INTRODUCTION
General Information
This manual is intended to describe the features and functionality in addition
to aiding in the planning, configuring, commissioning and maintaining of the
TC8619 Ethernet-over-T1/E1 multiplexer.
Product Description
The TC8619 is a 4 Channel Ethernet-over-T1/E1 multiplexer with built-in power
redundancy.
TC8619 can support either T1 or E1 upon the order. Extensive diagnostics
include DIP switches for T1/E1 Loopback and other application configuration
switches. Each unit also provides multiple LEDs for Alarm, Power, Vcc, T1/E1
Status, and Link and Duplex LEDs for each channel. The built-in sync mechanism
verifies both device and T1/E1 link operation. No other test equipment is
required for link and device verification. The TC8619 is compatible with
standard 100Ω T1 for copper line lengths up to
6000ft and up to 2.5km for 75Ω / 120Ω E1 (copper line length is the distance
between the TC8619 and the T1/E1 cross-connect). The T1/E1 uses an RJ-48
connector and the Ethernet channels use RJ-48 connectors. Optional BNC adapter
cable is available for 75 Ohm E1. Power is 12VDC standard or optional 24VDC,
-48VDC, 125VDC, or 115/230VAC with an external power cube. Optionally, a high
temperature version (-20°C to 70°C) and extreme temperature version (-40°C to
80°C) are also available.
Features
- 10/100 Base-T Ethernet with IEEE 802.1p support
- T1 Features:
- ESF Framing
- Supports Line Length up to 3000ft (T1)*
- E1 Features:
- PCM31C Framing
- Supports Line Length up to 2.5km
- Very Low Latency ~ 600μs
- LEDs for Link (L) and Duplex (D) (to monitor Ethernet status)
- LEDs for “SYNC”, “AMI”, “BPV”, “LOS”, “AIS”, “RAI”, “CRC” (to monitor each T1/E1 channel status)
- LEDs for “PWR A,” “PWR B,” “Vcc,” & “ALM” (to monitor each unit’s power supply and alarm condition status)
- Built-in Power Redundancy
- Diagnostic DIP Switches for T1/E1 Loopback test.
- Rack Mount or Stand Alone
Applications
The TC8619 offers an inexpensive, plug and play method for connecting Ethernet
devices over existing T1/E1 links. Popular applications include:
- Bridging Ethernet LANs over Existing T1/E1 Telecom Network
- Extending Ethernet Networks by Utilizing TDM Telecom Infrastructure (i.e. T1/E1 Landline, or T1/E1s/PDH/SDH Microwave Carrying T1/E1)
- Demarcation Between the Carrier’s and Customer’s Networks
- Bonded Transparent LAN Service
Specifications
Ethernet Capacity
Channels| 4 ports – 10/100 Base-T Ethernet Channels
Electrical
Ethernet Connectors| RJ-48F
T1/E1 Connector| RJ-48F
System
Bit Error Rate| 1 in 109 or better
Unit Status Indicators| PWR A, PWR B, Vcc
T1/E1 Status Indicators| ALARM, SYNC, AMI, BPV, LOS, AIS, RAI, CRC, RMT
Ethernet Status Indicators| Link (L) and Duplex (D)
Diagnostic Functions| T1/E1 Loopback
Power Source
Standard| 12VDC @300mA
Optional| 24VDC, -48VDC, 125VDC, or 115/230VAC
with an external power cube
Temperature
Operating| -10°C to 50°C
Optional Hi-Temp Version| -20°C to 70°C
Optional Extreme-Temp Version| -40°C to 80°C
Storage| -40°C to 90°C
Humidity| 95% non-condensing
Physical (Standalone Unit)
Height| (3.53 cm) 1.40″
Width| (18.14 cm) 7.20″
Depth| (24.89 cm) 9.80″
Weight| (0.9 Kg) 2.0 lbs.
