Fujitsu ABY125-KR Air Conditioner

June 17, 2024
FUJITSU

Fujitsu ABY125-KR Air Conditioner

Fujitsu-ABY125-KR-Air-Conditioner-fig-1

Product Information

Specifications

  • Model: Ceiling Type Air Conditioner
  • Part No.: 9384329004
  • Original Instructions

Safety Precautions
To prevent personal injury or property damage, read this section carefully before you use this product, and be sure to comply with the following safety precautions. Incorrect operation due to failure to follow the instructions may cause harm or damage.

  • WARNING: This mark warns of death or serious injury.
  • CAUTION: This mark warns of injury or damage to property.

Operating Manual Symbols

  • WARNING: This symbol shows that this product uses a flammable refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire.
  • CAUTION: This symbol shows that the operating manual should be read carefully.
  • CAUTION: This symbol shows that a servicepersonnel should be handling this equipment with reference to the installation manual.

Product Usage Instructions

Name of Parts
Refer to the manual for a detailed description of each part.

Basic Operations
Follow the instructions in the manual for basic operations of the air conditioner.

Airflow Settings
Adjust the airflow settings as per your comfort level.

Cleaning and Care
Regularly clean and maintain the air conditioner as per the guidelines provided in the manual to ensure optimal performance.

Troubleshooting
Refer to the troubleshooting section in the manual for guidance on resolving common issues.

FAQ

  • How often should I clean the air conditioner?
    It is recommended to clean the air conditioner at least once every month to maintain efficiency.

  • Can I install the air conditioner myself?
    For safety reasons and warranty purposes, it is advised to have a professional install the air conditioner following the installation manual guidelines.

SAFETY PRECAUTIONS

To prevent personal injury or property damage, read this section carefully before you use this product, and be sure to comply with the following safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classified as follows:

  • WARNING
    This mark warns of death or serious injury.

  • CAUTION
    This mark warns of injury or damage to property.

    • This mark denotes an action that is PROHIBITED.
    • This mark denotes an action that is COMPULSORY.

Explanation of symbols displayed on the indoor unit or outdoor unit.

  • WARNING
    This symbol shows that this product uses a flammable refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire.

  • CAUTION
    This symbol shows that the operating manual should be read carefully.

  • CAUTION
    This symbol shows that a service personnel should be handling this equipment with reference to the installation manual.

  • CAUTION
    This symbol shows that information is available such as the operating manual or installation manual.

WARNING

  • The appliance shall be installed, operated and stored in a room with a floor area larger than X m².
    • M ≤ 1.22
    • 1.22 < M ≤ 1.23 1.45
    • 1.23 < M ≤ 1.50 2.15
    • 1.50 < M ≤ 1.75 2.92
    • 1.75 < M ≤ 2.0 3.82
    • 2.0 < M ≤ 2.5 5.96
    • 2.5 < M ≤ 3.0 8.59
    • 3.0 < M ≤ 3.5 11.68
    • 3.5 < M ≤ 4.0 15.26
  • This product contains no user-serviceable parts. Always consult authorized service personnel for repairing, installation, and relocation of this product. Improper installation or handling will cause leakage, electric shock, or fire.
  • In the event of a malfunction such as burning smell, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult authorized service personnel.
  • Take care not to damage the power supply cable. If it is damaged, it should be replaced only by the authorized service personnel in order to avoid a hazard.
  • In the event of refrigerant leakage, be sure to keep away from fire or any flammables, and consult authorized service personnel.
  • In the event of a thunder storm or any prior sign of a lightning strike, turn off the air conditioner via the remote controller, and refrain from touching the product or the power source to prevent any electrical hazards.
  • This product shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • This product shall be stored in a well-ventilated area.
  • Be aware that refrigerants may not contain an odour.
  • This product shall be stored so as to prevent mechanical damage from occurring.
  • Disposing of the product shall be done properly, in compliance with national or regional regulations.

WARNING

  • This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of this product by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with this product.
  • Do not install the unit in area filled with mineral oil such as a factory or area containing a large amount of splashed oil or steam such as a kitchen.
  • Do not start or stop the operation of this product by inserting or pulling out the power plug, or by turning on or off the circuit breaker.
  • Do not use flammable gases near this product.
  • Do not expose yourself directly to the cooling airflow for many hours.
  • Do not insert your fingers or any other objects into outlet port or inlet grille.
  • Do not operate with wet hands.
  • Do not use means to accelerate the defrosting process or to clean this product, other than those recommended by the manufacturer.
  • Do not pierce or burn.

