California Faucets VL-R Vessel Wall Mount Faucet Rough in Valve Instruction Manual

June 17, 2024
California Faucets

California-Faucets-LOGO

California Faucets VL-R Vessel Wall Mount Faucet Rough in Valve

California-Faucets-VL-R-Vessel-Wall-Mount-Faucet-Rough-in-Valve-
PRODUCT

Specifications

  • Product Name: VL-R Vessel Rough Valve
  • Recommended Supply Pressure: 20 to 70 psi
  • Operating Pressure Difference between Hot and Cold Supplies: Not more than 30 psi
  • Installation: Should be done by a licensed professional

FAQ

  • Q: What should I do if the water pressure exceeds 70 psi?
  • A: If the water pressure exceeds 70 psi, you should install a pressure-educing valve (PRV) to regulate the pressure.
  • Q: How far should soldering of fittings be done from the valve?
  • A: All soldering of fittings should be performed a minimum of 4 inches away from the valve.
  • Q: What is the minimum setback requirement for the valve rough from the finished wall surface?
  • A: The valve rough must be set back a minimum of 2-5/8 inches from the finished wall surface to the centre of inlets.

CALIFORNIA FAUCETS RECOMMENDS THAT ALL PLUMBING PRODUCTS BE INSTALLED BY A LICENSED PROFESSIONAL

IMPORTANT: Read all instructions before installation and provide a copy of instructions to the consumer.
Operating Specifications

  • Recommended Supply Pressure: 20 to 70 psi *†
  • Operating pressures between hot and cold supplies should vary no more than 30 psi.
  • If water pressure exceeds 70 psi, install a pressure-educing valve (PRV).

INSTALLING VALVE

  • Install BRACING (2) (2×4 stud recommended) at desired height and depth
    IMPORTANT: Refer to the table in for desired depth depending on trim series dimensions, “A” and “B”

  • Secure VALVE (1) to BRACING (2) using SCREW (3) (not supplied)

SUPPLY CONNECTIONS

  • Connect the cold supply to COLD INLET (1a) and connect the hot supply to HOT INLET (1b)

NOTE: Use thread sealant (not supplied) on all threaded connections
IMPORTANT: Flush supply lines before installation to prevent damage and malfunction of cartridge
WARNING: All soldering of fittings shall be performed a minimum of 4” away from VALVE (1)

  • To check for leaks, install ½” NPT PLUG (4) (not supplied) into SPOUT OUTLET (1c)
  • Turn on the water supply valve
  • Remove MUDGUARDS (5)
  • To “open” the valve, turn STEM (1d) counterclockwise (CCW) for cold supply and STEM (1e) clockwise (CW) for hot supply
  • Check all connections for leaks
  • Give these instructions to consumers for safekeeping

California-Faucets-VL-R-Vessel-Wall-Mount-Faucet-Rough-in-Valve-
FIG-2

RE-ALIGNING CARTRIDGE

IMPORTANT: Shut off the water supply before starting.

  • Slightly loosen in a CCW direction the cartridge NUT (6). Place HANDLE (8) on STEM (7) and tighten in a CW direction until the desired alignment of the handle is achieved. Retighten cartridge NUT (6) to factory torque setting of 14 ft-lbs

WARNING: Cartridge NUT (6) must be properly torqued to prevent possible failure and/or water damage.

DIMENSIONS

NOTE: When fitting the handle it may be necessary to shorten Stem and/or All Thread to eliminate the gap between the handle & escutcheon.

  • “A” = Stem overall length for Finished Wall
  • “B” = All Thread overall length from Finished Wall

Handle Series #| “A”

Minimum

| “B”

Minimum

---|---|---
30, 30X| 1-3/4”| 7/8”
33| 2-1/2”| 1-1/2”
34| 2-7/16”| 1-1/2”
35| 2-1/2”| 1-1/2”
37, 37X| 13/16”| 5/16”
38, 38X| 13/16”| 5/16”
39| 1-3/16”| 5/16”
45, 45X| 2”| 1-1/8”
46| 2-5/16”| 1-1/2”
47| 2-5/16”| 1-1/2”
48, 48X| 2-3/8”| 1-5/8”
52| 1-3/8”| 1-1/8”
53| 1-3/8”| 1-1/8”
55| 2-5/16”| 1-5/8”
60| 2-1/4”| 1-1/2”
61, 61X,

61XD

| 2-1/4”| 1-1/2”
62| 1-1/16”| 1/4”
64| 2-1/2”| 1-3/4”
65| 1-15/16”| 1-1/4”
66| 1-15/16”| 1-1/4”
70| 1-3/8”| 3/4”
74| 3/4”| 0”
77, 77R| 1-5/16”| 5/8”
78, 78R| 1-5/16”| 5/8”
80, 80W| 1-9/16”| 7/8”
85, 85B,

85W

| 1-1/2”| 3/4”
C1, C1X, C1XS| 1-3/8”| 5/8”
C2, C2B| 1-3/8”| 3/8”
E3| 1-1/4”| 1/4”
E4| 13/16”| 1/4”
E5| 7/8”| 1/4”

Side View

California-Faucets-VL-R-Vessel-Wall-Mount-Faucet-Rough-in-Valve-
FIG-5

Front View

California-Faucets-VL-R-Vessel-Wall-Mount-Faucet-Rough-in-Valve-
FIG-6

NOTE: Valve rough must be set back a minimum of 2-5/8” from the finished wall surface to the centre of inlets.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>