Physical (Rack mount 1U “Pizza Box” with two cards)
Height| (4.45 cm) 1.75″
Width| (48.26 cm) 19.0″
Depth| (22.86 cm) 9.0″
Weight| (1.86 Kg) 4.1 lbs.
Installation
General Information
The installation section describes how to:
- Unpack the unit
- Ensure an optimum site location
- Install the power supply and dry contact connection
Unpacking
Before unpacking any equipment:
- Inspect all shipping containers for evidence of external damage caused during transportation
- Inspect for damage after it is removed from the containers
IMPORTANT Any claims concerning shipping damage should be made directly to the pertinent shipping agencies. Any discrepancies should be reported immediately to the Customer Service Department at TC Communications, Inc. at 949-852-1973.
Equipment Location
The TC8619 should be located in an area that provides adequate light, work
space and ventilation.
Important Avoid locating it next to any equipment that may produce electrical interference or strong magnetic fields, such as elevator shafts or heavy duty power supplies. As with any electronic equipment, keep the unit from excessive moisture, heat, vibration and freezing temperatures.
Power Supply
The TC8619 can be powered by external DC power. Available power options are 12
VDC, 24 VDC, -48 VDC, and 125 VDC. There are two terminal block connectors
labeled “PWR A” and “PWR B” only one is required to power up the unit. Since
each TC8619 card is equipped with a power redundancy capability, the power
LEDs on the front panel will light according to which power jack (A or B) is
connected. Both LEDs will light when power redundancy is utilized.
Important Read and only connect a supply voltage that corresponds to the type plate of your device. Make sure that the contact load capacity of the signal contact is not exceeded.
Dry Contact Alarm Relay (DCAR)
- A terminal block connector at the rear panel provides for the Dry Contact Alarm Relay. This relay can be used in NO (Normal Open) or NC (Normal Close) configuration.
- When used in NO (Normal Open) configuration, the relay will close if the unit loses power completely or the Alarm is on. The relay remains open during normal operation.
- When used in NC (Normal Close) configuration, the relay will open if the unit loses power completely or the Alarm is on. The relay remains close during normal operation.
System Start Up
Apply the power by plugging the power plug into a power jack (both PWR A & PWR
B for dual power units). After power is applied, all LEDs (except PWR & VCC
LEDs) will flash momentarily and the following LED status should be observed
from the front and back panels:
-
The Power “A” and/or “B” and VCC LEDs should be lit.
Note: TC8619 cards installed in the 1U rack chassis will not show the PWR A LED in the “On” lit state and will be Off. This is normal and the power to the card will be monitored by the VCC LED being “On” lit. -
The “ALM” and “SYNC” LEDs on the front panel will be flashing indicating that the T1/E1 connection is not established. This is normal when the T1/E1 connection has not been established.
System Configuration
The TC8619 has been pre-tested and set per factory specifications.
-
Front Panel
RJ48F connectors are provided on the front panel for Ethernet connections. -
Rear Panel
- Rear Panel (T1/E1 RJ-48F Connector & Pin Assignments)
An RJ-48F female connector is provided on the rear panel for the connection of the T1/E1 wire pairs. When viewing the RJ-48F connector, the left pair (Pin # 1 & 2) of the RJ-48F connector are for T1/E1 signal going into the TC8619 (receive), while the right pair (Pin # 4 & 5) of the RJ-48F connector are for the transmit signal coming out of the unit.
- Rear Panel (T1/E1 RJ-48F Connector & Pin Assignments)
-
Rear Panel DIP Switch Functions
The DIP switch functions on the TC8619 are described below. To activate the function, set the appropriate switch to the On (Down) position.
- LOCLB: Local T1/E1 Loopback. This switch (SW1) initiates the Local T1/E1 Loopback function.
- WRR: Weighted Round Robin Priority Scheduling. This switch (SW2) is used to configure the Ethernet priority scheduling mode. “On” for weighted round robin priority scheduling. “Off” for strict priority scheduling.
