BEFORE YOU BEGIN

Please read and understand this entire manual before attempting to assemble, operate or install this appliance. If you have any questions regarding the product, please contact Customer Service:

This manual contains important information about the assembly, operation and maintenance of this LPG fire pit. General safety information is presented in the first few pages and is also located throughout this manual. Keep this manual for future reference and to educate new users of this appliance.

PACKAGE CONTENTS

Fire-Sense-63223-Parsons-Basketweave-Aluminum-Convertible-Gas-Fire-Pit-
Table-FIG-1 \(18\)

Also required but not included: AAA Battery (install by unscrewing the igniter button)

HARDWARE CONTENTS

Fire-Sense-63223-Parsons-Basketweave-Aluminum-Convertible-Gas-Fire-Pit-
Table-FIG-1 \(2\)

SAFETY INFORMATION

This appliance has been tested to and complies with the ANSI 221.97-2014, Outdoor Decorative Gas Appliances CGA CR 97-003 Outdoor Gas Fireplaces. The installation must conform to local codes or in the absence of local codes to the National Fuel Gas Code. ANSI 2223.1. This manual contains important information about the assembly, operation and maintenance of this fire pit. General safety information is presented in these first few pages and is also located throughout the manual. Keep this manual for future reference and to educate new users of this product. This manual should be read in conjunction with the labelling of the product. Safety precautions are essential when any mechanical or propane-fueled equipment is involved. These precautions are necessary when using, storing, and servicing. Using the equipment with the respect and caution demanded will reduce the possibility of personal injury or property damage. The symbols shown on this page are used extensively throughout this manual. Always heed these precautions, as they are essential when using any mechanical or propane-fueled equipment.

  • WARNING! Failure to comply with the precautions and instructions provided with this fire pit can result in death, serious bodily injury and property loss or damage from hazards of fire, explosion, burn, asphyxiation, and/or carbon monoxide poisoning. Only persons who can understand and follow the instructions should use or service this fire pit.
  • WARNING / DANGER WARNING/DANGER: indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
  • WARNING: Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
  • WARNING: Solid fuels shall not be burned in this appliance.
  • WARNING BURN HAZARD: Never leave the fire pit unattended when hot or in use. Keep out of reach of children.

DANGER EXPLOSION-FIRE HAZARD

  • Keep solid combustibles, such as building materials, paper, or cardboard a safe distance away from the fire pit as recommended by the instructions.
  • Provide adequate clearances around air openings in the combustion chamber. Never use the fire pit in spaces that do or may contain volatile or airborne combustibles, or products such as gasoline, solvents, paint thinner, dust particles, or unknown chemicals.
  • During operation, this appliance can be a source of ignition. Keep the fire pit area clear and free from combustible materials, gasoline, paint thinner, cleaning solvents and other flammable vapors and liquids. Do not use fire pit in areas with high dust content. Minimum fire pit clearances from combustible materials: 2 feet (24 inches) from the sides & 2 feet (24 inches) from the rear, 6 feet (72 inches) from the ceiling.
  • Never store propane near high heat, open flames, pilot lights, direct sunlight, other ignition sources or where temperatures exceed 120 degrees F (49 degrees C).
  • Propane vapours are heavier than air and can accumulate in low places. If you smell gas, leave the area immediately.
  • Never install or remove a propane cylinder while the fire pit is lighted, near flame, pilot lights, or other ignition sources or while the fire pit is hot to the touch.
  • This fire pit is red-hot during use and can ignite flammables too close to the burner. Keep flammables at least 6 feet (72 inches) from the top and 2 feet (24 inches) from the sides. Keep gasoline and other flammable liquids and vapours well away from the fire pit.
  • Store the propane cylinder outdoors in a well-ventilated space out of the reach of children. Never store the propane cylinder in an enclosed area (house, garage, etc.). If the fire pit is to be stored indoors, disconnect the propane cylinder for outdoor storage.

