KEMET NBL45282H-A3 Langevin Bolt On Transducers Instruction Manual

June 17, 2024
KEMET

Piezoelectric Transducers
**NBL Langevin Bolt-on Transducers

**

Overview

KEMET’s Langevin-type transducers are used whereever powerful ultrasonic waves must be generated. For application flexibility and ease of installation, these transducers are mounted in a structure that can be bolted virtually anywhere.
KEMET’s high-performance ceramic material NEPEC® N-61 is excellent for use in these Langevin transducers. KEMET produces a number of this type of transducers, all featuring high quality and excellent output levels, and all based on a unique proprietary design.

Applications

  • Cleaning equipment
  • Ultrasonic treatment machines
  • Welders for plastic

Benefits

  • High mechanical Q and excellent electro-acoustic conversion efficiency, providing a high output amplitude
  • High speed of vibration due to piezoelectric element
  • Fast and easy installation
  • High reliability
  • Operating temperature range from −40°C to +120°C
  • Good amplitude linearity due to N–61 ceramics’ extended temperature range
  • RoHS/REACH compliant

Ordering Information

NBL 45 28 2 H A 3
Series Diameter of

Acoustic Wave
Radiation| Resonant
Frequency| Number of
Piezoelectric
Elements| ConstructionType| Radiation
Surface| Model
Type
NBL| 15 = φ 15 mm
20 = φ 20 mm
45 = φ 45 mm| 28 = 28 kHz
40 = 40.2 kHz
60 = 60 kHz| 2 = 2 elements| H = Horn construction
(output surface has step or horn shape) S = Straight construction| Blank = Not available for
treatment machines type
A = Threaded type for cleaning
equipment| Blank
3

Dimensions in mm

KEMET NBL45282H-A3 Langevin Bolt On Transducers - Dimensions in
mm

Environmental Compliance

All KEMET Piezoelectric Transducers are RoHS and REACH compliant.
Article 33(1) of the REACH Regulation states that manufacturers and importers of articles (products) are required to notify their customers of the presence of any Substances of Very High Concern (SVHC) in their products exceeding 0.1% by weight and provide instructions on safe use of the product.
KEMET Corporation reports regarding the Article 33(1) of REACH Regulation as follows:

  1. Applicable Product:
    Piezoelectric transducers (NBL Series).

  2. Report for content of REACH SVHC list:
    The product(s) above contain a substance by more than 0.1wt% per product weight that was published in the 8th update of the REACH SVHC substances (December 19, 2012).

  3. Regarding safety of the piezoelectric transducers (Piezoceramic products):
    The Piezoceramic that is used in this product becomes ceramic by sintering powder containing PZT as a main ingredient.
    It is chemically stable, with minimum risks toward the human body or environment within the intended use of the product.
    Please note that risks could occur in the case of inhalation or accidental oral uptake of powder ceramics.

  4. Technical product information on the piezoelectric transducers (Piezoceramic products):
    The manufacturing technique of the “piezoceramic products” whose main ingredient is Lead Titanium Zirconium Oxide (PZT) has been established, and there is no alternative material that can exhibit superior performance than PZT at this moment. Please note that the piezoceramic is listed as an exempt on RoHS (2011/65/EU) Annex III (7c.1).

  5. Responsibility of piezoceramic manufacturers:
    Piezoceramic manufacturers report information regarding PZT containment in their products to the customers to obey the article 33 of the REACH regulation.

Performance Characteristics

Item Performance Characteristics
Operating Temperature Range −40 to +120°C
Recommended Storage Condition −20 to +80°C
Resonant Frequency Range 28 – 60 kHz
Maximum Allowable Power Range 2.5 – 50.0 W

Table 1 – Ratings & Part Number Reference

Part
Number| Resonant
Frequency
(kHz)| Dynamic
Admittance
(mS)| Mechanical
Q| Static
Capacitance
(pF)| Maximum
Allowable
Velocity
(cm/S)| Maximum
Allowable
Power
(W)| Application| Horn
Plate| Backing
Plate| Weight
(g)
---|---|---|---|---|---|---|---|---|---|---
NBL45282H-A3
NBL45402H-A
NBL15602S
NBL20602S| 28.0 40.2 60.0 60.0| 40152520| 500500500400| 4,000
4,000
850
1,250| 40505040| 50
50′
2.9
3.72| Cleaning equipment Cleaning equipment Treatment machines Treatment machines| Alminium Alminium Alminium Alminium| Strainless Steel
Strainless Steel
Alminium
Alminium| 4002403035

  1. Maximum allowable power based on data where one unit is measured with a water load on one side.
  2.  Maximum allowable input in no-load state.

Electrical Characteristics

KEMET NBL45282H-A3 Langevin Bolt On Transducers -
Temperature

Horn Installation Reference Example

KEMET NBL45282H-A3 Langevin Bolt On Transducers - Horn Installation
Reference Example Vibration

KEMET NBL45282H-A3 Langevin Bolt On Transducers -
Vibration

Packaging

Part Type Packaging Type Pieces per Box
NBL45282H-A3 Tray 30

NBL45402H-A
NBL15602S| 160
NBL20602S

Handling Precautions

Precautions to be taken when using piezoelectric transducers (Please read these precautions before using our products)
Material selection, installation and activation of piezoelectric ceramics should be decided upon by users according to the applications. For proper evaluation and decision, products should be tested repeatedly in both realistic and abnormal operating conditions.KEMET NBL45282H-A3 Langevin Bolt
On Transducers - conditions

  • Do not disassemble the product or remove the screw.
  • Avoid excessive physical shock. Otherwise, the internal piezoelectric ceramic element may be damaged.
  • Do not apply power exceeding its maximum allowance.
  • Store the transducers preferably at ordinary temperatures (-20˚C to +80˚C). Avoid condensation on the product’s surface.
  • Handle products properly as industrial waste. When disposing, please contact your local waste disposal service and make sure the disposal methods meet all legal requirements.
  • Transducers’ stock should be used promptly, preferably within 1 year of receipt.

Export Control

For customers in Japan
For products which are controlled items subject to the “Foreign Exchange and Foreign Trade Law” of Japan, the export license specified by the law is required for export.
For customers outside Japan
Piezoelectric Transducers should not be used or sold for use in the development, production, stockpiling or utilization of any conventional weapons or mass-destructive weapons (nuclear weapons, chemical or biological weapons, or missiles), or any other weapons.

KEMET Electronics Corporation Sales Offi ces

For a complete list of our global sales offi ces, please visit www.kemet.com/sales.

Disclaimer

YAGEO Corporation and its affi liates do not recommend the use of commercial or automotive grade products for high reliability applications or manned space fl ight.
All product specifi cations, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are not intended to constitute – and KEMET specifi cally disclaims – any warranty concerning suitability for a specifi c customer application or use.
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicated or that other measures may not be required.

KEMET is a registered trademark of KEMET Electronics Corporation.
© KEMET Electronics Corporation
• One East Broward Boulevard
Fort Lauderdale, FL 33301 USA
954-766-2800
www.kemet.com
D0001_NBL • 8/10/2023

Documents / Resources

| KEMET NBL45282H-A3 Langevin Bolt On Transducers [pdf] Instruction Manual
NBL45282H-A3 Langevin Bolt On Transducers, NBL45282H-A3, Langevin Bolt On Transducers, Bolt On Transducers, Transducers
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals