- SN6 Series Catalog Sensors
- About this Documentation
- Notes on Safety
- Delivery Contents
- About This Product
- Product identification
- Transport and Storage
- Montage
- Commissioning
- Operation
- Disassembly and Exchange
- Service and Maintenance
- Disposal
- Extension and Conversion
- Troubleshooting
- Technical Data
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SN6 Series Catalog Sensors
Instruction Manual
SN6 Series Catalog Sensors
Operating instructions
Sensor, ATEX-certified
SN6
II 3G Ex nC nA IIC T4 Gc
II 3D Ex tc IIIB/IIIC T125°C Dc
-10 °C ≤ Ta ≤ 50 °C
R499050077/2017-08, Replaces: 03.2016, DE/EN/FR/IT/ES/SV
Dimensioned diagram SN6 sensor
Wiring diagram
SN6 sensor overview:
- pressure screw M16x1.5;
- center screw M3x35 pos.;
- electrical connector pos.;
- clamp mounting post.
Mounting orientation of the SN6 sensor
EU declaration of conformity
in accordance with ATEX Directive 2014/34/EU and
in accordance with the EMC directive 2014/30/EU
-
Apparatus model/Product: Proximity sensors, series SN6-ATEX
-
Name and address of the manufacturer: AVENTICS GmbH Ulmer Str. 4 30880 Laatzen, GERMANY
-
This declaration is issued under the sole responsibility of the manufacturer.
-
The object of the declaration Sensor REED, material numbers:
R412000823 -
The object of the declaration described above is in conformity with the relevant Union harmonization legislation: as referred to in the headlines of this document
-
References to the relevant harmonized standards used:
EN 60079-0: 2012-08-00
EN 60079-0 / A11: 2013-11-00
EN 60079-15: 2010-05-00
EN 60079-31 – 2014-07-00
II 3G Ex nC nA IIC T4 Gc
II 3D Ex tc IIIB/IIIC T125°C Dc
-10°C 5 Ta 5 +50°C
7. Additional information: The instructions in the Operation Manual are to be kept.
Signed for and on behalf of AVENTICS GmbH
We reserve the right to make changes to the declaration. Presently applicable
editions can be obtained upon request.
About this Documentation
Documentation validity
This documentation applies to the following products:
-
Sensor Series SN6 (ATEX) with the material number R412000823
This documentation is intended for installers, operators, service technicians, and systems owners. This document contains important information on the safe and appropriate assembly, operation, and maintenance of the SN6 series sensor and how to remedy simple malfunctions yourself. -
Read this documentation completely, especially chapter 2 „Notes on Safety“ on page 1 before working with the SN6 series sensor.
Additional documentation
The SN6 sensor is a system component. Also, follow the documentation for the
other system components.
Presentation of information
In this documentation, uniform safety instructions, symbols, terms, and
abbreviations are used. These are described in the following subsections.
Safety instructions
In this documentation, there are warning notices before the steps whenever
there is a danger of personal injury or damage to the equipment. The measures
described to avoid these hazards must be followed.
Safety instructions are set out as follows:
SIGNAL WORD
Type and source of risk
Consequences of non-observance
Measures to avoid these hazards
WARNING
Indicates a hazardous situation that, if not avoided, could result in death or
serious injury.
CAUTION
Indicates a hazardous situation that, if not avoided, could result in minor or
moderate injuries.
NOTICE
Indicates damage: the product or the environment may be damaged.
If this information is disregarded, the product cannot be used or operated
optimally.
Notes on Safety
About this section
The product has been manufactured according to the accepted rules of safety
and current technology. Even so, there is a risk of injury or damage if the
following general safety instructions and the specific warnings given before
the steps in this documentation are not observed.
- Read these instructions completely before working with the SN6 sensor.
- Keep these instructions in a location where they are accessible to all users at all times.
- Always include the relevant operating instructions when you pass the SN6 sensor on to third parties.
Intended use
- The SN6 sensor is only intended for industrial applications.
- Use is permitted only within the performance limits listed in the technical data.
- The sensor is to be used to detect magnetic fields in explosive areas.
Intended use includes having read and understood these instructions
completely, especially the section „Notes on Safety“.
Improper use
- The sensor must not be used for any application not stated in these instructions.
