830557 0890
2-WIRED VIDEO ENTRY SECURITY SYSTEM
Model;
|
MY-1AD
| (Room station with video monitor)
INSTRUCTIONS
1 NAMES AND FUNCTIONS
MY-1AD
(1) Handset
(2) Chime volume control
(3) Video monitor (4″ CRT)
(4) DOOR RELEASE button
(5) Video monitor button
(6) Contrast switch
(7) Brightness control
Mounting accessories;
Stand & screw (x 2) Screw (x 4)
(for desk use) (for mounting to gang box)
Wood screw (x 4) Wall-mounting bracket
(for mounting to wall surface)
2 SYSTEM FEATURES
MY-1AD is a room master station with built-in video monitor for use with MY-DA video doorstation.
Confirm a caller visually before you answer.
Picture comes on at video monitor right after call button is pressed on video
doorstation.
Employs a 4- inch direct view and flat screen monitor.
Monitor button allows you to see the outside without picking up handset.
*Door release button to activate electric door release.
3 BEFORE YOU INSTALL AND OPERATE THE EQUIPMENT
— Prohibitions and precautions —
Operation
DO NOT HOLD HOOK SWITCH DOWN BY BALL-POINT PEN, ETC. WHILE PICKING UP HANDSET. THE CHIME TONE SOUNDS THRU THE HANDSET RECEIVER ELEMENT AND COULD CAUSE HEARING DAMAGE.
Installation
-
DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES.
When you mount MY-1AD unit in place of existing bell or chime, be sure to disconnect wires from the present transformer. -
DO NOT OPEN THE FRONT COVER OF MY-1AD UNIT WITHOUT FIRST REMOVING PLUG OF POWER SUPPLY FROM AC OUTLET.
The high voltage is loaded on the monitor unit inside. -
Do not drop or hit the unit. This may cause damage to the picture tube.
-
Avoid running the connecting wires through doors, windows or between furniture, which may pinch and disconnect the wires.
-
IMPORTANT —
Use a parallel 2-conductor cable When using existing two wires, strictly observe that the two wires are of the same cable. Do not use any of the following wires, as they will seriously affect the quality of picture and communication.
coaxial cable; two separate and individual wires; *a pair in multi-conductor cable. -
In case noise from power supply line is induced, take terminal on MY-1AD unit to earth ground.
Installation location
- Do not install MY-1AD unit in a place where it is exposed to;
direct sunlight, air conditioner heat, frost, vapor, water, chemicals, *iron dust, etc.
Installation height
Determine MY-1AD installation height so that the center of the video monitor would be at the convenient eye level: adults’ average height minus 100 mm (4″).
Maintenance
- Clean your MY-1AD equipment with a soft cloth dampened with neutral household cleanser. Never use thinner nor lacquer, benzine, etc.
- Do not splash water directly on unit.
NEVER
- DING-DONG
DING-DONG
NEVER
STRAIGHT PAIR CABLE
YES
| NEVER
COAXIAL CABLE
NEVER
TWO SEPARATE WIRES
|
- Adults’ average height minus 100 mm (4″)
4 SYSTEM COMPONENTS
|
MODELS
| DESCRIPTION| QTY
(per system)|
REMARKS
---|---|---|---|---
MY-DA| Video door station, with plastic cover.|
1
| Surface-mounts on single-gang box or wall.
MY-1AD| Room master station with video monitor.|
1
| Surface-mounts on single-gang box or wall (bracket included).
Can be placed on desk, using a stand supplied.
PS-18YB| Power supply adaptor. Modular type, DC 18V.
AC 110-120V, 50/60 Hz.|
1
|
PS-18YC| AC 120V, 50/60 Hz.
PS-18YD| AC 220-240V, 50/60 Hz.
IER-2| Call extension speaker.|
1
|
EL-9S| Electric door release. AC 12V, 0.35A.|
1
|
Note; MY-DA & MY-1AD are available in a set box, together with power supply.
Models: MYS-1ADP(B), MYS-1ADP(C) & MYS-1ADP(D), each with PS-18YB, PS-18YC &
PS-18YD.
5 INSTALLATION
(1) Actual terminal location
MY-1AD BACK VIEW
-
, : Connect to , terminals on MY-DA (non-polarized).
, : Connect to terminals on IER-2. (non-polarized).
, : Connect to electric door release and bell transformer. -
DC output plug with cord approximately 190 cm (6′ · 3″) long.
