STIEBEL ELTRON CNS 50 Trend UK Wall-Mounted Convector Heater
Product Information
Specifications
- Product: Wall mounted convector heater
- Manufacturer: Stiebel Eltron
- Model: CNS Trend UK
- Website: www.stiebel-eltron.com
Product Usage Instructions
Operation
The operation section provides details on how to use the convector heater effectively and safely.
1. General Information
Ensure to read the safety instructions and understand the information provided in the documentation.
2. Safety
Follow the intended use guidelines and adhere to the general safety instructions and test symbols.
Installation
Proper installation is crucial for the efficient functioning of the convector heater.
8. Safety
Adhere to general safety instructions, standards, and regulations during the installation process.
10. Installation
Follow the steps to install the wall mounting bracket, connect the appliance electrically, and commission it properly.
FAQ
Special Information
-
* **Keep children away:** Children under 3 should be kept away from the appliance without supervision.
- Supervision: Children aged 3-7 can operate the appliance under supervision.
SPECIAL INFORMA TION
- Keep children under the age of 3 away from the appliance if constant supervision cannot be guaranteed.
- Children from the age of 3 to 7 may switch the appliance on and off, provided they are supervised or have been instructed in the safe operation of the appliance and understand any risks that may result. This is subject to the appliance having been installed as described. Children from the age of 3 to 7 must not regulate the appliance.
- The appliance may be used by children aged 8 and older and persons with reduced physical, sensory or mental capabilities or a lack of experience and know-how, provided that theyare supervised or they have been instructed on how to use the appliance safely and have understood the potential risks.
- Children must never play with the appliance. Children must never clean the appliance or perform user maintenance unless they are supervised.
- Parts of the appliance can get very hot and may cause burns. Particular caution is advised when children or vulnerable persons are present.
- In order to avoid overheating, do not cover the heater.
- Never install the appliance directly below a wall socket.
- In the case of a permanent connection, the appliance must be able to be separated from the power supply by an isolator that disconnects all poles with at least 3 mm contact separation.
General information
- The power cable must only be replaced (for example if damaged) by a qualified contractor authorised by the manufacturer, using an original spare part.
- Secure the appliance as described in chapter “Installation / Installation
OPERATION
General information
The chapters “Special information” and “Operation” are intended for both users and qualified contractors. The chapter “Installation” is intended for qualified contractors.
Note
Read these instructions carefully before using the appliance and retain them for future reference. Pass on the instructions to a new user if required
Safety instructions
Structure of safety instructions
KEYWORD Type of risk Here, possible consequences are listed that may result from failure to observe the safety instructions. steps to prevent the risk are listed.
Symbols, type of risk
Keywords
Other symbols in this documentation
Note
General information is identified by the adjacent symbol. Read these texts carefully.
This symbol indicates that you have to do something. The action you need to take is described step by step
Information on the appliance
Units of measurement
Note
All measurements are given in mm unless stated otherwise
Safety
Intended use
This appliance is designed to heat living areas. The appliance is intended for domestic use. It can be used safely by untrained persons. The appliance can also be used in a non-domestic environment, e.g. in a small business, as long as it is used in the same way. Any other use beyond that described shall be deemed inappropriate. Observation of these instructions and of the instructions for any accessories used is also part of the correct use of this appliance.
Appliance description
General safety instructions
WARNING Injury
- Keep children under the age of 3 away from the appliance if constant supervision cannot be guaranteed.
- Children from the age of 3 to 7 may switch the appliance on and off, provided they are supervised or have been instructed in the safe operation of the appliance and understand any risks that may result. This is subject to the appliance having been installed as described. Children from the age of 3 to 7 must not regulate the appliance.
- The appliance may be used by children aged 8 and older and persons with reduced physical, sensory or mental capabilities or a lack of experience and know-how, provided that they are supervised or they have been instructed on how to use the appliance safely and have understood the potential risks.
- Children must never play with the appliance. Children must never clean the appliance or perform user maintenance unless they are supervised.
WARNING Injury
- In closed rooms, temperatures can rapidly reach high values. Ensure constant supervision if the appliance is operated in a small room and the persons within that room cannot regulate the appliance or leave the room on their own.