- The sensor must not be used under any operating conditions not stated in these instructions.
Personnel qualifications
Assembly and commissioning require basic electrical and pneumatic knowledge.
Assembly and commissioning may therefore only be carried out by qualified
electrical or pneumatic personnel or an instructed person under the direction
and supervision of qualified personnel.
Qualified personnel is those who can recognize possible hazards and institute
the appropriate safety measures due to their professional training, knowledge,
and experience, as well as their understanding of the relevant directives
pertaining to the work to be done. Qualified personnel must observe the rules
relevant to the subject area and have qualifications according to TRBS 1203.
General safety instructions
- Observe the local regulations to protect the environment in the country of use and to avoid workplace accidents.
- Do not change or modify the device.
- Only use the device within the performance range provided in the technical data.
- Do not place any improper mechanical loads on the product under any circumstances.
- The warranty will not apply if the system is incorrectly assembled.
- Observe the requirements in the installation regulations.
Safety instructions related to the product and technology
During assembly
- Make sure the relevant system component is not under pressure or voltage before assembling the product or when connecting and disconnecting plugs.
- Only qualified persons (trained specialists) are permitted to install the electrical connector.
- Observe the general technical rules for the selection and operation of devices.
- Take suitable measures to prevent unintended activation or impermissible interference.
- Do not place any mechanical loads, such as deflection, torsion, or impact loads, on the sensor. Install the sensor in a protected location.
During operation
- Only commission the sensor after it has been completely assembled, as well as correctly connected and tested.
- Observe the operating conditions and data imprinted on the relevant sensor or stated on its rating plate.
- Do not disconnect plugs or lines when the sensor is under voltage.
- Do not loosen any cables, lines, or valves if the system is under voltage or pressure.
ATEX – Information on explosion protection
The ATEX sensors from the SN6 series are certified and labeled according to
the enclosed declaration of conformity.
They can be used in areas
- with gases, mists or vapors in zone 2
- with flammable dust particles in zone 22
Explanations on identification
Information on the year of manufacture of the sensor can be found in the
5-digit date code, which is located on one of the sides next to the rating
plate. The first two digits
indicate the year and the last two digits indicate the week.
WARNING
The danger of an ignition source is due to impermissible operating
conditions, connections, and parameters.
Operating the sensor under impermissible operating conditions can result in an
explosion.
- Observe the permissible operating conditions, in particular, the ambient temperature and the mechanical protection for the device.
- Note the limited temperature range for ATEX conditions.
- Do not disconnect the electrical connector, plug connectors, and connecting cable from the sensor if it is under voltage.
- Do not disconnect the electrical connector from the sensor if it is under voltage.
- Only mount the SN6 sensor onto pneumatic valves or pneumatic cylinder valve units (from AVENTICS GmbH), which have been tested in compliance with the valid ATEX guidelines or qualified as devices without their own potential source of ignition.
- Observe the relevant Ex guidelines for installation, maintenance, and repair, especially EN 60079-14.
The device will lose its Ex approval if these instructions are not complied with.
Delivery Contents
- 1 x SN6 sensor (with electrical connector)
- 1 x set of operating instructions (R499050077)
About This Product
The SN6 sensor is a magnetic field switch with an electrical connector.
The SN6 sensor is a proximity sensor and is generally used to query the
position of the piston in pneumatic cylinders that are operated in explosive
atmospheres.
Switch operation is indicated by an illuminated diode in the SN6 sensor.
Product identification
Observe the product information on the product and packaging.
Transport and Storage
There are no special transport instructions for this product. Nevertheless, observe the information in section 2 „Notes on Safety“.
Montage
CAUTION
The danger of injury if assembled under pressure or voltage!
Assembling when under pressure or voltage can lead to injuries.
- Make sure that all relevant system parts are not under pressure or voltage before assembly.
Observe the following safety information during assembly:
- Observe the Ex guidelines EN 60079-14.
- The installation of electrical devices must be carried out in accordance with applicable national regulations and performed or supervised by an electrical specialist (in compliance with TRBS 1203 or equivalent).
- First, compare the information on the device with the information in the operating instructions before installation.
- Take special care that no dirt or other foreign particles come into contact with the electrical connector components or the sensor seal.
