Control4 Z-Wave S2
Setup Guide
Control4 Disclaimer
Control4 makes no representations or warranties with respect to this publication, and specifically disclaims any express or implied warranties of merchantability or fitness for any particular purpose. Control4 reserves the right to make changes to any and all parts of this publication at any time, without any obligation to notify any person or entity of such changes.
Legal Notices
GNU
GNU GENERAL PUBLIC LICENSE TERMS AND CONDITIONS FOR COPYING, DISTRIBUTION AND
MODIFICATION (Section 3.b.)
You may copy and distribute the Program (or a work based on it, under Section
2) in object code or executable form under the terms of Sections 1 and 2 above
provided that you also do one of the following:
Accompany it with a written offer, valid for at least three years, to give any
third party, for a charge no more than your cost of physically performing
source distribution, a complete machine-readable copy of the corresponding
source code, to be distributed under the terms of Sections 1 and 2 on a medium
customarily used for software interchange.
The complete text for this license is available on the Control4 website at:
http://www.control4.com.
Gracenote
Gracenote®, Gracenote logo and logotype, and the “Powered by Gracenote” logo
are either a registered trademark or a trademark of Gracenote, Inc. in the
United States and/or other countries. Music and DVD recognition technology and
related data are provided by Gracenote®. Gracenote is the industry standard in
Music and DVD recognition technology and related content delivery. For more
information visit www.gracenote.com.
MPEG
Fraunhofer IIS and Thomson. MPEG Layer-3 audio coding technology licensed from
Fraunhofer IIS and Thomson. Supply of this product does not convey a license
nor imply any right to distribute content created with this product in
revenue-generating broadcast systems (terrestrial, satellite, cable, and /or
other distribution channels), streaming applications (via Internet, intranets,
and/or other networks), other content distribution systems (pay-audio or
audio-on-demand applications, and the like) or on physical media (compact
discs, digital versatile discs, semiconductor chips, hard drives, memory
cards, and the like). An independent license for such use is required. For
details, visit http://mp3licensing.com. Radio Locator is the service
provider of AM/FM channel list.
Spread
This product uses software developed by Spread Concepts LLC for use in the
Spread toolkit. For more information about Spread see http://www.spread.org.
Z-Wave
Z-Wave™ and Z-Wave Plus™ are the registered trademarks of the Z-Wave Alliance.
Copyright and Trademarks
© 2023, Snap One, LLC. All rights reserved. Snap One and its respective logos
are registered trademarks or trademarks of Snap One, LLC (formerly known as
Wirepath Home Systems, LLC), in the United States and/or other countries.
4Store, 4Sight, Control4, Control4 My Home, SnapAV, Araknis Networks, BakPak,
Binary, Dragonfly, Episode, Luma, Mockupancy, Nearus, NEEO, Optiview, OvrC,
Pakedge, Sense, Strong, Strong Evolve, Strong VersaBox, SunBriteDS,
SunBriteTV, Triad, Truvision, Visualint, WattBox, Wirepath, and Wirepath ONE
are also registered trademarks or trademarks of Snap One, LLC. Other names and
brands may be claimed as the property of their respective owners. Snap One
makes no claim that the information contained herein covers all installation
scenarios and contingencies, or product use risks. Information within this
specification subject to change without notice.
Pricing and specifications subject to change without notice.
No part of this publication may be reproduced, photocopied, stored on a
retrieval system, or transmitted without the express written consent of the
publisher.
Contact Information
Control4 Corporation
11734 S. Election Road
Salt Lake City, UT 84020 USA
http://www.control4.com
DOC-00228-C 5/2/2023 DH
Z-Wave S2 Setup Guide
With a Control4© CORE 3 or CORE 5 controller you can add and control
supported ZWave™ devices to your Control4 system. The Z-Wave radios in the
CORE controllers are Z-Wave S2 compliant and support Z-Wave Long-Range
devices. Z-Wave S2 requires a CORE 3 or CORE 5 controller running OS 3.3.1 or
newer.
Note! This guide covers Z-Wave S2 on a CORE controller. For the Z-Wave
module on an EA or CA-1 controller, see
ctrl4.co/z-wave.
Important! For best results, do not install the controller running Z-Wave
in a metal enclosure or near materials that interfere with wireless signals.
Configuring a Z-Wave S2 controller
You can use System Design to check the project properties, enable a Z-Wave controller, and view the status of the Z-Wave controller running in a Control4 project.
