AUO P1000-R ADP Panel PC Instruction Manual

June 17, 2024
AUO

ADP Panel PC
USER MANUAL
Hardware installation manual

P1000-R ADP Panel PC

Disclaimers
This manual and other documents, including printed and electronic versions, are for reference only. ADP has done its best to ensure the accuracy and completeness of the information in this manual. This manual and other documents are provided on an “as-is” basis. However, ADP does not provide any express or implied warranties or guarantees for any of the content in the manual or documents, including guarantees for the commerciality or merchantability for any particular purpose, nor does ADP guarantee results obtained from the use of this manual or the accuracy or reliability of information obtained from this manual.
ADP will not be liable for any damages, including but not limited to indirect, direct, consequential, or incidental damages, arising out of or in connection with the use of this manual and other documents. Some countries or regions may not allow the complete exclusion or limitation of liability of the abovementioned damages and thus those limitations or exclusions may not apply to you.
The purpose of the manual is to provide customers with the most up-to-date and accurate information. ADP reserves the right to modify or change the manual at any time. Any of the contents may be modified at any time without prior notice. Visit ADP’s official website, details on updates to the manual or product changes.
The ownership and intellectual property rights of third-party products or content mentioned in this user manual belong to the respective product or content owners, and are protected by current laws and international treaties related to intellectual property rights.

In either of the following two situations, this product will no longer be covered by ADP’s warranty and services:

  1. The product has been subjected to such actions as repair, changes to specifications, or replacement of components, without being authorized by ADP.
  2. The serial number of the product has been lost or is not clearly readable.

Welcome to this user manual ADP Panel PC

Comprehensive space management and information

AUO P1000-R ADP Panel PC

service provider
ADP Panel PC is committed to integrating the best technology and services with the service mechanisms required by space and developing smart space service terminals, all to provide users with all-round superior space management solutions. You can easily complete operations on the Panel PC, whether you want to book a conference, reserve a space on site, call for services, or inquire about conferences, courses, or personal information using your RFID identification card.

Introduction to the ADP Panel PC

External composition

AUO P1000-R ADP Panel PC - External composition

AUO P1000-R ADP Panel PC - External composition 1

AUO P1000-R ADP Panel PC - External composition 2

Hardware component specifications

LCD panel specifications

Dimensions| 10-inch LED backlit panel
Contrast| 800:1
Brightness| 350 nits
Viewing angle| -85° – 85° (horizontal); -85° – 85° (vertical)
Touchscreen| Capacitive touch monitor; supports multi-touch
System specifications
Processor| Quad-Core ARM Cortex-A55 CPU 1.8 Hz
Memory| 16 GB LPDDR3
Storage device| Onboard 32 GB eMMC
Operating system| Android 11
System input/output
Digital input/output| 2 x DI, 2 x DO, where one of the DO supplies 12V 1A to drive the lock
LED indicator lamp strip| RGB color (front indicator light strip x 1, side indicator light strip x 2
IBeacon| Built-in iBeacon Transmitter
Reset button| 1 x Reset button
USB port| USB 2.0 port x 1 / USB 3.0 port x 1 / USB OTG x 1
Ethernet / LAN| 1 x RJ45 10/100/1000; supports PoE, IEEE 802.3AT
Built-in equipment
Frontend NFC & HID| Compliance: 13.56MH zand 125KHz
Supports MIFARE standard, 14443A S50 and S70 14443A protocol cards Sensing distance of 3 cm
Audio in| Front directional microphone
Audio out| 1 watt speaker x 2
Camera module| 2 million pixels, wide dynamic range, FF (fixed focus); aperture F = 2.0, night fill light
Watchdog| Hardware watchdog
Power specifications
Power over Ethernet| 802.3 AT
DC power supply| 12V
Power consumption| 25 watts (on full load)
Structural specifications
Cooling system| Fanless aluminum heat sink
Wall mounting| VESA Mount (7 5x 75mm)
Exterior dimensions| Width 260 x Height 190 x Thickness 28mm
Environmental specifications
Operating temperature| 0°C ~ 50°C
Operating humidity| 10% ~ 90%
Water protection rating| Front-end IP54 protection from water spray

Hardware connections and settings

Wall mount bracket

Panel PC back bracket

AUO P1000-R ADP Panel PC - Panel

Accessory bag and installation manual

Hexalobular socket anti-theft screw

Hardware installation manual

Panel PC installation and cabling specifications
2.1 Recommend installation locations for Panel PC
Suitable height for installation based on average height: when installing the Panel PC, the lower edge of the device body should be 136cm above ground level; height can also be adjusted according to the customer’s actual usage.
As in the figure below:

2.2 Panel PC cabling system structure

AUO P1000-R ADP Panel PC - Panel 2

❶ Door lock electric lock DO directly drives the electric lock, no additional power supply needed.
❷ Open door button DI connection to door lock button
❸Server
Ethernet supplies PoE power to the device, and no additional power supply is required

2.3 Reference for matching electric lock forms

AUO P1000-R ADP Panel PC - lock forms

Electric lock must be selected in accordance with the onsite door material and specifications. When choosing an electric lock, pay attention to the following:

  • Door type: Opens in, opens out, opens both in and out, side-pull or sliding door, etc.
  • Door frame material: Metal [aluminum alloy, stainless steel], wooden, glass doors [with/without door frame].
  • Door margins: Pay attention to the margins between the door and the door jamb to avoid the door becoming stuck during opening or closing.
  • Height and size: Door height, size, and weight.
  • Door number: Single, double, other.
  • Purpose of passage: Fire escape, warehouse, normal passage, other.
  • Other: Special requirements, signal output, or time delays.