- INT CLK: Internal Clock. This switch (SW3) is used to setup the T1/E1 timing mode. “On” for internal timing mode. “Off ” for Rx loop timing mode.
- B8ZS/HDB3: This switch (SW4) is used to setup the T1/E1 Line Code. “On” for B8ZS (T1) or HDB3 (E1). “Off” for AMI.
- DIS ALM: This switch (SW5) is used to disable the audio buzzer and dry contact alarm relay. “On” (down) position disables the buzzer and relay. “Off” enables the buzzer and relay. “DIS ALM” dip switch should be in “Off” under normal condition.
- L1, L2, L3: These switches (SW6, SW7, & SW8) are used to set the T1/E1 cross-connect distance (copper line build-out).
For example, in a T1/E1 application, this is the length of twisted pair cable connecting the TC8619 to the user’s equipment, which may be a CSU or DSU. See Table 2-1.
Table 2-1: Copper Line Length Setup Table
T1 Settings
L3| L2| L1| Application Line Length
Off| Off| Off| DSX-1 (0 to 133 feet) / 0 dB CSU
Off| Off| On| DSX-1 (133 to 266 feet)
Off| On| Off| DSX-1 (266 to 400 feet)
Off| On| On| DSX-1 (400 to 533 feet)
On| Off| Off| DSX-1 (533 to 655 feet)
T1 Settings
On| Off| On| -7.5 dB CSU
On| On| Off| -15 dB CSU
On| On| On| -22.5 dB CSU
Table 2-2: E1 Termination Setup Table
E1 Settings
L1| L2| L3| Application Termination
Up| Up| Up| 75 Ohm Normal
Down| Up| Up| 120 Ohm Normal
Up| Up| Down| 75 Ohm High Loss
Down| Up| Down| 120 Ohm High Loss
Quick Start Guide
Introduction
The TC8619 is designed for quick and easy installation. First, configure the
unit for your specific application by setting the Line Code, and Line Length
DIP switches. Once configured, you can connect the Ethernet, T1/E1 signal
source and power.
Setup
- Set the appropriate Line Code for your application with the rear panel DIP switch SW4. “On” for B8ZS (T1) or HDB3 (E1). “Off” for AMI.
- For T1/E1 applications, set the appropriate T1/E1 Line Length with the rear panel DIP switch SW6, SW7, & SW8. It is set to “0-133 feet” by default
- Set the appropriate T1/E1 timing mode with rear panel DIP switch SW3. There should be one and only one clock source throughout the entire T1/E1 network. If two TC8619 units are connected back to back, one unit should set to “Internal” timing mode, and the other unit should set to “RX Loop” timing mode.
- Verify the Ethernet pin connections as well as the T1/E1 pin connections. After that, connect the two TC8619 units with a T1/E1 cable.
- Connect the Ethernet signal source to the TC8619 Port 1 RJ-48 connector.
- Verify the corresponding channel’s Ethernet Link LED is solidly lit to indicate that data is being received. If the Link LED does not light up solidly on a particular channel, it usually indicates incorrect connections at the Ethernet port.
Tutorial
Introduction
It is highly recommended to conduct bench tests before actual installation.
Bench testing allows the user to become familiar with all the functions and
features of the TC8619 in a controlled environment. Knowledge of these
functions and features will ease installation and troubleshooting efforts
later on. Loopback tests assist troubleshooting by helping in pinpointing the
source of errors The TC8619 is a sophisticated product designed with multiple
advanced technologies. Loopback tests have been implemented to test
independent components of it.
Latched Alarm
The front panel “ALM”, “BPV”, “CRC” and “SYNC” LEDs can display both current
and latched error conditions. For example, if the “ALM” LED is on, and “SYNC”
LED blinks twice, it indicates that there are two “T1/E1 sync loss” after the
last alarm reset. To reset the alarm, press and hold the “CLEAR ERROR” button
for 3 seconds until the “ALM”, “BPV”, “CRC”, and “SYNC” LEDs are flashing. The
alarm will reset after the “CLEAR ERROR” button is released.
