ikon IR-4-24 Gas Restaurant Ranges Instruction Manual

June 17, 2024
ikon

ikon IR-4-24 Gas Restaurant Ranges

ikon-IR-4-24 Gas-Restaurant-Ranges-PRODUCT

Specifications:

  • Models: IR-4-24, IR-6-36, IR-10-60, IR-6B-24MG-60, IR-6B-24RB-60, IR-6B-24TG-60
  • Total Input BTU/hr: See table for specific values
  • Shipping Crated Dimensions Weight Lbs/Kgs: See table for specific values

Product Usage Instructions

Important Safety Information:
This equipment is for use by qualified personnel only. Installation, operation, and maintenance should be carried out by individuals with the necessary expertise. Always follow the safety guidelines and instructions provided in the manual.

Model List & Description:
Refer to the model list provided in the manual to identify the specific range model you are using. Each model comes with a description detailing its features and specifications.

Installation:

  • Location: Install the appliance under a ventilation hood to ensure proper ventilation. Maintain adequate clearance for air openings into the combustion chamber and ensure there is enough room for air circulation to support gas combustion at the burners.

Gas Conversion:
If you need to convert the appliance from natural gas to LP gas, refer to the gas conversion instruction manual attached. The necessary orifices for conversion are provided. Check the orifice size list on page 3 when performing the gas conversion.

Maintenance and Care:
Proper maintenance is essential for the longevity and performance of your range. Follow the care instructions outlined in the manual to ensure optimal operation.

FAQ:

  • Q: Can I install the appliance myself?
    A: Installation should be carried out by qualified personnel to prevent property damage, injury, or hazards. It is recommended to seek professional installation services.

  • Q: How do I know if there is a gas leak?
    A: If you detect the smell of gas, follow the instructions provided in the manual for handling gas leaks. Contact your local gas supplier for assistance.

Models : IR-4-24, IR-6-36, IR-10-60, IR-6B-24MG-60 IR-6B-24RB-60 IR-6B- 24TG-60
WARNING : IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT

IMPORTANT FOR YOUR SAFETY

THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER.

Model List view

ikon-IR-4-24 Gas-Restaurant-Ranges-FIG- \(1\) ikon-
IR-4-24 Gas-Restaurant-Ranges-FIG- \(2\)

Orifice size & BTU

Description Pressure BTU per burner Orifice size

Top burner

| 5″(NAT)-24”36” / 6″(NAT)-60”| 30,000| #41
10″(LP)| 27,000| #53

Oven

| 5″(NAT)-24”36” / 6″(NAT)-60”| 33,000| #38
10″(LP)| 28,000| #53
Top griddle| 5″(NAT)-24”36” / 6″(NAT)-60”| 30,000| #39
10″(LP)| 27,000| #50

Top thermostat griddle

|

5″(NAT)-24”36” / 6″(NAT)-60”

|

30,000

|

34

10″(LP)| 27,000| #52
Top char broiler| 5″(NAT)-24”36” / 6″(NAT)-60”| 35,000| #36
10″(LP)| 35,000| #49

Installation, Operation and Care

PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE GENERAL
Ranges are produced with quality workmanship and material. Proper installation, usage and maintenance of your range will result in many years of satisfactory performance. suggests that you thoroughly read this entire manual and carefully follow all of the instructions provided.

WARNING
THIS APPLIANCE IS EQUIPPED FOR NATURAL GAS, for conversion to LP gas please see gas conversion instruction manual attached. Orifices necessary for LP (propane) (natural) conversion are provided. Please refer to page 3 the orifice size list when you do gas conversion

INSTALLATION

UNCRATING

  • This range was inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking, check for possible shipping damage.
  • If the range is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
  • Uncrate unit carefully and place in a work-accessible area as near to its final installed position as possible. Remove all shipping wire and wood blocking. Before installing, check the type of gas supply (natural or propane) to make sure they agree with the specifications on the rating plate located on the inside of the lower kick panel. If the supply and equipment requirements do not agree, do not proceed with the installation. Contact your dealer or company immediately.

LOCATION

  • The appliance must be installed under a ventilation hood.
  • The equipment area must be kept free and clear of combustible substances.
  • The range, when installed, must have a minimum clearance from combustible construction of 12″ (304 mm) at the sides and 10″ (253 mm) at the rear. Clearance from non-combustible construction is 0″ at the sides and 6″ (152 mm) at the rear. The installation location must allow adequate clearances for servicing and proper operation. A minimum front clearance of 40″ (1016 mm) is required.
  • The range must be installed so that the flow of combustion and ventilation air will not be obstructed. Adequate clearance for air openings into the combustion chamber must be provided. Make sure there is an adequate supply of air in the room to allow for combustion of the gas at the burners.

INSTALLATION CODES AND STANDARDS

Ranges must be installed in accordance with:

In the United States of America:

  1. State and local codes.
  2. National Fuel Gas Code, ANSI/Z223.1 (latest edition). Copies may be obtained from The American Gas Association, Inc., 1515 Wilson Blvd., Arlington, VA22209.

In Canada:

  1. Local codes.
  2. CSA B149.1 Natural Gas and Propane Installation Code.
  3. CSA C22.1 Canadian Electric Code.
  4. CSA C22.2 Canadian Electric Code.

The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6.
ASSEMBLY: Ranges Mounted on Casters

  • Ranges mounted on casters must use a flexible connector (not supplied by CHEF N’SAVE) that complies with the Standard for Connectors for Movable Gas Appliances, ANSI-Z21.69 • CSA 6.16 and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI-Z21.41 • CSA 6.9. In addition, adequate means must be provided to limit movement of the appliance without depending on the connector and the quick-disconnect device or its associated piping to limit appliance movement. Attach the restraining device at the rear of the range as shown in Fig. 1.
  • Remove two screws from the rear of the range and install the tie-down strap shipped with the casters using these screws (Fig. 1). Attach the gas line strain relief to the tie-down strap at the rear of the range (Fig. 1).
  • If disconnection of the restraint is necessary, turn off the gas supply before disconnection. Reconnect this restraint prior to turning the gas supply on and returning the range to its installation position.
  • Separate instructions for installing casters to the range are included with the casters.
    Note : If the range is installed on casters and is moved for any reason, it is recommended that the range be leveled front to back and side to side.

Backsplash
The standard Restaurant Range is equipped with a 23″ (584 mm) high backsplash and shelf.

  1. Remove the backsplash components from the crating materials.
  2. Assemble the required components as shown in Fig’s. 2 and 3 and 4.
  3. Tighten the four screws to secure the shelf.ikon-IR-4-24 Gas-Restaurant-Ranges-FIG- \(5\)
  4. Lift the assembly up, sliding the channels into the space provided at the rear of the range.(Figs. 5).ikon-IR-4-24 Gas-Restaurant-Ranges-FIG- \(6\)
  5. Install four #10 sheet metal screws (2 to each channel leg) (Fig. 6).ikon-IR-4-24 Gas-Restaurant-Ranges-FIG- \(7\)

LEVELING

  • Check the leveling of the range. Place a level inside the oven cavity across the oven rack(s). Level front-to-back and side-to-side.
  • To adjust the leveling, tilt the range to one side and, using channel locks, unscrew the adjustable leg insert as required. Repeat this procedure as necessary for each leg.
  • Optional casters for this range are of the non-adjustable type. Therefore, the floor must be level. If the floor surface is not level, the range will experience cooking problems.

GAS CONNECTIONS

CAUTION : All gas supply connections and any pipe joint compound used must be resistant to the action of propane gases.

  • Each range is factory-equipped for the type gas specified on the rating plate. The installation gas connection is a 3/4″ (19 mm) 14 FPT ANSI schedule #40 standard pipe. Connect gas supply. Make sure the pipes are clean and free of obstructions. Codes require that a gas shutoff valve be installed in the gas line ahead of the range. Standard ranges are equipped with fixed burner orifices that coincide with installation elevation. Install the gas pressure regulator.