2.4 Precautions when installing

  • The power over Ethernet switch [PoE switch] must be grounded to avoid equipment failure caused by static electricity.
  • A 4-core cable is used between the door lock electric lock and the Panel PC terminal. Cable diameter must be greater than 0.5 mm2. Model: RVV4 × 0.5mm2.
  • A 2-core wire is used to connect the door opening button and the controller. Wire diameter must be greater than 0.5 mm2. Model: RVV2 × 0.5mm2.
  • Data transmission between server and Panel PC is over a CAT 6 network cable. When the DC power cable and signal cable pass through the same conduit, try to use shielded cables.
  • AC power cables and signal cables must be passed through conduits, and the two conduits should have space between them when they are arranged parallel over a long distance.
  • Over 50cm.
  • It is required to mark the cables when arranging them; wire connectors must be placed in the junction box.
  • Pay attention to the cabling specifications of the terminals. Avoid having excessively long or exposed metal parts to prevent short circuits and communication failures.

2.5 Detailed cabling diagram of electric lock/output button and Panel PC

AUO P1000-R ADP Panel PC - cabling

  1. Electric lock DC 12V
  2. Electric lock ground cable
  3. Door status detection NO
  4. Door status detection COM
  5. Open door button detection NO
  6. Open door button detection COM

2.6 Panel PC back bracket and device body installation diagram

Step ① First decide whether the back bracket is to be placed in the middle, close to the left wall, or close to the right wall. You can determine the position of the back bracket based on the cabling direction.

Back bracket cutting method:
After confirming the position of the back bracket,
Cut the front section with diagonal cutting pliers
Twist open with crimping pliers
Smooth sharp edged with sandpaper

AUO P1000-R ADP Panel PC - Panel PC back

Middle
Cut both sides of the back frame, and then continue with the installation steps from Step ②.

Close to left wall
Cut the right side of the back frame and continue with the installation steps from Step 5.

Close to right wall
Cut the left side of the back frame and continue with the installation steps from Step 5.

Step ②
Pull the rubber off of the bracket and cut the adhesive back.

AUO P1000-R ADP Panel PC - adhesive back

Step ③
After arranging cabling through the back panel, confirm the horizontal position, then peel off the back adhesive and stick it to the wall.
Get suitable self-tapping screws or screws that fit with the material of the wall (stud) and fasten to the wall.

Step ④ Connect the Ethernet cable and control cable, insert the tenon from top to bottom, and screw in the anti-theft screw at the bottom. Middle installation is complete

AUO P1000-R ADP Panel PC - Connect the Ethernet

Step ⑤ Drill a hole, and use a hammer to pry it open. Then use pliers to twist it open, and sand the sharp edges to avoid damaging the wire.

Close to left wall

AUO P1000-R ADP Panel PC - Close to left wall 2

Close to right wall

AUO P1000-R ADP Panel PC - Close to right wall 2

Step ⑥ After arranging cabling through the back panel, confirm the horizontal position, then peel off the back adhesive and stick it to the wall.
Get suitable self-tapping screws or screws that fit with the material of the wall (stud) and fasten to the wall.

Close to left wall

Close to right wall

Step ⑦ Take the rubber off of the back of the device. Connect the Ethernet cable and control cable, insert the tenon from top to bottom, and screw in the anti-theft screw at the bottom. Close to left/right wall installation complete.

Close to left wall

AUO P1000-R ADP Panel PC - Close to left wall 4

Close to right wall

AUO P1000-R ADP Panel PC - Close to right wall 4

DIO activity meter

| Mode| Figure| Explanation
---|---|---|---
1| Keep DO at Hi| |
2| Keep DO at Lo| |
3| DI ↓,DO=H| | 1. This mode is applicable when the door opening button connected to DI is Normal Close and the electric lock connected to DO is powered to unlock.
2. When DI↓, start counting X(s).
4| DI ↓, DO=L| | 1. This mode is applicable when the door opening button connected to DI is Normal Close and the electric lock connected to DO is unpowered to unlock.
2. When DI↓, start counting X(s).
5| DI ↑, DO=H| | 1. This mode is applicable when the door opening button connected to DI is Normal Open and the electric lock connected to DO is powered to unlock.
2. When DI↑, start counting X(s).
6| DI ↑, DO=L| | 1. This mode is applicable when the door opening button connected to DI is Normal Open and the electric lock connected to DO is unpowered to unlock.
2. When DI↑, start counting X(s)

[Note] X(S) is the number of seconds of delay

Thanks for using the Panel PC system
For more information, service, and support
See the following resources or use the following channels to obtain more information on Panel PC security, software, services, and support.
AUO Display Plus website https://www.auodplus.com/en-global

About FCC compliance
FCC ID:2A639-P1000-R
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, ifnot installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with minimum distance 20cm between the radiator and your body:
Use only the supplied antenna.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>