See the table below for latched alarm definitions.
Table 4-1 Latched Alarm Definitions
LED | Normal | Current Error | Latched Error | Note |
---|---|---|---|---|
ALM | Off | Flashing Continuously | On | |
BPV | Off | Flashing Continuously | Blink | The number of blinks indicates the |
number of times the error condition happens. (Max. 3 Blinks)
CRC| Off| Flashing Continuously| Blink| The number of blinks indicates the
number of times the error condition happens. (Max. 3 Blinks)
SYNC| On| Flashing Continuously| Blink| The number of blinks indicates the
number of times the error condition happens. (Max. 3 Blinks)
Latched Alarm Clearing
Latched alarm is cleared automatically after 10 seconds by default. This
default setting can be changed using unit’s internal dipswitch SW2-3 and
SW2-4. *Please contact TC Communications technical support before opening the
unit to access the internal dipswitch.
Table 4-1: Latched Alarm Clear Times
SW2-3 | SW2-4 | Latched Alarm Auto Clear Time | Usage |
---|---|---|---|
OFF | OFF | 10 seconds (Default) | Use for general T1/E1 line stability |
monitoring.
Any specific T1/E1 error will be shown on the T1/E1 status LEDs: BPV, CRC, RAI, AIS, and SYNC.
ON| OFF| 1 hour| This is useful for verifying T1/E1 line condition after initial setup or T1/E1 setting changes.
User does not need to wait at the unit location and can check back within an hour to verify the T1/E1 line stability.
OFF| ON| 24 hours| This is useful for verifying T1/E1 line condition during off office hours. (Example: Overnight)
The unit will log T1/E1 errors for the past 24 hours.
ON| ON| 48 hours| This is useful for verifying T1/E1 line condition during off office hours. (Example: Over the weekends)
The unit will log T1/E1 errors for the past 48 hours.
T1/E1 Local Loopback Test
A T1/E1 Local loopback is used to test T1/E1 wiring and T1/E1 transceiver
functionality. It can be enabled by pushing both rear panel DIP switches SW1
to the “On” (down) position. The diagram below shows the T1/E1 signal flow and
related loopback path.
- The “ALM” LED should be flashing indicating the unit is in T1/E1 Loopback mode.
- The “LOS” LED should be off indicating that a valid T1/E1 signal is being received. If the “LOS” LED is flashing it means that the TC8619 is not receiving a valid T1/E1 or the T1/E1 cable is in question. Please reference Figure 2-3, TC8619 Rear Panel T1/E1 Connector & Pin Assignment, on page 2-5 for T1/E1 pinouts.
- The T1/E1 signal should be looped back to the Carrier/Service Provider or T1/ E1 tester. Please make sure a valid T1/E1 signal is being received.
- Upon successful completion of this test, please return dip switches SW1(LOCLB) to the Up (Off) position for normal operation of the TC8619 unit(s).
Troubleshooting
General
Alarm conditions occur whenever a T1/E1 sync “fault” condition is detected by
the TC8610-1. Under normal operation, PWR, Vcc, and SYNC LEDs should be lit.
All LEDs are OFF
If no LEDs are lit on the unit, check the DC power supply, connector plug,
and/or the power source. If the problem persists, contact the Technical
Support Department at TC Communications, Inc. @
949-852-1973.
Alarm LED
The ALARM LED will flash when the unit detects any error, such as T1/E1 loss
of frame (no SYNC) or T1/E1 loss of signal (LOS), or in any loopback modes. It
will light solidly to indicate a latched alarm condition.(See 4.2 for Latched
alarm)
Appendix A
Features
- 1U height (1.75″)
- Universal Power Supply Accepts 90V to 264V AC and 47 to 63 Hz AC
- Standard Power Supply is 12VDC, Optional 24VDC, -48VDC, 125VDC, or AC Power Supply Available
- Over Load & Short Circuit Protection
Description
The TCRM195 “Pizza Box” Rack Mount Card Cages hold up to 2 single multiplexer
type cards. It operates with one power supply. The AC power supply
automatically adjusts for 90V to 264V AC input and 47 to 63 Hz operation. The
DC power supply accepts 24VDC, -48VDC, or 125VDC input (Optional). The rack
assemblies are 19″ wide by 1.75″ high. The TCRM195 is 9″ deep.
