VORTAX VXC4-200-80 Submersible Pumps Owner’s Manual
- July 25, 2024
- VORTAX
Table of Contents
VXC4
Submersible pumps – 4 POLES
※ Submersible pumps 4 poles (1450 min-¹)
Sewage
Civil use
Industrial use
PERFORMANCE RANGE
- Flow rate up to 5000 l/min (300 m³/h)
- Head up to 22.5 m
INSTALLATION AND USE
The VXC4 series is constructed from thick stainless steel and cast iron,
offering exceptional robustness, abrasion resistance, and durability.
Equipped with a VORTEX-type impeller, the pumps are designed to drain sewage,
sludgemixed water, and activated and putrid sludge. They are suitable for a
wide range of applications, including sewers, tunnels, excavations, canals,
and underground parking facilities.
ELECTRIC MOTOR
※ Electric motor with built-in three-phase thermal protection in the winding
must be connected to the electrical panel.
N.B. The warranty is valid if the thermal protection is connected to the
electrical panel.
INCLUDES
※ Power cable length 10 m
APPLICATION LIMITS
- Depth below water level up to 10 m (with an appropriately sized power cable)
- Liquid temperature up to +40 °C
- Capable of processing suspended solids up to Ø 80 mm
- For continuous service, the pump must not rise more than 290 mm
AVAILABLE UPON REQUEST
※ Pumps equipped with internal probes that detect the presence of water in the
oil chamber
※ Pumps with double cable for star/delta starting
※ Different voltage requirements 60 Hz frequency
Q = Flow rate H = Total manometric head
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
ABSORPTION
TYPE
Three-phase| TENSIONE
---|---
230 V –| 400 V –| 400 V –| 690 V –
VXC4-100/80| 32.9 A| 19.0 A| 19.0 A| 11.0 A
VXC4-125/80| 36.3 A| 21.0 A| 21.0 A| 12.1 A
VXC4-150/80| 40.7 A| 23.5 A| 23.5 A| 13.6 A
VXC4-200/80| 49.3 A| 28.5 A| 28.5 A| 16.5 A
DIMENSIONS AND WEIGHT
TYPE
Three-phase| Passage of solid bodies| DIMENSIONS mm| kg
---|---|---|---
a| b| c| h| h1| 3~
VXC4-100/80| Ø 80 mm| 285| 228| 395| 858| 130| 215
VXC4-125/80| 217
VXC4-150/80| 227
VXC4-200/80| 237
PORT FLANGE
TYPE
Three-phase| FLANGE
DN| K
mm| D
mm| HOLES
---|---|---|---|---
N°| Ø (mm)
VXC4-100/80
VXC4-125/80
VXC4-150/80
VXC4-200/80| 100
(PN10)| 180| 220| 8| 18
COUNTERFLANGE
(CAN BE ORDERED SEPARATELY)
TYPE
Three-phase| FLANGE
DN| F| K
mm| D
mm| HOLES
---|---|---|---|---|---
N°| Ø (mm)
VXC4-100/80
VXC4-125/80
VXC4-150/80
VXC4-200/80| 100| 4″| 180| 220| 8| 18
BASE
(CAN BE ORDERED SEPARATELY)
50 Hz | VXC4
MATERIALS AND COMPONENTS
1 | Pump body | Cast iron with cataphoresis treatment |
---|---|---|
2 | Impeller | Cast iron VORTEX type with cataphoresis treatment |
3 | Motor holder | Cast iron |
4 | Motor cover | Cast iron |
5 | Motor shaft | Stainless steel AISI 431 |
6 Double mechanical seal with interposed oil chamber
Seal | Shaft | Location | Materials |
---|---|---|---|
MG1-43 | Ø 43 mm | Motor side | Ceramic / Graphite / NBR |
ARP-40 | Ø 40 mm | Pump side | Silicon carbide/Silicon carbide/NBR |
7 Electric Motor
Three-phase 230/400 V – 50 Hz or 400/690 V – 50 Hz with winding integrated
thermal three-phase motor protection to be connected to the switchboard
– Insulation: class F
– Protection rating: IP X8
8 ※ Probe for detecting water in the oil chamber
9 Power cord
※ 10 metres ‘EM2 quality’ type
SEWAGE LIFTING SYSTEM VXC4 – MC4
VERSION WITH VERTICAL DELIVERY AND 2″ GUIDE TUBES
For VXC4, MC4 | Code ASSPVXC4V | DN 4″ |
---|
※ Kit consisting of:
| |
---|---|---
Coupling foot complete with counterflange| Slide rail with screws and gasket|
Support for guide tubes
ACCESSORIES AVAILABLE FOR ORDER
RUNNING GUIDE
※ For VXC4, MC4 | Code ASSFL100 |
---|
Complete with screws and seals
INTERMEDIATE GUIDE TUBE SUPPORT
※ For guide tubes Ø 2″ | Code 859SV349INTFA |
---|
For reasons of stability interpose a support every 3 metres
GUIDE TUBE ( AISI 304 stainless steel)
※ 3 metres Ø 2″ guide tube | Code 54SARTG0063F |
---|---|
※ 6 metres guide tube Ø 2″ | Code 54SARTG0066F |
Typical installation
1. Water pump
2. Pump Base
3. Guide Rails
4. Upper Guide Rail Support
5. Intermediate Guide Rail Support
6. Lifting chain
7. Control Panel| 8. Stop Float Switch
9. Start Float Switch
10. Supplementary pump start float switch
11. Alarm float
12. Check valve
13. Pump Pedestal
---|---
DIMENSIONS
SEWAGE LIFTING SYSTEM VXC4 – MC4 | 50 Hz
Read User Manual Online (PDF format)