-
POWER SUPPLY
(2) Wall mounting
To: power supply
- MY-1 AD
- CONNECTING WIRES
- MOUNTING BRACKET
- SINGLE-GANG BOX
- SCREW (x 2)
- POWER SUPPLY CORD
To: power supply
- MY-1 AD
- CONNECTING WIRES
- MOUNTING BRACKET
- WALL/PILLAR
- WOOD SCREW (x 2)
- POWER SUPPLY CORD
(3) Desk-top-use
- CONNECTING WIRES
- STAND
- Place the stand here and fix with the supplied two screws.
Select a location where the MY-1AD unit will not fall or where the cable may cause tripping.
6 WIRING DIAGRAM
- MY-DA VIDEO DOORSTATION
- MY-1AD ROOM STATION
- IER-2 CALL EXTENSION SPEAKER
- Non-polarized
- POWER SUPPLY ADAPTOR
- DC receptacle
- BELL TRANSFORMER (PT-1210N in N. America)
- EL-9S DOOR RELEASE (AC 12V, 0.35A)
NOTES;
For connecting between video door station and MY-1AD, do not use coaxial
cable, or two separate and individual wires or a pair in multi-conductor
cable.
Use only a straight 2-conductor cable.
In case noise from power supply line is induced, take terminal on the MY-1AD
unit to earth ground.
Locate MY-1AD unit within convenient reach of AC outlet. – DC output cord
length: approx. 1.9 m (6′ · 3″).Do not attempt to lengthen the DC output cord.
It will seriously affect the quality of the picture and communication.
7 OPERATIONS
- Receiving a call from doorstation;
(1) Momentarily depress CALL button.
(2) 4-stroke chime sounds and picture appears instantly.
(3) Pick up handset to reply. When the picture shuts off, depress MONITOR
button.
(4) To activate the electric door release, depress and hold DOOR RELEASE
button.
The visitor may open while the buzzing sound is heard.
NOTE:
If you do not reply, the picture shuts off approximately 45 seconds after
chime tone sounds.
- Monitoring the entrance area;
Depress MONITOR button.
The picture appears on the monitor for approximately 2 and half minutes.
Depress MONITOR button again to cancel.
NOTE;
Inside sound will not be heard at the doorstation.
• Adjusting contrast;
LEFT MIDDLE RIGHT
DAY · NIGHT DAY · NIGHT DAY · NIGHT
SOFT MEDIUM STRONG
(BOTTOM VIEW)
Can be adjusted to 3 levels as desired.
At the entrance where it is dark even in the daytime, put the adjustment
switch to the NIGHT position and turn down the brightness.
• Adjusting brightness;
BRIGHT
DARKER BRIGHTER
(BOTTOM VIEW)
Turn the knob counterclock-wise to make the picture brighter.
• Adjusting chime volume;
TONE VOL.
HIGHER
LOWER
The chime call tone can be adjusted from low to high volume according to the room conditions.
8 SPECIFICATIONS
Power source : DC 18V. Use a power supply adaptor PS-18YB, 18YC or 18YD.
Current consumption : 0.9A maximum. 0.15A in standby mode.
Calling : 4-stroke electronic chime
Communication : Simultaneous with handset.
Wiring : Single pair, straight conductors (non-polarized) between video door station and MY-1AD.
Wiring distance :
Diameter|
0.65 mm
|
1.0 mm
---|---|---
Distance|
50 m
|
100 m
AWG|
22 AWG
|
18 AWG
Distance|
165′
|
330′
Video monitor : 4 inch direct view CRT.
Scanning line : 525 lines.
Dimensions : H: 210 mm x W: 186 mm x D: 53.5 mm (8-1/4″ x 7-5/16″ x 2-1/8″)
Weight : Approx. 1.1 kg (2.43 lbs.).
WARRANTY
Aiphone warrants its products to be free from defects of material and
workmanship under normal use and service for a period of one year after
delivery to the ultimate user and will repair free of charge or replace at no
charge, should it become defective upon which examination shall disclose to be
defective and under warranty. Aiphone reserves unto itself the sole right to
make the final decision whether there is a defect in materials and/or
workmanship; and whether or not the product is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to
misuse, neglect, accident, or to use in violation of instructions furnished,
nor extended to units which have been repaired or altered outside of the
factory.
This warranty does not cover batteries or damage caused by batteries used in
connection with the product.
This warranty covers bench repairs only, and any repairs must be made at the
shop or place designated in writing by Aiphone. Aiphone will not be
responsible for any costs incurred involving on site service calls.
Aiphone Co., Ltd., Nagoya, Japan
Aiphone Corporation, Bellevue, Washington, USA
MY-1AD-I(E)0890F Printed in Japan (E)