BESTTEN DS08E Super Slim Dimmer Switch User Manual
- June 17, 2024
- Bestten
Table of Contents
BESTTEN DS08E Super Slim Dimmer Switch
Product Information
Specifications
- Voltage: 120VAC 60Hz
- Maximum Wattage: Dimmable LED/CFL 300W
Bulb Compatibility
The BESTTEN DS08 Dimmer is compatible with most Dimmable LED, Dimmable CFL,
and Incandescent Bulbs or 120V Halogen Fixtures. It is recommended to use only
high-quality dimmable LED, dimmable CFL, or incandescent bulbs. While the
BESTTEN DS08 Dimmer has a wide range of compatibility, there may be some
lights sold in the market that are incompatible, usually of low quality. Major
brands from popular big box stores have proven to have the most reliable
compatibility.
Product Usage Instructions
Installation Instructions
Step 1: Turn off Power
Before starting any work, turn off the power at the breaker or fuse to
ensure that there is no electricity flowing to the wall box.
Step 2: Identify Your Wiring Application (Most Common)
If the wiring in the wall box does not resemble any of these
configurations, it is recommended to consult an electrician.
Single Pole Wiring:
- Line (Hot)
- Ground
- Load
3-Way Wiring:
- Line or Load Common (See important instructions below)
- Ground
- First Traveler
- Second Traveler
Important Note for 3-Way Applications: Replace only one 3-way switch at a time and test after each installation. When replacing an old switch or dimmer in a 3-way application, it is important to identify and tag the Common (Line or Load) and Traveler wires before removing the old switch or dimmer. Taking a picture of how the wires are connected to the old switch or dimmer can be helpful during the installation of the new dimmer.
Step 3A: Single Pole Wiring Application
This wiring application is used for 3-way installations only. For single
pole installations, cover with a wire nut.
- Red and White: Not used in single pole application. Insulate this wire with a wire nut.
- Red: Load
- Neutral: Not required
- Black: Hot
- Green: Ground
The black wire on the dimmer should be connected to the Line or Hot Wire, which is the live wire coming from the breaker or fuse panel. The red wire on the dimmer should be connected to the Load wire, which goes to the light. The green wire on the dimmer should be connected to the ground, usually a bare copper or green wire in the wall box. No neutral wire is required for this dimmer, making it suitable for houses of all ages.
FAQ (Frequently Asked Questions)
-
Can I use this dimmer with non-dimmable LED bulbs?
No, this dimmer is designed to be used only with compatible Dimmable LED, Dimmable CFL, or Incandescent Bulbs or 120V Halogen Fixtures. -
Can I use multiple dimmers in a 3-way circuit?
No, only one dimmer should be used per 3-way circuit. -
Can I use the dimmer to control a receptacle or fan?
No, the dimmer should not be used to control a receptacle, fan, or any motor- operated appliance. It is specifically designed for controlling lighting fixtures as specified. -
Is a neutral wire required for installation?
No, this dimmer does not require a neutral wire. -
What should I do if I am unsure about any part of the installation?
If you are unsure about any part of the installation, it is recommended to consult a qualified electrician.
Super Slim Dimmer Switch for LED / Compact Fluorescent / Incandescent Single
Pole / 3-Way Applications
Model Number: USP-DS08
WARNINGS AND CAUTIONS
- Use only with compatible Dimmable LED / Dimmable CFL / Incandescent Bulbs or 120V Halogen Fixtures.
- Use only ONE dimmer per 3-way circuit.
- DO NOT MIX BULB, TYPES, BRANDS, OR MODELS when multiple bulbs are used.
- DO NOT use dimmer to control a receptacle, fan, or other motor operated appliance, transformer-supplied appliance, or any lighting fixtures other than those specified.
- To be installed and/or used in accordance with all applicable electrical codes and regulations.
- No neutral wire required.
- If you are unsure about any part of these instructions, please consult a qualified electrician.