To configure a Z-Wave S2 controller:
- In the Project Tree, select the Project Name (top line of the Project Tree) object for the project properties to appear.
- Click on the Z-Wave Configuration tab.
- Check the box under Z-Wave Enabled for the controller you want to be your Z-Wave controller.
Note: Only one Z-Wave controller can be configured in a Control4 project.
The configuration should show a status of SecureS2 for Z-Wave S2 on a CORE controller when it is configured properly. If the Status field is empty, make sure the ZWave module is connected and installed properly, and that the CORE controller is online and identified in the project.
Note: The Status field for a Z-Wave module on an EA or CA-1 controller will show SecureS0 to indicate a legacy Z-Wave network when it is configured properly.
Advanced configuration
Several options are available for advanced Z-Wave configurations in the Z-Wave Configuration tab in the project properties window. These are not required in most cases when operating Z-Wave devices with a Z-Wave module in a Control4 system. They can be used for extending operation with external devices and thirdparty Z-Wave controllers.
● Reset Defaults —Reset Defaults clears the Home ID on the Z-Wave controller and abandons any nodes on the existing network. Any Z-Wave devices previously joined to the network must be removed before they can join the new network. See “Removing Z-Wave devices.” Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
Note: If this controller is the primary controller for your network, resetting it will result in the nodes in your network being orphaned and it will be necessary, after the reset to defaults, to reset and re-add all of the nodes in the network. If this controller is being used as a secondary controller in the network, use this procedure to reset this controller only if the network primary controller is missing or otherwise inoperable.
● Send Node Info —When connected to another mesh, Send Node Info sends information about the controller to all other devices on the mesh.
Adding Z-Wave devices
After configuring your Z-Wave controller, add drivers corresponding to the Z-Wave devices to your project. Many legacy Z-Wave device drivers will also need a motorization, sensor, or light driver, like a door or window driver, added into your Control4 project to represent the Z-Wave device in a Control4 Navigator.
Z-Wave Common drivers
Z-Wave Common drivers can be used for Z-Wave S2 devices if there is not a manufacturer-specific Z-Wave driver. Z-Wave Common drivers include:
- Z-Wave Common Light—You can use this common light driver for many Z-Wave S2 lights and dimmers.
- Z-Wave Common Sensor—You can use this common sensor driver for many Z-Wave S2 sensors, like a window sensor or a motion sensor.
- Z-Wave Common Relay—You can use this common sensor for many Zwave S2 relays, like a door lock or outlet switch.
To add a Z-Wave Common driver into your project:
- In System Design, enter Z-Wave Common in the Search tab.
- Double-click on the driver to add it into the project. You can also rightclick on the driver and select Add to Project to add the driver.
- If you have more than a couple Z-Wave devices, it is recommended that you rename this driver to help with troubleshooting multiple devices. Right-click on the driver and select Rename. Enter a descriptive name and press Enter.
Z-Wave legacy device drivers
To add a Z-Wave legacy device driver into your project:
- In System Design, enter the name of driver in the Search tab.
- Double-click on the driver to add it into the project. You can also rightclick on the driver and select Add to Project to add the driver.
- If you have more than a couple Z-Wave devices, it is recommended that you rename this driver to help with troubleshooting multiple devices. Right-click on the driver and select Rename. Enter a descriptive name and press Enter.
Most Z-Wave device drivers will also need a motorization, sensor, or light driver. For example, a window contact sensor device driver also needs the Window Contact Sensor driver and an outlet module device driver needs the Z-Wave Dimmable Light (Outlet) driver.
Motorization, sensor, and light drivers
To add a motorization, sensor or light driver into your project:
- In System Design, enter the name of the driver in the search field in the Search tab.
- Double-click on the driver to add it into the project. You can also rightclick on the driver and select Add to Project to add the driver.
- This is the driver that will show up in the UI, rename the driver to represent the device it is controlling. Right-click on the driver and select Rename. Enter the name to be shown in the UI and press Enter.
Connecting Z-Wave devices
After you have added all the necessary device drivers and motorization, sensor or light drivers into your project, you are ready to make the necessary connections for these drivers.
There are two types of connections that need to be made:
- Connect Z-Wave device drivers to the Z-Wave controller and identify them into the project
- Connect Z-Wave device drivers virtually in the Control4 project to motorization, sensor, or light drivers
Connecting Z-Wave S2 device drivers to the ZWave network
To connect a Z-Wave device driver to the Z-Wave controller:
- In Connections in the Network tab, select Z-Wave Network.