- Install the sensor protected against mechanical impact and UV light (depending on the requirements/operating conditions).
- Install cables with protection or provide for strain relief. To avoid short circuits and interruptions, prevent sharp bending in the connection cables and strands.
Installing the switch unit
- Loosen the center screw in the electrical connector.
- Loosen the electrical connector from the sensor.
- Place the sensor on the appropriate clamp mounting 3.
- Fasten the sensor to the clamp mounting with the mounting screw. Tightening torque for mounting screw: 1.5 Nm
- Ground the switch unit if you install electroconductive clamp mountings.
Connecting the cable
-
Disassemble the electrical connector.
-
Carefully remove the cable sealing ring and center screw.
The electrical connector is equipped with connection terminals that may be used as sleeve or flat terminals (screw-head terminals). Preferably use wire end sleeves for the sleeve terminals and cable lugs for the flat terminals. Assign the terminals as shown in the wiring diagram 2. -
When feeding the cables through, make sure you comply with the component order and their orientation 3.
-
Connect the cables (see Technical Data).
-
Carefully insert the center screw. Make sure that the seal seat under the screw head is not damaged. Tightening torque for the plastic screw: 2.5 – 3.75 Nm.
-
Place the electrical connector on the sensor. Make sure that the sealing surfaces on the sensor and electrical connector are not dirty and that the seal is in the correct position.
Tightening torque for the center screw: 0.6 + 0.1 Nm
Setting the switch unit
- Slide the clamp mounting on the pneumatic cylinder tie rod to set the appropriate switch position (piston position).
- Fasten the clamp mounting to the tie rod with two hexagonal socket-head screws.
- Check that the switch unit sits close to the cylinder.
High inrush current loads, such as those occurring with purely capacitive loads such as in capacitors, cables with a length greater than 20 m, or incandescent lamps, can be compensated for to a certain extent through the use of a series resistor. Here, the series resistors limit the maximum value of the switching current for the switch unit. Purely inductive loads should be protected by a recovery diode on the load. We recommend using protective circuits for capacitive and inductive loads, such as those from long cables and relays/contactors according to safety information R412013397.
Commissioning
Before commissioning, make sure that the device and the entire machine or system comply with the EMC directive.
Operation
The given values for switching current and voltage (see Technical Data) must not be exceeded.
Disassembly and Exchange
When ordering spare parts, including the ID number located on the devices
(label, rating plate).
If by loosening the center screw, the electrical connector has been separated
from the sensor five times, the electrical connector and the flat seal must be
exchanged for original spare parts.
Service and Maintenance
The described sensors are maintenance-free.
Disposal
Scrap the device in accordance with local regulations.
Extension and Conversion
Do not change or modify the device.
Troubleshooting
In the case of malfunctions, check the line connections and the operating
voltage.
If the malfunction continues, proceed as follows:
- Ensure that the device is not under pressure.
- Disconnect the device from the power supply and hand the defective unit over to a qualified person (see Personnel qualifications).
Technical Data
Voltage | 24 V DC ±10% / 230 V AC ±10% |
---|---|
Max. switching current | 100 mA |
Switching position | ± 0.1 mm |
Ambient temperature | –10°C to +50°C |
Protection class | IP65 |
Display (diode) | Color: Yellow |
Cable diameter | 4.0 – 6.7 mm |
Cable cross-section | 0.5 – 1.5 mm2 |
ATEX
Zone 2
Zone 22| II 3G Ex nC nA IIC T4 Gc
II 3D Ex tc IIIB/IIIC T125°C Dc
-10 °C ≤ Ta ≤ 50 °C
Further technical data can be found in our online catalog at www.aventics.com.
AVENTICS GmbH
Ulmer Straße 4
30880 Laatzen, GERMANY
Phone +49 (0) 5 11-21 36-0
Fax: +49 (0) 511-21 36-2 69
www.aventics.com
info@aventics.com
Further addresses: www.aventics.com/contact
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The given information does not release the user
from the obligation of their own judgment and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.
An example configuration is depicted on the title page. The delivered product
may thus vary from that in the illustration. Translation of the original
operating instructions. The original operating instructions were created in
the German language.
R499050077-BAL–001–AI/2017-08 Subject to modifications. © All rights reserved