Goodman R410A Inverter Wall Mounted Heat Pump Instruction Manual

June 17, 2024
Goodman

PCXGRUS2232
R410A Inverter
Wall Mounted
HeatpumpGoodman R410A Inverter Wall Mounted Heat
Pump FTXNG-A Series

Product Line-up for R410A Inverter

Class 09 12
Indoor
Outdoor

Wall Mounted Heatpump

Goodman R410A Inverter Wall Mounted Heat Pump - Wall Mounted
Heatpump

FTXNG-A Series

Indoor Unit Goodman R410A Inverter Wall Mounted Heat Pump - Indoor
Unit.

Wireless Handset

Heatpump (BRC52B67)Goodman R410A Inverter Wall Mounted Heat Pump -
Heatpump

What is Inverter  technology?
Inverter system ensures faster cooling with significant energy saving. Moreover, it helps to maintain consistent temperature in the room, makes you feel comfortable all the time especially when you are sleeping.

Swing Compressor
Thanks to its smooth rotation, the swing compressor decreases friction and vibration. It also prevents the leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation.

The swing compressor can reduce operational vibration and sound because its piston moves smoothly inside the compressor.

DC Inverter
DC Inverter models are equipped with the Reluctance DC motor for compressors. The Reluctance DC motor uses 2 different types of torque, neodymium magnet¹ and reluctance torque².This motor saves energy by generating more power with a smaller electric current than AC or conventional DC motors. It is more efficient at the low frequencies most commonly used by air conditioners³

Neodymium magnets are used in the pink-coloured area.

  1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.
  2. The torque created by the change in power between the iron and magnet parts.
  3. The frequency range used by air conditioners during periods of stable operation.

This is the range in which air conditioners operate for the longest periods.

Advantages of Inverter technology

  • Superior comfort
  • Higher efficiency
  • Powerful operation
  • Better energy savings

Fixed speed (non-inverter) systems operate by compressor start-stop  cycles which consumes more energy and have higher variance of the room temperature.Goodman R410A Inverter Wall Mounted Heat Pump - Inverter
technology

Flexible performance, rapid response time
After quickly reaching set temperature, the inverter system constantly adjusts and fine-tunes the cooling capacity to prevent undesired temperature swings. Room comfort level is constantly maintained even when the number of people in the room increases or decreases.Goodman R410A Inverter Wall
Mounted Heat Pump - response time

Flexible Installation
The extended piping length promotes flexible installation

Model| Pre-charge
Length, ft (m)| Max. Piping
Length, ft (m)| Max. Piping
Elevation, ft(m)
---|---|---|---
FTXNG09AXVJU RXNG09AXVJU| 32-13/16 (10)| 65-5/8 (20)| 32-13/16 (10)
FTXNG12AXVJU RXNG12AXVJU| 32-13/16 (10)| 65-5/8 (20)| 32-13/16 (10)
FTXNG18AXVJU RXNG18AXVJU| 32-13/16 (10)| 98-1/2 (30)| 32-13/16 (10)

Note:
Additional refrigerant is required if the piping is longer than the pre-charge length.
For details, kindly refer to the installation manual.

Lifestyle Convenience

Powerful operation
Once activated, this feature will engage the indoor fan motor to run at maximum speed for 20 minutes. The turbo airflow enables the desired temperature to be achieved faster, especially in larger spaces.

ECO+
An intelligent feature that ensures optimum energy consumption while fulfilling basic human comfort needs.
Once activated, set temperature will be adjusted automatically to an eco- friendly level while limiting the maximum power consumption.

Goodman R410A Inverter Wall Mounted Heat Pump - ECO+

More time is required to reach set temperature after activating ECO+ mode.

Sleep mode
Pressing the Sleep button activates the Sleep Mode. This function prevents excessive cooling/heating for a pleasant sleep.

Goodman R410A Inverter Wall Mounted Heat Pump - Sleep
mode

Cooling operation:

  1. After 60 minutes, room temperature is raised by 0.5ºC.
  2. After 120 minutes, room temperature is raised by another 0.5ºC.

Heating operation:

  1. After 60 minutes, room temperature is reduced by 1 ºC.
  2. After 120 minutes, room temperature is reduced by another 1 ºC.

Goodman R410A Inverter Wall Mounted Heat Pump - sleeping
environment

Auto adjustment of LED display intensity provide user a sleeping environment with minimum disturbance.

Cleanliness

Catechin Filter
This filter is infused with catechin extracted from green tea. This substance deactivate bacteria and virus captured on the filter surface. On top of that, this substance stop any mildew grow on the filter surface.

Goodman R410A Inverter Wall Mounted Heat Pump - Catechin
Filter

Titanium Apatite Deodorizing Filter
Titanium apatite filter is a filter with advanced adsorption power and effectively deodorizing odours. The filter delivers consistent performance for approximately 3 years if washing with water is performed once every 6 months.

Function List

Series
FunctionsGoodman R410A Inverter Wall Mounted Heat Pump -
Functions

Note:  ●: Available
– : Not Available

FTXNG-A FTXNG-A
09/12 18

Product Features

Lifestyle Convenience

| Indoor Unit On/Off Switch
The unit can be conveniently started by hand if the wireless remote controller is misplaced or its batteries are not charged.
---|---
| Wireless Remote Controller with Luminous Button
The luminous button absorbs and saves light and then slowly releases it. This makes it easy to see in the dark.
| Inverter Powerful Operation
This function boosts cooling or heating performance for a 20 minutes period. It is convenient when it is necessary to change the room temperature quickly.
| ECO+ Function
An intelligent feature that ensures optimum energy consumption while fulfilling basic human comfort needs. Once activated, set temperature will be adjusted automatically to an eco-friendly level while limiting the maximum power consumption.
| Sleep Mode
Unwind at the end of the day with Sleep Mode, which gradually adjust set temperature according to regular sleeping temperature patterns and auto adjust the LED display intensity for an effortlessly personalised sleeping environment.
| Wireless Remote Controller with Backlight
The backlit LCD allows easy operation in the dark, convenient for users to identify the functions activated.
| LED Display On/Off
The LED Display on unit can be conveniently turned off with the touch of a single button to ensure zero light disturbance.

Worry-Free

| Auto-Restart after Power Failure
The air conditioner memorises the settings for operation mode, fan speed and temperature setting and automatically returns to them when power is restored after a power failure.
---|---
| Self-Diagnosis with Digital Display
Malfunction codes can be retrieved and shown on the digital display panel of the wireless remote controller for fast and easy maintenance.

Comfort Airflow

| Power-Airflow Flap
The Power-Airflow Flap flattens out during cooling operation to deliver cool air to the corners of a room.
---|---
| Power-Airflow Dual Flap
The Power-Airflow Dual Flaps can flatten out during cooling operation to deliver cool air to the corners of a room.
| Wide-Angle Louvers
The Wide-Angle Louvers provide wide airflow coverage for effective operation no matter where the indoor unit is placed in a room.
| Vertical Auto-Swing (up and down)
This function automatically moves the flaps up and down to distribute air across a room.

Comfort Control

| Auto Fan Speed
The microprocessor automatically adjusts the fan speed to high to rapidly reach the set temperature. Once the temperature is achieved, this function reduces the fan speed to low.
---|---
| Indoor Unit Quiet Operation
Indoor unit operating sound pressure levels are decreased from the Low setting fan speed using the wireless remote controller.
| Programme Dry Function
The computer chip works to rid the room of humidity while keeping the room temperature as stable as possible. It controls the temperature and airflow rate automatically, so manual adjustment of these functions is not available.
| Automatic Operation
This function automatically selects cooling or heating operation mode based on the room temperature at startup.

Timer
24 Hour On/Off Timer

Cleanliness

| Titanium Apatite Deodorising Filter
This filter contains titanium apatite. While the filter’s micron-level fibres trap dust, the titanium apatite adsorbs odours and allergens, as well as deodorises odours. The filter can be used for up to three years with proper maintenance.
---|---
| Catechin Air Filter
This filter is infused with catechin extracted from green tea. This substance deactivate bacteria and virus captured on the filter surface. On top of that, this substance stop any mildew grow on the filter surface.
| Wipe-Clean Flat Panel
The flat panel design can be cleaned with only the single pass of a cloth across its smooth surface. The flat panel can also be easily removed for more thorough cleaning.
| Removable Drain Pan
The drain pan collects condensation from the indoor heat exchanger fins. Removable drain pans help to reduce the cleaning time and ensure a better serviceability.

