Oase 1500 Filtral UVC Pump Instruction Manual

June 17, 2024
Oase

Oase 1500 Filtral UVC Pump

Product Information

Specifications:

  • Bemessungsspannung: 230 V AC
  • Bemessungsfrequenz: 50 Hz
  • Leistungsaufnahme : 18 W (Filtral UVC 1500), 36 W (Filtral UVC 3000), 50 W (Filtral UVC 6000), 74 W (Filtral UVC 9000)
  • Leistung UVC-Lampe TC-S: 5 W (Filtral UVC 1500), 9 W (Filtral UVC 3000), 13 W (Filtral UVC 6000), 19 W (Filtral UVC 9000)
  • Schlauchanschluss Abzweigventil: 13/19/25 mm
  • Luftschlauch bei einer Tauchtiefe:
    • 0,3 m: 560 l/h
    • 0,4 m: 1200 l/h
    • 0,6 m: 0,9 l/h
    • 0,8 m: 1,8 l/h
    • 1,0 m: 35 l/h
    • 1,2 m: 116 l/h
  • Filterschaum (blau) Anzahl ppi: 28
  • Filterschaum (rot) Anzahl ppi : 105
  • Anzahl Beutel Filterkeramik : 21
  • Abmessungen (Breite x Höhe x Tiefe): 97 mm x 89 mm x 74 mm
  • Gewicht: 0,3 kg (Filtral UVC 1500), 1,0 kg (Filtral UVC 3000), 1,5 kg (Filtral UVC 6000), 3,4 kg (Filtral UVC 9000)

Product Usage Instructions:

Montage:

Betrieb mit Wasserspiel:

  • Verbinden Sie den Filtral UVC am zweiten Ausgang des Abzweigventils.
  • Ziehen Sie die Schraubverbindungen handfest an.
  • Für Filtral UVC 1500 verwenden Sie die Schraubverbindung FTL0026.
  • Für Filtral UVC 3000, 6000, 9000 verwenden Sie die Schraubverbindung FTL0034.

Oase 1500 Filtral UVC Pump

  • Verbinden Sie den Filtral UVC direkt am Ausgang des Abzweigventils.
  • Ziehen Sie die Schraubverbindungen handfest an.
  • Für Filtral UVC 1500 verwenden Sie die Schraubverbindung FTL0038.
  • Für Filtral UVC 3000, 6000, 9000 verwenden Sie die Schraubverbindung FTL0035.

Aufstellen:

Befestigen Sie den Filtral UVC mithilfe der Schnur am Teichufer. Ziehen Sie die Schnur fest an den beiden Schrauben auf.

Inbetriebnahme:

Bevor Sie den Filtral UVC einschalten, stellen Sie sicher, dass die Netzspannung vorhanden ist.

Reinigung und Wartung:

Es ist wichtig, den Filtral UVC regelmäßig zu reinigen und zu warten, um eine optimale Leistung zu gewährleisten.

  • Filtermedien reinigen: Entfernen Sie die Filtermedien und spülen Sie sie gründlich mit Wasser ab.
  • Filterpumpe reinigen: Reinigen Sie die Filterpumpe gemäß den Anweisungen in der Bedienungsanleitung.
  • UVC-Lampe ersetzen: Beachten Sie die Sicherheitshinweise, bevor Sie die UVC-Lampe ersetzen. Stellen Sie sicher, dass der Filtral UVC ausgeschaltet und vom Stromnetz getrennt ist.

WARNING

  • Disconnect all electrical devices in the water from the power supply before reaching into the water. Otherwise, there is a risk of severe injuries or death by electrocution.
  • Only operate the unit if no persons are in the water.
  • This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow chil-dren to carry out cleaning and user maintenance under supervision.

Safety information

Electrical connection

  • Special regulations apply for electrical installation in outdoor spaces. Only a qualified electrician may perform the electrical installation.
    • The qualified electrician has the necessary professional training, knowledge and experience to perform electrical installation in outdoor spaces. The electrician can detect potential dangers and knows how to adhere to regional and national standards, regulations and directives.
    • For your own safety, please consult a qualified electrician.
  • Only connect the unit if the electrical data of the unit and the power supply match.
  • Only plug the unit into a correctly installed outlet.
  • The device is to be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
  • Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
  • Protect open plugs and sockets from moisture.

Safe operation

  • Never operate the UVC lamp outside the housing or in a damaged housing. The ultraviolet radiation can burn the skin and eyes.
  • Do not use the unit, if electrical lines or the housing are damaged.
  • The supply cord cannot be replaced. If the cord is damaged, the appliance should be scrapped.
  • Do not carry or pull the unit by its power cable.
  • Route lines in such a way that they are protected from damage and do not present a tripping hazard.
  • Never carry out technical changes to the unit.
  • Only carry out work on the unit that is described in this manual.
  • Only use original spare parts and accessories.

Intended use

Only use the product described in this manual as follows:

  • For cleaning garden ponds.
  • For operation with clean water.
  • While adhering to the technical specifications. (→ Technical data)

The following restrictions apply to the unit:

  • This product is not suitable for general lighting but is only intended for the purpose described here.
  • Do not use in swimming ponds.
  • The UVC clarifier installed in the device kills algae and bacteria in the pond water. The UVC lamp may never be used for any other purpose or outside of the housing.
  • Never use the unit with fluids other than water.
  • Never run the unit without water.
  • Do not use for commercial or industrial purposes.
  • Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.

Product Description

Overview

Oase-1500-Filtral-UVC-Pump-fig-1

Oase-1500-Filtral-UVC-Pump-fig-2

Properties

Filtral UVC 1500, 3000, 6000, and 9000 is an underwater filter with integrated pump and UVC clarified. The filter media and the UVC clarifier integrated in the device remove dirt, algae and bacte-ria.

Symbols on the unit

  • The unit is dust-tight and water-tight down to 2 m.
  • Dangerous UVC radiation
  • Remove the unit in the event of freezing temperatures
  • Fragile, handle with care. Risk of cuts.
  • Do not dispose of the unit with normal household waste
  • Read the operating instructions

Assembly

Operation with water feature

When operating together with a water feature, the device should be set up horizontally. The branch valve is mounted together with the nozzle pipe and nozzle insert at the device’s output.

The branch valve is mounted together with the nozzle pipe and nozzle insert at the device’s output.

  • Depending on the nozzle insert used, a specific water feature is created. Connection to the second output of the branch valve:
  • Hose connection for a watercourse/water feature.
  • Filter 1500: Operation is possible either with the fountain or with the optionally available Venturi nozzle.
  • Filter 3000/6000/9000: When using the Venturi nozzle, run the air hose along the nozzle pipe and secure in the holder on the nozzle connection. The air hose must be able to suck in air, no water may be allowed to enter the air hose. Hand-tighten the bolt connections.

Filtral UVC 1500

Filtral UVC 3000, 6000, 9000

Operation without a water feature

When operating without a water feature, the device can be set up either horizontally or hung up.

  • (→ Set up the device horizontally)
  • (→ Hang up the device)

Connection to the output of Filtral 1500:

  • Use a branch valve in order to connect up the hose for a watercourse/water feature.
  • Connection for a Venturi nozzle (optionally available, 70364).
  • Do not connect anything to the output.

Connection to the output of Filtral 3000/6000/9000:

  • Connecting up the Venturi nozzle provided with scope of delivery (possible with and without a branch valve).
  • Hose connection for a watercourse/water feature (possible with and without a branch valve).
  • Do not connect anything to the output.

Hand-tighten the bolt connections.

Oase-1500-Filtral-UVC-Pump-fig-11

Installation

Set up the device horizontally

Observe the following conditions:

  • Ensure that the connection to the power supply is at least 2 m from the edge of the pond.
  • Place the device so that the filter housing is always below the water level.
  • Position the device so that the nozzle insert is above the water level.
  • Place the unit in the pond on horizontal, firm and sludge-free ground.

