PARTS LIST

Superday H07BN020 10-12 Rifle Safe with LED Light 1

Installation Steps:

Superday H07BN020 10-12 Rifle Safe with LED Light 2

Superday H07BN020 10-12 Rifle Safe with LED Light 3

Superday H07BN020 10-12 Rifle Safe with LED Light 4

WARNING:

Tip Over Hazard

  • A child or adult can tip the safe and be killed or seriously injured.
  • Serious injury may occur to children and adult if not secured before installation.
  • Children should not play with or around the safe at an time.

DY2202 SAFE FINGERPRINT LOCK PRODUCT USER MANUAL

Product name: DY2202 fingerprint buzzer with noise reduction (regular model)
Version : V 1 .2
Tip : please do not leave the emergency keys & external power box in your safe!

Superday H07BN020 10-12 Rifle Safe with LED Light 5

SYSTEM POWER ON
In the initial state, any fingerprint can open the safe. Initial management password 123456.

ADD FINGERPRINT

  1. Register fingerprint: After opening the safe, briefly press the green button inside the safe (fingerprint login button). After hearing two short beeps of “Didi”, the status light will light up. At this time, collect fingerprints 4 times at the collector position. Hearing a “Didi” sound followed by a long beep indicates successful fingerprint registration. (For example, if there are three short beeps of “Didi”, “Didi”, and “Didi”, registration fails.) Other fingerprints can be registered using this method. Up to 30 pieces can be registered (can be added according to user needs).
  2. Registration administrator password: After the safe is opened, touch to wake up the touch screen. Press the number 00, then press the green button inside the box (code change switch), enter the new password, and end with the# key. The password has 3-12 digits.
  3. Register a regular user password: After the safe is opened, touch to wake up the touch screen. Press the number 11, then press the green button inside the box (code change switch), enter the new password, and end with the# key. The password has 3-12 digits.

DELETE FINGERPRINT AND PASSWORD
In standby mode, press and hold the green key (fingerprint Delete key) in the box (about 5s) to hear a long sound of “drop”, indicating that all fingerprints and passwords have been deleted successfully, and the factory settings have been restored. Any fingerprint can be opened.

FINGERPRINT UNLOCK

  1. Verify with registered fingerprints. Place your finger on the fingerprint module.
  2. If the recognition is successful, a long beep of “drip” will be heard, the electromagnet will adsorb, and the panel will display the lock open status.
  3. If the recognition is not successful, you will hear several mismatched tinkling bells, and the panel will display that the lock has not been opened.

PASSWORD UNLOCK

  1. Touch to wake up the touch screen and enter the user set 3-12 digit password.
  2. If the recognition is successful, a long beep of “drip” will be heard, the electromagnet will adsorb, and the panel will display the lock open status.
  3. If the recognition is not successful, you will hear several mismatched tinkling bells, and the panel will display that the lock has not been opened.

ALARM OPERATION

  1. Touch to wake up the touch screen in sleep mode, press the* key to hear a “drip” sound, and the number button light goes out, indicating that the alert state has been entered. The safe will alarm when it is vibrated. After the alarm, enter the correct fingerprint or password. The electromagnet is engaged for 5 seconds, and the alert state is automatically released. If the correct fingerprint is not entered for 30 seconds, the alarm will automatically stop, but the alert will not be lifted.
  2. If the fingerprint and password are entered incorrectly for more than 3 (5) times, an alarm will sound for 30 seconds.

SOUND ON AND OFF
Touch to wake up the touch screen, enter “11 #” to turn all sounds on or off.

LOW VOLTAGE REMINDER:

  1. The system uses four 1.5V Alkaline battery. If the voltage is insufficient, the buzzer will remind the user of “drop, drop, beep” and “drop, drop, beep” twice after the door is opened, reminding the user to replace the battery in time when the power is low.
  2. If the battery voltage is insufficient, emergency power or mechanical emergency key can be used to open the door.

SYSTEM INITIALIZE:

Long press the green button on the mechanism for 5 seconds, and the system will restore initialization settings, clear all fingerprints and passwords.

SYSTEM PARAMETER:

  • Working voltage: 42V~6.8V
  • Standby current:< 50uA
  • Under voltage reminder: 4.5±0.2
  • Fingerprint capacity: 30

IMPORTANT NOTE:

To improve the accuracy of fingerprint recognition, users ccc refer to the following suggestions.

  1. Suggest registering 2-3 fingerprints per user
  2. It is recommended that women and children register their thumb and middle finger as much as possible
  3. Press the fingers evenly as much as possible, and do not apply too much force or too lightly. It is recommended to apply light force to the fingers
  4. Suggest registering fingerprints from multiple perspectives
  5.  When selecting batteries1 it is recommended to use high-quality high-performance Alkaline battery. Do not use inferior or counterfeit batteries and any carbon batteries.