Hussmann MDN Medium Temperature Self Contained Open Vertical Merchandiser Instruction Manual
- June 17, 2024
- HUSSmAnn
Table of Contents
- Hussmann MDN Medium Temperature Self Contained Open Vertical Merchandiser
- Product Information
- Product Usage Instructions
- FAQs
- BEFORE YOU BEGIN
- INSTALLATION
- ELECTRICAL / REFRIGERATION
- STEPS TO RECOVER REFRIGERANT
- MAINTENANCE
- TROUBLESHOOTING
- SERVICE
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Hussmann MDN Medium Temperature Self Contained Open Vertical Merchandiser
Product Information
Specifications
- Model: MDN (120V)
- Type: Medium Temperature Self Contained Open Vertical Merchandiser
- Refrigerant: R-290
- Power: 120V
Product Usage Instructions
Before You Begin
Read these instructions completely and carefully. Personal Protection Equipment (PPE) is required whenever installing or servicing this equipment. Always wear safety glasses, gloves, protective boots or shoes, long pants, and a long-sleeve shirt as required when installing or servicing this equipment.
Important Warnings
- If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal injury, or death.
- Installation and service must be performed by a qualified installer or service agency.
- This unit is designed only for use with R-290 gas as the designated refrigerant. The refrigerant loop is sealed, and only a qualified technician should attempt to service it.
Operation Instructions
Merchandiser must operate for 24 hours before loading product. Regularly check merchandiser temperatures. Do not break the cold chain. Keep products in freezer before loading into merchandiser.
General Safety Precautions
The safety of our customers and employees is paramount. Please comply with the precautions described in this manual to protect yourself and others from possible harm. Follow OSHA standards for safety.
FAQs
- Q: What type of refrigerant does this unit use?
- A: This unit is designed to use R-290 refrigerant.
- Q: Can I service the refrigerant loop myself?
- A: No, only a qualified technician should attempt to service the sealed refrigerant loop.
MDN (120V)
Medium Temperature Self Contained Open Vertical Merchandiser
WARNINGS:
If the information in these instructions are not followed exactly, a fire or
explosion may result, causing property damage, personal injury or death.
with R-290 Refrigerant
Installation and service must be performed by a qualified installer or service agency.
READ THE ENTIRE MANUAL BEFORE INSTALLING OR USING THIS EQUIPMENT.
The unit uses R-290 gas as the refrigerant. R-290 is flammable and heavier than air. It collects first in low areas but can be circulated by the fans. If propane gas is present or even suspected, do not allow untrained personnel to attempt to find the cause. The propane gas used in the unit has no odor. The lack of smell does not indicate a lack of escaped gas. If a leak is detected, immediately evacuate all persons from the store, and contact the local fire department to advise them that a propane leak has occurred. Do not let any persons back into the store until the qualified service technician has arrived and that technician advises that it is safe to return to the store. No open flames, cigarettes or other possible sources of ignition should be used inside or in the vicinity of the units.
Installation & Operation Manual
FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION, DEATH, INJURY AND PROPERTY DAMAGE.
P/N 9FQ6P11007900_B
IMPORTANT Keep in store for future reference!
MANUAL I/O- MDN R-290 120V
June 2023 Spanish P/N 9FQ6P11008200
P/N 9FQ6P11007900_B
iii
BEFORE YOU BEGIN
Read these instructions completely and carefully.
PERSONAL PROTECTION EQUIPMENT (PPE)
Personal Protection Equipment (PPE) is required whenever installing or
servicing this equipment. Always wear safety glasses, gloves, protective boots
or shoes, long pants, and a long-sleeve shirt as required when installing or
servicing this equipment.
1. If the information in these instructions are not followed exactly, a fire
or explosion may result, causing property damage, personal injury or death.
2. Installation and service must be performed by a qualified installer or
service agency. 3. This unit is designed only for use with R-290 gas as the
designated refrigerant.
THE REFRIGERANT LOOP IS SEALED. ONLY A QUALIFIED TECHNICIAN SHOULD ATTEMPT TO
SERVICE!
· Propane is flammable and heavier than air. · It collects first in the low
areas but can be circulated by the fans. · If R-290 is present or even
suspected, do not allow untrained personnel to attempt to find the cause. ·
The propane gas used in the unit has no odor. · The lack of smell does not
indicate a lack of escaped gas. · If a leak is detected, immediately evacuate
all persons from the store, and contact the local fire department to advise
them that a
pro pane leak has occurred. · Do not let any persons back into the store until
the qualified service technician has arrived and that technician advises that
it is
safe to return to the store. · A hand-held propane leak detector (“sniffer”)
shall be used before any repair and/or maintenance. · No open flames,
cigarettes or other possible sources of ignition should be used inside the
building where the units are located
until the qualified service technician and/or local fire department determines
that all propane has been cleared from the area and from the refrigeration
systems. · Component parts are designed for propane and non-incendive and non-
sparking. Component parts shall only be replaced with identical repair parts.
FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION, DEATH, INJURY
AND PROPERTY DAMAGE.
P/N 9FQ6P11007900_B
v
ATTENTION
MMeerrcchhaannddiisseerrmmuusstt ooppeerrate for 24 hours
bbeefoforreeloloaaddininggpprroodduucctt!!
RReegguulalarrlylycchheecckk mmeerrcchhaannddiisseerr
tteemmppeerraattuurreess.. DDoonnoottbbrreeaakkththeeccooldldcchhaainin.
.KKeeepppprordoudcutcstsin in cfroeoelzeer
rbbeefoforereloloaadidnignginitnotommerecrhcahnadnidsiesre. r.
TheTsehemsercmhearncdhiasnedrsisaerres daeresigdneesdignfoerdonly for opnrley-
cphreil-lefrdozperondpurcotds.ucts.
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
IMPORTANT KEEP IN STORE FOR FUTURE REFERENCE
Quality that sets industry standards!
12999 St. Charles Rock Road · Bridgeton, MO 63044-2483 U.S. & Canada
1-800-922-1919 · Mexico
1-800-890-2900
www.hussmann.com
© 2023 Hussmann Corporation
P/N 9FQ6P11007900_B
The safety of our customers and employees is paramount . The precautions and
procedures described in this manual are intended as general methods for safe
use of this equipment . Please be sure to comply with the precautions
described in this manual to protect you and others from possible harm, and
follow OSHA standards for safety .
The definitions at right are used to clarify the magnitude and urgency of harm
and damage, considering problems arising from misuse . Relative to their
potential danger, the definitions are divided into four parts according to
ANSI Z535 Series .
vii
ANSI Z535 .5 DEFINITIONS
! · DANGER Indicate[s] a hazardous situation which, if not avoided, will
result in death or serious injury .
· WARNING Indicate[s] a
! hazardous situation which, if not
avoided, could result in death or serious injury .
! · CAUTION Indicate[s] a hazardous situation which, if not avoided, could
result in minor or moderate injury .
FOR CALIFORNIA INSTALLATIONS ONLY:
WARNING:
· NOTICE Not related to personal injury Indicates[s] situations, which if not avoided, could result in damage to equipment .
Cancer and Reproductive Harm
www.P65Warning.ca.gov
August 31, 2018
3069575
This warning does not mean that Hussmann products will cause cancer or reproductive harm, or is in violation of any product-safety standards or requirements. As clarified by the California State government, Proposition 65 can be considered more of a `right to know’ law than a pure product safety law. When used as designed, Hussmann believes that our products are not harmful. We provide the Proposition 65 warning to stay in compliance with California State law. It is your responsibility to provide accurate Proposition 65 warning labels to your customers when necessary. For more information on Proposition 65, please visit the California State government website.