Hang up the device

Observe the following conditions:

  • Ensure that the connection to the power supply is at least 2 m from the edge of the pond.
  • Place the device so that the filter housing is always below the water level.
  • Only operate the device without water feature.
  • Screw the two screws into the filter base and hang the device on the two screws with a cord. Fasten the cord on the side of the pond.

Set-up fountain/feature

In order to adapt the water feature, the length and the vertical position of the nozzle pipe need to be altered. The water flow rate can be regulated using the two flow-rate regulators on the branch valve. How to proceed:

  1. Set the nozzle pipe to the length required.
  2. Loosen the union nut, align the nozzle pipe vertically and hand-tighten the union nut once again.

Commissioning/start-up

NOTE

The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical components.

  • Do not connect the unit to a dimmable power supply.

Switching on: Connect the unit to the mains. The unit switches on immediately.

Switching off: Disconnect the unit from the mains. The viewing window shows that the UVC lamp in the device is working.

Maintenance and cleaning

NOTE

Do not use aggressive cleaning agents or chemical solutions. These agents can damage the housing, impair the function of the device and harm animals, plants and the environment.

  • If possible, clean the unit with clear water and a soft brush or a sponge; remove stubborn dirt with the aid of the recommended cleaning agents

Clean the unit as required but at least twice per year.

  • When cleaning the pump, pay particular attention to the impeller unit and the pump housing.
  • Clean the inspection window with a cotton bud

Opening/closing the housing
To clean and maintain the filter media, filter pump and UVC clarifier, you must open the device. How to proceed:

  1. Release the clamps on the upper filter shell and remove the upper filter shell from the device.
  2. Remove filter media

Oase-1500-Filtral-UVC-Pump-fig-16

Clean filter media
Prerequisite:

  • Housing is opened. (→ Opening/closing the housing)

How to proceed:

  1. Carefully clean the removed filter media using clean tap water.
  2. Also clean the upper filter shell and the filter subshell carefully with clean tap water.
  3. Reassemble the unit in the reverse order.

Clean filter pump
Prerequisite:

  • Housing is opened. (→ Opening/closing the housing)

How to proceed:

  1. Remove the filter pump and the UVC clarifier from the device.
  2. When doing so, peel off the cable support sleeve on the connection cable from the groove in the filter subshell.
  3. Remove the union nut and pull off the pump.
  4. Rotate the pump cover counter-clockwise and remove.
  5. Pay attention that the seal does not get lost.
  6. Pull the running unit out of the pump.
  7. Clean all components using clean tap water.
  8. Reassemble the unit in the reverse order.
  9. Insert the cable support sleeve on the power supply connection cable into the groove on the filter subshell. (→ Opening/closing the housing)

Oase-1500-Filtral-UVC-Pump-fig-17

Clean UVC clarifier

CAUTION
The ultraviolet radiation of the UVC lamp can damage your eyes and skin.

  • Never operate the UVC lamp outside its housing.
  • Disconnect the unit from the mains before starting maintenance or before replacing the UVC lamp

CAUTION
The quartz glass and UVC lamp could break and result in cuts.

  • Carry out all work on the UVC clarifier carefully to avoid cutting injuries.
  • Avoid vibrations, impacts and hectic movements to prevent the breaking of glass

For safety reasons, the UVC lamp can only be turned on when the UVC clarifier is properly installed into the device.