WARNING

  • This fire pit is fueled by propane gas. Propane gas is invisible, odourless, and flammable. An odorant is normally added to help detect leaks and can be described as having a “rotten egg” smell. The odorant can fade over time so leaking gas is not always detectable by smell alone.
  • Propane gas is heavier than air and leaking propane will sink to the lowest level possible. It can ignite by ignition sources including matches, lighters, sparks, or open flames of any kind many feet away from the original leak. Use only propane gas set up for vapour withdrawal.
  • Store or use propane gas in compliance with local ordinances and codes or with ANSI/NFPA 58. Turn off propane when not in use.

DANGER FOR YOUR SAFETY – If you smell gas:

  1. Shut off the gas to the appliance.
  2. Extinguish any open flame
  3. If the odor continues, keep away from the appliance and immediately call your gas supplier or fire department.

WARNING
We cannot foresee every use that may be made of our fire pit. Check with your local fire safety authority if you have questions about fire pit use. Other standards govern the use of fuel gases and heat-producing products for specific uses. Your local authorities can advise you about these. If no local codes exist, follow the National Fuel Gas Code, ANSI 2223.1. In Canada, installation must conform to local codes. If no local codes exist, follow the current National standards of CANADA CAN/CGA-B 149.2.

WARNING: FOR OUTDOOR USE ONLY CARBON MONOXIDE HAZARD

  • This fire pit is a combustion appliance. All combustion appliances produce carbon monoxide (CO) during the combustion process. This product is designed to produce extremely minute, non-hazardous amounts of CO if used and maintained by all warnings and instructions. Do not block airflow into or out of the fire pit.

  • Carbon Monoxide (CO) poisoning produces flu-like symptoms, watery eyes, headaches, dizziness, fatigue and possibly death. You can’t see it and you can’t smell it. It’s an invisible killer. If these symptoms are present during the operation of this product get fresh air immediately!

  • For outdoor use only. Using this fire pit in an enclosed space can kill you. Never use this fire pit in an enclosed space such as a camper, tent, home, or other unventilated or enclosed area.

  • This fire pit consumes air (oxygen). Do not use it in unventilated or enclosed areas to avoid endangering your life.

WARNING: Improper installation, adjustment, alteration. service or maintenance can cause property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment.

ASSEMBLY

PREPARATION

Before beginning assembly, empty the contents of the carton and make sure all parts are present. Place all parts on a soft, level surface for assembly. NOTE: It is best to use TWO PEOPLE to assemble this gas fire pit. Estimated Assembly Time: 60 Minutes | DO NOT over-tighten hardware!