Chassis Ground
The Stand alone and Rack mount chassis provide a connection point for chassis
ground with a dedicated chassis ground screw and lock washer. The chassis
ground screw is located on the rear side of the chassis. This chassis ground
connection point is available in case chassis ground is taken into design
consideration by the end user.
Push Button & LED Functions
CLEAR ERROR Button Description
The recent enhancements implemented on the TC8619 (Ethernet over T1/E1) will
make troubleshooting a much easier process. The alarm LEDs – BPV, CRC, and
SYNC – can now latch abnormal conditions until they are reset by the user.
These functions are realized in part by the newly added CLEAR ERROR push
button.
CLEAR ERROR Push Button Functions
- To reset the local unit’s alarm LEDs, hold down the “CLEAR ERROR” button for at least 3 seconds until you see the alarm LEDs flash in sequence.
LED Functions
- RMT: displays the remote unit’s LED status on the local unit
- BPV: displays bi-polar violation(s) for the ingress T1/E1 signal
- CRC: displays error(s) in data integrity (only for T1/E1 ESF frame and E1 built-in CRC)
- SYNC: displays frame locking for T1/E1 (ESF framing) or E1 (PCM31C framing)
The alarm LEDs – BPV, CRC and SYNC – all have a latching functionality to indicate the number of occurrences for each error. These LEDs will continuously flash at regular intervals until reset by the user. The behavior is noted here:
- When an LED blinks once, it indicates a single error has occurred once. When an LED blinks twice, it indicates the error has occurred twice. When the LED blinks 3 times, it indicates the error has occurred 3 or more times.
CSU Loop Operation
When the ISP transmits the CSU Loop Up Code towards the unit, the unit will
recognize the code and loop back the entire T1/E1 signal back towards the ISP.
Once the Loop Up condition is established, the unit alarm will be flashing and
the ISP may perform BER testing and other tests on the looped link. To cancel
the loop, the ISP must transmit the CSU Loop Down Code towards the unit.
Alternatively, disconnecting the T1/E1 cable will also cancel the loop.
Return Policy
To return a product, you must first obtain a Return Material Authorization
number from the Customer Service Department. If the product’s warranty has
expired, you will need to provide a purchase order to authorize the repair.
When returning a product for a suspected failure, please provide a description
of the problem and any results of diagnostic tests that have been conducted.
Warranty
Damages by lightning or power surges are not covered under this warranty. All products manufactured by TC Communications, Inc. come with a five year (beginning 1-1-02) warranty. TC Communications, Inc. warrants to the buyer that all goods sold will perform in accordance with the applicable data sheets, drawings or written specifications. It also warrants that, at the time of sale, the goods will be free from defects in material or workmanship. This warranty shall apply for a period of five years from the date of shipment, unless goods have been subject to misuse, neglect, altered or destroyed serial number labels, accidents (damages caused in whole or in part to accident, lightning, power surge, floods, fires, earthquakes, natural disasters, or Acts of God.), improper installation or maintenance, or alteration or repair by anyone other than Seller or its authorized representative. Buyer should notify TC Communications, Inc. promptly in writing of any claim based upon warranty, and TC Communications, Inc., at its option, may first inspect such goods at the premises of the Buyer, or may give written authorization to Buyer to return the goods to TC Communications, Inc., transportation charges prepaid, for examination by TC Communications, Inc. Buyer shall bear the risk of loss until all goods authorized to be returned are delivered to TC Communications, Inc. TC Communications, Inc. shall not be liable for any inspection, packing or labor costs in connection with the return of goods. In the event that TC Communications, Inc. breaches its obligation of warranty, the sole and exclusive remedy of the Buyer is limited to replacement, repair or credit of the purchase price, at TC Communications, Inc.’s option.
To return a product, you must first obtain a Return Material Authorization (RMA) number and RMA form from the Customer Service Department. If the product’s warranty has expired, you will need to provide a purchase order to authorize the repair. When returning a product for a suspected failure, please fill out RMA form provided with a description of the problem(s) and any results of diagnostic tests that have been conducted. The shipping expense to TC Communications should be prepaid. The product should be properly packaged and insured. After the product is repaired, TC Communications will ship the product back to the shipper at TC’s cost to U.S. domestic destinations. (Foreign customers are responsible for all shipping costs, duties and taxes [both ways]. We will reject any packages with airway bill indicating TC communications is responsible for Duties and Taxes. To avoid Customs Duties and Taxes, please include proper documents indicating the product(s) are returned for repair/retest).
Limitation of Liability
- In no event shall the total liability of TC COMMUNICATIONS, INC. to purchaser and/or end user for all damages including but not limited to compensatory, consequential and punitive damages, exceed the total amount paid to TC Communications, Inc. by purchaser for the goods from which the claim arose, in no event shall TC COMMUNICATIONS, INC. be responsible for indirect and consequential damages.
- In no event shall liability attached to TC COMMUNICATIONS, INC. unless notice in writing is given to TC COMMUNICATIONS, INC. within ten days of the occurrence of the event giving rise to such claim.
- TC COMMUNICATIONS, INC. shall not be responsible for delays or nondeliveries directly or indirectly resulting from or contributed to by foreign or domestic embargoes, seizure, fire, flood, explosion, strike, act of God, vandalism, insurrection, riot, war, or the adoption or enactment of any law, ordinances, regulation, or ruling or order or any other cause beyond the control of TC COMMUNICATIONS, INC.
- TC COMMUNICATIONS, INC. shall not be responsible for loss or damage in transit and any claims for such loss or damage shall be filed by the purchaser with the carrier.
Trademarks
The TC Communications® logo is a registered trademark. JumboSwitch® is a
registered trademark of TC Communications. Other product and brand names may
be trademarks or registered trademarks of their respective owners.
Documentation Disclaimer
This document is provided “as-is” and is to be used only as a general guide.
TC Communications disclaims all warranties, express or implied, regarding the
accuracy of the information. TC Communications shall not be liable for any
indirect, special, incidental, or consequential damages (including damages for
loss of business, loss of profits, loss of business information, business
interruption or other pecuniary loss) arising out of errors in this document.
The information given in this document is reviewed regularly and any necessary
corrections will be included in subsequent editions. We appreciate any
suggested improvements. We reserve the right to make technical improvements
without notice. Dissemination or reproduction of this document, or evaluation
and communication of its contents, is not authorized except where expressly
permitted. Violations are liable for damages. All rights reserved,
particularly for the purposes of patent application or trademark registration.
This document contains proprietary information, which is protected by
copyright. All rights are reserved. No part of this document may be
photocopied, reproduced or translated to another language without the prior
written consent of TC Communications.
Record of Revisions
Revision Date Description of Changes
1.1| 07/07/2022 Initial Release of TC8619.
Guide to Alert Symbols
These alert symbols are used in Caution, Warning, and Danger notes.
TC Communications
17881 Cartwright Road
Irvine, California U.S.A. 92614
Tel. 949-852-1972
Fax 949-852-1948
E-Mail: sales@tccomm.com
Website: tccomm.com
17881 Cartwright Road – Irvine, CA 92614
TC Communications, Inc.
Tel: 949-852-1972
Fax: 949-852-1948
Web Site: www.tccomm.com
Email: sales@tccomm.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>