REVISION HISTORY
REVISION B Updated California Warning and ANSI/NSF References
ORIGINAL ISSUE — NOVEMBER 2021 HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483
U.S.A.
Excessive ambient conditions may cause condensation and therefore sweating of
doors. Facility operators should monitor doors and floor conditions to ensure
safety of persons.
All installation and operating instructions concerning the handling, moving,
and use of these merchandisers must be carefully followed to avoid either
damaging the refrigerant tubing, or increasing the risk of a leak.
Case ventilation openings must be clear of any obstructions. Do not damage the
refrigerant circuit.
Always disconnect the electrical power at the main disconnect when servicing
or replacing any electrical component. This includes, but is not limited to,
such items as fans, heaters, thermostats and lights.
Do not use mechanical devices or other means to accelerate the defrosting
process.
Do not use electrical appliances inside the food storage compartments of the
case.
Open Vertical Merchandisers
P/N 9FQ6P11007900_B
1-1
INSTALLATION
UL LISTING
These merchandisers are manufactured to meet ANSI/ UL 471 standard
requirements for safety . Proper installation is required to maintain the
listing .
FEDERAL / STATE REGULATION
Apparent Loss or Damage
If there is an obvious loss or damage, it must be noted on the freight bill or
express receipt and signed by the carrier’s agent; otherwise, carrier may
refuse claim .
These merchandisers at the time they are manufactured, meet all federal and
state/ provincial regulations . Proper installation is required to ensure
these standards are maintained . Near the serial plate, each merchandiser
carries a label identifying the environment for which the merchandiser was
designed for use . This model is Type II as described below .
NSF/ANSI 7 Type II Display Refrigerator / Freezer Intended for 80°F / 55%RH
Ambient Application
NSF/ANSI 7 Display Refrigerator Intended for Bulk Produce
HUSSMANN PRODUCT CONTROL
The serial number and shipping date of all equipment is recorded in Hussmann’s
files for warranty and replacement part purposes . All correspondence
pertaining to warranty or parts ordering must include the serial number of
each piece of equipment involved . This is to ensure the customer is provided
with the correct parts .
SHIPPING DAMAGE
All equipment should be thoroughly examined for shipping damage before and
during unloading . This equipment has been carefully inspected at our factory
.
Concealed Loss or Damage
When loss or damage is not apparent until after equipment is uncrated, retain
all packing materials and submit a written response to the carrier for
inspection within 15 days .
Recommended operating ambient temperature is between 60°F (16°C) to 80°F
(27°C). Maximum relative
humidity is 55%.
LOCATION
These merchandisers are designed for displaying products in air conditioned
stores where temperature is maintained at or below the NSF/ANSI 7 specified
level and relative humidity is maintained at or below 55% .
Placing refrigerated merchandisers in direct sunlight, near hot tables or near
other heat sources could impair their efficiency . Like other merchandisers,
these merchandisers are sensitive to air disturbances . Air currents passing
around merchandisers will seriously impair their operation . Do NOT allow air
conditioning, electric fans, open doors or windows, etc . to create air
currents around the merchandiser .
Any claim for loss or damage must be made to the carrier . The carrier will
provide any necessary inspection reports and/or claim forms .
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Do NOT stand or walk on top of merchandiser. Do not store items or
flammable materials atop the unit.
Open Vertical Merchandisers
1-2
INSTALLATION
LOCATION (Continued)
Product should always be maintained at proper temperature . This means that
from the time the product is received, through storage, preparation and
display, the temperature of the product must be controlled to maximize the
life of the product .
BE SURE TO POSITION SELF CONTAINED MERCHANDISERS PROPERLY.
SELF CONTAINED models have vented base panels to allow air circulation through
the condensing unit .
Allow for a minimum of 2 inches of clearance from walls, merchandisers, and
any other large objects near the merchandiser’s vented base panels. A minimum
space of 2 inches should be left above the case. Blocking or restricting air
flow will adversely affect performance and may damage the refrigeration
system.
If the merchandiser is used or stored in a hot spring or coastal area, it may
be damaged (due to sulfur or salt) . If the intention is to install the
merchandiser in any of the above areas or locations, contact the supplier or
dealer where you purchased the merchandiser . Do not lay the case sideways to
move the case . This may cause damage . Case should be installed on a flat,
level floor .
After installation, fix the case in place with the leveling legs (case option)
to make sure that it does not move. Or if the case has casters, lock the
casters.
Air inlet
Do not block this inlet or the merchandiser will not cool properly
Air Exhaust
Ground wire
(Optional)
Hanging Wall
2-inch gap required
(51 mm)
Wall
! WARNING
Do not store items or flammable materials atop the unit.
P/N 9FQ6P11007900_B
Leveling Legs or Casters
Floor
2-inch gap required
(51 mm)
U.S. & Canada 1-800-922-1919 · Mexico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
Part names
Model MDN 120V shown Lamp switch
Tag molding
Deck pan Hussmann logo
1-3
Bracket
Shelf
The slots that hold the left and right shelf brackets are located at 0.59 inch
intervals. The shelf position can thus be adjusted to match the size of the
product stored.
Overflow drain pan
Front panel
Electrical controls box
Main Switch
Controller
KDEPLUS BUTTONS
The KDEPlus keyboard has 4 keys, as shown in the illustration:
UP 1 DOWN 2
3 STANDBY or ESC 4 SET
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
1-4
INSTALLATION
Part names
Model MDN 120V shown Night Curtain (Optional)
LED lamp
Discharge air outlet
Do not block this outlet with product, or the merchandiser will not cool
properly.
Return air inlet
Do not block this inlet with product, or the merchandiser will not cool
properly.
Night Curtain
hook (Optional)
Handrail
Condenser fan Air inlet
Do not block this inlet or the merchandiser will not cool properly
Caster Condensing unit Overflow drain pan
Additional parts
Honeycomb
The honeycomb adjusts the air flow.
Evaporator fan Single-phase 120V power cord NEMA L5-30P
Air Outlet
P/N 9FQ6P11007900_B
U.S. & Canada 1-800-922-1919 · Mexico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
1-5
MODEL DESCRIPTION
The MDN models are open, vertical, medium temperature display merchandisers .
They are self contained merchandisers with their own condensing unit . Each
self contained model has a condensing unit that is factory installed beneath
the display area of the case . The unit is ready for operation when electrical
service is connected . See Section 2 for electrical information before
starting the case .
UNLOADING
Unloading from Trailer: Lever Bar (also known as a Mule, Johnson Bar, J-bar,
Lever Dolly, or Pry Lever) Move the merchandiser as close as possible to its
permanent location and remove all packaging . Check for damage before
discarding packaging . Remove all separately packed accessories such as kits
and shelves . Improper handling may cause damage to the merchandiser when
unloading . To avoid damage:
1 . Do not drag the merchandiser out of the trailer . Use a Johnson bar (mule)
.
2 . Use a forklift or dolly to remove the merchandiser from the trailer .
EXTERIOR LOADING
Do NOT walk on top of merchandisers or damage to the merchandisers and serious
personal injury could occur . Merchandisers are not structurally designed to
support excessive external loading such as the weight of a person . Do not
place heavy objects or flammable materials on the merchandiser .
SHIPPING SKID
Each merchandiser is shipped on a skid to protect the merchandiser’s base, and
to make positioning the case easier . Remove the top of the crate, and detach
walls from each other . Lift crate from the skid . Unscrew the case from the
skid . The fixture can now be lifted off the crate skid . Lift only at base of
skid! Remove any attached braces and/or skids .