- In Available Devices on the right, click Add.
- Identify (add) the Z-Wave device according to the manufacturer’s instructions, usually by pressing a Z-Wave button on the device. See the documentation for the Z-Wave device for more information.
- For Z-Wave S2 devices, If prompted, enter the pin. The pin is usually found on the device itself and is required to enable secure Z-Wave S2 functionality. If the pin is entered incorrectly, the device functionality will be limited.
- Click and drag the device from Available Devices to the driver for the ZWave device in the middle pane and release the mouse.
Connecting legacy Z-Wave device drivers to the ZWave network
To connect a Z-Wave device driver to the Z-Wave controller:
-
In Connections in the Network tab, select Z-Wave Network.A list of Z-Wave device drivers will show in the Z-Wave Network Connections window.
-
Double-click on the Z-Wave device driver to open the identify window or highlight the device and click on the Identify button.
-
Identify (add) the Z-Wave device according to the manufacturer’s instructions, usually by pressing a Z-Wave button on the device. See the documentation for the Z-Wave device for more information.
Note: You have 60 seconds to identify (add) the Z-Wave device to the network and a timer will show the time remaining. If you run out of time, close the window and try to identify the Z-Wave device again. -
After adding the Z-Wave device to the Z-Wave network, the driver will do some additional configuration.
Important: Do not skip this step by closing the window or clicking next! -
If the device is added, configured, and identified successfully, the address will show in the address field and the timer instructions will change to say “Identification Successful”. Note: If the Z-Wave device will not identify (add), you should try to remove the device and then try to identify the device again. See “Removing Z-Wave devices”.
Using the Z-Wave SmartStart agent to add devices
You can add SmartStart-enabled devices into a network by entering the DSK into
a Node Provisioning List of a controller providing SmartStart inclusion. No
further action is required and the SmartStart device is added automatically
when switched on in the network vicinity.
The Control4 CORE controllers can perform SmartStart inclusions both for
Z-Wave and Z-Wave Long Range nodes.
Use the Z-Wave SmartStart agent to add Z-Wave devices to your Z-Wave S2
network on a Control4 CORE controller without having to send the identify
sequence from the device.
To add the Z-Wave SmartStart agent:
- In the Agents view, click Add.
- Double-click the Z-Wave SmartStart agent to add it to the project.
To add a Z-Wave device using the SmartStart agent:
- In Agents, select Z-Wave SmartStart.
- Enter the DSK of the Z-Wave device. The device must support Z-Wave SmartStart protocols.
Other options in the Z-Wave SmartStart agent
The SmartStart tab in the Z-Wave SmartStart agent consists of a table
populated with entered device specific keys (DSK) and corresponding SmartStart
parameters.
DSK —DSK is used both for unique identification of the device and secure
key exchange or out-of-band authentication. Generally, its format can be one
of the following:
- 8 groups of 5 decimal characters separated by hyphens
- 16/18/22/26 groups of 2 hexadecimal characters separated by hyphens
Z-Wave SmartStart agent uses the first format (e.g. “11111-22222-33333-4444455555-66666-77777-88888”).
INCLUDE —There is an INCLUDE checkbox for each DSK. INCLUDE is used to
indicate if the device identified by the DSK must be included into the
network. In case that Include checkbox for corresponding DSK is not selected,
the Z-Wave protocol controller will not include the device when it detects its
presence.
PROTOCOLS —By clicking on Arrow under protocols, the SmartStart agent
displays a list of preferred protocols for SmartStart. This is a prioritized
list and is used to indicate the preferred protocols for inclusion, the first
element being the highest priority.
During a SmartStart inclusion, the protocol controller initiates the inclusion
with the protocol of highest priority that is supported by the device. This
option can be useful in case multiple protocols are supported by the device.
UNID —UNID is the SmartStart parameter which is used to advertise which
UNID has been assigned to the SmartStart entry. UNID is in the form “zw-
homeID-nodeID”. The UNID field indicates that the unique identifier is
assigned to the node. A non-empty value means that it is included in our
network + —Click on + to add another DSK in SmartStart list with its own
SmartStart parameters.
IMPORT DSK FILE —Click IMPORT DSK FILE to import device specific keys
from a file. In the file, one DSK must be in each line.