Specifications

Goodman R410A Inverter Wall Mounted Heat Pump -
Specifications

Heatpump

Class 09 12 18
Model Name Indoor FTXNG09AXVJU FTXNG12AXVJU
Outdoor RXNG09AXVJU RXNG12AXVJU RXNG18AXVJU
Rated Cooling Capacity (Min ~ Max) Btu/hr 8,800 (4,400 – 10,200) 11,000
(4,400 – 13,300) 18,000 (6,700 – 20,000)
kW 2.57 (1.30 – 3.00) 3.22 (1.30 – 3.90) 5.27 (1.96 – 5.86)
Rated Heating Capacity (Min ~ Max) Btu/hr 9,400 (4,400 – 13,000) 11,300
(4,400 – 16,400) 17,900 (5,800 – 22,500)
kW 2.75 (1.30 – 3.80) 3.31 (1.30 – 4.81) 5.24 (1.70 – 6.60)
Rated Power Input Cooling W 800
Heating W 774 1004
Rated EER2 Btu/hr/W 11.0 8.5
W/W 3.22 2.49 3.08
Rated COP Btu/hr/W 12.15 11.26
W/W 3.56 3.30 3.30
SEER 18.0 18.0 18.0
HSPF 9.0 9.0 8.5
Power Supply (V/pH/Hz) 208/230/1/60
Maximum Piping Length ft (m) 65-5/8 (20) 65-5/8 (20)
Maximum Piping Elevation ft (m) 32-13/16 (10) 32-13/16 (10)
Chargeless ft (m) 32-13/16 (10) 32-13/16 (10)
Piping Connections Liquid inch (mm) 1/4 (6.4)
Gas inch (mm) 3/8 (9.5) 3/8 (9.5)
Operating range – Cooling ˚F (˚C) 50 – 114.8 (10 – 46) 50 – 114.8 (10 –
46) 50 – 114.8 (10 – 46)
Operating range – Heating ˚F (˚C) 5 – 64.4 (-15 – 18) 5 – 64.4 (-15 – 18)

5 – 64.4 (-15 – 18)
Operating range – Ambient Cooling| ˚F (˚C)| 5 – 114.8 (-15 – 46)| 5 – 114.8 (-15 – 46)| 5 – 114.8 (-15 – 46)
Indoor Unit
Unit Dimension| H| inch (mm)| 11-1/3 (288)| 11-1/3 (288)| 11-11/16 (297)
W| inch (mm)| 30-5/16 (770)| 30-5/16 (770)| 39-9/16 (990)
D| inch (mm)| 9-3/16 (234)| 9-3/16 (234)| 10-3/4 (273)
Sound Pressure Level (T/H/M/L/SL)| Cooling| dBA| 45/43/36/29/19| 48/45/37/31/19| 50/48/43/37/33
Heating| 45/42/35/29/25| 47/43/36/30/26| 49/46/41/36/33
Airflow (T/H/M/L/SL)| Cooling| CFM| 466/431/322/249/142| 473/436/316/247/132| 754/716/605/467/395
Heating| 466/402/322/249/219| 473/412/316/247/210| 754/716/605/467/395
Unit weight| lbs (kg)| 20.3 (9.2)| 21.4 (9.7)| 31 (14)
Outdoor Unit
Unit Dimension| H| inch (mm)| 21-11/16 (550)| 21-11/16 (550)| 27-13/32 (696)
W| inch (mm)| 26-1/2 (675)| 26-1/2 (675)| 36-5/8 (930)
D| inch (mm)| 11-3/16 (284)| 11-3/16 (284)| 13-13/16 (351)
Sound
Pressure Level (H)| Cooling| dBA| 46| 48| 53
Heating| 48| 48| 53
Unit weight| lbs (kg)| 55 (25)| 62 (28)| 97 (44)

Remarks:

  1. Due to product innovation, all specifications are subjected to change by the manufacturer without prior notice.
  2. All units are being tested according to AHRI 210/240 Standard.
  3. Nominal cooling capacity are based on the conditions: 80˚F (26.7˚C) DB / 67˚F (19.4˚C) WB indoor and 95˚F (35˚C) DB outdoor.
  4. Nominal heating capacity are based on the conditions: 70˚F (21.1˚C) DB indoor and 47˚F (8.3˚C) DB / 43˚F (6.1˚C) WB outdoor.

NOTES ———

DAIKIN MALAYSIA SDN.BHD.
Lot 60334, Persiaran Bukit Rahman Putra 3,
Taman Perindustrian Bukit Rahman Putra,
47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia.
www.daikinmalaysia.com

DAIKIN INDUSTRIES, LTD.
Head office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-Ku, Osaka, 530-8323 Japan.
*Specifications, designs and other content appearing in this brochure are current as of July 2020 but subject to change without prior notice.

Authorised Dealer:

© All rights reserved

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals