12H07D2B Electric Heater Heat Pump
Product Information
Specifications
- Model: AH12H07D2B
- Heater Watts: 2580/2150
- Heater BTU: 7800/6300
- Heater Amps: 11.3/10.3
- Heat Pump Watts: 485/465
- Heat Pump BTU: 6200/6000
- COP: 3.6
- Voltage: 230/208 V
roduct Usage Instructions
Dimensions and Installation Information
Wall Case Dimensions:
A: 30 inches
C: 70 inches
Maximum Cord Extension: 30 inches
Wall Opening Dimensions: Add 1/4 to A and C dimensions for all cut-outs.
RAB80 16-1/4 Min. H x 42-1/4 Min. W
AH12 Electric Heater
- Line Cord Connected Units
- Min Circuit: 15
- Recommended Protective Device: 15 amp time-delay fuse or breaker
AH12 Heat Pump
- Heat Pump Specifications:
- COP: 3.6
FAQ
Q: What is the recommended circuit for the AH12 Electric Heater?
A: The recommended circuit for the AH12 Electric Heater is a minimum of 15 amps with a time-delay fuse or breaker.
Q: What are the dimensions of the wall case for installation?
A: The wall case dimensions are A: 30 inches and C: 70 inches. Additionally, add 1/4 inch to A and C dimensions for all cut-outs.
Hotpoint® PTAC Heat Pump Unit with Electric Heat Backup 15 amps, 230/208 Volt
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRICAL WIRING
- All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.
NOTE: Aluminum wiring may pose special problems – consult a qualified electrician.
GRILLE OPTIONS
- Stamped Aluminum Grille – RAG70
ELECTRICAL CONNECTION
- 230/208 volt units must be plugged into a receptacle. Installation must comply with local electrical codes and regulations.
- Power cord is permanently attached on all Hotpoint chassis
Specifications
AH12 ELECTRIC HEATER
230/208 VOLT| LINE CORD CONNECTED UNITS
Heater Watts| 2580/2150
Heater BTU| 7800/6300
Heater Amps| 11.3/10.3
Min Circuit| 15
Recommended protective Device| 15 amp time-delay fuse or breaker
AH12 HEAT PUMP
Heat Pump Watts| 485/465
Heat Pump BTU| 6200/6000
COP| 3.6
DIMENSIONS
WALL CASE DIMENSIONS
RAB80 WALL SLEEVE
Heavy-gauge galvanized steel, with insulation, for quick self-assembly. A – 42”, B – 13-3/4”, C – 16”
MAXIMUM CORD EXTENSION
WALL OPENING DIMENSIONS Add 1/4” to A and C dimensions for all cut-outs. RAB80 16-1/4” Min. H x 42-1/4” Min. W
FEATURE AND BENEFITS
- 7,300 / 7,200 cooling BTU
- 12.9 / 13.0 EER
- 6,200 / 6,000 heating BTU
- 3.6 COP
- R32 Refrigerant – Environmental friendly, low GWP (Global Warming Potential)
- 3-Speed Fan – Give guests control over their comfort with three fan speeds to choose from
- 4-Temperature Limiting Options – Easily select one of four temperature ranges for peak efficiency and total customer comfort
- Intuitive Display – Allow guests to easily customize their preferred settings and reduce maintenance calls with an easy-to-use control panel
- Power Cord (LCDI) Included – Hotpoint PTACs come with everything needed for a quick and easy installation
- Automatic Emergency Heat – Keep guests comfortable with a heating option that uses electric resistance heat in heat pump mode
- Freeze and Frost Protection – Automatic freeze and indoor frost control keep units operating in peak condition
- Auto Power Recovery – In case of power failures, units automatically resume their operation when power is restored, reducing maintenance calls
- Self Diagnostics – Quickly and easily identify service needs with a nine-point diagnostic code system
- Backed by an Industry Leader – With a long history of creating durable products at an affordable price, Hotpoint is your trusted PTAC brand
PRELIMINARY SPECIFICATIONS – SUBJECT TO CHANGE
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>