DO NOT TILT MERCHANDISER ON ITS SIDE OR END WHEN REMOVING SKID .
The case is equipped with casters for ease of installation and transportation
inside store . Check floor where cases are to be set to see if it is a level
area . Determine the highest part of the floor .
SERIAL PLATE LOCATION The serial plate is located at the interior top left end
. It contains all pertinent information such as model, serial number, amperage
rating, refrigerant type and charge .
Serial Plate
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Do NOT remove shipping crate until the merchandiser is positioned for
installation.
THERMOMETER
The cabinet has a “pencil” type thermometer and reads from -40º F to 120º F /
-40º F to 50º F on 2º increments . The thermometer is located in the packout
kit inside of the merchandiser .It should be placed and left inside the bottom
front interior compartment during normal operation of the merchandiser .
Open Vertical Merchandisers
1-6
INSTALLATION
Hussmann Self-Contained Refrigeration Equipment Start Up Check List
Please note that failure to follow this start-up document may void your
factory warranty
Step
Startup Activity
1
Locate, read and maintain install/operation manual in a safe place for future reference .
Check
2 Examine unit . Confirm there is NO damage or concealed damage .
3 Level the unit, side to side and front to rear .
4 Remove all shipping brackets/compressor straps/bolts etc . as required
5
Unit must be run on a dedicated electrical circuit without the use of an extension cord .
6
Ensure that the proper electrical requirements for the equipment are supplied .
7 Verify field electrical connections are tight .
8
Verify all electrical wiring is secured and clear of any sharp edges or hot lines .
9 Verify the condensate drain line is properly trapped and pitched .
10 Verify all required clearances on the sides and back of unit .
11
Verify there are no air disturbances external to the unit . Heat and air registers, fans, and doors etc .
Advise owner/operator that merchandiser must operate at temperature for 24 hrs
prior to loading with product.
Form HSCW01 Rev. 30MAY12 P/N 0525209_B
LEGAL DISCLAIMER:
Hussmann shall not be liable for any repair or replacements made without the
written consent of Hussmann, or when the product is installed or operated in a
manner contrary to the printed instructions covering installation and service
which accompanied such product.
P/N 9FQ6P11007900_B
U.S. & Canada 1-800-922-1919 · Mexico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
2-1
ELECTRICAL / REFRIGERATION
MERCHANDISER ELECTRICAL DATA Refer to merchandiser serial plate for electrical
information .
FIELD WIRING Field wiring must be sized for component amperes stamped on the
serial plate . Actual ampere draw may be less than specified .
ALWAYS CHECK THE SERIAL PLATE FOR COMPONENT AMPERES
ELECTRICAL CONNECTIONS
· Plug into an outlet designed for the plug . · Do not overload the circuit ·
Do not use long or thin extension cords .
Never use adapters . · If in doubt, call an electrician .
Ensure ground pin is attached .
For any questions, contact the supplier or dealer where you purchased the
product or licensed service provider .
! WARNING
Risk of Electric Shock. If cord or plug becomes damaged, replace only with a
cord and plug of the same type.
All wiring must be in compliance with NEC and local codes . Self contained
models are electrical cord connected at the electrical box . Ensure ground pin
is attached . For any questions, contact the supplier or dealer where you
purchased the product or licensed service provider .
This unit uses a powercord with NEMA (L5-30P) plug .
! WARNING
Merchandiser must be grounded. Do not remove the power supply cord ground.
POWER SWITCH
The main ON/OFF switch is located on the front control on the bottom,
righthand-side of merchandiser .
The powercord is rated for 30A/120V .
ELECTRICAL OUTLET
Before the merchandiser is connected to any wall circuit, use a voltmeter to
check that the outlet is at 100% of the rated voltage . The wall circuit must
be dedicated for the merchandiser . Failure to do so voids the warranty . Do
not use an extension cord. Never plug in more than one merchandiser per
electrical circuit .
· Always use a dedicated circuit with the amperage stated on the unit .
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Remove front grille. Power switch is located on the righthand side of the
merchandiser, behind front grille.
Front Grille
Power Switch
Open Vertical Merchandisers
2-2
ELECTRICAL / REFRIGERATION
REFRIGERATION
WATER OUTLET AND WATER SEAL
Each self-contained model is equipped with its own condensing unit and control panel located beneath the display area . The correct type of refrigerant will be stamped on each merchandiser’s serial plate . The merchandiser refrigeration piping is leak tested . The unit is charged with refrigerant, and shipped from the factory with all service valves open .
The condensate water outlet is located at the front of the liner bottom under
deck pan . The outlet has a factory installed, external water seal .
For self contained models, this water seal drains into the condensate
evaporator pan located beneath the merchandiser .
! WARNING
Refrigeration lines are under pressure. Refrigerant must be recovered before
attempting any connection or repair.
NOTE: All lower base panels must be in place when the refrigerator is
operating . If not, airflow from the condenser will be directed over the
evaporator pan and defrost water in the pan may overflow .
! WARNING
Product will be degraded and may spoil if allowed to sit in a non-refrigerated
area.
…ATTENTION INSTALLER
It is the contractor’s responsibility to install merchandiser(s) in accordance
with
all local building and health codes.
! WARNING
— LOCK OUT / TAG OUT — To avoid serious injury or death from electrical shock,
always disconnect the electrical power at the main disconnect when servicing
or replacing any electrical component. This includes, but is not limited to,
such items as doors, lights, fans, heaters, and thermostats.
P/N 9FQ6P11007900_B
U.S. & Canada 1-800-922-1919 · Mexico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
2-3
CONTROLS AND ADJUSTMENTS
The controller controls refrigeration temperature . The controller is factory
installed in the control panel mounted on the merchandiser’s fascia .
Discharge air temperatures should be measured at the center of the honeycomb .
Defrosts are time initiated and temperature terminated for these models . The
defrost setting is set in the factory . The product application is factory set
for Med . Temp . – NSF7 as shown below .
Model MDN4775B1A/S1A MDN3575B1A/S1A
Product Application
Med Temp – DOE Med Temp – NSF 7 Type 1
Med Temp – DOE Med Temp – NSF 7 Type 1
Discharge Air Temperature ( Avg Ref mode )
25 ° F – 27 °F ( -4 °C to -3 °C )
25 ° F – 27 °F ( -4 °C to -3 °C )
Controller Set Point ( ° F )
23 ° F ( – 5 ° C ) 19 ° F ( – 7 ° C ) 28 ° F ( – 2 ° C ) 25 ° F ( – 4 ° C )
Note: The cases are shipped out from factory with controller settings to comply with NSF 7 requirements.
Defrost Frequency
( per day )
Type of Defrost Temp. Termination Failsafe time ( min )
6
Off Time
45 ° F ( 7 ° C )
50
Honeycomb Discharge air temp MDN3575 B1A @ NSF Type 1 ( ° F )
60 50 40 30 20 10
0
1 45 89 133 177 221 265 309 353 397 441 485 529 573 617 661 705 749 793 837 881 925 969 1013 1057 1101 1145 1189 1233 1277 1321 1365 1409
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
2-4
ELECTRICAL / REFRIGERATION
CONTROLLER OPERATION
The electronic controller is located in the cassette compartment . The controller comes factory set, and is ready for use . The front grille must be removed in order to access this control . When removing the grille for this operation or for condenser cleaning, care must be taken not to damage the display interface cable . It may be unplugged during this task .