WARNING Burns
Never operate this appliance…
- if the distance from adjacent objects or other flammable materials would be less than the minimum permissible distance.
- in rooms where it is at risk of fire or explosion as a result of chemicals, dust, gases or vapours. Ventilate the room sufficiently before heating.
- in the direct proximity of pipes or receptacles that carry or contain flammable or explosive materials.
- if an appliance component is damaged, the appliance has fallen over or there is a fault.
WARNING Burns
- Never place any flammable, combustible or insulating objects or materials on the appliance or in direct proximity to it.
- Ensure that the air intake and discharge are never blocked.
- Never place any objects between the appliance and the wall.
WARNING Burns
- The appliance is unsuitable for use as a floor standing appliance. Only ever operate this appliance when mounted on the wall mounting bracket supplied (see chapter “Installation / Installation”).
CAUTION Burns
- Parts of the appliance can get very hot and may cause burns. Particular caution is advised when children or vulnerable persons are present.
Test symbols
See type plate on the appliance.
Appliance description
The appliance is a wall-mounted electric direct heater. The appliance is suitable for use as a standalone heating system, or can be used in spring and autumn and as a booster heater in smaller rooms. The air inside the appliance is heated by a heating element and expelled via natural convection through the air discharge at the top. Cool indoor air is drawn in through the air intake on the underside of the appliance. When the set room temperature is reached, it is maintained by periodic heating.
Operation
- Programming unit
- ON/OFF switch
Programming unit
The programming unit is located at the top right of the appliance.
- Display
- User interface
User interface
Display
If no user action occurs for 20 seconds, the backlight switches off. Press any button to switch the background lighting on again
Symbols
Switching the appliance on and off
Note
For a short time after initial start-up and after longer breaks in use, a smell may develop
The appliance is ready for operation as soon as it has been fixed to the installation wall and hard-wired to the power supply. switch the appliance on or off using the ON/OFF switch on the right-hand side of the appliance. switch the appliance off when not in use for longer periods (e.g. during the summer months). All settings remain intact after switching off or after an interruption to the power supply. This appliance is equipped with a power reserve that ensures the day of the week and the time are saved for several hours.
Note
If the appliance was in timer mode before being switched off for a longer period of time, you will be prompted to set the day and time after switching it on. Until this setting is made, the appliance will operate in comfort mode.
Standby mode
Material losses
In standby mode, the appliance will not switch on heating under any circumstances. There will be no frost protection.
- To switch on the programming unit, press “Standby”. The standard display appears.
- To put the programming unit and the heating appliance into standby mode, press “Standby”. The display shows “- – – -“.
Settings
Standard display
The default display is continuously displayed. If no user action is performed for longer than 20 seconds while in the menu, the appliance automatically switches to the default display. The default display shows the current set room temperature as well as the “Editable parameter” symbol. You can use “+” and “–” to change the set room temperature. If the set room temperature corresponds to one of the values set for the comfort or setback temperature, the symbol for the corresponding operating mode (comfort mode, setback mode) appears in the menu bar. The set room temperature can also be changed manually when in timer mode. The changed set room temperature is maintained until the next programmed switching point is reached.
Standard menu
To access the standard menu, briefly press “Menu”. You can now call up the following menu items:
To change the setting of a menu item, call it up by pressing “+” and “–”. Press the “OK” button. As soon as the “Editable parameter” symbol appears, you can change the setting of the menu item with “+” and “–”. Press “OK” to save the setting. To exit the standard menu, briefly press “Menu”. The standard display appears.
Configuration menu
In the configuration menu, you can call up actual values, program time programs for timer mode and set parameters. To access the configuration menu, press and hold “Menu”. After approx. 3 seconds, actual value I1 is displayed. Use “+” and “–” to switch between the individual actual values, time programs and parameters. To exit the configuration menu, briefly press “Menu”. The standard display appears.
Actual values
The following actual values can be called up:
Note
The counter for relative heating time (I2) counts in complete hours how long the appliance heats for. When the appliance is switched off, any heating phase of less than 60 minutes is not recorded.
Time programs
There are three time programs available for using the appliance in timer mode. Time programs Pro1 and Pro2 are factory-set. Time program Pro3 can be set according to your individual requirements.
