sumup REG001 SOLO Card Reader User Manual
- June 17, 2024
- sumup
Table of Contents
**sumup REG001 SOLO Card Reader User Manual
**
Important safety information
- Read all the safety information below before using your device.
- This device’s operating temperature range is 0°C~40 °C.
- Using this device in the environments outside of this temperature range may damage the device.
- Power this device only with the included or authorised cable and power adapter. Using other adapters may cause fre, electric shock, and damage the device and the adapter.
- The device must be recycled or disposed of separately from household waste. Mishandling the device may cause fre or explosion.
- Dispose of or recycle the device and its accessories according to the local regulations.
- Keep your device dry.
- Do not try to repair the device yourself. If any part of the device does not work properly, contact SumUp customer service.
Safety precautions
-
Observe any law and rule which restricts using radio devices in specifc cases and environments.
-
Obey all posted signs to turn of radio devices. Turn of your wireless device when in areas posted to turn of “two-way radios” or “electronic devices”.
-
Comply with the current rules and regulations of hospitals and health centres. Please consult your doctor and the device manufacturer to determine if operation of your device may interfere with the operation of your medical device. To avoid potential interference with the pacemaker, maintain a separation of 15cm between the device and the pacemaker.
Do not use your device near hearing aids, cochlear implants, etc., to avoid interference with medical equipment. -
To avoid lightning strikes, do not use your device outdoors during thunderstorms.
-
Do not use your device in places with high humidity such as bathrooms. Doing so may result in electric shock, injury, fre, and charger damage.
-
Do not use your device in petrol stations and explosive atmospheres and potentially explosive environments include fuelling areas, below decks on boats, fuel or chemical transfer or storage facilities, areas where the air contains chemicals or particles, such as grain, dust, or metal powders.
EU regulations
Hereby, SumUp declares that this device is in compliance with the essential
requirements and other relevant provisions of the RE Directive 2014/53/EU &
RoHS directive 2011/65/EU.
The full text of declaration of conformity could be consulted at
www.sumup.ie/legal.
GB and NI Regulations
Hereby, SumUp declares that this device is in compliance with the essential requirements and other relevant provisions of Statutory Instrument SI 2017 No. 1206 (Radio Equipment) and SI 2012 No. 3032 (RoHS). For a copy of the full text of the UKCA Declaration of Conformity please access the following URL https://sumup.co.uk/legal.
For CE and UKCA marking; EU and UK Declaration of Conformity contact cemarking@sumup.com.
Frequency bands and power
This device of ers the following frequency bands in EU areas only and maximum radio-frequency power:
| Frequency band| Max conducted power (EIRP)
---|---|---
Bluetooth| 2402-2480MHz| 5 dBm
Bluetooth (LE)| 2402-2480MHz| 6 dBm
WLAN 802.11b| 2412-2472MHz| 19.5 dBm
WLAN 802.11g| 2412-2472MHz| 17.5 dBm
WLAN 802.11n| 2412-2472MHz| 17.5 dBm
WLAN 802.11a| 5180-5825MHz| 16.5 dBm
WLAN 802.11n (HT 20MHz)| 5180 – 5825MHz| 15.5 dBm
WLAN 802.11n (HT 40MHz| 5180 – 5825MHz| 14.5 dBm
WLAN 802.11ac (HT 40MHz)| 5190 – 5795MHz| 12.5 dBm
WLAN 802.11ac (HT 80MHz)| 5210 – 5775MHz| 12.5 dBm
Power Rating
Model: CXX012WT2E.00
Input: 100-240V ~ 50-60Hz 2.0A
Output: +5.0V–3.0A (15.0W)
+9.0V–3.0A (27.0W)
+12.0V–3.0A (36.0W)
+15.0V–3.0A (45.0W)
+20.0V–3.25A (65.0W)
PPS: 3.3-11.0V–5.0A
PPS: 3.3-21.0V–3.1A
FCC regulations
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules.
FOR MOBILE DEVICE USAGE ( >20cm/low power)
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
FCC ID: 2A39U-REG001
SumUp Ltd.
BLK 8 Harcourt Centre Charlotte Way, Dublin D02 K580, IE
SumUp Payments Ltd.
16 Shorts Garden, London WC2H 9US, UK
SumUp Inc.
1209 Orange St Wilmington DE 19801-0801
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>