EMERSON AVENTICS AS1 Distributors Instruction Manual

June 4, 2024
Emerson

EMERSON AVENTICS AS1 Distributors

About this documentation

These instructions contain important information for the safe and appropriate assembly and commissioning of the product.

  • Read these instructions carefully, especially chapter g 2. Safety instructions before you start working with the product.

Additional documentation

  1. Also follow the instructions for the other system components.
  2. Please also observe the generally relevant, statutory, and other binding regulations of European and national legislation, and the national regulations for accident prevention and environmental protection in your country.
Presentation of information
  1. Warnings
    In this documentation, there are warning notes before the steps whenever there is a risk of personal injury or damage to equipment. The measures described to avoid these hazards must be followed.
    Structure of warnings

    • Hazard type and source
      Consequences of non-observance

    • Precautions
      CAUTION
      Possible dangerous situation.
      Failure to observe these notices may result in minor injuries or damage to property.

  2. Symbols

    • Recommendation for the optimum use of our products.
    • Observe this information to ensure the smoothest possible operation.

Safety instructions

The product has been manufactured according to the accepted rules of current technology. Even so, there is a risk of injury or damage if the following general safety instructions and the specific warnings given in this instruction manual are not observed.

  1. Please read all these instructions carefully before working with the product.
  2. Keep these instructions in a location where they are accessible to all users at all times.
  3. Always include the operating instructions when you pass the product on to third parties.

Intended use

  • The product is exclusively intended for installation in a machine or system, or for combination with other components to form a machine or system. The product may only be commissioned after it has been installed in the machine/system for which it is intended.
  • Use is permitted only under the operating conditions and within the performance limits listed in the technical data. Only use compressed air as the medium.
  • The product is technical equipment and is intended for professional use only.
  • Intended use includes having fully read and understood these instructions, espe-cially chapter g 2. Safety instructions.

Personnel qualifications

  • All tasks associated with the product require basic mechanical, pneumatic, and electrical knowledge, as well as knowledge of the respective technical terms. In order to ensure operational safety, these tasks may only be carried out by quali-fied personnel or an instructed person under the direction of qualified personnel.
  • Qualified personnel are those who can recognize possible dangers and institute the appropriate safety measures, due to their professional training, knowledge, and experience, as well as their understanding of the relevant regulations per-taining to the work to be done. Qualified personnel must observe the rules relevant to the subject area.

General safety instructions

  • Observe the valid local regulations to protect the environment in the country of use and to avoid workplace accidents.
  • Only use AVENTICS products that are in perfect working order.
  • Examine the product for obvious defects, such as cracks in the housing or missing screws, caps, or seals.
  • Do not modify or convert the product.
  • Persons who assemble, operate, disassemble, or maintain AVENTICS products must not consume any alcohol, drugs, or pharmaceuticals that may affect their ability to respond.
  • The warranty will not apply if the product is incorrectly assembled.
  • Do not place any improper mechanical loads on the product under any circumstances.
  • Product warnings and information must be legible, i.e. not covered by paint, etc.

Safety instructions related to the product and technology

  • Lay cables and lines so that they cannot be damaged and no one can trip over them.
  • Do not operate the product in aggressive ambient air (e.g., solvent vapors).

Scope of delivery

  • 1x distributor as ordered
  • 1 set of operating instructions
  • Additionally in case of AS2, AS3:
    • 1x molded seal
    • 1x flat gasket

About this product

Distributors are components of air preparation units and are used to distribute compressed air. Pressure switches may be additionally mounted in flange and pipe connections. The following versions are available:

  • DIS: Standard distributor
  • DIC: Distributor with center infeed
  • DIN: Distributor with non-return valve
    The following table lists assignment to the air preparation units: Air preparation units| Version| Description| Circuit symbols

See g Fig. 1

---|---|---|---
AS1| DIS| 2-fold| I
 | DIN| Non-return valve, 1-fold| IV
AS2| DIS| 3-fold| II
 | DIC| 3-fold| II
 | DIN| Non-return valve, 1-fold| IV
AS3| DIS| 4-fold| III
 | DIC| 4-fold| III
 | DIN| Non-return valve, 4-fold| V
AS5| DIS| 2-fold| I
 | DIN| Non-return valve, 0-fold| VI

Assembly, commissioning and operation

Let the product acclimatize for several hours before commissioning, other- wise, water may condense in the housing.

CAUTION
Danger of injury if assembled under pressure or voltage!
Assembling when under pressure or electrical voltage can lead to injuries and damage to the product or system components.