Note
To use timer mode, select the required time program in the standard menu (see chapter “Settings / Standard menu”).
Note
Ensure the day of the week and the time are set correctly when setting the time programs
Note
The following applies to all time programs (Pro1, Pro2, Pro3): If the end time is later than 23:59 h, the end time will automatically be moved to the next day of the week. The comfort phase is maintained past midnight and will end on the next day at the set end time.
Time programs Pro1 and Pro2
You can specify the comfort mode start and end times with time programs Pro1 and Pro2. During this time period, the appliance heats to the set comfort temperature. Outside this specified time period, the appliance operates in setback mode. This results in a comfort and a setback phase that are repeated daily (Pro1) or every weekday (Pro2).
Theses phases are factory-set as follows:
- 08:00 h – 22:00 h: Comfort mode
- 22:00 h – 08:00 h: Setback mode
Note
When time program Pro2 is enabled, the appliance operates exclusively in setback mode during the weekend.
To adapt time programs Pro1 and Pro2 according to your needs, proceed as follows:
- In the configuration menu, use “+” and “–” to call up the required time program.
- Press the “OK” button.
- The start time for comfort mode is displayed.
- Use “+” and “–” to set the required start time.
- Press the “OK” button.
- The end time for comfort mode is displayed.
- Use “+” and “–” to set the required end time.
- Press “OK” to save.
Time program Pro3
- You can use time program Pro3 to specify up to 14 separate comfort phases which are repeated weekly. To configure a comfort phase in time program Pro3:
- In the configuration menu, use “+” and “–” to call up time program Pro3.
- Press the “OK” button.
The display shows “3—“.
- Press the “OK” button. A day of the week or a group of days is displayed.
- Use “+” and “–” to select the required day or group of days.
- Press the “OK” button. The start time for comfort mode is displayed.
- Use “+” and “–” to set the required start time.
- Press the “OK” button. The end time for comfort mode is displayed.
- Use “+” and “–” to set the required end time.
- ffPress the “OK” button.
- Comfort phase “3-01” has been configured.
- To configure a further comfort phase, use “+” and “–” in time program Pro3 to select display “3—“. Proceed as described above.
Note
To reset the selected comfort phases, activate parameter P4.
- Please note that activating parameter P4 resets all time programs (Pro1, Pro2, Pro3) to the factory setting.
Parameters
You can call up the following parameters
To change the value of a parameter, use “+” and “–” to call up the relevant parameter. Press the “OK” button. As soon as the “Editable parameter” symbol appears, you can change the parameter value with “+” and “–”. Press “OK” to save the selected value.
-
P1: Room temperature offset
Uneven temperature distribution in the room can result in a difference between displayed actual temperature I1 and the room temperature you measure yourself. To compensate for this difference, a room temperature offset of ±3 °C can be set via parameter P1. Example: The appliance indicates I1 = 21.0 °C. You have measured a room temperature of 20.0 °C. There is a difference of 1.0 °C.
To compensate for the difference, select an offset of P1 = -1.0. -
P2: Time format
Parameter P2 is used to specify whether to display the time in 12 hour or 24 hour format. -
P3: Temperature display units
Parameter P3 is used to specify whether the room temperature is displayed in degrees Centigrade [°C] or in degrees Fahrenheit [°F]. -
P4: Reset time programs
Activating parameter P4 resets all time programs to the factory setting. -
P5: Reset relative heating time
Activating parameter P5 resets the counter for relative heating time (I2)
Cleaning, care and maintenance
Cleaning, care and maintenance
The appliance contains no user-serviceable parts
Material losses
- Never spray cleaning spray into the air slot.
- Ensure that no moisture can enter the appliance.
- If a pale brownish discolouration appears on the appliance casing, wipe it off with a damp cloth.
- Clean the appliance when cold with ordinary cleaning products.
Avoid abrasive or corrosive cleaning products.
Note
- We recommend having the control components checked as part of regular maintenance.
- Have a qualified contractor check the safety and control components no more than 10 years after commissioning.
Troubleshooting
If you cannot remedy the fault, contact your qualified contractor. To facilitate and speed up your request, provide the number from the type plate (000000-0000-000000).