CAUTION

  • Provide occasional ventilation during use.
  • Always operate this product with air filters installed.
  • Ensure that any electronic equipment is at least 1 m (40 in) away from this product.
  • Disconnect all the power supply when not using this product for extended periods.
  • After a long period of use, ensure to get the mounting of the indoor unit checked to prevent this product from falling down.
  • The airflow direction and the room temperature should be carefully considered when you use this product in a room with infants, children, elderly or sick persons
  • Keep the surroundings of the outdoor unit clean and tidy, and do not place items around it. Any objects blocking or entering from the outlet ports may cause product malfunction.
  • Do not direct the airflow at fireplaces or heating apparatus.
  • Do not block or cover the intake grille and the outlet port.
  • Do not apply any heavy pressure to radiator fins.
  • Do not climb on, place objects on, or hang objects from this product.
  • Do not place any other electrical products or household belongings under this product. Dripping condensation from this product might get them wet, and may cause damage or malfunction of your property.
  • Do not expose this product directly to water.
  • Do not use this product for preservation of food, plants, animals, precision equipment, art work, or other objects. This may cause quality deterioration of those items.
  • Do not expose animals or plants to the direct airflow.
  • Do not drink the drainage from the air conditioner.
  • Do not pull the power supply cable.

CAUTION

  • Do not touch the aluminum fins of heat exchanger built-in this product to avoid personal injury when you maintain the unit.
  • Do not stand on unstable steps when operating or cleaning this product. It may overturn and can cause injury.

NAME OF PARTS

  • The remote controller is optional. You can select from the following types of remote control.
    • Wireless remote controller
    • Wired remote controller
    • Wireless LAN control
  • To check the available model of remote controller, please consult authorized service personnel.
  • For detailed instructions on how to operate, please refer to the operating manual of the remote controller.

Fujitsu-ABY125-KR-Air-Conditioner-fig-2

  • The number and positions of left/right air direction louvers differ by the model.

BASIC OPERATIONS

NOTES: For detailed instructions on how to operate, please refer to the operating manual of the remote controller.
The operation mode and the temperature setting range are shown in the following table.

Fujitsu-ABY125-KR-Air-Conditioner-fig-19

Auto mode
The air conditioner selects the appropriate operation mode (Cooling or Heating) according to your room’s present temperature.

Fujitsu-ABY125-KR-Air-Conditioner-fig-20

  • When Auto mode is first selected, the fan will operate at low speed for about a few minutes, during which time the indoor unit detects the room conditions and selects the operation mode.
  • When the air conditioner has adjusted your room’s temperature to near the thermostat setting, it will begin monitor operation.
  • In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently changes, the air conditioner will once again select the appropriate operation (Heating, Cooling) to adjust the temperature to the value set in the thermostat.
  • If the mode automatically selected by the unit is not what you wish, select one of the mode operation (Heating, Cooling, Dry, Fan).

Cooling mode
Use to cool your room.
NOTES:

  • Set the temperature lower than the current room temperature, otherwise, the fan alone will operate.
  • The indoor unit fan may stop from time to time to perform Fan control for energy saving that enables power-saving operation by stopping the rotation of the indoor unit fan when the outdoor unit is stopped.
  • In initial setting, this function is activated.
  • To deactivate the function, refer to the operating manual of the remote controller or consult the authorized service personnel.

Dry mode
Use for gently cooling while dehumidifying your room.
NOTES:

  • You cannot heat the room.
  • Set the temperature lower than the current room temperature, otherwise, the operation will not operate.
  • The unit will operate at low speed in order to adjust room humidity. The indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when adjusting room humidity.
  • The fan speed cannot be changed manually.

Fan mode
Use to circulate the air throughout your room.
NOTES: You cannot set the temperature.