NOTE: If you use another window outside of Composer Pro and switch back,
and then need to enter text in the SmartStart agent, click to another tab like
System Design and back to refresh the agent.
NOTE: Bootstrapping Mode setting is not available for provisioning list
entries.
NOTE: Advanced Joining setting (selecting which keys shall be granted) is
not available for provisioning list entries.
NOTE: If the S2 Security Bootstrapping is handed-over by another
controller, check the INFO tab of the
Z-Wave SmartStart agent for a DSK/PIN input dialog.
Connecting Z-Wave device drivers to motorization, sensor or light drivers
To connect a Z-Wave device driver to a motorization, sensor or light driver:
-
In Connections under the Control/AV tab, select the Z-Wave device driver.
The Control & Audio Video Connections window will show the available connections. -
Click on the Control Output connection Door/Window Sensor and the available devices to connect appear below in the CONTACT_SENSOR Input Devices window.
-
Click and drag the contact sensor output in the upper window to the contact sensor input in the lower window. When a valid connection is available, the cursor changes and has a + symbol. Release the mouse button to make the connection.
When the Z-Wave devices are connected to the appropriate motorization, sensor
or light drivers, the UI will now show appropriate drivers to represent the
Z-Wave devices.
Now the Z-Wave device drivers must be connected to the Z-Wave controller and
identified in the project.
Available Devices
When the device is identified and added to the Z-Wave network, the Available Devices window will show the device online with a green icon. A Z-Wave device that is added to the Z-Wave network and also identified to a device driver will show the device driver name and location next to the Node ID.
Z-Wave devices that are added to the Z-Wave network, but not identified to a device driver will show up with just the Node ID.
Removing Z-Wave devices
Z-Wave devices can be removed from any network at any time by using the Remove
button found in Available Devices. This is true even if they are not part of
the network performing the remove operation.
Removing Z-Wave devices from a previously installed network requires an
available ZWave controller and interaction with the Z-Wave device-usually by
pressing the ZWave button on the device. There is no “Remove from mesh” button
press sequence similar to ZigBee Pro devices.
Removing Z-Wave devices from the network
To remove a Z-Wave device from the network:
-
In Connections in the Z-Wave Network, click Remove in the Available Devices window.The Removing Z-Wave Device window appears and a 60 second timer starts.
-
Remove the Z-Wave device from the network according to the manufacturer’s instructions, usually by pressing a Z-Wave button on the device. See the documentation for the Z-Wave device for more information.
Note: If the device is not removed from the network before the timer ends, close the window and click the Remove button to try again. -
If the device was removed successfully, the timer will stop and the window will say the devices was removed from the network.
-
If the device is not removed from the network before the timer ends, close the window and click the Remove button to try again.
Removing failed Z-Wave devices
If a Z-Wave device has become lost or inoperable so that a physical button
press cannot be performed to remove it from the network, the Remove Failed
option is provided. Remove Failed is used to force a Z-Wave device off of the
network.
Important! Do not use this option if the device is operational. Use this
option only if a device has physically failed and is inoperable!
To remove a failed Z-Wave device:
- In Connections under Z-Wave Network, right-click on the Node ID of the failed Z-Wave device, and select Remove Failed.
- The controller will make one last attempt to communicate with the Z-Wave device. If the device successfully communicates, the Remove Failed will not proceed and the device must be removed using the Remove button instead. Remove the device according to the manufacturer’s instructions, usually by pressing the Z-Wave button.
- If the communication attempt fails, the device will be removed from the network and will not be tracked as a Z-Wave node by the Z-Wave controller. Be aware that this device must now be reset to defaults before using the device again within the system. See the manufacturer’s instructions for more information.
Advanced concepts
Replication —Control4 controllers do not implement controller
replication. The controller will respond appropriately to replicate requests.
Basic Command Class —Control4 controllers allow controlling unknown
devices with the Basic Command Class (see Interoperability below). Control4
controllers “Do Nothing” when receiving Z-Wave Basic Command Class commands.
Interoperability —Control4 controllers allow adding unknown Z-Wave
devices through a “Z-Wave2 Universal” driver. When a device is connected to
this driver, it can be controlled through the Basic Command Class using the
properties page for the device. Information reported from the device is also
be available on this properties page. Nonpreferred devices can also be added
to a Z-Wave mesh using the Available Devices Add button. This allows devices
to be added and then associated using manufacturer specific methods for doing
so. See manufacturer specific documentation on how to create associations on
specific devices.