  1. Locate 4 Legs ©. Screw a Stud © into each of the 4 holes on the sides of each Leg. Making sure all Legs have the foot facing down, insert the Studs into the holes in the sides of the Side Panels 0 and End Panel €©. Using the diagram at right as a guide, attach each Panel and Leg using Washer/Spring Washer/Nut @/P/S on each Stud. Tighten loosely with Wrench V. (DO NOT completely tighten as you will need to adjust panels to ensure proper alignment.) When all Legs, Side Panels, and End Panel are joined, align the Door Panel © with the last 4 bare Studs and secure with a  Washer/Spring Washer/Nut @/®/© on each Stud. Tighten with a wrench. Once all Panels are attached to the Legs, tighten the Nuts with a Wrench.
  2. When Panels and Legs are secured, turn the assembled table base upside-down and rest it on the tops of the Legs. Attach Gas Tank Support Bar # to Side Panels D by aligning holes in the Gas Tank Support Bar with holes in the bottom of Side Panels.
    • ( NOTE: the rectangular loop attached to the Gas Tank Support Bar should face down, toward the top of the fire pit.) Insert Bolts P into the aligned holes as shown, then slide a Washer @ and Spring Washer ® onto each Bolt and secure with a Nut S. Tighten Nuts with Wrench.Fire-Sense-63223-Parsons-Basketweave-Aluminum-Convertible-Gas-Fire-Pit-Table-FIG-1 \(6\)
  3. Install Gas Tank Support Ring 0: locate Gas Tank Support Bare and Door©. Hook the brackets of the Gas Tank Support Ring onto the Gas Tank Support Bar.
    • ( NOTE: the Gas Tank Support Ring should be installed so its short arm is bent toward the top of the fire pit, away from the feet. Insert one bracket into the rectangular loop as shown.) Align the hole on the bent arm with the hole at inside of Door Panel F frame. Insert Bolt ® through aligned holes toward the bottom of the fire pit. Slide Washer @ and Spring Washer ® over Bolt ® and secure with NutS. Tighten with Wrench
  4. Place Table Top © upside down on a non-abrasive surface. Screw 4 Studs M into the holes on the Table Top with Screwdriver O. Carefully lift the upside-down assembled fire pit base and slide the holes at the top of the Legs over the Studs in the Table Top. Secure by placing a Washer/Spring Washer/ Nut @ on each Stud as illustrated. Tighten with Wrench V, then place Plastic Caps 0 over Nuts.
    • WARNING: This fire pit is constructed of aluminium, a relatively soft, flexible metal. Do not sit, stand, or lean heavily on the top of the fire pit, which can cause bending or warping.Fire-Sense-63223-Parsons-Basketweave-Aluminum-Convertible-Gas-Fire-Pit-Table-FIG-1 \(9\)
  5. When the Table Top has been secured to the assembled Table Base, carefully turn the table upright. Place the Burner B into the hole in the Table Top, with the controls turned toward the Door Panel. Unscrew the igniter button and insert a AAA Battery with a positive end facing out. Screw the button back onto the control panel.
  6. Pour the Fire Glass © around the Burner. Be careful not to obstruct pilot light housing. Put the Removable Burner Cover A on the Burner. When the fire pit is NOT in use or after use, when the fire pit has cooled COMPLETELY, cover it with the Protective Cover J. DO NOT PUT THE PROTECTIVE FIRE PIT COVER ON A HOT FIRE PIT.Fire-Sense-63223-Parsons-Basketweave-Aluminum-Convertible-Gas-Fire-Pit-Table-FIG-1 \(10\)
  7. Connect the hose and regulator to the cylinder. The propane gas and cylinder are sold separately. Use a standard 20lb propane cylinder only. Use this fire pit only with a propane vapour withdrawal supply system. See Chapter 5 of the standard storage and handling of liquefied petroleum gas, ANSI/NFPA 58. Your local library or fire department should have this book. Storage of an appliance indoors is permissible only if the cylinder is disconnected and removed from the appliance. A cylinder must be stored outdoors in a well-ventilated area out of the reach of children. A disconnected cylinder must have dust caps tightly installed and must not be stored in a building, garage or any other enclosed area. The maximum inlet gas supply pressure: is 250 PSI, and the minimum inlet gas supply pressure: is 5 PSI. The minimum hourly of 10,000 BTU is the required input rating for a fire pit for automatic operation at ratings less than the full input rating. The pressure regulator and hose assembly supplied with the appliance must be used The installation must conform with local codes, or in the absence of local codes, with national fuel gas code, ANSI Z223.1/NFPA54, natural gas and propane Installation Code, CSA B 149.1, or propane storage and handling code, B149.2.Fire-Sense-63223-Parsons-Basketweave-Aluminum-Convertible-Gas-Fire-Pit-Table-FIG-1 \(11\)

OPERATING INSTRUCTIONS

  • A dented, rusted or damaged propane cylinder may be hazardous and should be checked by your cylinder supplier.
  • Never use a propane cylinder with a damaged valve connection.
  • The propane cylinder must be constructed and marked by the specifications for LP gas cylinders of the
  • U.S. Department of Transportation (DOT) or the standard for cylinders, spheres and tubes for transportation of dangerous goods and commission, CAN/CSA-B339.
  • The cylinder must have a listed overfilling prevention device.
  • The cylinder used must include a collar to protect the cylinder valve.
  • Never connect an unregulated propane cylinder to the fire pit.
  • Attach regulator to cylinder. Complete attachment. Install cylinder.
  • Do not store a spare LP gas cylinder under or near this appliance; Never fill the cylinder beyond 80 percent full;
  • Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use.
  • Only install the type of dust cap on the cylinder valve that is provided with the cylinder valve. Another type of cap or plug may result in leakage of propane.