Heating mode
Use to warm your room.
NOTES:

  • Set the temperature higher than the current room temperature, otherwise, the operation will not operate.
  • At the beginning of the operation, the indoor unit fan rotates at very low speed for a few minutes to warm the internal indoor unit. After the period, the indoor unit fan will switch to the selected fan speed.
  • When the room temperature is very low, frost may form on the outdoor unit, and its performance may be reduced. In order to remove such frost, the unit will automatically enter the defrost cycle from time to time. During Automatic defrosting operation, the Heating operation will be interrupted.
  • After the start of Heating operation, it takes sometime before the room gets warmer.

AIRFLOW SETTINGS

NOTES: For detailed instructions on how to operate, please refer to the operating manual of the remote controller.

Fan speed setting

  • The fan speed changes as follows.

Fujitsu-ABY125-KR-Air-Conditioner-fig-4

  • When Auto is selected, the fan speed is automatically adjusted according to the operation mode.
    • Heating: The fan will operate at very low speed when the temperature of the air issued from the indoor unit is low.
    • Cooling: As the room temperature approaches that of the set temperature, the fan speed becomes slower.
    • Fan: The fan runs at medium fan speed.
Airflow direction setting

You can set the following items.

  • Vertical airflow direction setting
  • Swing operation setting (up/down)
    NOTES: The Swing operation may stop temporarily when the indoor unit fan is rotating at very low speed or is stopped.

Vertical airflow direction

  • By the wireless remote controller, the vertical airflow direction can be selected from 7 positions.

Fujitsu-ABY125-KR-Air-Conditioner-fig-5
Fujitsu-ABY125-KR-Air-Conditioner-fig-6

  • By the wired remote controller or the wireless LAN control, the vertical airflow direction can be selected from 4 positions.

Fujitsu-ABY125-KR-Air-Conditioner-fig-7

NOTES:

  • Do not adjust the airflow direction louvers by hand it could result in improper operation. In this case, stop operation and restart. The louvers should begin to operate properly again.
  • The airflow setting from the wireless remote controller will not be reflected in the display of the wired remote controller or the mobile app.
  • In the Cooling or Dry mode, position 1-3 is recommended to prevent condensation drips damaging your property.
    • In the wireless remote controller: If position 5-7 keeps for 60 minutes or more, the airflow direction changes to position 4 automatically.
    • In the wireless remote controller or the wireless LAN control:If position 4 keeps for 60 minutes or more, the airflow direction changes to position 3 automatically. The airflow indicator will not change.
  • During the Auto mode operation, for the first minute after beginning operation, airflow will be fixed and cannot be adjusted.
  • Even if the airflow direction is set, it may operate at a different position in the following operation.
    • at the start of Heating operation
    • during the Automatic defrosting operation
    • during the Auto mode operation
  • In the Auto or Heating mode, the airflow direction stay position 1 for a while from the start of the operation.
  • When used in a room with infants, children, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.

Horizontal airflow direction
CAUTION
Before you adjust the horizontal airflow direction, make sure that the vertical airflow direction louver has been stopped completely.
Adjust two knobs by hand.

TIMER OPERATIONS

On timer or Off timer

  • The On timer starts the operation at your desired time.
  • The Off timer stops the operation at your desired time.

Program timer

  • The Program timer operates as the combination of the On timer and Off timer.
  • You can set the Program timer only within a span of 24 hours.

Sleep timer
NOTES: This function is available only when using the wireless remote controller.

  • The Sleep timer supports your comfortable sleep by moderating the air conditioner operation gradually.
  • The time setting of the Sleep timer changes as follows:

Fujitsu-ABY125-KR-Air-Conditioner-fig-8

  • During the Sleep timer operation, the setting temperature changes as the following figure.

Fujitsu-ABY125-KR-Air-Conditioner-fig-9

  • After the set time has elapsed, the air conditioner operation turns off.

Auto-off timer
NOTES: Depending on the remote controller, this function may not be available.

  • The Auto-off timer stops the air conditioner operation automatically after the set time has passed since the operation started.
  • You can set time from 30 minutes to 240 minutes (4 hours).

ENERGY SAVING OPERATIONS

Economy operation
NOTES: Depending on the remote controller, this function may not be available.
It saves more electricity than other operation modes by changing the set temperature to a moderate setting.

  • Cooling/Dry
    The room temperature will be few degrees higher than the set temperature

  • Heating
    The room temperature will be few degrees lower than the set temperature
    NOTES:

    • In the Cooling, Heating, or Dry mode, the maximum output of this operation is approximately 70 % of usual operation. If the room is not cooled or heated well during the Economy operation, select normal operation.
    • This operation cannot be performed during the temperature monitoring by the Auto mode.

Fan control for energy saving

  • In the Cooling or Dry operation, when the room temperature reaches the set temperature, the indoor unit fan rotates intermittently to save power.
  • This function is on at the time of purchase.
  • To deactivate this function, refer to the operation manual of the remote controller or consult authorized service personnel.
  • Even if the setting is deactivated, if the fan speed is set to Auto in Cooling or Dry mode, this function still works to suppress the diffusion of circulated indoor humidity.

OTHER OPERATIONS

10 °C Heat operation
NOTES: This function is available only by wireless remote controller.
10 °C Heat operation maintains the room temperature at 10 °C so as to prevent the room temperature to drop too low.
NOTES:

  • During the 10 °C Heat operation, only the vertical airflow setting is valid.
  • When the room temperature is warm enough, This operation will not be performed.

Set temperature range function (for administrator)
NOTES: This function is available only by wired remote controller.
You can restrict the settable temperature range for each operation mode (Auto, Cooling/Dry, or Heating).

Set temperature auto return function (for administrator)
NOTES: Depending on the remote controller, this function may not be available.
By setting this function, the operation status is changed to the set mode and temperature after the set time passes.

CLEANING AND CARE

CAUTION

  • Before cleaning the indoor unit, be sure to turn it off and disconnect all the power supply.
  • Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an effect on the proper working or performance of the air conditioner.
  • The fan operates at high speed inside the unit, and could result in personal injury.
  • If the filter cleaning involves high-place work, please consult the professional technical service personnel.
  • Do not touch the aluminum fins of heat exchanger built-in the indoor unit to avoid personal injury when you maintain the unit.

When cleaning the unit, do not use water hotter than 40 °C, harsh abrasive cleansers, or volatile agents like benzene or thinner.

Fujitsu-ABY125-KR-Air-Conditioner-fig-11

Cleaning air filter
Prepare the following items before cleaning: a screwdriver, a vacuum cleaner (You can use mild detergent and warm water instead of the vacuum cleaner.)

  1. Remove the screws with a screwdriver.

The number of screws and latches differs by model.

  * 18/22 model: 4 places
  * 24/30 model: 5 places
  * 36/45/54 model: 6 places
  1. Push the latches of the intake grille to release. The intake grille will hang down.

Fujitsu-ABY125-KR-Air-Conditioner-fig-13

  1. Remove the air filters.
    Release the bottom hooks. Then, pull down the air filter to remove.

Fujitsu-ABY125-KR-Air-Conditioner-fig-14
NOTES: The number and positions of the air filter hooks differ by the model.

  1. Remove the dust in either of the following ways.
    • Cleaning with vacuum cleaner.
    • Washing with mild detergent and warm water. After washing, dry the air filters thoroughly in shade.
  2. Install the air filters.
    Fit the air filter to the top hooks of the intake grille. Then, push the air filter until it snaps.

Fujitsu-ABY125-KR-Air-Conditioner-fig-15

  1. Close the intake grille.
    Return the intake grille to the horizontal position and pull the latches until it snaps.

Fujitsu-ABY125-KR-Air-Conditioner-fig-16

  1. Fix the screws.

NOTES: If dirt accumulates on the air filter, airflow will be reduced, operating efficiency will lower, and the noise will increase.

After extended non-use of the unit
If you do not use this product for 1 month or more, perform the Fan mode operation for half a day to dry the internal parts thoroughly before you perform normal operation.

Additional inspection

  • After long period of use, accumulated dust inside the indoor unit may reduce the product performance even if you have maintained the unit with instructed daily care or cleaning procedures written in this manual.
  • In such a case, a product inspection is recommended.
  • For more information, consult authorized service personnel.

Filter indicator reset (Special setting)
This function can be used if set correctly during installation. Please consult authorized service personnel in order to use this function.

  1. Clean the air filter when the filter indicator appears.
  2. After cleaning, reset the filter indicator.
  • For detailed instructions on how to operate, please refer to the operating manual of the remote controller.

GENERAL INFORMATION

Inverter
At the start of operation, large amount of power is used to bring the room quickly to the desired temperature. Afterwards, the unit automatically switches to a low power setting for economic and comfortable operation.

Heating performance

  • This air conditioner operates on the heat-pump principle, absorbing heat from air outdoors and transferring that heat to the indoor unit. As a result, the operating performance is reduced as outdoor air temperature drops.
  • If you feel that the heating performance is insufficient, we recommend you to use this air conditioner in conjunction with other kinds of heating appliance. please consult with your installation technician to ensure the unit is correctly sized for the room space required.
  • Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air conditioner until the room is heated.

Automatic defrosting operation

  • When outdoor temperature is very low with high humidity, frost may form on the outdoor unit during the Heating operation, and it could reduce the operating performance of the product.
  • For frost protection, a microcomputer-controlled automatic defrost function is equipped in this air conditioner.
  • If frost forms, the air conditioner will temporarily stop, and defrost circuit will operate briefly (maximum of 15 minutes.)
  • If frost forms on the outdoor unit after the Heating operation, the outdoor unit will stop automatically after it operates for a few minutes. Then the automatic defrosting operation starts.
  • If you set to the Heating operation during the Automatic defrosting operation, the Automatic defrosting operation will continue. The Heating operation will begin after completion of defrosting. As a result, it may take some time before warm air is emitted.

Auto-restart function

  • In Event of Power Interruption
  • Should the power supply to the air conditioner be interrupted by a power failure, the air conditioner will restart automatically in the previously selected mode once the power is restored.

Malfunctions caused by other electrical devices

  • Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner.
  • If you encounter such a malfunction, disconnect the power supply once.
  • Then reconnect it, and resume operation by using the remote controller.

Indoor unit temperature and humidity range
Permissible ranges of temperature and humidity are as follows:

Fujitsu-ABY125-KR-Air-Conditioner-fig-18

  1. If the air conditioner is used continuously for many hours, water may condense on the surface and drip.
    • If the unit is operated under the conditions except the permissible temperature range, the air conditioner operation may stop because of the automatic protection circuit working.
    •  Depending on the operating conditions, the heat exchanger may freeze, causing water leakage or other malfunction. (in the Cooling or Dry mode).

When indoor and outdoor temperatures are high
When both indoor and outdoor temperatures are high during use of the Heating mode, the outdoor unit’s fan may stop at times.

Low ambient cooling
When the outdoor temperature drops, the outdoor unit’s fans may switch to low speed, or one of the fans may stop intermittently.

Other information

  • Do not use the air conditioner for any purpose other than room cooling/dry, room heating or fan.
  • For the permissible ranges of temperature and humidity for the outdoor unit, refer to the outdoor unit installation manual.
  • During the Heating mode, the top of the indoor unit may become warm, but this is due to the fact that coolant is circulated through the indoor unit even when it is stopped; it is not a malfunction.

OPTIONAL PARTS

Remote control

  • The remote controller is optional. You can select from the following types of remote control.

    • Wireless remote controller
    • Wired remote controller
    • Wireless LAN control
  • To check the available model of remote controller, please consult authorized service personnel.
    NOTES: Depending on the remote control, some function may be restricted. Please refer to the operating manual of the remote controller or WLAN adapter for details.

  • You can use both wireless and wired remote controller together. However, some functions of the wireless remote controller may be restricted.

Multiple remote controller

  • You can connect two wired remote controllers to one air conditioner.
  • Either remote controller can control the air conditioner.
  • However, the timer functions cannot be used by the secondary unit.

Group control

  • One wired remote controller can control up to 16 air conditioners. All of the air conditioners will be operated with the same settings.
  • You cannot use group control and wireless LAN control together.

TROUBLESHOOTING

WARNING
In following events, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult your dealer or authorized service personnel.
As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off.

  • Unit smells of something burning or emits smoke
  • Water leaks from the unit

Does not operate at all.

  • Has there been a power outage?
    In this case, the unit restarts automatically after the power supply is resumed. (Refer to page 6.)

  • Has the circuit breaker been turned off?
    Turn on the circuit breaker.

  • Has a fuse blown out or the circuit breaker been tripped?
    Replace the fuse or reset the circuit breaker.

  • Is the timer operating?
    To check or deactivate the timer setting, Refer to the operating manual of the remote controller.