This cabinet temperature may reflect the refrigeration cycle of the Set-Point
and its’ Differential . The most accurate temperature on a cabinets operation
is to verify the product temperature .
Main Features:
1 . Plug the merchandiser plug into its receptacle . · Panel-mounted
a . The controller display will illuminate . b . The interior light will
illuminate .
2 . After the control preprogrammed time delay of up to 6 minutes, the
compressor and evaporator fan(s) will start if the control is calling for
cooling .
· Energy saving algorithms and optimized defrost control
· 8 preloaded applications · Defrost at single / double evaporator · Frame
Heater · Local network auto-configuration
3 . The control will cycle the compressor but may also cycle evaporator fan(s) on and off determined by the Set-Point and Differential temperatures .
· Direct load connection (up to 2 HP) · Supply voltage control LVD · Presence of an open collector output
a . The Set-Point is the adjustable preprogrammed temperature .
b . The Differential is the non-adjustable pre programmed temperature .
c . The Control is designed to read and display a cabinet temperature not a
product temperature .
P/N 9FQ6P11007900_B
U.S. & Canada 1-800-922-1919 · Mexico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
2-5
CONNECTIONS
TERMINALS
1
2
3
4
5
6
OUT2 (1HP)
7
8
9 OUT3 (8A)
10 11
OUT1 (2HP)
12 13 14
OUT4 (8A)
A 15 16 17
GND D 12V
{
KEYB
RS485 OPTIONAL
34 35 36 37 38 39
33
12V
32
OC
31
D
30 29
GND LINK2
D
{
28
GND
27
26
25
24
23
22
21
20
19
18
ELIWELL
- N.B.: analogue inputs PB1…PB5 can also be configured as Digital Inputs DI.
TERMINALS
1-2 NEUTRAL. These are power supply terminals.
15-16-17
Connection to KDEPlus or KDWPlus external keyboard or ECPlus echo module.
3 LINE. These are power supply terminals.
19-18 PB1 probe connection.
4 OUT2 Shared Terminal
21-20 PB2 probe connection.
5 N.O. OUT2
23-22 PB3 probe connection.
6 N.C. OUT2
23-24 PB4 probe connection.
7 OUT3 Shared Terminal
23-25 PB5 probe connection.
8 N.C. OUT3
27-26 Digital input (DI).
9 N.O. OUT3
28-29 LINK2. Connection 1 – local area network.
10 OUT1 Shared Terminal
30-31 LINK2. Connection 2 – local area network.
11 N.O. OUT1
32-33 Open Collector Output (OC).
12 Not Used
A TTL Unicard/DMI/Multi Function Key connection
13 OUT4 Shared Terminal
34-35-36 RS485. Connection 1 – Supervision Gateway.
14 N.O. OUT4
37-38-39 RS485. Connection 2 – Supervision Gateway.
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
2-6
ELECTRICAL / REFRIGERATION
KDEPLUS BUTTONS
The KDEPlus keyboard has 4 keys, as shown in the illustration:
UP 1 DOWN 2
3 STANDBY or ESC 4 SET
Each key has a different function depending on whether it is: · Pressed and released · Pressed for at least 5 seconds · Pressed and held at start-up · Pressed in combination with another key.
KEYS The following table summarizes the function of each key:
No
Key
Pressed and released
Action Press for at least 5 secs
1
· Scrolls through menu items · Decreases values
Activates the Manual Defrost function (from outside menus).
Start-up —
2
· Scrolls through menu items · Decreases values
Function can be configured by the user (from outside menus). (see parameter H32)
—
3
· Returns to the previous menu level
· Confirms parameter value
Activates the Stand-by function (from outside menus).
—
· Displays any alarms
4
set (if active) · Opens Machine Status menu
Opens the Programming Menu (User and Installer parameters)
· Confirms commands
When pressed during start-up it enables the user to select the application to be loaded.
Product will be degraded and may spoil if allowed to sit in a non-refrigerated area.
Do NOT allow cleaning agent or cloth to contact food product.
P/N 9FQ6P11007900_B
U.S. & Canada 1-800-922-1919 · Mexico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
2-7
SETPOINT: SETTING AND EDIT LOCK
To display the Setpoint value, press the set key to enter the “Machine Status”
menu, then press the set key again when the “SEt” label is displayed. The
Setpoint value appears on the display. To change the Setpoint value, press the
and keys within 15 seconds. Press set to confirm the modification.
set
set
set
set
set
It is possible to disable the keypad on this device.
TWhiethktehyseeptkaedycpaandbloeclkoecdke, ydobuycparnosgtirlal macmceinsgs
the the
“LOC” parameter appropriately. “Machine Status” menu by pressing
set
to display the Setpoint, but you cannot edit
it. To disable the keypad lock, repeat the locking procedure.
set
set
set
DISPLAY PROBES VALUE
To display the value read by probes connected to the device, press the set key
and enter the “Machine Status” menu, then press the key again when one of the
probe-related labels “Pb1…Pb5” press the set key agasient. The value measured
by the associated probe will appear on the display.
NOTE: The displayed value is read-only and cannot be modified.
KDEPLUS BUTTONS
The KDEPlus keyboard has 4 keys, as shown in the illustration:
UP 1 DOWN 2
set set
3 STANDBY or ESC 4 SET
KEY-ACTIVATED FUNCTIONS
All models have the UP key set to enable the “Manual Defrost” function. The
DOWN and ESC keys can also be set to activate any other function required by
the user. The parameters for configuring the two keys are:
· H11 = DOWN key configuration · H33 = ESC key configuration
The values that can be set apply to both keys and the functions that can be
activated are:
H32/H33 value
0 1 2 3 4 5 6
7 set
8
Function to enable
disabled defrost reduced set Light Energy saving
AUX Stand-by Deep cooling cycle Start/end defrost
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
2-8
ELECTRICAL / REFRIGERATION
DEFROST SENSOR LOCATION
The defrost sensor (orange color) is installed on the 3rd turn, on the coil . Make sure the sensor is touching the copper metal surface . The sensor is held in place with a tie wrap .
A
NOTE: It is critical for merchandiser operating performance to have the
sensors in this location. If for any reason, the sensors are removed, they
need to be placed in the original location.
DISCHARGE AIR SENSOR LOCATION
The discharge air sensor (green color) is installed above the coil on the
burring mark . Avoid touching the metal surface with the sensor tip . Ensure
there is a turn of wiring .
A
DETAIL A
P/N 9FQ6P11007900_B
DETAIL A
U.S. & Canada 1-800-922-1919 · Mexico
01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
2-9
SHELVES
Shelves should be loaded so that the product does not extend over the front
edge of the shelf . Product loaded over the edge will interfere with air
circulation in the cabinet .
· Display items in such a way that will not protrude from the shelf / deck pan
.
· Display the items uniformly on shelf / deck pan .
Allow merchandiser 24 hours to operate before loading product. Proper rotation of product during stocking is necessary to prevent product loss . Always bring the oldest product to the front and set the newest to the back . Air discharge and return flues must remain open and free of obstruction at all times to provide proper refrigeration and air curtain performance . Do not allow product, packages, signs, etc . to block the air inlet and air outlet .
·
Do not place items more than 155 lbs on deck pan and shelf .
Do not use unapproved shelving, baskets, display
racks, or any accessory that could hamper air
· After removing the items, adjust the height and angle of the shelf .
curtain performance . Contact your Hussmann representative for more information .
· Adjust height and angle according to the product .
· The shelf height can be adjusted at 0 .59 inch intervals .