ATTENTION: THIS PRODUCT IS NOT FOR COMMERCIAL USE. IT IS INTENDED FOR RESIDENTIAL USE ONLY.

  • Do not sit or stand on this table.
  • Keep children away during assembly. This item contains small parts which can be swallowed by children.
  • Do not use it indoors or inside any enclosure.
  • Retain the assembly instructions for future reference.
  • Installer — please leave these instructions with the owner.

LEAK CHECK

  • WARNING!
    • Perform all leak tests outdoors.
    • Extinguish all open flames
    • NEVER leak test when smoking.
    • Do not use the fire pit until all connections have been leak-tested and do not leak.Fire-Sense-63223-Parsons-Basketweave-Aluminum-Convertible-Gas-Fire-Pit-Table-FIG-1 \(12\)
  1. Make 2-3 oz. of leak test solution (one part liquid dishwashing detergent and three parts water).
  2. Apply several drops of solution where the hose attaches to the regulator.
  3. Apply several drops of solution where the regulator connects to the cylinder.
  4. Make sure all valves are turned OFF.
  5. Turn the cylinder valve ON.

If bubbles appear at any connection there is a leak.

  1. Turn the cylinder valve OFF.
  2. If the leak is at the hose/regulator connection: tighten the connection and perform another leak test. If bubbles continue appearing, the hose should be returned to the place of purchase.
  3. If the leak is at the regulatory/cylinder valve connection: disconnect, reconnect, and perform another leak test. If you continue to see bubbles after several attempts, the cylinder valve is defective and should be returned to the cylinder’s place of purchase. If NO bubbles appear at any connection, the connections are secure.

NOTE: Whenever gas connections are loosened or removed, you must perform a complete leak test. Complete installation.

CAUTION
Do not attempt to operate until you have read and understand all General Safety Information in this manual, all assembly is complete, and the leak test has been performed.

DANGER! FOR OUTDOOR USE ONLY CARBON MONOXIDE HAZARD Never use this inside a house or other unventilated or enclosed areas. This fire pit consumes air (oxygen). Do not use in unventilated or enclosed areas to avoid endangering your life.
WARNING Very hot while in operation! Never lean over the fire pit while in use. Do not touch Table Top or burner Assembly while the fire pit is in operation. A fire pit will be hot after use. Handle with care. Wait until the fire pit has cooled down after use before placing the lid on the Table Top or touching any surfaces. Failure to follow these instructions may result in serious bodily injury.
WARNING FOR YOUR SAFETY: Be careful when attempting to manually ignite this fire pit. Holding the control knob for more than 10 seconds before igniting the gas will cause a ball of flame upon ignition.

OPERATION CHECKLIST:
For a safe and pleasant heating experience, review this checklist before each use:

  • I am familiar with the entire owner’s manual and understand all precautions noted.
  • All components are properly assembled, intact, and operable.
  • No alterations have been made.
  • All gas connections are secure and do not leak.
  • Wind velocity is below 10mph.
  • I understand the unit will operate at reduced efficiency below 40°F.
  • I understand the fire pit is for outdoor use (outside any enclosure).
  • There is adequate fresh air ventilation.
  • The fire pit is away from gasoline and other flammable liquids or vapours.
  • The fire pit is away from windows, air intake openings, sprinklers, and other water sources.
  • The fire pit is at least two (2) feet on all sides/front/back and six (6) feet overhead from combustible materials.
  • The fire pit is on a hard and level surface.
  • There are no signs of spider/insect nests in fire pit orifices.
  • All burner passages and air circulation passages are clear.
  • I understand children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid burns or clothing ignition.
  • I understand young children should be carefully supervised when they are in the area of the fire pit.
  • I understand clothing or other fabric material should not be hung from the fire pit or placed on or near the fire pit.
  • I understand that any guard or other protective device removed for servicing the fire pit must be replaced prior to operating the fire pit.
  • I understand installation and repair should be done by a qualified service person, and that the fire pit should be inspected before each use and at least annually by a qualified service person.
  • I understand that more frequent cleaning may be required as necessary and that the control compartment, burner, and circulating air passageways of the fire pit must be kept clean.
  • The fire pit is constructed of aluminium, a relatively soft/flexible metal, and I should not allow anyone to sit or lean heavily on the top of the fire pit, which can cause bending or warping