INSTALLATION
Safety
Only a qualified contractor should carry out installation, commissioning, maintenance and repair of the appliance.
General safety instructions
We guarantee trouble-free function and operational reliability only if original accessories and spare parts intended for the appliance are used.
CAUTION Burns
- Only mount the appliance on a vertical wall that is temperature-resistant to at least 85 °C.
- Maintain the minimum clearances to adjacent objects.
Material losses
- Never install the appliance directly below a wall socket.
- Ensure that the power cable is not in contact with any appliance components.
Instructions, standards and regulations
Note
Observe all applicable national and regional regulations and instructions.
Appliance description
Standard delivery
The following are delivered with the appliance:
- Wall mounting bracket (hooked into the appliance)
Installation
Minimum clearances
Installing the wall mounting bracket
The appliance is intended for wall mounting using the wall mounting bracket supplied. The appliance may only be installed horizontally.
Note
- The wall mounting bracket can be used as a template for wall mounting. This ensures sufficient clearance from the floor.
- Use a spirit level if the floor is uneven or sloping.
- Unhook the wall mounting bracket from the appliance.
- Place the centred wall mounting bracket horizontally on the floor. Mark holes 1 and 2.
- Lift up the wall mounting bracket so that its lower holes match up with the markings you have just made on the installation wall.
- Mark holes 3 and 4 on the installation wall.
- Drill the holes at the 4 markings.
- Secure the wall mounting bracket with suitable fixing materials (screws, rawl plugs). With the vertical slots, you can compensate for an offset fixing hole.
Appliance installation
Wall mounting bracket
- Hook the appliance onto the bottom tabs of the wall mounting bracket by the slots in the back of the appliance.
- Place the appliance in an upright position.
- Secure the appliance by pushing it towards the wall until it audibly snaps into place in the two upper springs on the wall mounting bracket.
Appliance
Locking screw
- Secure the appliance against unintentional release using the supplied locking screw on the left-hand side of the wall mounting bracket
Removing the appliance
- Undo and remove the locking screw from the wall mounting bracket.
- To release the appliance, push down the springs at the top of the wall mounting bracket.
- Tilt the appliance away from the wall and lift it off the bottom tabs on the wall mounting bracket.
Electrical connection
WARNING Electrocution
- Carry out all electrical connection and installation work in accordance with relevant regulations.
- In the case of a permanent connection, the appliance must be able to be separated from the power supply by an isolator that disconnects all poles with at least 3 mm contact separation.
- Do not install the appliance with a fixed power cable.
Note
- Observe the type plate. The specified voltage must match the mains voltage.
- Ensure the on-site supply cable has an adequate cross-section.
Note
In a non-domestic environment and in case of particularly high demands on the
appliance, such as permanent continuous operation, we recommend installing the
appliance as a permanent connection with a junction box. The appliance is
delivered with a power cable without a plug.
ffWhen wiring the appliance in permanently, connect the 4-core cable to a
connection socket as illustrated
- Neutral conductor = blue
- Live = brown
- Earth conductor = green/yellow
- Control cable = black
There are 3 possible ways to connect the appliance:
Appliance connection without control cable
Unregulated appliance. The control cable is not connected. In this case, insulate the control cable.
Temperature setback via control cable
- To reduce the temperature to the set setback temperature, the black control cable is activated via an external electronic contact (e.g. a time switch
Control cable connected to external control unit
The appliance can be connected to any control unit that issues the following waveforms as control signals.
Commissioning
The appliances is ready for operating as soon as it has been fixed to the installation wall and hard wired to the power supply.
- Remove the protective film from the programming unit.
Troubleshooting
The power cable must only be replaced (for example if damaged) by a qualified contractor authorised by the manufacturer, using an original spare part.
