Introduction
The series of product is a new generation of multi-functional standalone
access control. It adopts
new ARM core 32-bit microprocessor design, which is powerful, stable and
reliable. It contains
reader mode and standalone access control mode etc.. It’s widely applied to
different occasions, such as office, residential communities, villa etc..
Features
Feature | Specification |
---|---|
Card Type | Read 125KHz EM Card and HID Card (Optional) |
Read 13.56MHz Mifare card and CPU card (Optional)
Keypad Characteristic| Operate by infrared remote
Output Way| Contain reader mode, the transmission format could be adjusted by
users
Access W| Support multi access ways: Card+Fingerprint, multi cards or multi
fingerprints
Admin Card/Fingerprint| Support admin card/admin fingerprint
User Capacity| 10,000 card users and 300 fingerprint users
Unlocking Signal| Relay NO/NC/COM output
Technical Specifications
- Operating Voltage: DC 12-24V: Standby Current: ≤ 35mA
- Operating Current: ≤100mA : Operating Temperature: -20℃~60℃
- Operating Humidity: 0%~95%: Electric lock signal relay contact current:≤1A
- Alarm signal MOS tube output current: ≤1A : Unlocking time: 0~300s adjustable
Installation
- Remove the back cover from the keypad using the supplied special screw driver
- Drill 2 holes on the wall for the self-tapping screws and hole for the cable
- Put the supplied rubber bungs to into the two holes
- Fix the back cover firmly on the wall with 2 self-tapping screws
- Thread the cable through the cable hole
- Attach the keypad to the back cover. (as following illustration)
Wiring
No. | Color | Marks | Description |
---|---|---|---|
1 | Green | D0 | Wiegand input (Wiegand output as reader mode) |
2 | White | D1 | Wiegand input (Wiegand output as reader mode) |
3 | Grey | ALARM | Alarm signal MOS tube drain output end (optional) |
4 | Yellow | OPEN/ BEEP | Exit button input end (Beeper input as reader mode) |
5 | Brown | D_IN/ LED | Door contact switch input end (LED input as reader mode) |
(optional)
6| Red| +12V| Positive power supply
7| Black| GND| Negative power supply
8| Blue| NO| Relay NO end
9| Purple| COM| Relay COM end
10| Orange| NC| Relay NC end
Diagram
Common Power Supply
Note: The door contact and alarm function are optional
Special Power Supply
Note: The door contact and alarm function are optional
**Reader Mode
**
Sound and Light Indication
Operation Status | Light indicator | Buzzer |
---|---|---|
Stand by | Red | |
Operation successful | Green | Beep— |
Operation failed | Beep-Beep-Beep | |
Admin card enter programming | Beep-Beep | |
Admin card exit programming | Beep— | |
Press digital key | Beep | |
Press * key | Beep— | |
Read card under fingerprint + code mode | Red indicator flash slowly | |
On process of reading multi user card | Red indicator flash slowly | |
Enter programming mode | Red indicator flash slowly | |
Enter setting status | Orange | |
Unlocking | Green | |
Buzzer alarm | Red indicator flash quickly | Alarm |
Admin Menu
Standalone Mode Settings
Device Management
=| Menu| Operation steps| Description| Default value|
---|---|---|---|---|---
| 0| New admin code # new admin code #| Change admin code| 999999|
* Press Admin code #| ** 1| 10001# Read card / Input a fingerprint
twice | Set admin add card or admin add fingerprint| |
10002# Read card / Input a fingerprint twice | Set admin delete card or admin
delete fingerprint| |
(Default admin code is “999999”)|
*** 2| 10001# | Delete admin add card or admin add fingerprint| |
10002# *| Delete admin delete card or admin delete fingerprint| |
| | 11 #| Standalone access control mode| |
| 3| 12 #| Relay toggle mode| 11|
13 #| Reader mode|
| | ( 26-58 ) #| Wiegand 26-58 bits output|
8| 8 #| WIFI matching| Optional|
Add and Delete Users
-
Read admin add card / Input admin add fingerprint
-
Read the 1st user card / Input the 1st fingerprint twice
-
Read admin add card / Input admin add fingerprint
-
Read the 2nd user card / Input the 2nd fingerprint twice
Note: The admin add card / admin add fingerprint is used to add card /
fingerprint users
continuously and quickly. When you read the admin add card / input the admin
add fingerprint
at the first time, you will hear short “BEEP” sounds twice and the indicator
light turns orange, it
means you have entered into add user programming, when you read the admin add
card / input
the admin add fingerprint at the second time, you will hear long “BEEP” sound
once and the indicator light turns red, it means you have exited the add user
programming.
Delete Users
-
Read admin delete card / Input admin delete fingerprint
-
Read the 1st user card / Input the 1st
-
fingerprint twice
-
Read the 2nd user card/ input the 2nd fingerprint once
-
Read admin delete card
Note: The admin delete card / admin delete fingerprint is used to delete
card / fingerprint users
continuously and quickly. When you read the admin delete card / admin delete
fingerprint at the
first time, you will hear short “BEEP” sounds twice and the indicator light
turns orange, it means
you have entered into delete user programming, when you read the admin delete
card / admin
delete fingerprint at the second time, you will hear long “BEEP” sound once,
the indicator light
turns red, it means you have exited the delete user programming.
Other Operation
Remove Alarm
-
Read valid card
-
Input valid fingerprint
-
Press admin code#
Note: When the alarm is activated, users can remove the alarm by reading a valid card or inputting valid fingerprint or pressing valid admin code.
Reset to Factory Default
Users can reset to the factory default when the admin code is forgotten, or
the default settings
have been modified disorderedly, operations as below:
Power off, press and hold the exit button continuously, power on, release the
exit button until hearing beep sound twice, the admin code has been reset to
999999, factory default settings are successful.
Note: Registered user data won’t be deleted when reset to factory default.