Xijia SP1500 Pure Sine Wave Inverter User Manual
- June 17, 2024
- Xijia
Table of Contents
Pure Sine wave Inverter
User Manual SP1500
SERIES
SP2000 SERIES
SP2500 SERIES
SP3000 SERIES
Important Safety Instructions
As an AC power supply equipment, the inverter’s AC output is the same as the
household power plug’s. The inverter’s AC output should be treated with
caution; otherwise, there will be a risk of electric shock! When using, please
note the following:
Attentions:
- Connect the DC input according to the requirement strictly. The Power inverter has a relatively wide DC input range. Still, too high or too low DC input may cause problems even destroy the inverter.
- A reverse polarity connection will blow the fuses in the inverter and damage the unit.
- Do not expose the inverter to a humid, flammable, explosive, or dust environment.
- Keep the inverter out of children’s touch.
- It is recommended to connect the inverter input terminal to the battery. Calculate the minimum capacity of the battery (expressed in AH) in the following way: 5times of the rated power of the inverter/ battery voltage. If for testing purposes, the user should select DC power supply current at least twice greater than that of the inverter rated input to keep normal inverter operation. Using a DC power supply for testing may cause damage to the inverter.
- When the inverter works continuously, its surface may become very hot; please ensure the air ventilation clearance around the inverter is more than 10cm. Keep away from the material or device which may suffer from high temperature when the inverter is working. Do not install the inverter in an airproof location and keep enough space around the inverter.
- Connect the protective grounding to the ground. The cross-section of the wire should not be less than 4mm².
- The wire connection between the battery and the inverter should be less than 3m, and the current density should be less than 3.5A/mm² . At this time, the inverter is running at full load. If the wire length exceeds 3m, please reduce the current density.
- A fuse or breaker should be used between the battery and the inverter. The value of the fuse or breaker should be twice the inverter’s rated input current.
- Do not connect the battery charger or similar devices to the inverter’s input terminal.
- Do not put the inverter close to the flooded lead- acid battery because the terminals’ sparkle may ignite the hydrogen released by the battery.
- It’s an off-grid inverter. Do not connect the AC output terminals to the grid or electrical source; otherwise, the inverter may be damaged.
- This inverter can only be used singly in parallel connections. The series connection will damage the inverters.
- Risk of electric shock, don’t touch the output port when the inverter is working. The output is forbidden to connect to other power sources or grids; otherwise, the inverter will be damaged. The inverter must be turned off when connecting the load.
- Please do not attempt to repair the fault inverter by yourself; otherwise, it may lead to a severe accident. Don’t hesitate to get in touch with the manufacture’s engineer.
- SP power series is only suitable for civil applications, not for industrial applications.
Introduction
SP Power series is a pure sine wave inverter that can convert 12/24/48VDC to
220/230/240VAC (or100V/110/120VAC). Industrial design has a wide operating
temperature, high reliability, and high efficiency compared with civil design.
Simple appearance and lightweight make it easy to install and operate. The
wide input voltage range is ideal for solar system applications. This inverter
is especially suitable for civil applications, such as household emergency
lighting systems, vehicle-mounted systems, small field power supply, etc.
Features:
- Safe design with input and output electrical isolation
- Adoption of advanced SPWM technology, pure sine wave output
- LED &LCD indicators for fault status and working status
- Lower No-load consumption
- Max. efficiency up to 95%
- Input protection: Over voltage protection, low voltage protection
- Output protection: Overload protection, short circuit protection
- Over-temperature protection: Temperature-controlled Fan Ventilation; Inverter turns off automatically when overheating
Designations of models
Model| Input Rated Voltage| Output Voltage|
Maximizing Power Output
---|---|---|---
SP1500-12-220| 12VDC| 220/230/240 VAC| 1500W
SP1500-24-220| 24VDC| 220/230/240 VAC| 1500W
SP1500-48-220| 48VDC| 220/230/240 VAC| 1500W
SP1500-12-110| 12VDC| 100/110/120 VAC| 1500W
SP1500-24-110| 24VDC| 100/110/120 VAC| 1500W
SP1500-48-110| 48VDC| 100/110/120 VAC| 1500W
SP2000-12-220| 12VDC| 220/230/240 VAC| 2000W
SP2000-24-220| 24VDC| 220/230/240 VAC| 2000W
SP2000-48-220| 48VDC| 220/230/240 VAC| 2000W
SP2000-12-110| 12VDC| 100/110/120 VAC| 2000W
SP2000-24-110| 24VDC| 100/110/120 VAC| 2000W
SP2000-48-110| 48VDC| 100/110/120 VAC| 2000W
SP2500-12-220| 12VDC| 220/230/240 VAC| 2500W
SP2500-24-220| 24VDC| 220/230/240 VAC| 2500W
SP2500-48-220| 48VDC| 220/230/240 VAC| 2500W
SP2500-12-110| 12VDC| 100/110/120 VAC| 2500W
SP2500-24-110| 24VDC| 100/110/120 VAC| 2500W
SP2500-48-110| 48VDC| 100/110/120 VAC| 2500W
SP3000-12-220| 12VDC| 220/230/240 VAC| 3000W
SP3000-24-220| 24VDC| 220/230/240 VAC| 3000W
SP3000-48-220| 48VDC| 220/230/240 VAC| 3000W
SP3000-12-110| 12VDC| 100/110/120 VAC| 3000W
SP3000-24-110| 24VDC| 100/110/120 VAC| 3000W
SP3000-48-110| 48VDC| 100/110/120 VAC| 3000W
Wiring
Operation Steps:
Step 1: Turn the power switch of the inverter to OFF
Step 2: Disconnect the input breaker or the fuse between the inverter and
battery. Connect the battery terminals (‘+’ with the red line and ‘-‘ with the
black line). Do not connect the poles by contraries.