Association Command Class —Control4 controllers implement associations on
the Lifeline association group (group 1). This association is used to provide
device reset information to an associated device. A single associated device
is supported.
Repeater Functionality —This product can be operated in any Z-Wave
network with other Z-Wave certified devices from other manufacturers. All
mains operated nodes within the network will act as repeaters regardless of
vendor to increase reliability of the network.
Using Z-Wave2 Universal Driver
Compatible devices —Features implemented in this driver should be supported for all Z-Wave certified devices.
Driver Limitations
- Feature support is limited only on SDK UCL MQTT topics
- No Z-Wave Scene cluster support
- No OS 3.3.0 color support
Supported Control Transports —This driver communicates via Control4 ZWave
server.
Control Transport Configuration —This driver will be automatically bound
after installation.
Quick Configuration
To add the Z-Wave2 Universal Driver:
- In Composer Pro System Design view, search for “ZWave2 Universal” in the Items tab.
- Double-click to add the driver to the project.
To add (discover) devices:
- In the Composer Pro Connections > Network > Z-Wave Network tab click Add button in the right corner.
- Discovered devices will appear under the Available Devices section.
- Connect discovered device with universal driver (use drag and drop).
- Verify successful connection-in the Properties tab, ZWave Status and Network Status should be populated
● ZWave Status: ONLINE
● Network Status: ONLINE (Online functional)
To remove devices:
- In Connections > Network > Z-wave Network, select the device and click Disconnect.
- Proceed with removing device as described in “Removing Z-Wave devices”.
Z-Wave2 Universal Driver Properties
In Composer, the Z-Wave2 Universal Driver Properties window consists of the following tabs:
-
Info—This tab displays following information about device:
o Status
o Network status
o Controller binding ID
o Controller status
o Manufacturer
o Manufacturer name
o Model
o Product ID
o UCL ID
o Type
o Power sourceClick the INTERVIEW button to discover the capabilities of a device that has been joined to the Z-Wave network. The capabilities show in INFO tab of Z-Wave2 Universal Driver. -
Clusters —This tab displays all clusters and their corresponding end points that are specified for device. By clicking on radio button with corresponding end point and cluster, driver will display all attributes and commands for that cluster which are obtained from MQTT. If device has writable attributes, they will be displayed with checkboxes in separate box. In order to change some of these attributes, it is necessary to select corresponding checkbox for that attribute firstly, enter new value and then click on “WriteAttributes” button.
-
Topics —This tab displays clusters and their topics sorted by end points in tree form. It’s possible to view content of payload for every topic by clicking on eye symbol.
-
Timeline —This tab displays table with latest topics that are received from MQTT in real time. It’s possible to clear timeline table by clicking on “Clear Timeline”.
-
Send —This tab allows to send manually entered payload for selected end point and command.
-
ZWave Status —This property holds information about status of the Zwave Agent and driver – agent connection. If this property is NOT set to ONLINE, there is a problem interfacing Control4 Zwave Agent.
-
Network Status —This property holds information about status of the Z-Wave network and the driver connectivity. If this property is NOT set to ONLINE (Online functional), there is a problem with Z-Wave network.
