COMMISSIONING GUIDELINES
Anker SOLIX MI80 Microinverter
(800W BLE)
PAP 22
Raccolta Carta
51005004056 V01
If you received Anker SOLIX MI80 Microinverter (800W BLE) (A5143), please
follow the steps below.
The pictures are for reference only. Your item may look slightly different
from the picture. Please refer to the actual item received.
Maximum output power limited to 600W as default.
Commissioning
-
Connect the solar panel and the microinverter with the solar panel extension cables.
Note:
1. Ensure that two solar panels have been installed before this step.
2. This step must be done while there is enough sunlight for the solar panel to provide power to the microinverter. -
Turn on Bluetooth on your phone.
-
Download the app, and follow the in-app instructions to finish the microinverter configuration and Schuko cable connection, Then you can connect the microinverter to your home grid via the Schuko cable.
Auto Mode:
Scan the QR code or search “Anker” on the App Store, Google Play, or other official app stores to download the app.
Sign up/log in to your Anker account.
Tap Add Devices/+ > MI80 Microinverter (BLE).
Select your home’s Wi-Fi, enter the password, then click the Next button. You will be directed to the Scanning page. Wait a moment.
If you are redirected to the No Devices Found page, press the Retry Now button, then repeat step 4.
If you are redirected to the Added Successfully page, the configuration is complete. You can also revise the device name on this page.https://rainbowbridge.anker.com/qrscan?key=anker
Manual Mode:
Scan the QR code or search “Anker” on the App Store, Google Play, or other official app stores to download the app.
Sign up/log in to your Anker account.
Tap Add Devices/+ > Balcony Solar Power System > MI80 Microinverter (BLE).
Follow the in-app instructions and tap The device has been reset.
Select your home’s Wi-Fi, enter the password, then click the Next button. You will be directed to the Scanning page. Wait a moment.
If you are redirected to the No Devices Found page, press the Retry Now button, then repeat step 4.
If you are redirected to the Added Successfully page, the configuration is complete. You can also revise the device name on this page.https://rainbowbridge.anker.com/qrscan?key=anker -
For your privacy and security, the microinverter will automatically turn off Bluetooth after commissioning is finished. You can turn on the microinverter’s Bluetooth again by disconnecting and reconnecting the DC wires. Follow the above steps to complete commissioning within 15 minutes.
LED Guide
When sufficient DC voltage from the module is applied, the microinverter will be powered, and the LED will start flashing.
LED Indicator | Description | How To |
---|---|---|
Ten Short Green Flashes | DC power is first applied to the microinverter, the | |
startup is successful. | Follow the instructions to start the configuration. | |
Flashing Green Every 5 Seconds | Producing power. | The system is working. |
Flashing Red Every 5 Seconds | The microinverter is in protection status or | |
disconnected from the grid. | Check if the AC input of the micro inverter is |
normal. If so, make sure that the microinverter is connected to the network
and contact Anker Support.
Steady Red| Ground Fault Detector Interrupter (GFDI) error in the PV system is
detected.| Check if the DC input of the microinverter is mistakenly connected
to the ground or contact Anker Support.
Specifications
| Model| A5143
---|---|---
Input Data (DC)| Recommended PV Module Power (STC) Range| 300Wp-730Wp+
Peak Power Tracking Voltage| 28V-45V
Operating Voltage Range| 16V-60V
Maximum Input Voltage| 60V
Maximum Input Current| 20A × 2
Isc PV| 25A × 2
Output Data (AC)| Maximum Continuous Output Power| 799VA
Nominal Output Voltage / Range (1)| 230V/184-253V
Nominal Output Current| 3.5A
Nominal Output Frequency / Range (1)| 50Hz/47.5Hz-51.5Hz
Power Factor| 0.99
Efficiency| Peak Efficiency| 97.30%
Nominal MPPT Efficiency| 99.50%
Night Power Consumption| 20mW
Mechanical Data| Operating Ambient Temperature Range (2)| -40 °C to 65 °C
Storage Temperature Range| -40 °C to 85 °C
Dimensions (W × H × D)| 263mm × 218mm × 36.5mm
Weight| 2.8kg
DC Connector Type| Stäubli MC4 PV-ADBP4-S2&ADSP4-S2
Cooling| Natural Convection – No Fans
Enclosure Environmental Rating| IP67
AC Extension Cable (Optional)| Wire Size| 1.5mm²
Cable Length| 5M (Default)
Plug Type| Schuko
Features| Communication (Inverter To ECU)| Built-in Wi-Fi and Bluetooth
Isolation Design| High Frequency Transformers, Galvanically Isolated
Energy Management| Energy Management Analysis (EMA) system
Compliances| Safety and Grid Compliances| EN 62109-1/-2;
EN 50549-1;
DIN V VDE V 0126-1-1; VFR;UTE C15-712-1;
CEI 0-21;
UNE 217002;
VDE-AR-N 4105
- Nominal voltage / frequency range can be extended beyond nominal if required by the utility.
- The microinverter may enter Power Degrade mode if there is poor ventilation and heat dissipation in the installation environment.
Notice
CE RED Declaration of Conformity (For Microinverter)
This product complies with the radio interference requirements of the European
Community. Hereby, Anker Innovations Limited declares that the radio equipment
is in compliance with Directive 2014/53/EU. The full text of the EU
Declaration of Conformity is
available at the following website: https://www.anker.com
Bluetooth maximum output power: 18.18 dBm (For EU)
Bluetooth frequency band: 2.4G band (2.402GHz – 2.480GHz)
Wi-Fi maximum output power: 19.86 dBm (For EU)
Wi-Fi frequency band: 2.4G band (2.412GHz – 2.472GHz)
This symbol indicates that this product shall not be treated as household
waste. Instead, it shall be handed over to the applicable collection point for
the recycling of electrical and electronic equipment.
Warranty and Customer Service