ARCO RV-C Zeus High Energy Alternator Regulator Installation Guide
- June 17, 2024
- Arco
Table of Contents
RV-C Zeus High Energy Alternator Regulator
High Energy
Alternator Regulator
RV-C Integration Guide
Physical connection
Using a standard Cat5/6 Ethernet cable, connect Zeus (via CANBUS port) to Cerbo (via VE.Can port).
Zeus configiuration
-
In the ARCO App, connect to your Zeus and click ‘View Device.’
-
Select ‘Live Details.’
-
Select ‘Settings.’
-
Select the ‘Regulator’ tab.
-
Scroll down until you see ‘Sync Mode’ and click on the text, then select ‘Lithionics Follower.
-
With ‘Lithionics Follower’ mode selected, save your changes.
Zeus is now configured!
Cerbo GX Configuration
- Under ‘Settings’ select ‘Services.’
- Select ‘VE.CAN port.’
- For the ‘CAN-bus profile’ select the option for ‘VE. CAN 7& Lynx Ion BMS(250kbit)s.’
The Cerbo is now configured!
Network diagram
AR CO Zeus
R V-C Integration Guide
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>