Poor cooling or heating performance.

  • Is the unit operating under the conditions except the permissible temperature range?
    In this case, the air conditioner may stop because of the automatic protection circuit working.

  • Is the air filter dirty?
    Clean the air filter. (Refer to page 5.)

  • Is the intake grille or outlet port of the indoor unit blocked?
    Remove the obstructions.

  • Is the room temperature adjusted appropriately?
    To change the setting temperature, refer to the operating manual of the remote controller.

  • Is a window or door left opened?
    Close the window or the door.

  • Is the fan speed set to Quiet?
    To change the fan speed, refer to the operating manual of the remote controller.

  • In the Cooling mode > Is direct or strong sunlight shining into the room?
    Close the curtains.

  • In the Cooling mode > Are there other heating apparatus or computers operating, or too many people in the room?
    Turn the heating apparatus or computers off, or set the temperature lower.

Airflow is weak or stops.

  • Is the fan speed set to Quiet?
    To change the fan speed, refer to the operating manual of the remote controller.

  • Has the Fan Control for Energy Saving set? In this case, the indoor unit fan may stop temporarily while the Cooling operation.
    To deactivate the Fan Control for Energy Saving, refer to the operating manual of the remote controller or consult authorized service personnel.

  • This function cannot be deactivate when the fan speed is set to Auto.

  • In the Heating mode > Have you just started the operation?
    In this case, the fan rotates at very low speed temporarily to warm up the internal parts of the unit.

  • In the Heating mode > Is the room temperature higher than the set temperature?
    In this case, the outdoor unit stops and the indoor unit fan rotates at very low speed.

  • In the Heating mode > Is the Automatic defrosting operation working?
    In this case, the indoor unit stops for maximum of 15 minutes. (Refer to page 6.)

  • In the Dry mode?
    The indoor unit operates at low fan speed to adjust the room humidity, and may stop from time to time.

  • In the Auto mode?
    While the monitoring operation, the fan rotates at very low speed.

Airflow direction does not change according to the setting or does not change at all.

  • In the Auto mode
    In the Auto mode, the airflow direction is set automatically.

  • In the Heating mode
    Have you just started the operation?
    In this case, the airflow direction keeps the default position for a while.

  • In the Heating mode
    During the Automatic defrosting operation, the airflow direction is set automatically.

Humidity does not drop.
In the Dry operation

  • If the setting temperature is high, the humidity may not drop.
  • To lower the humidity, lower the setting temperature.

Noise is heard.

  • Is the unit operating, or immediate after stopping operation?
    In this case, refrigerant flowing sound may be heard. It may be particularly noticeable for 2-3 minutes after starting operation.

  • Do you hear a slight squeaking sound during the operation?
    This sound is produced by the minute expansion and contraction of the front panel caused by temperature change.

  • In the Heating mode > Do you hear a sizzling sound?
    This sound is produced by the Automatic defrosting operation. (Refer to page 6.)

Smell coming from the unit.
The air conditioner may absorb various smells generated from interior textile, furniture, or cigarette smoke. These smells may be emitted during the operation.

Mist or steam is emitted from the unit.

  • In the Cooling or Dry mode
    A thin mist may be generated by condensation formed with sudden cooling process.

  • In the Heating mode
    Is the Automatic defrosting operation working? In this case, steam may rise from the outdoor unit. (Refer to page 6.)

Outdoor unit emits water.
In the Heating mode?
The outdoor unit may emit water generated by the Automatic defrosting operation. (Refer to page 6.)

Operation is delayed after restart.

  • Has the power supply turned from off to on suddenly?
    In this case, the compressor will not operate for about 3 minutes to prevent a blowout of the fuse.

  • Has the electrical breaker is turned off then on again?
    In this case, the protection circuit will operate for about 3 minutes.

Immediately stop operation and turn off the electrical breaker in following cases. Then consult authorized service personnel.

  • The problem persists even if you perform these checks or diagnostics.
  • Error sign is shown on the wired remote controller display or the indicator lamps on the IR receiver unit.
    NOTES:
    For any troubleshooting related to the W-LAN control, refer to the setting manual for W-LAN adapter or the mobile app installed in your smartphone or tablet PC.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FUJITSU User Manuals

Related Manuals