  • Before installing, ensure that the regulator supplied agrees with the rating plate gas supply. The gas pressure regulator is NOT factory installed. The regulator for this gas type is sealed within a plastic bag attached to the oven rack inside
    the oven cavity. This regulator must be field installed by a qualified installer. Natural gas regulators are preset for 5″ W.C. (Water Column) (.99 kPa); propane gas regulators for 10.0″ W.C. (2.5 kPa)

    • Locate 3/4″ (19 mm) gas connection pipe extending from rear of the range.
    • Cover pipe threads with leak sealant.
    • Screw regulator hand-tight onto pipe with regulator arrow pointing towards range body back (Fig. 7).
    • Using pipe wrench, tighten the regulator securely in an upright position (Fig. 7).

The arrow on the regulator shows the direction of the gas flow. The pressure regulator must be mounted horizontally to ensure proper preset outlet pressure. If the regulator is installed in any other position, the outlet pressure must be reset for proper operation.
A leak limiter is supplied with every regulator to allow excess gas pressure to escape. Do not obstruct leak limiter on gas pressure regulator, as obstruction may cause the regulator to malfunction.
WARNING : BEFORE LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.
Before operation, verify thermocouple is securely seated in the safety valve.
The thermocouple should be tightened a 1/4 turn past finger tight. DO NOT OVERTIGHTEN. Over-tightening may damage the thermocouple or safety magnet.

TESTING THE GAS SUPPLY SYSTEM

When gas supply pressure exceeds 1/2 psig (3.45 kPa), the range and its individual shutoff valve must be disconnected from the gas supply piping system.
When gas supply pressure is 1/2 psig(3.45kPa) or less, the range should be isolated from the gas supply system by closing its individual manual shutoff valve until the range is ready for start-up.

FLUE CONNECTIONS

DO NOT obstruct the flow of flue gases from the flue located on the rear of the range. It is recommended that the flue gases be ventilated to the outside of the building through a ventilation system installed by qualified personnel.
From the termination of the flue to the filters of the hood venting system, a minimum clearance of 18″ (457 mm) must be maintained.
Information on the construction and installation of ventilating hoods may be obtained from the standard for the “Removal of Vapors from Commercial Cooking Equipment”, NFPA No. 96 (latest edition), available from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

OPERATION

WARNING: THE RANGE AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE RANGE.

CONTROLS THERMOSTAT DIAL
Allows operator to regulate oven temperature from low to 500° F (260° C)

(OPTIONAL) GRIDDLE BURNER KNOB
Regulates gas flow to the griddle. To increase heat, turn knob counterclockwise, to decrease heat, turn knob clockwise.

BEFORE FIRST USE

  • Griddle Seasoning (optional models)
  • CAUTION : This griddle plate is steel, but the surface is relatively soft and can be scored or dented by the careless use of a spatula or scraper. Be careful not to dent, scratch, or gouge the plate surface. Do not try to knock off loose food that may be on the spatula by tapping the corner edge of the spatula on the griddle surface.
  • A new griddle surface must be seasoned to do a good cooking job. The metal surface of the griddle is porous. Food tends to get trapped in these pores and stick; therefore, it is important to “season” or “fill up” these pores with cooking oil before cooking. Seasoning gives the surface a slick, hard finish from which the food will release easily.
  • To season, heat griddle top section at a low burner setting. Pour one ounce of cooking oil per square foot of surface over the griddle top section. With an insulated cloth, spread the oil over the entire griddle surface to create a thin film. Wipe off any excess oil with an insulated cloth.
  • Repeat this procedure 2 to 3 times until the griddle has a slick surface.

LIGHTING AND SHUTTING DOWN PILOTS

All adjustment procedures associated with pilot lighting must be performed by an authorized vendor installation or service person.

Manual GRIDDLE

  1. Turn the main gas supply ON.
  2. Wait 30 seconds and, using a long lighter, light the hot top or griddle top pilotikon-IR-4-24 Gas-Restaurant-Ranges-FIG- \(9\)
  3. If the pilot fails to light, turn the main gas supply OFF. Wait 5 minutes and repeat the above procedures.
  4. Turn one hot top or griddle top burner valve ON to remove air from the gas line. Turn the burner valve OFF when gas begins to flow.

Nightly Shutdown
Turn the burner valve OFF; the pilot will remain lit.