Step 3: Use the cable no less than 4mm² to connect the inverter’s
grounding terminal to the ground.
Step 4: Connect the plug of AC load to the inverter AC outlet
Step 5: Switch on the input breaker or the fuse between the inverter and
battery; turn on the power switch to start the inverter. If the blue indicator
is ON, turn on the loads one by one. Check the operation state of the
inverter and loads.
Step 6: If there are different loads, the loads with higher startup
current should be turned on first, such as television. After the loads work
stably, turn on the loads with a lower startup current, such as an
incandescent lamp.
Step 7: If the Fault indicator is red and the buzzer alarms when turning
on the devices, please immediately switch off the loads and inverter.
Functions
(1) Input rated voltage
12V system input voltage range is 10~15.5V;
24V system input voltage range is 20~31V;
48V system input voltage range is 40~62V。
(2) Fan Ventilation
When the heat sink temperature is higher than 5 0 ℃ or the internal
temperature is higher than 50℃ , the fan will turn on automatically.
When the heat sink temperature is lower than 40 ℃, and the internal
temperature is lower than 40℃ , the fan will turn off automatically.
(3) AC Outlet (optional) (4) LED & LCD indicator and Buzzer
LCD CODE indicator | LED indicator | Buzzer | Status |
---|---|---|---|
NONE | BLUE ON Red OFF | No Sounding | Output is normal |
2 | Blue ON Red ON | 2 beeps | Low DC Voltage |
3 | Blue ON Red ON | 3 beeps | High DC Voltage |
4 | Blue ON Red ON | 4 beeps | Overload |
5 | Blue ON Red ON | 5 beeps | **** Over-temperature |
6 | Blue ON Red ON | 6 beeps | Output voltage abnormal |
For example , SP1500-12-220 running in different states as below:
Protection
Protection and recover | Condition | Phenomenon |
---|---|---|
Parameter | 12V SERIES | 24V SERIES |
Over voltage
protection and recover| Input Voltage (T)| >15.5V| >31V| ****
62V| Red indicator ON Output is OFF
Buzzer sounds 3 Beeps
Low voltage
protection and recover| Input Voltage (T)| <10V| <20V| <40V| Red indicator ON Output is OFF
Buzzer sounds 2 Beeps
Over-tempera protection and recover| Tem(T)| T>100C| T>100C| **** T>100C| Red indicator ON Output is OFF
Buzzer sounds 5 Beeps
| | | The output is OFF after 10S
| | S>1.1Pe| Red indicator ON
| | | Buzzer sounds 4 Beeps
Overload protection and recover| S: Output power
Pe : Rated power| S>1.3Pe| The output is OFF after 3S
Red indicator ON
Buzzer sounds 4 Beeps
| | | The output is OFF after 1S
| | S>1.5Pe| Red indicator ON
| | | Buzzer sounds 4 Beeps
AC OUTPUT Abnormal (low voltage\high voltage\short circuit)| Red indicator ON Output is OFF
Buzzer sounds 6 Beeps
Troubleshooting
Faults | Possible reasons | Troubleshooting |
---|---|---|
LCD CODE indicator “2” Red indicator on Output is OFF Buzzer sounds 3 Beeps | ||
DC input under-voltage | Measure the DC input voltage if the voltage is lower |
than 10/20/40V. Adjust the input voltage to restore normally.