Prerequisite:

  • Housing is open. (→ Opening/closing the housing)

How to proceed:

  1. Unscrew the nozzle pipe for the purpose of easier handling of the device.
  2. Remove the filter pump and the UVC clarifier from the device.
  3. When doing so, peel off the cable support sleeve on the connection cable from the groove in the filter subshell.
  4. Remove the Union nut and pull off the pump.
  5. Rotate the water housing counter-clockwise until the marking points to the opened lock. Subsequently, carefully remove the water housing from the device head and clean all parts.
  6. Heavy impacts can damage the quartz glass or the UVC lamp underneath.
  7. Check the quartz glass for visible damage.
  8. Clean: Clean the quartz glass from the outside with a damp cloth, and the water housing with clean water and a brush.
  9. After cleaning, carefully slide the device head back onto the water housing.
  10. Pay attention that the big O-ring has been inserted so as to ensure that the housing is watertight.
  11. Rotate the device head clockwise until the marking points to the closed lock.
  12. Put the device back together by completely executing the steps in the reverse order.

Oase-1500-Filtral-UVC-Pump-fig-18

Exchange the UVC lamp

CAUTION
The ultraviolet radiation of the UVC lamp can damage your eyes and skin.

  • Never operate the UVC lamp outside its housing.
  • Disconnect the unit from the mains before starting maintenance or before replacing the UVC lamp

CAUTION
The quartz glass and UVC lamp could break and result in cuts.

  • Carry out all work on the UVC clarifier carefully to avoid cutting injuries.
  • Avoid vibrations, impacts and hectic movements to prevent the breaking of glass
  • For safety reasons, the UVC lamp can only be turned on when the UVC clarifier is properly installed into the device.
  • For optimum filter performance, replace the UVC lamp after approx. 8000 operating hours

Prerequisite:

  • Housing is open. (→ Opening/closing the housing)
  • The water housing of the UVC clarifier is opened.(→ Clean UVC clarifier)

How to proceed

  1. Using a screwdriver, loosen the safety screw securing the union nut on the quartz glass.
  2. Unscrew the union nut counterclockwise, then carefully remove the quartz glass.
  3. Heavy impacts can damage the quartz glass or the UVC lamp underneath.
  4.  Carefully remove the lamp protection from the UVC lamp, then remove the shielding plate from the base and finally pull the UVC lamp out of the base. Replace with a new UVC lamp.
  5.  Only use UVC lamps that correspond with the device’s technical data. (→ Unit data)
  6. After replacing the lamp, reinstall the shielding plate and the lamp protection at their respective positions.
  7. Carefully slide the quartz glass with the union nut and the O-ring onto the UVC lamp.
  8. Pay attention that the O-ring is located between the union nut and the thread on the UVC clarifier, in order that the quartz glass closes watertight.
  9. Tighten the union nut in the clockwise direction as tightly as possible. Then tighten the safety screw on the union nut.
  10. Carefully slide the device head back onto the water housing.
  11. Pay attention that the big O-ring has been inserted so as to ensure that the housing is watertight.
  12. Rotate the device head clockwise until the marking points to the closed lock.
  13. Put the device back together by completely executing the steps in the reverse order.

Oase-1500-Filtral-UVC-Pump-fig-19

Storage/winter protection

The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.
How to correctly store the unit:

  • Thoroughly clean the unit.
  • Check the unit for damage and replace damaged components.
  • Drain the water remaining in the unit, in the hoses, pipes and connections as much as possible.
  • Protect electrical connections from moisture and dirt.
  • Store the pump submerged and in a frost-free environment.
  • Protect open plug connections from moisture and dirt.

Malfunction remedy

Oase-1500-Filtral-UVC-Pump-fig-20-

Technical data

Unit data

Oase-1500-Filtral-UVC-Pump-fig-21

  1. With optionally available Venturi nozzle

Permissible water quality

Wear parts

  • Filter media
  • Impeller unit
  • UVC lamp, quartz glass and O ring for quartz glass

Disposal
NOTE
Do not dispose of this unit with household waste.

  • Dispose of the unit by using the return system provided for this purpose.
  • Dispose of the UVC lamp by using the return system provided for this purpose.
  • Render the unit unusable by cutting the cables.

contact

  • OASE GmbH Tecklenburger Straße 161 48477 Hörstel | Germany
  • + 49 (0) 5454 80-0
  • + 49 (0) 5454 80-9353
  • [email protected] 