Appliance handover
Explain the functions of the appliance to the user. Draw special attention to the safety instructions. Hand over the operating and installation instructions to the user
Specification
Dimensions and connections
| | | CNS 50
Trend UK
| CNS 75
Trend UK
| CNS 100
Trend UK
| CNS 150
Trend UK
| CNS 200
Trend UK
| CNS 250
Trend UK
| CNS 300
Trend UK
---|---|---|---|---|---|---|---|---|---
a20 Appliance| Width| mm| 348| 426| 426| 582| 738| 894| 1050
b01 Entry electrical cables| | | | | | | | |
i13 Wall mounting bracket| Horizontal hole spacing| mm| 101| 179| 179| 335|
491| 647| 803
Data table
14.2 Data table|
---|---
| | CNS 50| CNS 75| CNS 100| CNS 150| CNS 200| CNS 250| CNS 300
| | Trend UK| Trend UK| Trend UK| Trend UK| Trend UK| Trend UK| Trend UK
| | 236559| 236560| 236561| 236562| 236563| 236564| 236565
Electrical data| | | | | | | |
Connected load| W| 500| 750| 1000| 1500| 2000| 2500| 3000
Power supply| | 1/N/PE ~ 240 V| 1/N/PE ~ 240 V| 1/N/PE ~ 240 V| 1/N/PE ~ 240
V| 1/N/PE ~ 240 V| 1/N/PE ~ 240 V| 1/N/PE ~ 240 V
Rated current| A| 2.1| 3.1| 4.2| 6.3| 8.3| 10.4| 12.5
Frequency| Hz| 50/-| 50/-| 50/-| 50/-| 50/-| 50/-| 50/-
Energy data| | | | | | | |
Room heating seasonal efficiency ηs| %| 39| 39| 39| 39| 39| 39| 39
Dimensions| | | | | | | |
Height| mm| 450| 450| 450| 450| 450| 450| 450
Width| mm| 348| 426| 426| 582| 738| 894| 1050
Depth| mm| 100| 100| 100| 100| 100| 100| 100
Weights| | | | | | | |
Weight| kg| 4.0| 4.6| 4.6| 6.0| 7.7| 9.2| 10.9
Versions| | | | | | | |
Frost protection setting| °C| 7| 7| 7| 7| 7| 7| 7
Version| | Wall mounted| Wall mounted| Wall mounted| Wall mounted| Wall
mounted| Wall mounted| Wall mounted
| | appliance| appliance| appliance| appliance| appliance| appliance|
appliance
IP rating| | IP24| IP24| IP24| IP24| IP24| IP24| IP24
Protection class| | I| I| I| I| I| I| I
Colour| | Alpine white| Alpine white| Alpine white| Alpine white| Alpine
white| Alpine white| Alpine white
Values| | | | | | | |
Setting range| °C| 5-30| 5-30| 5-30| 5-30| 5-30| 5-30| 5-30
Energy consumption data
The product data complies with EU regulations relating to the Directive on the ecodesign of energy related products (ErP). Product information on electric individual room heaters to regulation (EU) 2015/1188
| | CNS 50
Trend UK
| CNS 75
Trend UK
| CNS 100
Trend UK
| CNS 150
Trend UK
| CNS 200
Trend UK
| CNS 250
Trend UK
| CNS 300
Trend UK
---|---|---|---|---|---|---|---|---
| | 236559| 236560| 236561| 236562| 236563| 236564| 236565
Manufacturer| | STIEBEL| STIEBEL| STIEBEL| STIEBEL| STIEBEL| STIEBEL| STIEBEL
| | ELTRON| ELTRON| ELTRON| ELTRON| ELTRON| ELTRON| ELTRON
Heating output| | | | | | | |
Rated heating output Pnom| kW| 0.5| 0.8| 1.0| 1.5| 2.0| 2.5| 3.0
Minimum heating output (standard value) Pmin| kW| 0.0| 0.0| 0.0| 0.0| 0.0|
0.0| 0.0
Maximum continuous heating output Pmax,c| kW| 0.5| 0.8| 1.0| 1.5| 2.0| 2.5|
3.0
Auxiliary power consumption| | | | | | | |
At rated heating output elmax| kW| 0.000| 0.000| 0.000| 0.000| 0.000| 0.000|
0.000
At minimum heating output elmin| kW| 0.000| 0.000| 0.000| 0.000| 0.000| 0.000|
0.000
In standby elSB| kW| 0.000| 0.000| 0.000| 0.000| 0.000| 0.000| 0.000
Type of heating output/room temperature control| | | | | | | |
Single stage heating output, no room temperature control| | –| –| –| –| –| –|
–
Two or more manually selectable stages, no room temperature control| | –| –|
–| –| –| –| –
Room temperature control with mechanical thermostat| | –| –| –| –| –| –| –
With electronic room temperature control| | –| –| –| –| –| –| –
Electronic room temperature control and time of day control| | –| –| –| –| –|
–| –
Electronic room temperature control and day of week control| | x| x| x| x| x|
x| x
Other control options| | | | | | | |
Room temperature control with presence detection| | –| –| –| –| –| –| –
Room temperature control with window open detection| | x| x| x| x| x| x| x
With remote control option| | –| –| –| –| –| –| –
With adaptive control of heating start| | x| x| x| x| x| x| x
With operating time limitation| | –| –| –| –| –| –| –
With black bulb sensor| | –| –| –| –| –| –| –
Guarantee
The guarantee conditions of our German companies do not apply to appliances acquired outside of Germany. In countries where our subsidiaries sell our products a guarantee can only be issued by those subsidiaries. Such guarantee is only granted if the subsidiary has issued its own terms of guarantee. No other guarantee will be granted. We shall not provide any guarantee for appliances acquired in countries where we have no subsidiary to sell our products. This will not affect warranties issued by any importers.
Environment and recycling
We would ask you to help protect the environment. After use, dispose of the various materials in accordance with national regulations
Deutschland
- STIEBEL ELTRON GmbH & Co. KG
- Dr.-Stiebel-Straße 33 |
- 37603 Holzminden
- Tel. 05531 702-0 |
- Fax 05531 702-480
- info@stiebel-eltron.de
- www.stiebel-eltron.de
Verkauf
- Tel. 05531 702-110 |
- Fax 05531 702-95108 |
- info-center@stiebel-eltron.de
Kundendienst
- Tel. 05531 702-111 |
- Fax 05531 702-95890 |
- kundendienst@stiebel-eltron.de
Ersatzteilverkauf
- Tel. 05531 702-120 |
- Fax 05531 702-95335 |
- ersatzteile@stiebel-eltron.de
Australia
- STIEBEL ELTRON Australia P ty. L td.
- 294 Salmon Street | Port Melbourne VIC 3207
- Tel. 03 9645-1833 | Fax 03 9644-5091
- info@stiebel-eltron.com.au
- www.stiebel-eltron.com.au
Austria
- STIEBEL ELTRON Ges.m.b.H.
- Gewerbegebiet Neubau-Nord
- Margaritenstraße 4 A | 4 063 Hörsching
- Tel. 07221 74600-0 | Fax 07221 74600-42
- info@stiebel-eltron.at
- www.stiebel-eltron.at
Belgium
- STIEBEL ELTRON bvba/sprl
- ‘t Hofveld 6 – D 1 | 1702 Groot-Bijgaarden
- Tel. 02 42322-22 | Fax 02 42322-12
- info@stiebel-eltron.be
- www.stiebel-eltron.be
China
- STIEBEL ELTRON (Tianjin) Electric Appliance Co., L td.
- Plant C3, XEDA International Industry City
- Xiqing Economic Development Area
- 300085 T ianjin
- Tel. 022 8396 2077 | Fax 022 8396 2075
- info@stiebeleltron.cn
- www.stiebeleltron.cn
Czech Republic
- STIEBEL ELTRON spol. s r.o.
- Dopraváků 749/3 | 1 84 00 Praha 8
- Tel. 251116-111 | Fax 235512-122
- info@stiebel-eltron.cz
- www.stiebel-eltron.cz
Finland
- STIEBEL ELTRON OY
- Kapinakuja 1 | 0 4600 Mäntsälä
- Tel. 020 720-9988
- info@stiebel-eltron.fi
- www.stiebel-eltron.f
United States of America
- STIEBEL ELTRON, Inc.
- 17 West Street | 01088 West Hatfield MA
- Tel. 0413 247-3380 | Fax 0413 247-3369
- info@stiebel-eltron-usa.com
- www.stiebel-eltron-usa.com
References
Read User Manual Online (PDF format)