DRAIN WATER
· Change the angle of the shelf with the hook as the fulcrum .
STOCKING
Product should NOT be placed inside the merchandisers until merchandisers are
at proper operating temperature .
If the evaporation mechanism is attached, drainage work is unnecessary if the
outside air temperature is 80°F, the humidity is 55% RH, and the ambient wind
speed is less than 47 .2 FPM .
During the summer and on high-humidity days, check the overflow drain pan at
the bottom of the case, and throw out any excess water (See location
illustration on Page 1-3) .
RE-START
A clearance of 2.5 inches is needed near the ends in order to maintain air flow and proper cooling performance.
Leave the product in the case for at least 5 minutes before re-starting the
case .
If the merchandiser is re-started immediately after stopping, the overload
protection unit or a breaker for wiring may trip, or an excessive load may be
applied to the compressor, which will result in failure .
Do not block the discharge air outlet and return air inlet with products.
For energy savings: Please turn off the lights at night and at the time of closing the store . When night curtains are provided, pull them down during off hours to enhance product quality .
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
2-10
ELECTRICAL / REFRIGERATION
Before Beginning Any Service or Repair:
Use a hand-held propane leak detector (“sniffer”) to ensure no propane is
present in the immediate area, the inside of the display case and the inside
of the refrigeration system . R-290 is an odorless refrigerant . Keep the area
clear of all customers and non-essential or unauthorized personnel .
Verify that all repair parts are identical models to the ones they are
replacing . Do not substitute parts such as motors, switches, relays, heaters,
compressors, power supplies or solenoids . Failure to do so can result in an
explosion, death, injury and property damage . Parts used on hydrocarbon cases
must meet specific UL certification for non-incendive or non-sparking
components . Use only Hussmann approved parts approved through the Hussmann
Performance Parts Website . https://parts .hussmann .com/
Only Hussmann or factory trained technicians should service or repair this
R-290 (propane) equipment.
Failure to follow instructions can result in an explosion, death, injury and
property damage.
Brazing must not begin before all propane has been cleared from the immediate area — the inside of the displays case and the inside of the refrigeration system .
If a leak is detected, follow store safety
· The propane gas used in the unit has no odor .
procedures . It is the store’s responsibility to have The lack of smell does not indicate a lack of
a written safety procedure in place . The safety escaped gas .
procedure must comply with all applicable codes · A hand-held propane leak detector
such as local fire department’s codes .
(“sniffer”) should be used before any repair and/
or maintenance is attempted . All repair parts
At minimum, the following actions are required: must be identical models to the ones they are
· Immediately evacuate all persons from the replacing .
store, and contact the local fire department to · No open flames, cigarettes or other possible
advise them that a propane leak has occurred . sources of ignition should be used inside the
· Call Hussmann and/or a qualified service building where the units are located until the
agent and inform them that a propane sensor has qualified service technician and/or local fire
detected the presence of propane .
department determines that all propane has been
· Do not let any persons back into the store cleared from the area and from the refrigeration
until the qualified service technician has arrived systems .
and that technician advises that it is safe to
return to the store .
P/N 9FQ6P11007900_B
U.S. & Canada 1-800-922-1919 · Mexico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
REPLACING REFRIGERATION SYSTEM COMPONENTS
Only Hussmann service technicians or technicians qualified to handle R-290
(propane) refrigerant should service or repair this R-290 (propane) equipment
Failure to follow instructions can result in an explosion, death, injury and
property damage.
2-11
7 . Pull vacuum to a minimum of 200 microns or lower .
STEPS TO RECOVER REFRIGERANT
1 . Make sure you are in a well ventilated area before making any service or
repair to the refrigeration system .
2 . Disconnect all power sources from the system . Some systems may have more
than one plug or power supply .
3 . Tap system with line tap valves, attaching gauges to the high and low
sides of the system .
refrigeration line tapping valve
4 . Connect hose to an evacuated recovery tank . Open refrigeration gauges and
recovery tank .
CHARGING
A calibrated scale with +/-2 gram accuracy must be used to charge the system .
The charge amount is shown on the serial plate . Only R-290 grade refrigerant
can be used . Standard propane does not meet the purity/moisture content of
R-290, and therefore cannot be used to charge cases .
No gas charge adjustments are allowed . When connecting hoses between the
refrigeration system, manifold gauges, and refrigerant cylinder, ensure that
the connections are secure and there are no potential sources of ignition
nearby . Ensure that contamination of different refrigerants does not occur
when using charging equipment .
5 . With the suction valve in vacuum, the refrigerant will be recovered into the recovery tank .
6 . Once recovered, close the tank valve and remove the guage from the tank
and connect nitrogen tank to the system to purge it with nitrogen .
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
2-12
ELECTRICAL / REFRIGERATION
Use dedicated hoses to service R-290 (propane) refrigeration systems . Hoses or lines should be as short as possible to minimize the amount of refrigerant contained in them .
Ensure that the refrigeration system is properly grounded prior to charging the system with refrigerant, to avoid the potential for static build-up .
Extreme care must be taken not to overfill the refrigeration system . After charging, carefully disconnect the hoses, attempting to minimize the quantity of refrigerant released . Further leak check the service ports, hoses, refrigerant tanks . The service ports shall be checked for leaks using a hydrocarbon leak detector with a sensitivity of 3 grams/year (0 .106 Oz/year) leak rate .
Thoroughly leak check the service ports . If no leak is present, use a pinch- off tool to close the ends of the service tubes before brazing them shut . Remove all service ports . If a Schrader valve is used on the compressor service tube, it must be removed and the previous steps followed in order to braze the service tube shut .
Component parts shall be replaced with like components, and servicing shall be done by factory authorized service personnel only, so as to minimize the risk of possible ignition due to incorrect parts or improper service.
Refrigeration lines are under pressure. Refrigerant must be recovered before attempting any connection or repair.
— LOCK OUT / TAG OUT — To avoid serious injury or death from electrical shock, always disconnect the electrical power at the main disconnect when servicing or replacing any electrical component. This includes, but is not limited to, such items as doors, lights, fans, heaters, and thermostats.
P/N 9FQ6P11007900_B
U.S. & Canada 1-800-922-1919 · Mexico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
3-1
MAINTENANCE
CARE AND CLEANING
Do:
Long life and satisfactory performance of any equipment is dependent upon the
care it receives . To ensure long life, proper sanitation and minimum
maintenance costs, these merchandisers should be thoroughly cleaned, all
debris removed and the interiors washed down, weekly .
Exterior Surfaces The exterior surfaces must be cleaned with a mild detergent
and warm water to protect and maintain their attractive finish . NEVER USE
ABRASIVE CLEANSERS OR SCOURING PADS.
Interior Surfaces The interior surfaces may be cleaned with most domestic
detergents, ammonia based cleaners and sanitizing solutions with no harm to
the surface . Self contained models empty into a limited capacity drain pan,
which will overflow if excess water is used in cleaning .
Do NOT Use:
· Steel Wool, abrasive cleansers and scouring pads, as these will mar the
finish .
· Remove the product and all loose debris to avoid clogging the waste outlet .
· Store product in a refrigerated area such as a cooler . Remove only as much
product as can be taken to the cooler in a timely manner .
· Disconnect electrical power before cleaning .
· Thoroughly clean all surfaces with soap and hot water .
· Take care to minimize direct contact between fan motors and cleaning or
rinse water .
· Allow merchandisers to dry before resuming operation . After cleaning is
completed, turn on power to the merchandiser .