Table of Supported Command Classes
Command Class | Supported Version | Support | Control | Security Level | Comment |
---|---|---|---|---|---|
Association | 2 | + | + | Network Scheme | |
Association Group Info (AGI) | 3 | + | + | Network Scheme | |
Basic | 2 | + | N/A | ||
Battery | 3 | + | N/A | ||
Binary Sensor | 1 | + | N/A | ||
Binary Switch | 2 | + | N/A | ||
Central Scene | 3 | + | N/A | Partial control: |
1. Central Scene Notification is not available in the UI
Configuration| 4| | +| N/A|
Color Switch| 3| | +| N/A| Partial control:
1. Durations are ignored
2. No support for Start/Stop Level Change
3. No support for other Color Component IDs other than 0, 1, 2, 3, 4
Device Reset Locally| 1| +| | Network Scheme|
Door Lock| 2| | +| N/A| Partial control:
1. Configuration of Door Lock is not supported
Firmware Update| 7| +| | Network Scheme|
Inclusion Controller| 1| +| | Unencrypted|
Indicator| 3| +| +| Network Scheme|
Manufacturer Specific| 2| +| | Network Scheme|
Multi Channel| 4| | | N/A|
Multi Channel Association| 3| +| | Network Scheme|
Multi Command| 1| +| | Unencrypted|
Multilevel Sensor| 11| | +| N/A| Partial control:
1. Not all scales are supported
2. Not all types are shown in the UI
Multilevel Switch| 4| | +| N/A| Partial control:
1. The value 0xFF canniot be used in Multilevel Switch Set Commands
2. No Start/Stop Level Change
Meter| 6| | +| N/A| Partial control:
1. Meter Reset Command is not supported
Notification| 8| | +| N/A| Partial control:
1. No Push/Pull discovery is done
2. No Pull sensor support
3. Unknown types are not supported
4. No Regular probing is done
Powerlevel| 1| +| | Network Scheme|
Security 0| 1| +| | Unencrypted|
Security 2| 1| +| | Unencrypted|
Supervision| 2| +| | Unencrypted|
Thermostat Mode| 3| | +| N/A| Partial control:
1. Setting Thermostat Mode is not supported
Thermostat Setpoint| 3| | +| N/A| Partial control:
1. No discovery of ambiguous types in v1-v2
2. Only a few setpoints can be configured
3. Precision/size fields in the set are determined automatically by the
controller
Time| 1| +| | Unencrypted|
Transport Service| 2| +| | Unencrypted|
Version| 3| +| +| Network Scheme|
Wake Up| 3| | +| N/A|
Z-Wave Plus™ Info| 2| +| | Unencrypted|
Using supported command classes
Z-Wave Universal Driver has the following tabs: INFO, CLUSTERS, TOPICS, TIMELINE, SEND and WARNINGS. The INFO tab contains general information about the device. In the CLUSTERS tab, you can see all clusters and corresponding endpoints specified for the device. The TOPICS tab shows topics sorted by endpoints in the tree form. The TIMELINE tab displays a table with latest topics that are received from MQTT in real time. Z-Wave Universal Driver allows you to send commands by manually entering payload for selected endpoint and command using SEND tab.
NOTE: If you use another window outside of Composer Pro and switch back, and then need to enter text in the Driver Configuration view, click to another tab like Driver Properties and back to refresh the driver.
Association Command Class
CORE 3/CORE 5 controller partially controls Association Command Class. It
does not implement a UI which allows an end user to establish associations
between nodes.
Grouping Identifier | Maximum Number of Associations | Group Name | Usage/Trigger |
---|---|---|---|
1 | 10 | Lifeline | ZPC reset will issue a Device Reset Locally Command |
Association Group Information Command Class
CORE 3/CORE 5 controller partially controls Association Group Information
Command Class.
Basic Command Class
CORE 3/CORE 5 controller controls Basic Command Class. It is possible to set
and see the state of Basic Command Class.
To see the state of the Basic Command Class, navigate to CLUSTERS tab of the
Z-Wave universal Driver and choose OnOff cluster. The state is represented
with the small light bulb icon. When the color of the light bulb icon is grey,
the state of the included node is off. When the color of the light bulb icon
is white, the state of the included node is on.
To set the state of the Basic Command Class, use one of the available
commands: OFF, ON, TOGGLE.
Battery Command Class
CORE 3/CORE 5 controller controls Battery Command Class. It is possible to see
the current Battery level for the Battery supporting node.
To check the Battery Level Status, navigate to the CLUSTERS tab of the Z-Wave
Universal Driver and choose PowerConfiguration cluster.
The remaining percentage of the battery is displayed in
BatteryPercentageRemaining field.
If the Battery Level is too low, a warning message pops up in Z-Wave Universal Driver.
This warning can also be seen in the WARNINGS tab of Z-Wave Universal Driver. The message of the warning is: “The battery level is low. It needs to be replaced!”
To erase previous warnings, press the RESET button in the WARNINGS tab.
Binary Switch Command Class
CORE 3/CORE 5 controller controls the Binary Switch Command Class. It is
possible to set and see the current state of the Binary Switch supporting
node.
To send Binary Switch Set command, navigate to the CLUSTERS tab of the Z-Wave
Universal Driver and choose OnOff cluster. To trigger Binary Switch Set,
select one of three available buttons: OFF, ON and TOGGLE.
The state of Binary Switch is represented with the small light bulb icon. When
the color of the light bulb icon is gray, the Binary Switch is turned off.
When the color of the light bulb icon is white, the Binary Switch is turned
on.
Central Scene Command Class
CORE 3/CORE 5 controller partially controls Central Scene Command Class.