LCD CODE indicator “3” Red indicator on Output is OFF Buzzer sounds 3 Beeps|
DC input Over-voltage| Measure the DC input voltage if the voltage is
higher than 15.5/31/62V. Adjust the input voltage to restore normally.
LCD CODE indicator “4” Red indicator on Output is OFF Buzzer sounds 4 Beeps|
Overload| **** Reduce the number of AC loads. Restart the inverter.
LCD CODE indicator “5” Red indicator on Output is OFF Buzzer sounds 5 Beeps|
Over-temperature| When the heat sink temperature . exceeds 90℃ the inverter
resumes work.
Maintenance
The following inspections and maintenance tasks are recommended at least two times per year for best performance.
- Make sure no block on airflow around the inverter. Clear up any dirt and fragments on the radiator.
- Check all the naked wires to ensure insulation is not damaged for serious solarization—frictional wear, dryness, insects or rats, etc. Repair or replace some wires if necessary.
- Check and confirm that indicator and display are consistent with required. Pay attention to any troubleshooting or error indication. Take corrective action if necessary.
- Confirm that all the terminals have no corrosion, insulation damage, high temperature, or burnt/discolored sign, tighten terminal screws to the suggested torque.
- Check for dirt, nesting insects, and corrosion. If so, clear up in time.
- Check and confirm that the lightning arrester is in good condition. Replace a new one in time to avoid damaging the inverter/charger and even other equipment.
WARNING : Risk of electric shock!
Risk of electric shock! Before the above operations, ensure that all the power
is turned off. The electricity in the capacitance is completely discharged,
then follows the corresponding inspections.
Disclaimer
The warranty does not apply under the following conditions:
- Damage caused by improper use or use in an inappropriate environment
- Battery voltage exceeds the input voltage limit of the inverter
- Damage caused by working environment temperature exceeds the rated range
- Unauthorized dismantling or attempted repair
- Damage occurred during transportation or handling
- Damage caused by force majeure
Technical Specification
Item| SP1500-12-110| SP1500-12-220| SP1500-24-110| SP1500-24-220|
SP1500-48-110| SP1500-48-220
---|---|---|---|---|---|---
Rated Input Voltage| 12VDC| 24 VDC| 48 VDC
Input Voltage Range| 10 ~ 15 . 5 VDC| 2 0 ~ 31 VDC| 4 0 ~ 61 VDC
Input surge voltage| < 32 VDC| < 44 VDC| < 80 VDC
Output Voltage| 100VAC(±5%)
110VAC(±5%)
120VAC(±5%)| 220VAC(±5%)
230VAC(±5%)
240VAC(±5%)| 100VAC( ±5%)
110VAC( ±5%)
120VAC( ±5%)| 220VAC(±5%)
230VAC(±5%)
240VAC(±5%)| 100VAC(±5%)
110VAC(±5%)
120VAC(±5%)| 220VAC( ±5%)
230VAC( ±5%)
240VAC( ±5%)
Output Frequency| 50/60 ±0.1Hz
Output Continuous Power| 1500 W
Surge power| 3000W
Output Wave| Pure sine wave
Distortion THD| THD≤ 5% ①| THD≤ 3% ①| THD≤ 5% ①| THD≤ 3% ①| THD≤ 5% ①| THD≤ 3%
①
Max. Efficiency| 90%| 91%| 91%| 92%| 94%| 95%
No- load current| <0.3A| <0.6A| <0.2A| <0.3A| <0.1A| <0.2A
Binding post| Φ 8 mm
Dimension| 292 ×166 ×87mm
Mounting size| 281 ×85mm
Mounting hole size| Φ5.5 mm
Net weight| 2.9kg
Item| SP2000-12-110| SP2000-12-220| SP2000-24-10| SP2000-24-220|
SP2000-48-110| SP2000-48-20