Complete Shutdown

  1. Turn the burner valve OFF; the pilot will remain lit.
  2. Turn the main gas supply OFF.

Thermostat GRIDDLE

  1. Turn the main gas supply ON.
  2. Locate the Pilot lighting door on the front of the unit to the left of the red pilot lighting button.
  3. Open the door and Insert a long lighter.ikon-IR-4-24 Gas-Restaurant-Ranges-FIG- \(11\)
  4. Press and hold the red pilot button while lighting the pilot. Once the pilot is lit hold the button for 30 seconds.
  5. Release button. The pilot should remain on.
  6. Close door.
  7. If the pilot fails to light, turn the main gas supply OFF. Wait 5 minutes and repeat the above procedures.
  8. Turn one hot top or griddle top burner valve ON to remove air from the gas line. Turn the burner valve OFF when gas begins to flow.
  9. Nightly Shutdown
  10. Turn the burner valve OFF; the pilot will remain lit.
  11. Complete Shutdown
  12. Turn the burner valve OFF; the pilot will remain lit.
  13. Turn the main gas supply OFF.

OPEN TOP BURNERS

  1. Turn main gas supply ON.
  2. Wait 30 seconds and, using a taper, light the open-top pilot
  3. If pilot fails to light, turn main gas supply OFF. Wait 5 minutes and repeat the above procedures.
  4. Turn one open top burner valve ON to remove air from the gas line. Turn the burner OFF when gas begins to flow.

Nightly Shutdown
Turn the burner valve OFF; pilot will remain lit.

Complete Shutdown

  1. Turn the burner valve OFF; pilot will remain lit.
  2. Turn the main gas supply OFF.

GRIDDLE (optional models)

  1. Turn the main gas supply ON. Wait 30 seconds and, using a taper, light broiler/griddle pilot.
  2. If the pilot fails to light, turn the main gas supply OFF. Wait 5 minutes and repeat Steps 1 and 2.
  3. Turn the burner valve ON to purge air from the lines. Turn the burner valve OFF when gas begins to flow.

Nightly Shutdown
Turn the burner valve OFF; the pilot will remain lit.

Complete Shutdown

  1. Turn the burner valve OFF; the pilot will remain lit.
  2. Turn the main gas supply OFF.

STANDARD OVEN LIGHTING AND SHUTDOWN INSTRUCTIONS

NOTE : Light open top/griddle pilots before lighting the oven pilot.

  1. Turn the thermostat to the “OFF” POSITION.
  2. Remove the lower panel.
  3. Depress the red button on the safety valve and light the pilot through the observation area.
  4. Hold down the red button for at least 30 seconds.
  5. When the button is released, the pilot should remain lit.
  6. Replace the lower panel.
  7. Turn the thermostat to the desired temperature.
  8. If the pilot becomes extinguished, Wait 5 Minutes, then repeat the above procedure.

Nightly Shutdown
Turn oven thermostat OFF.

Complete Shutdown

  1. Turn oven thermostat OFF.
  2. Turn main gas supply OFF.

RACK ARRANGEMENT -STANDARD OVEN
The standard oven has three rack positions and is supplied with one two oven racks. Additional racks may be obtained through a vender parts depot.

INSERTING AND REMOVING RACK

The oven rack has a stop to keep the rack from being pulled all the way out when unloading product. To install rack, place rack alongside of top of side liner runners and slide rack completely to the rear of the oven compartment until rack drops into place
To remove rack, reverse the procedure above by raising rear of oven rack stop above runner and pulling rack forward.

PREHEATING
Standard Oven Turn thermostat control to the desired cooking temperature and preheat oven for 25 minutes. To save on gas consumption, do not operate oven at maximum heat when it is not necessary. Turn thermostat down to 250°F (121°C) or OFF when oven is not in use or during idle cooking periods.

Griddle (optional models)
Turn the three manual gas valve knobs to full ON. After preheating for 5 minutes, turn valves down until desired flame or heating level is achieved. Position the removable broiler grid into one of the two slide positions, depending on which will achieve the proper product results.

CLEANING

  • Do not use scouring powder or abrasives anywhere on this range
  • Clean only using a soft cloth and mild detergent solution.

MAINTENANCE

WARNING : THE RANGE AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE RANGE.

VENT
When cool, the vent should be checked every six months for obstructions.

SERVICE AND PARTS INFORMATION
To obtain repairs, service and parts information concerning this model, contact supplier.
When calling for service, the following information must be available: model number, serial number, manufacture date (MD) and voltage (optional models).

IKON GAS RESTAURANT RANGES

We all recognize, however, that replacement parts and occasional professional service may be necessary to extend the useful life of this unit. When service is needed, contact a RANGE Authorized Service Agency, or your dealer. To avoid confusion, always refer to the model number, serial number, and type of your unit.

Description

ikon-IR-4-24 Gas-Restaurant-Ranges-FIG-
\(12\)

Key Part Number Q’ty Description
1 FS-302250151 6 Grate for hotplate
2 FS-302250034 6 Burner for hotplate
3 FS-302150041 6 #41 Natural orifice, hotplate
FS-302150042 6 #53 LP orifice,hotplate
4   6 Brass reducing nipple for Range Oven
5 FS-302220059 6 Manual gas valve A18
6 FS-302220027 3 Pilot Valve AP6 , for Hotplate
7 FS-03B00050 1 Oven thermostat
8 FS-03600125 1 Safety valve
9   1 Oven orifice
10 FS-309020069 1 Regulator, for 4&6 burner range
11 FS-03900080 1 Oven thermopile
12 FS-03510036 1 Oven pilot bracket
13 FS-302250035 1 Oven burner
14   1 Oven pilot tube

ikon-IR-4-24 Gas-Restaurant-Ranges-FIG- \(13\)

Key Part Number Q’ty Description
1 FS-100105 1 6B back splash
2   1 Shelf board
3   1 Front table
4 FS-301110405 6 Knob
5 FS-03900267 1 Oven thermostat knob
6 FS-100103 1 Oven door
7   2 Oven door hinge
8 FS-4000391 1 Oven radiant plate
9 FS-2660002 4 Caster set for 36″range
10   2 Chimney pillar support beam
--- --- --- ---
11 FS-20228062002 1 Front panel for 6B range
12 FS-303123917 1 Mylar for 6B range
13 FS-400040 1 Oven shelf bracket left
FS-400041 1 Oven shelf bracket right
14 FS-302090048 4 6″adjustable leg
15 FS-20228055008 1 Drop pan for 6B range
16 FS-400050 2 Oven shelf for 6&10 burner use
17 FS-20228055011 1 Oven drip pan 36″

TROUBLESHOOTING GUIDE

STANDARD OVEN RESTAURANT RANGE OVEN

PROBLEM CAUSES

1. Too much bottom heat

1a. Too low temperature 1b. Side burning

1c. Too much top heat

| a) Insufficient ventilation

b) Improper fluing

c) Improper thermostat bypass setting

d) Thermostat out of calibration

e) Fluctuating gas pressure

2. Uneven bake side to side

| a) Not level side to side

b) Oven burner, bottom or baffles improperly installed

c) Warped pans

3. Uneven bake front to rear

| a) Overactive flue

b) Not level front to back; check casters and legs

c) Door not closing properly

4. Dried out products

| a) Too low temperature (overcooking)

b) Too long baking time

c) Thermostat calibration

5. Pilot outage

| a) Pilot flame to low

b) Restriction in pilot orifice

c) Problem with shutoff valve

d) Possible fluing problems

e) Low pressure

f) Improper gas line sizing

g) Burner box cover not properly installed

h) Oven cavity requires resealing

TOP BURNER OPERATION

1. Improper burner combustion a) Improper ventilation
Excessive valve handle temperatures Sticking top burner valves b)

Poor door fit

c) Oven door left open

d) improper use of excessively large pans or pots

---|---

2. Poor ignition

| a) Insufficient input

b) Poor air-gas adjustment

c) Restriction in pilot orifice

d) Restriction in main burner ignition port

Limited Warranty

Products warrants to the original owner/user that any unit manufactured by Products (“the products”) shall be free of defects in material or workmanship under normal and proper use and maintenance service as specified by Products and upon proper installation (not to exceed 120 days from date of original shipment) and start-up by the instruction manual supplied with the Product.
The obligation of Products and the rights and remedies of the owner/user under this warranty are exclusively limited to (1) the repair or replacement, including labor charges, of parts or assemblies that in Product opinion are defective within one year after the original date of installation; The labor warranty shall include standard straight time labor charges at the product location only and shall exclude charges for travel time, mileage or other premium charges. Any labor service required to fulfill the warranty obligation must be performed by a service company qualified and accepted by BLUE FLAME Products.