SPECIFICATIONS
-
Voltage …………………………………………………………………….. 120VAC 60Hz
-
Maximum Wattage ……………………………………. Dimmable LED/CFL 300W
Incandescent/Halogen 600W -
Switch Type ………………………………………………….. Single Pole and 3-Way
-
Operation Temperature Range …………………….. 32°F (0°C) – 104°F (40°C)
-
Certifications …………………………………………………………. ETL/cETL Listed
BULB COMPATIBILITY
- BESTTEN DS08 Dimmer is compatible with most Dimmable LED, Dimmable CFL and Incandescent Bulbs or 120V Halogen Fixtures.
- USE ONLY HIGH QUALITY Dimmable LED, Dimmable CFL, or Incandescent Bulbs.
- Although the BESTTEN DS08 Dimmer has one of the widest ranges of compatibility with dimmable LED, CFL, and Incandescent lights on the market, there are a small number of lights sold that are incompatible with this dimmer. These are usually of low quality.
- Major brands from the most popular big box stores have proven to have the most reliable compatibility.
INSTALLATION INSTRUCTIONS
STEP 1
Turn off power at breaker or fuse, ensuring power is off at the wall box
before starting work.
STEP 2 Identify Your Wiring Application (Most Common)
NOTE : If the wiring in the wall box does not resemble any of these
configurations, please consult an electrician.
Single Pole
- 1. Line (Hot)
- 2. Ground
- 3 Load
3-Way
-
1. Line or Load Common
(See important instructions below) -
2 Ground
-
3. First Traveler
-
4. Second Traveler
IMPORTANT FOR 3-WAY APPLICATIONS
REPLACE ONLY ONE 3-WAY SWITCH AT A TIME, test after each installation.
When replacing an old switch or dimmer in a 3 way application, it is important
that the Common (Line or Load) and Traveler wires must be identified and
tagged BEFORE the old switch or dimmer is removed. Taking a picture of how the
wires are connected to your old switch or dimmer before it is removed can aid
in identifying these wires during the installation of the new dimmer. On your
old 3-way switch or dimmer one of the terminal screws will usually be a
different color than the other two terminal screws or labeled C or Common. Tag
the wire connected to this terminal as Common (Line or Load). The wires
connected to the two other terminals will be the traveler wires and should be
tagged as Traveler. If there are wires instead of terminals, as is common on
dimmers, there will often be a black and two other colored wires, usually red
or red and brown (Green is Ground). Tag the wire connected to the black wire
on the old dimmer as Common (Line or Load). The other two wires can be tagged
as Traveler.
STEP 3 A Single Pole Wiring Application
This wire is used in 3-way installations only. For single pole installations
cover with wire nut.
- Black wire on the dimmer connects to the Line or Hot Wire (Live wire coming from the breaker or fuse panel).
- Red Wire on the dimmer connects to the Load wire (The wire that goes to the light).
- Green wire on the dimmer connects to ground. This is usually a bare copper or green wire in the wall box.
- The Red and White wire is not used in a single pole application. Insulate this wire with a wire nut.
- No neutral wire required, suits houses of all ages.
With each connection twist the wires together and secure with a wire nut. Check to ensure each connection is tight and secure and there are no bare wire visible.
STEP 3B 3-Way Wiring Application
IMPORTANT : In a 3-way circuit, only one dimmer can be used
- Black wire on the dimmer connects to the Common (Line or Load) Wire.
- The Red, and Red and White wires on the dimmer connect to the Traveler wires. These two wires are interchangeable in this application.
- Green wire on the dimmer connects to ground. This is usually a bare copper or green wire in the wall box.
- No neutral wire required, suits houses of all ages.
With each connection twist the wires together and secure with a wire nut. Check to ensure each connection is tight and secure and there are no bare wire visible.
STEP 4 Mounting Dimmer Carefully position the wires in the wall box to make room for the dimmer. BESTTEN DS08 dimmers are of a slim design to make this step easier. Using the provided mounting screws, secure the dimmer to the wall box.
STEP 5 Test Dimmer
- Turn on power at the breaker or fuse panel.
- With the dimmer slide in the brightest (all the way up) position check the ON/OFF function of the rocker switch.
- Check the function of the dimmer by slowly moving the dimmer slide back and forth, noting how the lights dim.
- If you are satisfied with the operation of the dimmer. Finish the dimmer installation by installing a wall plate.
If lights experience any of the following, proceed to STEP 6
- Lights flicker at low settings.
- Lights do not come on until dimmer is at high setting.
- Lights turn off when being dimmed.
- Lights do not turn on at the lowest setting.
- Lights are too bright at lowest setting.
STEP 6 Adjust Dimming Range
To adjust the dimming range you can rotate the Adjustment Wheel to raise or
lower the minimum brightness of your lights. The Adjustment wheel can also be
used to eliminate flickering at the lowest setting.
-
Turn ON the rocker switch and move the dimmer slide to the lowest (all the way down) position.
-
Rotate the Adjustment Wheel clockwise all the way down to the highest position.
NOTE : If the wheel stops in either direction, do not continue to rotate it. -
Rotate the Adjustment Wheel counter-clockwise up slowly until the lowest desired light level is achieved and the lights are not flickering.
-
With the dimmer slide in the lowest (all the way down) position, check to make sure the lights turn on and do not flicker. If not, rotate the Adjustment Wheel clockwise slightly and check again.
-
Once you are satisfied with the operation of the dimmer. Finish the dimmer installation by installing a wall plate.
TROUBLESHOOTING
Please carefully read any troubleshooting steps that apply.
Problem 1 Lights flicker at low settings
Refer to STEP 6 Rotate Adjustment wheel to raise starting voltage to eliminate
flickering at low settings.
Problem 2 Lights flicker at all settings
- Ensure all lights are marked as the dimmable type, are the same brand and model and wattage.
- Change brand or model of bulb ensuring they are dimmable to check compatibility.
- Ensure only one dimmer is installed in a 3-way circuit.
- Ensure the maximum wattage is not exceeded for type of light (300W for LED and CFL.600W for Incandescent).
- Ensure all electrical connections are secure on both dimmer and lights.
Problem 3
A: Lights turn off when being dimmed
B: Lights do not come on until dimmer is at high setting
- Refer to STEP 6 Rotate Adjustment Wheel to raise starting voltage to ensure lights turn on at lowest setting.
- Ensure all lights are marked as the dimmable type, are the same brand and model and wattage.
- Change brand or model of bulb ensuring they are dimmable to check compatibility.
Problem 4 Bulbs dim at different rates or act differently at settings
Ensure all lights are of the same brand, wattage and model. It helps if all
bulbs are even from the same batch as variances in light manufacturing can
cause bulbs to act differently at lowest setting levels.
Problem 5 Dimmer is not working in 3-way position
- Ensure only one dimmer is installed in a 3 way circuit.
- Refer to Diagram in STEP 3B. Check all wiring of dimmer and 3-way switch ensuring Line, Load and traveler wires have all been identified and connected correctly, to both the dimmer and the switch. There is no standard for wire color in a 3 way circuit, consult an electrician if help is needed to identify the wires.
Problem 6 Audible buzzing or humming from dimmer
- Ensure only one dimmer is installed in a 3 way circuit.
- Ensure all lights are marked as the dimmable type, are the same brand, wattage and model or change brand of bulb.
- Ensure the maximum wattage is not exceeded for type of light (300W for LED and CFL.600W for Incandescent).
Problem 7 Lights are too bright at lowest setting
- Refer to STEP 6 Rotate Adjustment Wheel to lower starting voltage to ensure lights are adequately dimmed at lowest setting.
- Ensure all lights are marked as the dimmable type, are the same brand and model or change brand or model of bulb.
If all troubleshooting steps have been carefully followed and the problem continues, please contact a qualified electrician or customer support for more information.
WARRANTY
BESTTEN warrants to the original customer that this product is free of defects
in materials and workmanship for one year from the purchase date. Within this
period, simply contact BESTTEN CARE with proof of purchase and reason of
claim. We will replace the product for free.
Any product which is subject to misuse or accidental damage is excluded from
this warranty.
support@ibestten.com
1-800-358-6160 (Mon-Fri 9AM-5PM PST)
For more products from BESTTEN, please visit our website
www.ibestten.com
Read User Manual Online (PDF format)