  1. Make sure that the relevant system component is without pressure and voltage before you assemble the product.
  2. Protect the system against being restarted.

CAUTION
Sudden pressure increase during commissioning!
The system is exposed to sudden pressure on commissioning if no SSU filling unit is used! This may result in dangerous erratic cylinder motions.

  • Please ensure when commissioning a system without a SSU filling unit that the cylinders are in their end position or that no danger can emit from those not in end position.

CAUTION
System is operating under pressure!
Incorrect installation may damage the air preparation unit/apparatus and cause serious injury.

  • Before commissioning, check that all connections, ports, and maintenance equipment have been correctly installed.

Mounting fastening elements W01, W03, W04 and W05
Please heed figures g Fig. 7, g Fig. 6, g Fig. 8 and g Fig. 9.

Mounting the pressure sensor

On the AS5 series pressure sensors can only be flange-mounted.

  1. Flange mounting

  2. Remove the blanking screw (a).

  3. Insert the molded seal (b) in the seal channel (c) of the air connection.

  4. Place the pressure sensor (d) on the flange and screw it tight.

  5. Pipe connection (AS1, AS2, AS3)

  6. Remove the blanking screw (a).

  7. Close the double nipple (f) with the seals (e1+e2) and screw the double nipple (f) into the distributor.
    Notice: The double nipple (f) must be ordered separately, seals (e1+e2) are included with the double nipple.

  8. Screw the pressure sensor (g) onto the double nipple (f).

Mounting accessory components
  1. Pipe connection (AS2, AS3)
  2. Remove the blanking screw (a).
  3. Insert the flat gasket (h) in the seal channel (c) of the air connection.
  4. Screw in the accessory components (i) such as push-in fittings, connection pieces, multiple adapters.

Service and repairs

Cleaning and servicing

  • Close all openings with suitable safety devices so that no cleaning agent can enter into the system.
  • Never use solvents or aggressive detergents. Only clean the product using a slightly damp cloth. Only use water and, if necessary, a mild detergent.
  • Do not use high-pressure cleaners for cleaning.
  • Do not use compressed air for cleaning (blowing off) the air preparation unit or equipment.

Disassembly, exchange

CAUTION
Danger of injury in case of disassembly or replacement under pressure or voltage!
Disassembling or replacement when under pressure or electrical voltage may lead to injuries and damage to the product or system components.

  1. Make sure that the relevant system part is without pressure or voltage be-fore disassembling the product or exchanging parts.
  2. Protect the system against being restarted.

Disposal

Dispose of the product and condensate in accordance with the national regulations in your country.

Conversion and extension

CAUTION
Danger of injury in case of disassembly or replacement under pressure or voltage!
Disassembling or replacement when under pressure or electrical voltage may lead to injuries and damage to the product or system components.

  1. Make sure that the relevant system part is without pressure or voltage be-fore disassembling the product or exchanging parts.
  2. Protect the system against being restarted.
Change flow direction

On delivery the flow direction is from left (1, IN) to right (2, OUT). The following conversion on the product is necessary if the flow direction is to be changed:

  1. Distributor conversion
    On all components, the flow direction change is performed by rotating an installation by 180° around the vertical axis. The housing covers need to be changed for the purpose.

  2. Release the housing cover at the front and back.

  3. Re-attach the covers at the opposite sides with the cover bearing the AVENTICS logo facing to the front.

  4. Component conversion on the DIC
    Components with a flow direction from left to right need to be converted to change the flow direction on the DIC distributor with center infeed.

Troubleshooting

Malfunction Possible cause Remedy
Pressure/flow level is not reached or drops off slowly. Operating pressure
too low •   Set higher operating pres- sure

•   Check tubing diameter

 | Leak on tubing| Check tubing and tubing connections

Technical data

Maximum permissible pressure, temperature range, and thread connection are indicated on the products.

General data|
---|---
Mounting orientation| Any
Min./max. medium/ambient temperature

Further technical data can be

| -10 °C /+50 °C

found in our online catalog.

Appendix

Figures: View varies according to the series.

Fig. 1: Circuit symbols:

  • I = 2-fold;
  • II = 3-fold;
  • III = 4-fold;
  • IV = Non-return valve, 1-fold;
  • V = Non-return valve, 4-fold
  • VI = Non-return valve, 0-fold

EMERSON AVENTICS AS1 Distributors-fig4

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Emerson User Manuals

Related Manuals