This warranty does not include parts or labor coverage for component failure or other damage resulting from:

  • External electrical power failure or miswiring to Product for any reason.
  • Adverse operating conditions as outlined in the owner/user manual for the Product.
  • Failure to clean and/or maintain the Product as outlined in the owner/ user manual for the Product.

All claims for labor or parts must be made through Products. The defective part, for which labor reimbursement is claimed, together with the service invoice, must be returned to the Products within fifteen days from the date of service to be eligible for labor and parts warranty coverage. All replacement parts must be approved Product parts. Incidents of failure that do not require the replacement of a part shall be explained in sufficient detail on the service invoice to identify the failure. All claims shall include the product model number, serial number, original date of installation and customer identification.
The foregoing warranty shall not apply to (1) any part or assembly (a) that has been altered, modified, or changed, (b) that has been subjected to misuse, abuse, neglect or accidents, or (c) any Product on which the serial or model number has been removed or altered, or (2) any Product that has been installed and /or maintained inconsistent with Product’s technical publications, or
(3) any Product that has been installed or is located outside the standard warranty coverage area. Warranty valid in Continental United States only.

“LIMITATION OF LIABILITY AND OTHER WARRANTIES”

  • Products assume no liability for misuse or inadequate maintenance of the Product. In no event shall the user be entitled to recover incidental or consequential damages, including but not limited to, damages for inconvenience, food loss, rental or replacement equipment, loss of profits, or other commercial loss.

  • Warranties stated above are the only warranties made in connection with the sale and distribution of the Products. ANY AND ALL OTHER EXPRESSED, STATUTORY AND IMPLIED WARRANTIES APPLICABLE TO THE PRODUCT INCLUDING,
    WITHOUT LIMITATION, ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE EXPRESSLY DISCLAIMED.

  • The warranty information set forth above shall be governed by and construed by the laws of the United States of America. The warranty, as stated, is extended only to the original owner/user
    and is not assignable.

Conversion Kit Instructions for the Gas restaurant ranges
Models: IR-4-24, IR-6-36, IR-10-60, IR-6B-24MG-60,IR-6B-24RB-60,IR-6B-24TG-60

WARNING
This conversion kit shall be installed by a qualified service agency by the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, an explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The Installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.”

CONVERSION
Instructions are for conversion from Natural Gas to Propane (L.P.). The conversion should be done before connecting the unit to the gas supply. Units are shipped from the factory equipped for use on natural gas. Parts necessary for L.P. (liquid propane) are provided with the unit. Please refer to page 5 the orifice size list when you do gas conversion..
Turn off the main gas supply before doing any maintenance.

  1. Remove the grate

  2. Remove the top burner.

  3. Screw out the top burner air shutter screw

  4. Adjust the air shutter from half open to fully open, then screw in, and ensure fix well.

  5. Remove orifice

  6. Replace the orifice, burner
    Note : Unit Number on the side of orifice fittings

  7. Remove the drip pan, unscrew nut of the oven burner

  8. Incline the burner, expose the orifice of oven

  9. Replace the orifice fittings into the valve

  10. Screw out oven burner air shutter screw

  11. Replace the orifice and oven burner

  12. Adjust the oven burner air shutter from half-open to full-open. then screw in, ensure fix well

  13. Regulator conversion
    Before installing the included convertible regulator, unscrew the octagon cap. You can read (NAT) on the plastic insert attached to the head of the cap; flip it over and snap back in place.ikon-IR-4-24 Gas-Restaurant-Ranges-FIG-
\(23\)
    Regulator converts for 60”range change the part from R500 Nat 3”-6”W.C to R500 LP 11”W.C.

  14. Continue with installation.

  15. Attach gas conversion label on the appliance, the position below. Gas conversion label
    The position for gas conversionikon-IR-4-24 Gas-Restaurant-Ranges-FIG-
\(25\)

  16. Completed gas conversion.

Read User Manual Online (PDF format)