BEFORE TURNING THE GAS SUPPLY ON:

  1. Your fire pit was designed and approved for outdoor use only. Do NOT use it inside a building, garage, or any other enclosed area.
  2. Make sure surrounding areas are free of combustible materials, gasoline, and other flammable vapours or liquids.
  3. Ensure that there is no obstruction to air ventilation. Be sure all gas connections are tight and there are no leaks.
  4. Be sure the cylinder is clear of debris. Be sure any component removed during assembly or servicing is replaced and fastened before starting.

NOTE: This model has an Electronic Igniter and requires one AAA battery. Unscrew the IGNITER BUTTON to install.

BEFORE LIGHTING:

  1. Smell all around the unit area for gas. Be sure to smell near the floor, because gas is heavier than air and will settle to the lowest point. If you smell gas, shut off the gas to the appliance, extinguish any open flame, and if odour persists, call your gas supplier or the fire department.
  2. Fire pit should be thoroughly inspected before each use, and by a qualified service person at least annually. If relighting a fire pit, always wait at least 5 minutes.
  3. Inspect the hose assembly for evidence of excessive abrasion, cuts, or wear. Suspect areas should be leak tested. If the hose leaks, it must be replaced before operation. Only use the replacement hose assembly specified by the manufacturer.

DANGER! FOR OUTDOOR USE ONLY CARBON MONOXIDE HAZARD Never use this fire pit inside a house or other unventilated or enclosed areas. This fire pit consumes air (oxygen). Do not use it in unventilated or enclosed areas to avoid endangering your life.

WHEN THE FIRE PIT IS ON: The burner will display tongues of blue and yellow flame. These flames should not produce thick black smoke, indicating an obstruction of airflow through the burners. If excessive flame is detected, turn off the fire pit and consult the Troubleshooting section of this manual.

LIGHTING:
NOTE: Use only your hand to depress or turn the gas control knob. Never use tools. If the knob will not depress or turn by hand, DO NOT try to repair it. Call a qualified professional service technician. Force or attempted repair may result in fire or explosion and will void the warranty.

  1. Turn the control knob to the “OFF” position (Fig. A).
  2. Fully open LP cylinder valve. Note: For initial start or after any cylinder change, hold Control Knob IN for 2 minutes to purge air from gas lines before proceeding.
  3. Push in and turn the control knob counterclockwise to HIGH (Fig. B).
  4. While holding the control knob in, push the Electronic Ignition button to ignite the main burner. (The ignition will produce a soft snapping/crackling sound. If the fire pit does not light and there is no snapping sound, replace the battery.)
  5. After the fire pit lights, wait 45 seconds, then release the control knob.
  6. Observe the flame height when lit. Flame should reach between 3 and 13 inches in height. Overly short or tall flame can indicate a problem.
  7. To decrease the flame, turn the control knob clockwise to LOW (Fig. C). To increase the flame, turn the control knob counterclockwise to HIGH (Fig. B).
    • NOTE: If the burner fails to remain lit, close all valves and wait at least 5 minutes before attempting to light.Fire-Sense-63223-Parsons-Basketweave-Aluminum-Convertible-Gas-Fire-Pit-Table-FIG-1 \(14\)

SHUT DOWN:

  1. To extinguish the burner depress the control knob and turn it clockwise to OFF.
  2. Turn the cylinder valve clockwise to OFF and disconnect the regulator when the fire pit is not in use.

AFTER-OPERATION CHECKLIST:

  1. The gas control knob is in the OFF position.
  2. The gas tank valve is OFF.
  3. The gas line is disconnected.

CONVERSION TO NATURAL GAS

WARNING

  • Make sure all control knobs and cylinder valves are in the OFF position before converting.
  • This appliance is portable and configured for use with Liquid Propane (LP Gas), which is delivered via removable tanks (LP tanks and their use are covered elsewhere in this manual).
  • If a Natural Gas connection is available, the user may wish to change the gas delivery system to a more permanent Natural Gas Supply.
  • This appliance is certified for use with either Liquid Propane (LP Cas) or Natural Gas and comes complete with the necessary parts to convert the appliance for use with Natural Gas.
  • A Natural Gas hose and regulator are also required and are sold separately.
  • The conversion valves allow the use of Natural Gas without replacing the burners or the entire valve system.
  • The process of converting the burner from Propane to Natural Gas is relatively simple and can be accomplished by any handy homeowner.
  • We recommend, however, that a qualified gas technician do the conversion.
  • Your warranty may be voided if the conversion is improperly completed.
  • Please retain the parts supplied with the appliance and these instructions so the technician can do the conversion.

Orifice Chart

  • The different burner valves in this appliance have different BTU ratings.
  • The holes in the orifices are drilled to different sizes to allow the proper amount of gas to flow through them.
  • Please note the chart below to give an easy reference for the various orifice opening sizes for the different valves in the appliance.

Fire-Sense-63223-Parsons-Basketweave-Aluminum-Convertible-Gas-Fire-Pit-
Table-FIG-1 \(19\)

NG Hose and Regulator Conversion Tools Required:

  • Adjustable Wrench
  • WARNING: Make sure all appliance components are completely cooled and the gas supply is turned off and removed from the appliance before performing the conversion.
  • WARNING! To avoid the possibility of burns conversion should only be done when the fire pit is completely cool. Ensure the burner is turned off. Turn the gas off at the source and disconnect the appliance before beginning conversion.
  • WARNING! Fire Glass may have sharp edges. Wear safety glasses and gloves when handling.
  • WARNING! We recommend that the conversion be performed by a licensed gas fitter, and all connections must be leak-tested prior to operating the appliance.
  1. If desired, remove the Burner from the enclosure. (Remove the Fire Glass from the Burner first.) Take care not to damage or kink the Thermocouple Wire. Alternatively, you may wish to perform the conversion from below via the Tank Access Door.
  2. Disconnect the stainless steel Flex Line from the brass Connector Valve using two Wrenches.
  3. Unscrew the Connector Valve from the Burner Pipe.
  4. Slide the Air Shutter tube included in the conversion kit onto the Burner Pipe, covering the vent screens.
  5. Remove the small brass Propane Orifice from the burner end of the Connector Valve.
  6. Replace the Propane Orifice with the Natural Gas Orifice supplied. Fully tighten with a Wrench for a secure seal.
  7. Screw the Connector Valve back into the Burner Pipe. Fully tighten with a Wrench for a secure seal.
  8. Re-attach the Flex Line to the Connector Valve. Fully tighten with Wrenches for a secure seal.
  9. Place the Burner back into the enclosure if you removed it.
  10. Place the Conversion Label included with your Conversion Kit on the inside of the Tank Access Door.
  11. Replace the existing LPG hose and regulator with an NG regulator and hose (not included).
  12. Connect your gas supply and perform a Leak Test at each connection point. Leak Test instructions are found elsewhere in this manual.Fire-Sense-63223-Parsons-Basketweave-Aluminum-Convertible-Gas-Fire-Pit-Table-FIG-1 \(16\)

Natural Gas Hook-Up
The gas appliance is designed to operate at an inlet pressure of 7 inches water column. The piping up to the appliance is the responsibility of the installer. Connect the inlet valve to a rigid pipe, copper tube or an approved flexible metal connector, which complies with ANSI Z21.4/CSA 6.10. If using a gas hose (not supplied) connect the flanged end of the hose to the connector on the end of the inlet valve. Tighten using two wrenches. (Do not use thread sealer/pipe dope.) Leak test all joints before using the appliance. Piping and valves upstream of the quick disconnect are not supplied. The gas supply pipe must be appropriately sized to supply the BTU/hr specified on the rating plate, based on the length of the piping run. The quick disconnect must not be installed in an upward direction and a readily accessible manual shut-off valve must be installed upstream of, and as close to, the quick disconnect as is feasible. Purge the gas supply line of any trapped air before the first firing of the unit.

WARNING!