REMOVING SCRATCHES FROM (OPTIONAL) BUMPER
1 . Use steel wool to smooth out the surface area of the bumper .
2 . Clean area .
· Coarse paper towels on coated glass . · Ammonia-based cleaners on acrylic parts .
3 . Apply vinyl or car wax and polish surface for a smooth glossy finish .
· Solvent, oil or acidic based cleaners on any interior surfaces .
· Do not use steam or high pressure water hoses to wash the interior . These will destroy the merchandisers’ sealing causing leaks and poor performance .
Bumper
· Never introduce water on self-contained units with an evaporator pan .
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
3-2
MAINTENANCE
! WARNING
Refers to something you MUST NOT do.
Refers to something you MUST do.
Installation, relocation and
Electrical work
During use
storage
DO NOT
Prohibition
Do not apply strong force against, or
impact the glass surfaces when
moving themerchandiser.
Contact a licensed service
provider.
Electrical work includes :
Installation of a high-speed electric
Prohibition
DO NOT
Do not throw products into the merchandiser.
Do not put hands, apply strong
DO
Unplug the merchandiser and empty
the accumulated water from the
overflow drain pan before
moving and/or storing.
leakage breaker. Installation of a breaker for wiring.
Installation of dedicated socket with a ground.
Make sure to complete grounding
force /impact, or throw products against the glass surfaces.
Do not place any items that exceed
the specified weight onto the shelves. Do not overload the shelves with
Be sure to protection
ewqeuairpampepnrot p(PrPiaEt)e
personal
when installing or moving the
merchandiser.
Remove all products and shelving
from the merchandiser prior to
moving.
Contact Hussmann Customer Service
for assistance when relocating the
merchandiser.
work for any grounded outlet.
Follow all appropriate standards, laws and regulations regarding electrical
installation (Failure may cause a fire or electric
power leakage.)
MDN
120V / 1 60Hz, 30A
product Do not let the nightshade go until it has been securely fastened, or rolled up.
DO
Install the shelf as directed in this manual.
Installation DO NOT
Maintenance, service and
check up
In case of abnormalities or unit failure during operation, immediately stop
use and unplug from outlet electrical
Or may cause electric shock or leak
Prohibition
Do Do
not not
uinssetathll ethmeemrcehrachnadnisdeirseoruitndoa ors.
place where it can easily come into
contact with water
DO
Or may cause fire or electric shock
Contact a licensed service provider
for installation service. Or may cause injury Place the product securely on a
strong and level floor.
Prohibition
DO NOT
Or may cause electric shock
Do not clean the machine
compartment.
Do not clean the water-drainage
channel.
Do not replace or inspect the LED
lights. Do not
clean
the
moisture-wicking
plates
DO
Or may cause electric shock
outlet.
Danger of smoke, fireor electric shock
Examples of abnormalities/unit failure
YTohoreuhepsmaorwealenlrsacobomnrdeotrohmrinapgllunbgouibsrneei.cnogmes very hot.
The unit is flooded in water You feel an electric current
Please contactHussmann immediately.
Take necessary measures to prevent
Contact a licensed service provider
the merchandiser from tipping over.
to clean the machine compartment
and/or water-drainage channel.
This appliance is not intended for use
Storage and disposal
For details, please contact Hussmann Customer Service
by persons (including children) with reduced physical, sensory or mental
DO
2
Or may cause electric power leakage
and/or electric shock
Keep the product away from
rainwater.
Empty the overflow drain pan
completely when removed.
Contact a licensed service provider for
disposal of the merchandiser.
capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
For details, please contact Hussmann
Customer Service
P/N 9FQ6P11007900_B
U.S. & Canada 1-800-922-1919 · M2exico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
3-3
! WARNING
Refers to something you MUST NOT do.
Refers to something you MUST do.
During use
In case of abnormalities or unit failure
DO NOT
during operation, immediately stop use and unplug from outlet electrical
Or may cause fire, electric shock or injury
outlet.
Prohibition
Do not store explosive substances such as aerosol cans with a flammable
propellant in this merchandiser. Do not use a flammable spray near
the merchandiser or put any flammable
Danger of smoke, fire or electric shock Examples of abnormalities/unit failure
You smell something burning or hear an abnormal noise.
The power cord or plug becomes
items on the merchandiser. Do not spray water outside or
very hot. The unit is flooded in water
inside the merchandiser directly, and do
not wash the merchandiser with water.
You feel an electric current
Do not touch the control panel with a
Please contact Hussmann immediately.
wet hand.
Never disassemble, repair or reconfigure the product.
Do not insert any screws into the surface of the merchandiser
Never insert fingers, sticks, etc. into the cold air outlet, cold air inlet,
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental
capabilities, or lack of experienceand knowledge, unless they have been
air intake opening, air discharge
opening, or any moving parts. Or may cause injury due to collapse,
tipping, or damage of the unit Do not step on the unit. Do not place anything
on the unit. Or may cause flame or explosion
given supervision or instruction concerning use of the appliance by
a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
Do not use any electric appliances
The expected lifespan of the moisture
inside the merchandiser.
wicking plates will differ in accordance
Risk of damage to health Never keep any medicines in the
merchandiser.
with the operating environment, absorption will deteriorate with dust, oil, and other forms of soiling. The wicking plate should be replaced at
DO
least once per year.
2
Or may cause flame or explosion
Use the unit only to display and
merchandise food and beverages.
2
(Use for other purposes could result
in a deterioration in quality of the
displayed merchandise)
In the event of a gas leak, open a window for ventilation, and
do not touch the unit or electrical
plug.
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
3-4
MAINTENANCE
CLEANING STEEL SURFACES (available only with stainless steel models)
CLEANING CONDENSER COILS
Use non-abrasive cleaning materials, and always polish with grain of the steel
. Use warm water or add a mild detergent to the water and apply with a cloth .
Always wipe rails dry after wetting .
Use alkaline chlorinated or non-chlorine containing cleaners such as window
cleaners and mild detergents . Do not use cleaners containing salts as this
may cause pitting and rusting of the steel finish . Do not use bleach .
Condenser coils should be cleaned at least once per month . Additional
cleaning may be needed depending on the operational environment . A dirty
condenser blocks normal airflow through the coils .
Airflow blockage increases energy consumption and reduces the merchandiser’s
ability to maintain operating temperature .
Disconnect the power cord .
DO NOT FLOOD!
Use only enough water necessary to clean surface. Water must not drip down the
case!
Never use ammonia based cleansers, abrasive cleansers, or scouring pads.
— LOCK OUT / TAG OUT — To avoid serious injury or death from electrical shock,
always disconnect the electrical power at the main disconnect when servicing
or replacing any electrical component. This includes, but is not limited to,
such items as doors, lights, fans, heaters, and thermostats.
Remove the two screws of the front panel, then pull out the panel .
Remove the 8 screws in the area shown by the figure .
To clean the coils, use a vacuum cleaner with a wand attachment and a soft
(non-metallic) brush to remove dirt and debris . Do not bend coil fins .
Always wear gloves and protective eye wear when cleaning near sharp coil fins
and dust particles .
Shut Fans Off during cleaning process. Do NOT use HOT water on cold glass
surfaces. This can cause the glass to shatter and could result in personal
injury. Allow glass surface to
warm before applying hot water.
P/N 9FQ6P11007900_B
U.S. & Canada 1-800-922-1919 · Mexico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
3-5
CLEANING HONEYCOMB
Clean periodically once a month .
If the honeycomb is not too dirty, tap honeycomb lightly to remove the dust .
