Hotpoint AH12H07D2B Electric Heater Heat Pump User Guide

May 15, 2024
Hotpoint

Hotpoint AH12H07D2B Electric Heater Heat Pump

Hotpoint-AH12H07D2B-Electric-Heater-Heat-Pump-product

Product Information

Specifications

  • Model: AH12H07D2B
  • Heater Watts: 2580/2150
  • Heater BTU: 7800/6300
  • Heater Amps: 11.3/10.3
  • Heat Pump Watts: 485/465
  • Heat Pump BTU: 6200/6000
  • COP: 3.6
  • Voltage: 230/208 V

 roduct Usage Instructions

Dimensions and Installation Information

Wall Case Dimensions:

A: 30 inches

C: 70 inches

Maximum Cord Extension: 30 inches

Wall Opening Dimensions: Add 1/4 to A and C dimensions for all cut-outs.

RAB80 16-1/4 Min. H x 42-1/4 Min. W

AH12 Electric Heater

  • Line Cord Connected Units
  • Min Circuit: 15
  • Recommended Protective Device: 15 amp time-delay fuse or breaker

AH12 Heat Pump

  • Heat Pump Specifications:
  • COP: 3.6

FAQ

Q: What is the recommended circuit for the AH12 Electric Heater?

A: The recommended circuit for the AH12 Electric Heater is a minimum of 15 amps with a time-delay fuse or breaker.

Q: What are the dimensions of the wall case for installation?

A: The wall case dimensions are A: 30 inches and C: 70 inches. Additionally, add 1/4 inch to A and C dimensions for all cut-outs.

Hotpoint® PTAC Heat Pump Unit with Electric Heat Backup 15 amps, 230/208 Volt

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

ELECTRICAL WIRING

  • All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.
    NOTE: Aluminum wiring may pose special problems – consult a qualified electrician.

GRILLE OPTIONS

  • Stamped Aluminum Grille – RAG70

ELECTRICAL CONNECTION

  • 230/208 volt units must be plugged into a receptacle. Installation must comply with local electrical codes and regulations.
  • Power cord is permanently attached on all Hotpoint chassis

Specifications

AH12 ELECTRIC HEATER

230/208 VOLT| LINE CORD CONNECTED UNITS
Heater Watts| 2580/2150
Heater BTU| 7800/6300
Heater Amps| 11.3/10.3
Min Circuit| 15
Recommended protective Device| 15 amp time-delay fuse or breaker
AH12 HEAT PUMP
Heat Pump Watts| 485/465
Heat Pump BTU| 6200/6000
COP| 3.6

DIMENSIONS

WALL CASE DIMENSIONS

RAB80 WALL SLEEVE

Heavy-gauge galvanized steel, with insulation, for quick self-assembly. A – 42”, B – 13-3/4”, C – 16”

MAXIMUM CORD EXTENSION

WALL OPENING DIMENSIONS Add 1/4” to A and C dimensions for all cut-outs. RAB80 16-1/4” Min. H x 42-1/4” Min. W

FEATURE AND BENEFITS

  • 7,300 / 7,200 cooling BTU
  • 12.9 / 13.0 EER
  • 6,200 / 6,000 heating BTU
  • 3.6 COP
  • R32 Refrigerant – Environmental friendly, low GWP (Global Warming Potential)
  • 3-Speed Fan – Give guests control over their comfort with three fan speeds to choose from
  • 4-Temperature Limiting Options – Easily select one of four temperature ranges for peak efficiency and total customer comfort
  • Intuitive Display – Allow guests to easily customize their preferred settings and reduce maintenance calls with an easy-to-use control panel
  • Power Cord (LCDI) Included – Hotpoint PTACs come with everything needed for a quick and easy installation
  • Automatic Emergency Heat – Keep guests comfortable with a heating option that uses electric resistance heat in heat pump mode
  • Freeze and Frost Protection – Automatic freeze and indoor frost control keep units operating in peak condition
  • Auto Power Recovery – In case of power failures, units automatically resume their operation when power is restored, reducing maintenance calls
  • Self Diagnostics – Quickly and easily identify service needs with a nine-point diagnostic code system