  • The installation must be performed by a licensed gas fitter, and all connections must be leak-tested before operating the appliance.
  • Ensure all hose connections are tightened using two wrenches. Do not use Teflon tape or pipe dope on any hose connection.
  • Ensure the hose does not contact any high-temperature surfaces or it may melt and leak causing a fire.
  • Locate the hose away from pathways where people may trip over it and areas where the hose may be subject to accidental damage.
  • Leak test all the connections using a soap and water solution as per the leak testing instructions found in the manual.

CARE & MAINTENANCE

To enjoy years of outstanding performance from your fire pit, make sure you perform the following maintenance activities regularly:

  1. Use warm soapy water for cleaning. Never use flammable or corrosive cleaning agents.
  2. While cleaning your unit, be sure to keep the area around the burner and control compartment dry at all times. Do not submerge the control valve assembly. If the gas control is submerged in water, do NOT use it. It must be replaced. Make sure the fire pit has cooled completely before cleaning or covering it with a cover.
    • A. Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapours and liquids.
    • B. Do not obstruct the flow of combustion and ventilation air.
    • C. Keep the ventilation opening(s) of the cylinder enclosure free and clear from debris.
  3. Air flow must be unobstructed. Keep controls, burner, and circulating air passageways clean. Signs of possible blockage include:
    • Gas odour with extreme yellow tipping of flame
    • The fire pit does NOT reach the desired temperature.
    • The fire pit glow is excessively uneven.
    • The fire pit makes a popping noise.
    • Spiders and insects can nest in burners or orifices. This dangerous condition can damage the fire pit and render it unsafe for use.
    • Clean burner holes by using a heavy-duty pipe cleaner. Compressed air may help clear away smaller particles.
    • Carbon deposits may create a fire hazard. Clean the burner screen with warm soapy water if any carbon deposits develop.
    • Note: In a salt-air environment (such as near an ocean), corrosion occurs more quickly than normal. Frequently check for corroded areas and repair them promptly.

STORAGE:

  • Between Uses:
    • Turn control knob OFF.
    • Disconnect LP source.
    • Store the fire pit in an area sheltered from direct contact with inclement weather (such as rain, sleet, hail, snow, dust and debris).
    • If desired, cover the fire pit to protect exterior surfaces and to help prevent build-up in air passages.

During periods of extended inactivity or when transporting:

  • Turn control knob OFF.
  • Disconnect the LP source and move to a secure, well-ventilated location outdoors.
  • Store the fire pit in an area sheltered from direct contact with inclement weather (such as rain, sleet, hail, snow dust and debris).
  • If desired, cover the fire pit to protect exterior surfaces and to help prevent build-up in air passages. Never leave the LP cylinder exposed to direct sunlight or excessive heat.
    • Note: Wait until the fire pit is cool before covering.
  • SERVICE: Only a qualified service person should repair gas passages and associated components.
  • Caution: Always allow the fire pit to cool before attempting service.

WARNING FOR YOUR SAFETY! Do NOT touch or move the fire pit for at least 45 minutes after use. The burner is hot to the touch. Allow the burner to cool before touching.

TROUBLESHOOTING

Fire-Sense-63223-Parsons-Basketweave-Aluminum-Convertible-Gas-Fire-Pit-
Table-FIG-1 \(17\)