---|---|---|---|---|---|---
Rated Input Voltage| 12VDC| 24 VDC| 48 VDC
Input Voltage Range| 10 ~ 15 . 5 VDC| 2 0 ~ 31 VDC| 4 0 ~ 61 VDC
Input surge voltage| < 32 VDC| < 44 VDC| < 80 VDC
Output Voltage| 100VAC(±5%)
110VAC(±5%)
120VAC(±5%)| 220VAC(±5%)
230VAC(±5%)
240VAC(±5%)| 100VAC( ±5%)
110VAC( ±5%)
120VAC( ±5%)| 220VAC(±5%)
230VAC(±5%)
240VAC(±5%)| 100VAC(±5%)
110VAC(±5%)
120VAC(±5%)| 220VAC( ±5%)
230VAC( ±5%)\
240VAC( ±5%)
Output Frequency| 50/60 ±0.1Hz
Output Continuous Power| 2000 W
Surge power| 4000W
Output Wave| Pure sine wave
Distortion THD| THD≤ 5% ①| THD≤ 3% ①| THD≤ 5% ①| THD≤ 3% ①| THD≤ 5% ①| THD≤ 3%
①
Max. Efficiency| 90%| 91%| 91%| 92%| 94%| 95%
No- load current| <0.35A| <0.65A| <0.2A| <0.35A| <0.15A| <0.25A
Binding post| Φ 8 mm
Dimension| 352 ×166 ×87mm
Mounting size| 341 ×85mm
Mounting hole size| Φ5.5 mm
Net weight| 3.5kg
Item| SP2500-12-110| SP2500-12-220| SP2500-24-110| SP2500-24-220|
SP2500-48-110| SP2500-48-220
---|---|---|---|---|---|---
Rated Input Voltage| 12VDC| 24 VDC| 48 VDC
Input Voltage Range| 10 ~ 15 . 5 VDC| 2 0 ~ 31 VDC| 4 0 ~ 61 VDC
Input surge voltage| < 32 VDC| < 44 VDC| < 80 VDC
Output Voltage| 100VAC(±5%)
110VAC(±5%)
120VAC(±5%)| 220VAC(±5%)
230VAC(±5%)
240VAC(±5%)| 100VAC( ±5%)
110VAC( ±5%)
120VAC( ±5%)| 220VAC(±5%)
230VAC(±5%)
240VAC(±5%)| 100VAC(±5%)
110VAC(±5%)
120VAC(±5%)| 220VAC( ±5%)
230VAC( ±5%)
240VAC( ±5%)
Output Frequency| 50/60 ±0.1Hz
Output Continuous Power| 2500 W
Surge power| 5000W
Output Wave| Pure sine wave
Distortion THD| THD≤ 5% ①| THD≤ 3% ①| THD≤ 5% ①| THD≤ 3% ①| THD≤ 5% ①| THD≤ 3%
①
Max. Efficiency| 90%| 91%| 91%| 92%| 94%| 95%
No- load current| <0.5A| <0.9A| <0.3A| <0.45A| <0.2A| <0.3A
Binding post| Φ 8 mm
Dimension| 402 ×166 ×87mm
Mounting size| 391 ×85mm
Mounting hole size| Φ5.5 mm
Net weight| 4.1kg
Item| SP3000-12-110| SP3000-12-220| SP3000-24-110| SP3000-24-220|
SP3000-48-110| SP3000-48-220
---|---|---|---|---|---|---
Rated Input Voltage| 12VDC| 24 VDC| 48 VDC
Input Voltage Range| 10 ~ 15 . 5 VDC| 2 0 ~ 31 VDC| 4 0 ~ 61 VDC
Input surge voltage| < 32 VDC| < 44 VDC| < 80 VDC
Output Voltage| 100VAC(±5%)
110VAC(±5%)
120VAC(±5%)| 220VAC(±5%)
230VAC(±5%)
240VAC(±5%)| 100VAC( ±5%)
110VAC( ±5%)
120VAC( ±5%)| 220VAC(±5%)
230VAC(±5%)
240VAC(±5%)| 100VAC(±5%)
110VAC(±5%)
120VAC(±5%)| 220VAC( ±5%)
230VAC( ±5%)
240VAC( ±5%)
Output Frequency| 50/60 ±0.1Hz
Output Continuous Power| 3000 W
Surge power| 6000W
Output Wave| Pure sine wave
Distortion THD| THD≤ 5% ①| THD≤ 3% ①| THD≤ 5% ①| THD≤ 3% ①| THD≤ 5% ①| THD≤ 3%
①
Max. Efficiency| 90%| 91%| 91%| 92%| 94%| 95%
No- load current| <0.5A| <1A| <0.4A| <0.6A| <0.2A| <0.4A
Binding post| Φ 8 mm
Dimension| 467 ×166 ×87mm
Mounting size| 456 ×87mm
Mounting hole size| Φ5.5 mm
Net weight| 5.1kg
① Test condition: Rated Input Voltage, Output Continuous Power, Resistive
load.
Environmental Parameters
Working Temperature | -20℃~ +45℃ |
---|---|
Storage Temperature | -35℃ ~ +70℃ |
Humidity | < 95%(N.C.) |
Enclosure | IP20 |
Altitude | < 5000 m ( Derating to operate according to IEC62040 at a height |
exceeding 1000 m)
Others
Dielectric Strength
Between DC input terminals and metal case: Test voltage AC50 0 V, 1 minute
Between AC output terminals and metal case: Test voltage AC15 0 0 V, 1 minute