It is possible to see the number of Scenes that are supported by a Central
Scene supporting node. Also, it is possible to see the identifier of a current
scene.
To see the state of the Central Scene Command Class, navigate to the CLUSTERS
tab of the Z-Wave Universal Driver and choose Scenes cluster. Check SceneCount
field to see the number of scenes and CurrentScene to discover which scene is
currently active.
CurrentScene is a unique number derived from the combination of Scene
attributes. It is calculated as follow: Current Scene = ((SceneID – 1) * Max
Key Attribute) + (Key Attribute).
SceneValid field indicates if the Current Scene is active. More precisely, it
indicates if the current scene was activated within the last 5 seconds or is
being activated.
The CORE controller does not make received Central Scene Notification
available to the end user.
Configuration Command Class
CORE 3/CORE 5 controller controls Configuration Command Class. It is possible
to discover and set the parameter values and reset all configuration parameter
values to their default values.
To set the state of Configuration Command Class, you should navigate to the
CLUSTERS tab of Z-Wave Universal Driver and choose ConfigurationParameters
cluster. By choosing ConfigurationParameters cluster, you can see the list of
all the parameters that you can configure.
To set the parameter, choose the SetParameter command from the drop-down menu
and enter the ParameterID and desired Value that you want to set. Then, click
the SEND button.
It is possible to set the negative value of the parameter, if the value is within the predefined range for that specific parameter.When configuration of parameters is finished, you can check the parameter settings by clicking on show/hide eye icon.
If the connected device supports Configuration Command Class Version 1 or 2, you can initiate the discovery of the configuration parameters by using the DiscoverParameter command.
To send DiscoverParameter command from the Z-Wave Universal Driver, choose DiscoverParameter command from a drop-down menu and enter the configuration parameter ID which is expected to be supported by the supporting node. To send Default Reset All Parameters, navigate to the SEND tab of the Z-Wave Universal Driver and choose this command from a drop-down menu.
Color Switch Command Class
CORE 3/CORE 5 controller partially controls Color Switch Command Class. It is
possible to set the color of the Color Switch supporting node, however it is
not possible to send Start/Stop Level Change to the node. The controller can
display the last known state of the Color Switch supporting node.
To see the last known color state of the supporting node, navigate to the
CLUSTERS tab of Z-Wave Universal Driver and choose ColorControl cluster.
To change the color of Color Switch, choose
MoveToRGB command from a drop-down menu and adjust Red, Green, and Blue color
component.
Door Lock Command Class
CORE 3/CORE 5 controller partially controls Door Lock Command Class. It is
possible to set and see the Door Lock Mode of the nodes, however it is not
possible to configure Door Lock.
To see the state of Door Lock Command Class, navigate to the CLUSTERS tab of
ZWave Universal Driver and choose DoorLock cluster.
The current state of Door Lock is shown in LockState field.
To change the state of Door Lock, send one of the following commands:
LOCKDOOR, UNLOCKDOOR. ![Control4 C4 CORE3 Z Wave S2 Control USB Charger Insert
- Lock Command Class](https://manuals.plus/wp- content/uploads/2024/02/Control4-C4-CORE3-Z-Wave-S2-Control-USB-Charger- Insert-Lock-Command-Class.jpg)
Indicator Command Class
CORE 3/CORE 5 controller both support and control Indicator Command Class.
It is possible to send Identify command for a connected node by navigating to
CLUSTERS tab of Z-Wave Universal Driver, choosing Identify cluster and
selecting Identify command from a drop-down menu. Then, enter the desired
value for IdentifyTime and click on the SEND button.
Also, you can use SEND tab of Z-Wave Universal Driver and set the desired
IdentifyTime.
Set the value to 2 to trigger the Identify command.
Meter Command Class
CORE 3/CORE 5 controller partially controls Meter Command Class.
It is possible to see the last reported value and different meter values of a node. The displayed values are rounded. To see the last reported value, navigate to CLUSTERS tab of Z-Wave Universal Driver and choose Metering cluster. Check Current Summmation Delivered field.
To see different metering values, navigate to CLUSTERS tab of Z-Wave Universal Driver and choose ElectricalMeasurement cluster. Check ActivePower, ClusterRevision, RMSVoltage and ReactivePower field.
Sending Meter Reset command is not supported.
Multilevel Sensor Command Class
CORE 3/CORE 5 controller partially controls Multilevel Sensor Command Class.