LIMITED WARRANTY

Customers in the Contiguous US

  • With proof of purchase from an authorized retailer, this product is warranted for 1 year from the original purchase date against defects in materials and workmanship under normal use. This warranty does NOT cover normal wear/weathering, exposure to water, freezing temperatures, oils, fluids, or chemicals OR use in a commercial context if the unit is not designated as a commercial model. At Well Traveled Living’s sole discretion, products under warranty will be repaired and/or replaced at no charge to the customer.
  • Returns sent back to Well Traveled Living must be sent via prepaid freight in the original retail packaging.
  • For warranty service, contact Well Traveled Living at the address, phone number or website and email listed in this owner’s manual. Be sure to have your sales receipt, date of purchase and catalogue/model numbers available when calling.
  • All warranty service will be coordinated by Well Traveled Living’s, Amelia Island, Florida service centre. This warranty is extended only to the original owner. Proof of purchase will be required before warranty service is rendered.
  • The sales receipt is the only valid proof of purchase. This warranty only covers failures due to defects in materials or workmanship that occur during normal use. Failures and/or damage that result from accident, negligence, misuse, abuse, neglect, mishandling, alteration or modification, failure to maintain, improper assembly or maintenance, service by unauthorized agency or use of unauthorized components or damage that is attributable to acts of God are NOT covered.
  • This limited warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction.
  • The provisions of the United Nations Convention on Contracts for the Sales of Goods shall not apply to this limited warranty or the sale of products covered by this limited warranty.
  • THERE ARE NO EXPRESS WARRANTIES EXCEPT AS LISTED.
  • PURCHASER ASSUMES ALL RISKS IN THE ASSEMBLY AND OPERATION OF THIS UNIT.
  • FAILURE TO FOLLOW WARNINGS AND OPERATIONAL INSTRUCTIONS CONTAINED IN THIS MANUAL CAN RESULT IN SEVERE PROPERTY DAMAGE AND/OR PERSONAL INJURY.
  • IN NO EVENT WILL WELL TRAVELED LIVING, OR ITS DIRECTORS, OFFICERS OR AGENTS BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY, WHETHER IN CONTRACT, IN TORT, OR ON ANY OTHER BASIS, FOR ANY INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY, CONSEQUENTIAL, OR INCIDENTAL LOSS, COST, OR DAMAGE ARISING OUT OF OR IN CONNECTION WITH THE SALE, MAINTENANCE, USE, OR INABILITY TO USE THE PRODUCT, EVEN IF WELL TRAVELED LIVING OR ITS DIRECTORS, OFFICERS OR AGENTS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES, COSTS OR DAMAGES, OR IF SUCH LOSSES, COSTS, OR DAMAGES ARE FORESEEABLE. IN NO EVENT WILL WELL TRAVELED LIVING, OR ITS OFFICERS, DIRECTORS, OR AGENTS BE LIABLE FOR ANY DIRECT LOSSES, COSTS OR DAMAGES THAT EXCEED THE PURCHASE PRICE OF THE PRODUCT.
  • SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO THE PURCHASER.

EXTEND YOUR WARRANTY
When you purchase a Fire Sense or Balkene Home product from any authorized retailer, you’ll have peace of mind in knowing that it comes with a one-year warranty. Extend your warranty for an additional year when you review your item at balkenehome.com. within 365 days of purchase.

Important Notice: Do NOT return to place of purchase for customer service and warranty issues:

Fire Sense, Patio Sense,® Avalon Home,® Mojave Sun®” Vulcan,” Balkene Home® and Well Traveled Living® are registered trademarks of Well Traveled Imports, Inc. All assembly instruction presentations are the property of Well Traveled Imports, Inc.” and are protected by U.S. copyrights and trademarks. All rights reserved.

WARNING FOR YOUR SAFETY

  1. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
  2. Read the installation, operation, and maintenance instructions thoroughly before installing or servicing this equipment.
  3. Failure to follow these instructions could result in fire or explosion, which could cause property damage, personal injury, or death.

WARNING

  • For Outdoor Use Only

WARNING

  • This product can expose you to chemicals including Carbon Monoxide, Lead, Chromium (hexavalent compounds), Di(2-ethylhexyl) phthalate (DEHP) and Diisononyl phthalate (DINP), which are known to the State of California to cause cancer and birth defects or other reproductive harm.
  • For more information, go to www.P65Warnings.ca.gov.

Installation Precaution

  • This fire pit requires a minimum of 18 inches of cross-ventilation in all directions.
  • Failure to provide proper ventilation can void the warranty.

ATTACH YOUR RECEIPT HERE

  • Keep a copy of your proof of purchase or order confirmation which will be needed if you need to contact us about warranty coverage.
  • Purchase Date:
  • Conforms to ANSI STD Z21.97-2014,
  • Certified to CSA STD 2.41-2014 Outdoor decorative gas appliances
  • Contact us for assistance:

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Fire Sense User Manuals

Related Manuals