ThermoLife ET-62W Easy Touch Easy Warm User Manual

June 17, 2024
Thermolife

Thermostat Instruction
Easy touch Easy warm
APP for ET-62W

ET-62W Easy Touch Easy Warm

ThermoLife ET-62W Easy Touch Easy Warm -

INTRODUCTION

The 62 series is an intuitive programmable thermostat used to control electrical floor heating system or water heating system. It will keep home at comfortable temp whilst minimizing energy use. Install the app on your smart phone to control heating system remotely with the WiFi thermostat.

TECHNICAL SPECIFICATIONS

Supply voltage: 85-265Vac 50/60Hz
Standby power: <1W
Max load: 16A(electric heating)/3A(water heating)
IP class: IP21
Cable specification: ≤2.5mm²

INSTALLATION

|
---|---
Step 1: Loosen fixing screw located in the bottom of the thermostat to get the front panel.| Step 2: Connect the thermostat according to the Wiring Instruction.
|
Step 4: Align top part of front panel and back panel to fit these two parts. Then fix them with screw.| Step 3: Insert the back panel into wall box with provided screws.

WIRING INSTRUCTION

Suggestion: Please keep the max load around 90% of 16A to prolong the lifetime.

THERMOSTAT SYMBOLS

ThermoLife ET-62W Easy Touch Easy Warm - HERMOSTAT
SYMBOLS

WIFI CONNECTIONION

Step 1: Scan the QR code or download the Warmme from APP store/ Google browser. Step 2:
Register and log in with mobile number/email address in the APP.
Attention : Please read and agree ‘Privacy Policy and Service agreement’ before registration. Step 3: Click ‘Add Device’ or ‘+’ on the top-right to add device. Step 4: Click ‘WiFi thermostat’. Step 5:
Operate thermostat. If the WIFI icon flash quickly, Click ‘Press to connect.

Step 6: Enter Wifi password, and click ‘Confirm’ Step 7:
If device added successfully, you can change the device name and set region. Then, click ‘Done’.
Attention: If failed, confirm the Wifi is 2.4G version and check the Wifi signals, then, use the ‘AP mode’ in the top right to connect again.

Step 8:
You can check the actual temperature and set temperature etc. at the control interface.

FUNCTION AND OPERATION

7.1 On/Off
Press to turn On/Off.
Note : When frost protection is active, the thermostat will maintain the frost protection temp when it is Off.
7.2 Temporary Override Temperature
The temporary override temp is only valid at the current event and it will not be saved.
On the actual temp interface, press to set temporary override temp.
Press to confirm and back to the actual temp interface.
7.3 Key-Lock
Lock all keys to prevent the settings from being changed. On the actual temp interface, press and hold for 3 seconds to lock or unlock all the keys.

7.4 Set the Time

On the actual temp interface, press then the will flash.

Press to enter day setting.
Press to set day.
Press to enter hour setting.
Press to set hour.
Press to enter minute setting.
Press to set minute.
Press to confirm and back to the day setting interface.
Press twice to back to the actual temp interface.

  • If the thermostat is WiFi version, it will update time automatically after connecting to WiFi.

7.5 Holiday Mode

In Holiday Mode, the thermostat will maintain the set temp until the holiday time ends.
On the actual temp interface, press then the will flash.
Press to select .
Press to enter holiday days setting.
Press to set holiday days.
Press to enter temp setting.
Press to set temp.
Press to confirm and back to the actual temp interface.

  • Set the holiday days to zero or double press to cancel Holiday Mode.

7.6 Hold Mode
In Hold Mode, The thermostat will hold the set temp until you cancel this mode.
On the actual temp interface, press then the will flash.
Press to select .
Press to enter Hold ON/OFF setting.
Press to set Hold ON.
Press to enter temp setting.
Press to set temp.
Press to confirm and back to the actual temp interface.