The controller can display Air Temperature readings in Celsius and Fahrenheit.
However, it is not possible to display Air Temperature readings in unknown
scale, Carbon Monoxide
readings in mol/m3 nor ppm or Time in seconds.
To see Air Temperature readings in Celsius and Fahrenheit, navigate to
CLUSTERS tab of Z-Wave Universal Driver and choose TemperatureMeasurement
cluster.
Multilevel Switch Command Class
CORE 3/CORE 5 controller partially controls Multilevel Switch Command
Class. It is possible to set and see the current level of Multilevel Switch
supporting node. Multilevel Switch supporting node is represented both with an
OnOff and a Level functionality.
To set the level of Multilevel Switch supporting node, navigate to SEND tab of
Z-Wave Universal Driver and choose MoveToLevel command. Then, enter desired
values for Level and TransitionTime.
It is possible to specify the 0xFF duration for Multilevel Switch Set Commands
by setting the TransitionTime to 1.
Notification Command Class
CORE 3/CORE 5 controller partially controls Notification Command Class. The
controller supports interviewing node supporting Notification Command Class.
Due to the diverse nature of the Notification states and events that can be
reported via the Command Class, information from Notification Command Class is
displayed in IASZone and OccupancySensing cluster of the Z-Wave Universal
Driver.
The OccupancySensing cluster will be shown as Occupied when receiving:
- Home Security – Motion Detection
- Home Security – Motion Detection with location
- Home Security – Intrusion
- Home Security – Intrusion (location provided)
- Access Control – Door window open
The OccupancySensing cluster will be shown as UnOccupied when receiving:
- Home Security – State Idle (Motion Detection)
- Home Security – State Idle (Motion Detection with location)
- Home Security – State Idle (Intrusion)
- Home Security – State Idle (Intrusion location provided)
- Access Control – Door window closed
The state of an IASZone cluster is shown in the ZoneStatus for the following type and events:
- Home Security – Motion detected -> Alarm2
- Home Security – Intrusion -> Alarm1
- Home Security – Tampering -> Tamper
|
---|---
It is not possible to send commands for the Notification Command Class.
Security 0 – Security 2 Command Class
CORE 3/CORE 5 controller supports Security 0 and Security 2 Command Class. The
set of granted keys is shown in the following table:
Security Class | Protocol |
---|---|
S2 Access Control | Z-Wave and Z-Wave Long Range |
S2 Authenticated | Z-Wave and Z-Wave Long Range |
S2 Unauthenticated | Z-Wave |
S0 | Z-Wave |
Thermostat Mode Command Class
CORE 3/CORE 5 controller partially controls Thermostat Mode Command Class. The
controller can display the last known state of Thermostat Mode supporting
node.
SystemMode represents the current mode of Thermostat Mode Command Class.
It is not possible to set the Thermostat Mode.
Thermostat Setpoint Command Class
CORE 3/CORE 5 controller partially controls Thermostat Setpoint Command Class.
The controller can change setpoint for a supported type.
To set the Thermostat Setpoint, navigate to the CLUSTERS tab of Z-Wave
Universal driver and choose Thermostat cluster. Then, enter the desired value
for Occupied Setpoint. If the desired value is within the allowed range, the
value of Occupied Setpoint will be changed.
The value of Occupied Setpoint will not change if you entered the value outside of allowed range.
Z-Wave Long Range
Control4 CORE controllers can operate as Z-Wave Long Range controllers. Nodes
can be included using Z-Wave Long Range.
Control4 CORE controllers do not support QR Code scanning. We use Z-Wave
SmartStart agent for inclusion.
In Z-Wave SmartStart agent, you can change the bootstrapping mode by clicking
on Arrow under Protocols and choosing desired preferred protocol for
inclusion.
Identify the controller using the Indicator command class
When sending the Indicator command class to the CORE controller, the Caution LED on the front of the controller blinks green. The on time, off time, and number of blinks can be specified in the parameters of the command class.
Troubleshooting
When joined to a network, a Z-Wave device will not join a different network. Z-Wave devices can be removed from any network at any time by using the Remove button found in Available Devices. This is true even if they are not part of the network performing the remove operation. If there appears to be trouble joining a device to a network, it is a good idea to either perform a reset defaults on the device, or explicitly perform a removal procedure, prior to attempting to add the device to the existing network. This ensures the device is not currently configured for another network prior to adding the device to the desired network.