If the honeycomb is filthy, rinse off with water . Take care not to bend or
mark the honeycomb . To remove the honeycomb, pull the honeycomb removal
fixtures (two per honeycomb) down, and pull the honeycomb down and out .
To secure the honeycomb, push the entire honeycomb into the discharge air
outlet, beginning from the end, position it horizontally, and push the anchor
tabs on the honeycomb removal fittings until they are aligned with the
honeycomb engagement groove . The honeycomb is at its optimum position when
the groove and tab positions are aligned properly .)
Discharge air outlet
Honeycomb removal fixtures
Honeycomb
Honeycomb anchor tab
Honeycomb engagement groove
Condition of being removed
Honeycomb removal fixtures
PP marked with left rear
Honeycomb
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
3-6
MAINTENANCE
CLEANING POWER PLUG
CLEANING DRAIN EVAPORATION
SYSTEM
Cleaning the system requires disassembly . This
merchandiser has an evaporation device that
Unplug
consists of 2 evaporation trays, and upper tray,
and lower tray . Drain water goes to the upper
tray first to evaporate, and any remaining
Remove the power plug from the power
water that does not evaporate will flow to the
socket and clean off the dust and dirt on the
lower tray . The waste water then flows to the
terminals . Also clean off the dust and dirt on overflow drain pan .
the power cord and the surrounding . After cleaning, wait 5 minutes before plugging the
Remove accumulated debris from the
power plug back into the power socket . Check evaporation pan .
to ensure cord is not damaged or cracked .
Contact Hussmann for a replacement cord, or Debris or dirt accumulation inside the trays
a licensed service provider .
or on the condenser will reduce evaporation
capacity . Details of the evaporation system
unit are shown on the next page .
Dust or dirt may accumulate within a short period depending on the conditions
of the installation place or the environment for use. Check when cleaning.
Wicking plate MUST be
changed at least once a year.
Evaporation System may be Hot! and pose risk of bodily injury Always Wear
gloves
and protective eye wear when servicing. Turn off power and allow to cool
before servicing.
CHANGING MOISTURE WICKING PLATES
Wicking plates must be replaced at least once per year . The expected life
span of the moisture wicking plates will differ in accordance with the
installation environment, but absorption capabilities will deteriorate with
dust, oil and other forms of soiling . The wicking plates are shown in the
illustration on the next page .
Contact your Hussmann representative for replacement parts .
P/N 9FQ6P11007900_B
U.S. & Canada 1-800-922-1919 · Mexico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
Condenser
3-7
Moisture Wicking Plate #1
Moisture Wicking Plate #2 (located under wicking plate #1)
Fan Motor
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
3-8
MAINTENANCE
NIGHT CURTAIN (Optional)
Use the night curtain after business hours and during non-business days to
save energy .
To use the night curtain:
1 . Grasp the handle and pull downward . Hook the handle over the night
curtain hook located on the backside of handrail .
2 . Avoid the night curtain sheet touching the price tag molding or items
placed inside the case .
Night Curtain Pull down
Night Curtain Night Curtain hook Return air inlet Deck pan
P/N 9FQ6P11007900_B
U.S. & Canada 1-800-922-1919 · Mexico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
4-1
SERVICE
IN CASE OF THE FOLLOWING:
LED Lamp does not work:
When moving the case a long distance:
Contact your Hussmann representative to replace LED lamp fixtures . Fixtures must be replaced with like fixtures .
Use a trolley . Caution must be observed when moving the case to prevent it from toppling over if it is tilted more than necessary .
When not using the merchandiser for a long period of time:
Remove all items from the merchandiser, and the power plug from the power
socket . Clean the inside of the cabinet, and wipe away any moisture . Make
sure not to store the unused case in a place where children can play .
Damage to the power cord or plug: If the cord is damaged, unplug the cord, and
contact your Hussmann representative for replacement . Do not allow the wheels
of the merchandiser to rest on the cord .
LED POWER SUPPLY LOCATION
The LED driver delivers DC power to the LED Lamp . The power supply is located
behind the panel on the righthand side of the case . If it is determined that
the power supply is not working and needs to be replaced, replace it with like
components . Failure to place with a similar rated power supply will cause the
LED lamp to be damaged or not work properly .
LED Driver (Power Supply)
Water on the floor: If there is water around the merchandiser, check overflow drain pan underneath the case, and dispose of any accumulated water or dirt in the pan . Wicking plates may need replacement .
— LOCK OUT / TAG OUT — To avoid serious injury or death from electrical shock, always disconnect the electrical power at the main disconnect when servicing or replacing any electrical component. This includes, but is not limited to, such items as doors, lights, fans, heaters, and thermostats.
Product will be degraded and may spoil if allowed to sit in a non-refrigerated area.
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
4-2
SERVICE
TROUBLESHOOTING
INVESTIGATE TROUBLE ACCORDING TO THE FOLLOWING TABLE: Try performing the check points and actions to solve the problem . If the merchandiser does not work correctly, or you hear an abnormal noise, smell something abnormal or smoky, immediately stop using the merchandiser and remove the plug from the power socket . Remove all items from the merchandiser, and then inform the “necessary information” to the supplier or dealer where you purchased the merchandiser or a licensed service provider .
Symptom
Check points
Actions
The case can not get cold at all
The power plug is disconnected . The power supply is cut off .
The breaker for wiring is operated . The electric leakage breaker was operated
.
The case
The wind is hitting the merchandiser .
is not cold enough The ambient temperature, humidity
excessively high .
Insert the power plug in securely .
Confirm the recovery .
Contact the supplier or dealer where you purchased the merchandiser or a
licensed service provider .
Keep the wind speed less than 47 .2 FPM (0 .2 mps) .
Refer to Page 1-1 for recommended operating ambient temperatures .
The merchandiser is installed in direct sunlight, Move the location of the installation . Refer to
or near an oven or stove .
“Location” on page 1-1 and 1-2 .
The setting of the temperature is high .
Refer to “Controls and Adjustments” on page 2-3 .
The items are inserted without pre-cooling .
The items close off the discharge air inlet or discharge air outlet .
Refer to Page 1-1 for location requirements .
The items are placed at the air inlet opening or Do not place items hindering ventilation . air outlet opening of the condenser .
The condenser is clogged .
Refer to “Cleaning Drain Evap . System” on Page 3-6 .
The drain pan tray is dirty .
Clean periodically as needed .
The case is
The case is installed on an unstable floor .
making an odd or
loud noise .
The case does not stand up correctly .
Place the merchandiser securely on a strong and level floor .
The rear of the case is touching a wall .
Move the merchandiser away from a wall .
Dew formation outside of the case .
For a while after starting the case, you may hear some noise from the
compressor . However, it will decrease soon .
On hot summer days, or depending on the location of the installation, a dew
may stick to the outer surface of the merchandiserespecially the glass surface
. In case of high humidity, a dew is formed by touching cold objects to the
moisture in the air, so it is not a malfunction . When the dew is attached,
wipe off with a dry cloth . These case models are designed for operation in
Type II or below environments .
P/N 9FQ6P11007900_B
U.S. & Canada 1-800-922-1919 · Mexico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
DIRECT DRAIN
The evaporation system can be modified for a direct floor drain .
xample of
Disconnect the power cord .
Remove 2 screws of the front panel, then the panel itself .
Remoovvee88scscrerwews isninthtehaereaareshaoswhnowbyn by
initnhethfiegufirgeu. re .
SStep 11
UUnnpplluugg
Pull out the unit. .