  • Set hold OFF or double press to cancel Hold Mode.
    7.7 Edit Setting

Edit Setting can set and change the parameters. If you don’t choose Holiday Mode or Hold Mode.The thermostat runs according to the parameters of Edit.
On the actual temp interface, press then the will flash.
Press to select .
Press to enter day selection of Edit Setting.
Press to select a day.
Press to enter the event selection of the day.
Press to select a event.
Press to select event’s starting time.
Press to set the hour of starting time.
Press to enter the minute setting.
Press to set the minute of starting time.
Press to enter the temp setting.
Press to set the temp.
Press to confirm and back to the event selection of the day.

  • Press some times or double press to back to the actual temp interface.

Default Parameters

Day Wake Leave Back Sleep
Mon-Fri 07:00  22.0°C 08:30  19.0°C 17:00  22.0°C 22:00  19.0°C
Sat/Sun 08:00  22.0°C 08:30  22.0°C 17:00  22.0°C 22:00  19.0°C

7.8 Advanced Setting

The thermostat provides advanced settings to suit various special situation. These are normally set by technicians during initial installation.
On the actual temp interface, press then the will flash.
Press to select .
Press to enter advanced setting.
Each setting can be accessed by pressing and parameters adjusted by pressing .

No. Name Default Ranges
1 Room temp calibrate 0.0°C -5.0°C — 5.0°C
2 Floor temp calibrator 0.0°C -5.0°C — 5.0°C
3 Anti-frozen function ON OF(OFF) ON
4 Anti-frozen temp 5.0°C 5.0°C — 15.0°C
5 Sensor selection 01: Floor sensor 00: Room sensor

1:Floor sensor
2:Both sensors
6| Floor temp limit| 30.0°C| 20.0°C — 50.0°C
7| Temp unit| 00: °C| 00: °C
01: °F
8| Output delay| 00: OOs| 00: OOs
1:30s
2:60s
3:90s
9| ..ition| 01: 1.0°C| 00: 0.5°C
1:1.0°C
2:2.0°C
3:3.0°C
10| Reverse output| 00: OFF| 00: OFF 01: ON
11| Schedule| 01: 5+1+1| 00: 7
01: 5+1+1
12| Adaptive function| 00: OFF| 00: OFF 01: ON
13| Reset| 00: No| 00: No 01: YES

  1. Room temp calibration: Calibrate the temp detected by room sensor.

  2. Floor temp calibration: Calibrate the temp detected by floor sensor.

  3. &4. Anti-frozen function: This option allow you to bring warmth to your plant and pet with a lower temp.
    displays when you turn off the thermostat.
    In hydronic heating system, it will keep away from freezing.

  4.  Sensor selection:
    00 Room sensor: Run by room sensor.
    01 Floor sensor: Run by floor sensor.
    02 Both sensors: Run by room sensor with floor temp limit.

  5. Floor temp limit: If you choose both sensors, floor temp limit must be set to protect floor.

  6. Temp unit: °C and °F can be selected.

  7. Output delay: This option help you avoid inadvertent operation on heating.

  8. Temp deviation: The deviation is 1°C. The thermostat start to work when the actual temp is 1°C lower than set temp and stop to work when the actual temp is 1°C higher than set temp.

  9. Reverse output: This function works for the cooling system. When the temp is 1°C higher than set temp, the thermostat will disconnect the cooling system. otherwise, it will connect the cooling system.

  10. Schedule: Select a weekly schedule for the Edit. There are 2 options:
    7: each day from Mon to Sun can be set individually.
    5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually.

  11. Adaptive function: After several days of installation and use, Adaptive function ensures that the required temp has already been reached when the next event begins.

  12. Reset: All parameters are restored to default values.

7.9 Open window detection
This function only works when room sensor or both sensors is selected. The thermostat with this function will shut off automatically for 15 min when the window opens, as it can detect that the room temp plummets.

TROUBLESHOOTING

E1: Room sensor error.
E2: Floor sensor error.

DIMENSION(MM)

ThermoLife ET-62W Easy Touch Easy Warm - DIMENSION

http://e.tuya.com/warmme

Documents / Resources

| ThermoLife ET-62W Easy Touch Easy Warm [pdf] User Manual
ET-62W Easy Touch Easy Warm, ET-62W, Easy Touch Easy Warm, Touch Easy Warm, Easy Warm
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals