Specifications

  • Operating Voltage: 12VDC
  • Card Type : ID card or IC card
  • Lock Output Load : Max. 1.5A
  • Door Open Time : 0-99 seconds
  • Card Capacity : 2000
  • Card Reading Distance : Max. 2-23/64 inches
  • PIN Capacity: 500
  • Product Weight: 1.01lb
  • Idle Current : 50mA
  • Enclosure Material : Zinc Alloy
  • Waterproof Level : IP66
  • Operating Humidity : 10%-90%RH
  • Dimensions: 4-7/8 x 2-33/64 x 1-9/32 inches
  • Wiring Connections: Electric Lock, Exit Button, Bell

Installation

  1. Paste the installation drawing at the desired location (recommended height: 1.4-1.5m from the ground).
  2. Punch holes according to the diagram.
  3. Insert plastic anchors into the holes.
  4. Mount the keypad using the provided mounting hardware.
  5. Secure the keypad with the screws.

Wiring Terminal Connections

DKC Terminal Wiring Reference

  • +12V – Positive DC supply lead (Red wire)
  • GND – Ground (Black wire)
  • PUSH – Opening signal outputs for connected to Exit Button (Yellow wire)
  • BELL – Control Signal outputs for connecting to a Special Power Supply (Purple wire)
  • NO, COM, NC – Wiegand data zero and one connections
  • BELL – External doorbell connections
  • LED/BEEP – Green light and sound input for Wiegand Mode (Pink, Grey, Brown, Green, White, Blue, Light Blue wires)

FAQ

  • Q: How do I change the keypad from DKC to Wiegand mode?
    • A : Instructions on changing to Wiegand mode can be found in the manual under the ‘Changing to Wiegand Mode’ section.

Packing List

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig1

Introduction

The HBK-A03 Digital Keypads by HOBK offer the Digital Keypad Controller (DKC) or Wiegand output for universal compatibility with access control systems. The outdoor-rated 12 key plastic 2’x6′ keypad features silicone rubber keys. HBK-A03 keypads are shipped in ‘DKC’ from the factory. When interfacing with the Wiegand, please change the keypad to ‘Wiegand Mode’. Instructions on how to change from DKC to Wiegand mode are found in the Changing to WiegandMode section below.

Features

  • Full programming from the keypad.
  • Supports Card, PIN, Card + PIN, Card or PIN.
  • Can be used as a standalone keypad.
  • Adjustable door open time.
  • Very low power consumption.
  • Backlit keys.
  • Lock output current short circuit protection.
  • With bell function, supports external bell.
  • Audible keystroke echo.
  • Red, blue, white, yellow and green LED indicators display the working status.
  • Wiegand 26 input for connection to the external reader or Wiegand 26 output for connection to a controller.

Specifications

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig2

Dimensions

Installation

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig4

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig5

  • Remove the back cover from the keypad
  • Drill 4 holes on the wall for the self-tapping screws and 1 hole for the cable
  • Put the supplied plastic anchors into the 4 holes
  • Fix the back cover firmly on the wall with 4 self-tapping screws
  • Thread the cable through the cable hole
  • Attach the keypad to the back cover

Packaging Details

After opening the package, please make sure the device is in good condition and confirm below accessories are complete or not.

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig6

Wiring Terminal Connections

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig7

Wiring diagram for operating as a Wiegand Output Reader

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig8

In this mode the device supports Wiegand 26 bit output.

Common Power Supply Diagram

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig9

Special Power Supply Diagram

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig10

Sound and Light Indication

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig11

Operation Guide

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig12

Basic Operation

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig13

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig14

System Setting

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig15

To Unlock the lock

UHPPOTE-HBK-RFID-Door-Access-Control-Keypad-Card-Reader-
fig16

Keypad Operation

HBK-A03 are shipped in ‘DKC’ from the factory. When interfacing with the Wiegand, please change the keypad to ‘Wiegand Mode’. Instructions on how to change from DKC to Wiegand mode are found below.

Changing to Wiegand Mode

  1. Enter the programming mode (See above ‘Operation Guide’ ).
  2. Press the ’82 #’ keys followed by pressing the ‘*’ key.

Changing to Character Mode

  1. Remove power from the HBK-A03.
  2. Apply power to the HBK-A03.
  3. Press the ’99 #’ keys within 10 seconds.

FCC Warning

FCC ID: 2A4H6HBK-A01

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help. To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with a minimum distance between 20cm of the radiator and your body: Use only the supplied antenna.

2023 HOBK Electronic Technology Co., Ltd All rights reserved