4-3
FFrroonntt ppaanneell
Display Case
Unit Evaporation tray
Condensing Unit Cassette
RReemmoovvee 33 screws attached too tthheeeevvaappoorraattiioonnttrraayy
(M(Maarrkkeeddwwiitthh in itnhethfeigfiugrueraetartigrihgth .t).)
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
4-4
SERVICE
Remove upper moisture wicking plates.
Remove 6 screws from the 2 brackets that attach to the evaporation pipe. Then
remove evaporation tray assembly. (Do not remove the evaporation pipe.)
Upper moisture wicking plates (Not needed after modification)
Bracket
Evaporation tray assy
Remove 4 screws that attach to the lower evaporation tray and lower moisture
wicking plate. Then remove the tray assembly and the moisture wicking plate.
Screws
Lower moisture wicking plates (Not needed after modification)
Screws
Attach a drain hose to the socket on the upper evaporation tray.
Then apply a hose band to fix.
Hose Band Hose Band
Refrigeration System Tray
Socket Socket
P/N 9FQ6P11007900_B
Drain hose
U.S. & Canada 1-800-922-1919 · Mexico
01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
4-5
Apply caulking on drain hose connection to prevent water leaks.
Apply caulk
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
4-6
SERVICE
- Need to replace circled parts with new pictures
MDN Visual Depiction on Non-Incendive Replacement Parts
Main Switch
Light Switch
Solid State Relay
Control RTN400
Control Display KDE
Component parts are specifically chosen for propane exposure and therefore
non-incendive
and non-sparkling. Component parts shall be replaced with identical
components, and servicing shall be done by factory authorized service
personnel only, so as to minimize the risk of possible ignition due to
incorrect parts
or improper service.
P/N 9FQ6P11007900_B
U.S. & Canada 1-800-922-1919 · Mexico 01 800-890-2900 · www.hussmann.com
P/N 9FQ6P11007900_B
MDN 3575 Replacement Parts List
Item Part Number
Description
1 3089733
LED-ES ULTRA CNPY 36IN 4000K
2 3074549
SWITCH-TGL SPST 15A 125V mfg.1NT91-2
3 3132257
COIL MDN35 4384724.5
4 9FQ2433061100 TUBE-CAPLILLARY ID 0.08IN X 170IN
5 9FQ2136054302 EXTER PANEL FTN MDN 3FT
6 3037477
CONDENSER 24 IN X 8.5 IN
7 3119618A
FILTER DRIER R-290 0.25 ODF
8 3082149A
BLADE-FAN 8 IN CCW
9 3082147
MOTOR-13W 70-264V NSC
10 4FL2422022600 EVAPORATOR
11 9FQ2460068500 COMPRESSOR NT2210U 120V R290 1.25HP
12 3117868A
POWER SUPPLY – 4A 24V 96W
13 3023537B
CONTROL-ELIWELL RTN400
14 3023554B
SENSOR-NTC 4 METER GREEN
15 3031571A
SENSOR-NTC 4 METER ORANGE
16 3023553D
CONNECTOR-5 MTS CABLE CO000227
17 9FQ4F30002000 EMC FILTER RSEL2002A
18 9FQ4S20001900 RELAY DPDT 30ANO_10aNC 230VAC
19 9FQ4S22002200 MAIN SWITCH CIRCUIT BREAKER AA 1-BO-44-630-1D1-1 30
20 9FQ0423036300A FAN PACK CONNECTOR AS
21 9FQ0039014902 BLACK PAINTED SHELF KIT ASSY
22 9FQ2224009302 INNER GLASS BLACK
23 9FQ2224009402 INNER GLASS BLACK
24 9FQ2140058602 PAINTED BLACK EXTER TOP MDN 35
25 9FQ2129060202 PAINTED BLACK EXTER COVER MDN L
26 9FQ2129070302 PAINTED BLACK EXTER COVER R B1A
27 9FQ0022030902 PAINTED BLACK DECK PAN ASSY MDN 3FT
28 9FQ2136047902 BLACK EXTER PANEL R290
29 3023552B
CONTROL-DSPL KDE
30 9FQ2180004702 PAINTED BLACK TRIM
Qty per case 1 1 1 1 1 1 1 2 2 2 1 1 1 1 1 1 1 1 1 1 5 1 1 1 1 1 1 1 1 2
4-7
Component parts are specifically chosen for propane exposure and therefore
non-incendive and non-sparkling. Component parts shall be replaced with
identical components, and servicing shall be done by factory authorized
service personnel only, so as to minimize the risk of possible ignition due to
incorrect parts
or improper service.
HUSSMANN CORPORATION · BRIDGETON, MO 63044-2483 U.S.A.
Open Vertical Merchandisers
MDN4775 Replacement Parts List
Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Part Number
Description
3089734C
LED-ES ULTRA CNPY 48IN 4000K
3074549
SWITCH-TGL SPST 15A 125V mfg.1NT91-2
9FQ0422034100 COIL-MDN47 438-4-6-36.5
3037649A
CAPILLARY-TUBE.054INIDX130INLG
9FQ2136058302 PAINTED BLACK EXTER PANEL MDN 47
9FQ0413034200 CONDENSER 30IN X 8.5IN DOUBLE C
3119618A
FILTER DRIER R-290 0.25 ODF
3082149A
BLADE-FAN 8 IN CCW
3082147
MOTOR-13W 70-264V NSC
4FL2422022000 EVAPORATOR
4FL2422022500 EVAPORATOR
3117868A
POWER SUPPLY – 4A 24V 96W
3023537B
CONTROL-ELIWELL RTN400
3023554B
SENSOR-NTC 4 METER GREEN
3031571A
SENSOR-NTC 4 METER ORANGE
3023553D
CONNECTOR-5 MTS CABLE CO000227
9FQ4F30002000 EMC FILTER RSEL2002A
9FQ4S20001900 RELAY DPDT 30ANO_10aNC 230VAC
9FQ4S22002200 MAIN SWITCH CIRCUIT BREAKER AA 1-BO-44-630-1D1-1 30
9FQ0423036300A FAN PACK CONNECTOR AS
9FQ0039012102 SHELF BLACK KIT ASSY
9FQ2224009302 INNER GLASS BLACK
9FQ2224009402 INNER GLASS BLACK
9FQ2140062402 PAINTED BLACK PAINTED EXTER TOP
9FQ2129060202 PAINTED BLACK EXTER COVER MDN L
9FQ2129070302 PAINTED BLACK EXTER COVER R B1A
9FQ0022030802 PAINTED BLACK DECK PAN ASSY MDN 45
9FQ2136048202 PAINTED BLACK EXTER PANEL 4FT R290
3023552B
CONTROL-DSPL KDE
9FQ2180004702 PAINTED BLACK TRIM
3093957B
COMPRESSOR-R290 115 V 2168U
Qty per case 1 1 1 2 1 1 2 3 3 1 1 1 1 1 1 1 1 2 1 1 5 1 1 1 1 1 1 1 1 2 2
Component parts are specifically chosen for propane exposure and therefore
non-incendive and non-sparkling. Component parts shall be replaced with
identical components, and servicing shall be done by factory authorized
service personnel only, so as to minimize the risk of possible ignition due to
incorrect parts
or improper service.
To obtain warranty information or other support, contact your
Hussmann representative. Please include the model and serial number of the
product.
Hussmann Corporation, Corporate Headquarters: Bridgeton, Missouri, U.S.A.
63044-2483 01 October 2012
Hussmann Corporation
12999 St. Charles Rock Road Bridgeton, MO 63044-2483 www.hussmann.com