Overview

The MXA-RMK-20 Modero X Series® Rack Mount Kit (FG5969-60) is an optional accessory for the MXD-2000XL-PAN 20.3” Modero X Series Panoramic Wall/Flush Mount Touch Panel (FIG. 1). The kit allows the touch panel to be mounted directly on an equipment rack and includes a rack mount frame, screws and washers.

AMX-MXA-RMK-20-Rack-Mount-Kit-fig-1

Product Specifications

MXA-RMK-20 RACK MOUNT KIT (FG5969-60) SPECIFICATIONS

Dimensions (HWD):| 10.47” x 21.00” x 2.09” (26.59 cm x 53.34 cm x 5.31 cm)
Weight:| 4.30 lbs (1.95 Kg)
Included Accessories:| •   MXA-RMK-20 Installation Guide ( 93-5969-60 )

•   Rack Mount Panel, 20.3″ Modero Wall Touch Panel ( 62-5968-46 )

•   Screws, #10-32 PFH 1.75″ Long, Black (4) ( 80-5968-01 )

•   Screws, #6-32 x .375, PPH, Black (4) ( 80-0138 )

•   Washers, #6, Flat, 3/8 Diameter, .03 Thick, Stainless Steel (4) ( 80-0322-01 )

Other AMX Equipment:| •   MXD-2000XL-PAN 20.3” Modero X Series Panoramic Wall Touch Panel, Landscape Mount ( FG5968-11)

Installation of the MXA-RMK-20

The MXA-RMK-20 offers a stable installation mount for the MXD-2000XL-PAN through the panel’s Back Box.
NOTE: The MXA-RMK-20 Rack Mount Kit may only be used with the landscape mount of the MXD-2000XL-PAN touch panel (FG5968-11). It cannot be used with the portrait mount of the MXD-2000XL-PAN.
NOTE: All doors, covers, and other obstacles preventing installation of the Rack Mount Kit should be removed before installation is attempted. Due to the size of the Modero X Series panel, it may not be possible to close racks that contain a rack door, once installation is complete.

To install the MXA-RMK-20

  1. Secure the Rack Mount Panel to the rack with #10 screws. Make sure that the installation flanges (FIG. 2 and FIG. 3) face away from the front of the rack. The thinner flange of the Rack Mount Panel should be at the top (FIG. 1).

  2. Insert the Back Box into the Rack Mount Panel, making sure that the Back Box is in the correct orientation. The standups on the installation flanges will pass through the Back Box and help anchor it in place.

  3. Pass a washer through a #6 screw and insert it in a standup screw hole (FIG. 2). Repeat this procedure at each corner of the Back Box.AMX-MXA-RMK-20-Rack-Mount-Kit-fig-2
    WARNING: The maximum recommended torque to be used on the Back Box installation screws is 5 IN-LB [56 N-CM]. Applying excessive torque while tightening the screws, such as with powered screwdrivers, can strip out the screw holes or damage the plastic back box.AMX-MXA-RMK-20-Rack-Mount-Kit-
fig-3

  4. With the Back Box anchored in the Rack Mount Panel (FIG. 4), you may now install the MXD-2000XL-PAN into the Back Box.AMX-MXA-RMK-20-Rack-Mount-Kit-fig-4
    NOTE: For more information on installing the MXD-2000XL-PAN into its back box, please refer to the MXD/T-2000XL-PAN Operation Reference Guide, available from www.amx.com.AMX-MXA-RMK-20-Rack-Mount-Kit-
fig-4

A Note About Wall and Rack Installation
Some products are installed in areas of differing temperature and cooling methodologies. These include products installed in walls, racks, cabinets, etc. Those areas may have different temperatures and/or cooling approaches that must be taken into consideration to maintain the product within the specified operating temperature. FIG. 5 shows an AMX device installed in a wall with a filled volume (such as with insulation or concrete), as well as with a closed volume (such as between studs in an otherwise finished wall). The diagram shows how heat generated by the device or other devices may have no way to escape, and may build up to levels that may affect device operation

AMX-MXA-RMK-20-Rack-Mount-Kit-fig-5

In FIG. 6, the diagram displays an AMX device in a typical rack mounting, with full air circulation around the front and back of the device. In this case, the main concern is with heat building up between components, possibly to levels that may affect device operation.
AMX-MXA-RMK-20-Rack-Mount-Kit-fig-6

Installation Recommendations

During any installation, a lack of ventilation may produce conditions that may adversely affect the device’s operation. In these circumstances, special care must be taken to make sure that temperatures within enclosed areas do not exceed the device’s maximum rated temperature.

2015 Harman. All rights reserved. Modero X and Modero X Series, AMX, AV FOR AN IT WORLD, HARMAN, and their respective logos are registered trademarks of HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks of their respective companies. AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.

The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com. 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153 AMX (UK) LTD, AMX by HARMAN – Unit C, Auster Road, Clifton Moor, York, YO30 4GD United Kingdom +44 1904-343-100 www.amx.com/eu/

Download PDF: AMX MXA-RMK-20 Rack Mount Kit User Manual

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals