2.1 SAFETY SIGNS USED IN THE HANDBOOK.
All instructions referring to possible risks to persons are highlighted by the
following symbols: Danger ingeneral . Standard DIN4844-W9. Danger of
electrocution Standard DIN4844-W8 Other instructions in relation to the
functioning of the equipment with which non-compliance could cause physical
damages are highlighted with the warning: ATTENTION
2.2 NAMEPLATE RATINGS (EEC 89/392 P.1.7.4.A).
The information given on the nameplate or other instructions affixed by the
manufacturer to the unit, must be strictly complied with. The content of these
plates can usually be found in this Handbook (Chapter 1.2.).
2.3 LIABILITY.
Failure to comply with the instructions given by the manufacturer in this
Handbook, in relation to the choice, handling, installation, starting and
maintenance of the unit, shall release the manufacturer or distributor from
all liability in respect of accidents suffered by persons or damages caused
to other installations and, in addition, shall entail forfait of the warranty
2.4 STANDARDS.
(*) look table.
3. GENERAL INSTRUCTIONS IN RELATION TO USER SAFETY.
3.1 Safety during operation of the machinery supplied can only be guaranteed
if it is used in accordance with the diagrams shown on page 45
“ILLUSTRATIONS”. It must never exceed the working conditions and limits given
in this Handbook (Chapter 1.2 – Technical Characteristics). Compliance with
the provisions of Safety Standards in force in each country is mandatory.
3.2 Please ensure that the equipment selected is adequate for the use for
which it is intended and that its condition, installation, starting and
subsequent use are correct. See chapter 1 (Technical Characteristics)
3.3 Installation, repair and maintenance operations will be carried out in all
cases with the equipment disconnected from the mains.
3.4 While the equipment is functioning, it cannot be moved or repositioned.
These operations will be carried out at all times with the machine
disconnected.
3.5 Pressing of the electrical on/off or safety elements will not be performed
where there is damp, and special care must be taken for user´s hands to be
dry, and also with footwear and surfaces with which the user is in contact.
3.6 Those elements of the equipment wich, when functioning, are in movement or
which could reach dangerous temperatures, will be protected with cages or
casing which will prevent accidental contact with the same.
3.7 Electricity conductors, or parts which could carry current, will be
suitably insulated. Other metal parts of the equipment will be correctly
earthed.
3.8 Spare parts that may be necessary will be originals from the manufacturer
or those recommended by the manufacturer.
The use of others, or originals rectified by others, are not permitted and
release the manufactured of distributor from all liability.
2.4 STANDARDS.
Our swimming pool electropumps are manufactured in accordance with the
necessary requeriments for safety and health set forth in Community
Directives.
EN 60335-1:2012 + AC:2014, EN 60335-2-41:2003 + A1:2004 + A2:2010,
EN 62233:2008, Directive (2006/95/EC) – LVD, EN 55014-1:2006 + A1:2009 +
A2:2011, EN 55014-2:1997 + AC:1997 + A1:2001 + A2:2008,
EN 61000-3-2:2006 + A1:2009 + A2:2009, EN 61000-3-3:2013, Directive
(2004/108/EC) – EMC
Control module/ Pilots
Start up procedure
2 steps
1. Time setting
2. Filtration and lighting program setting
LED STATUS
Manual mode
Filtration – Lights
Manual Filtration START / STOP
Manual Lighting ON / OFF
Filtration Pump Protection
Automatic calibration overload procedure.
Automatic setting of motor overload. H-POWER auto adjust with the first
startup.
Once confirmed pump will be self-adjusted during the first 8 min.
Overload and reset
Overload possible alarms:
- Pump is not calibrated.
- Pump is blocked.
Jammed impeller protection
Every 23 hours H- POWER will run the pump during 1 sec, to avoid possible
failing in case of long period of inactivity.
External ON / OFF
Filtration
Lights
START
When the contact is closed, the pump will start up.| STOP
When the contact is opened, the pump will be paused.
---|---
ON
When the contact is closed, the lights will turn on.| OFF
When the contact is opened, the lights will turn off.
Temperature Control
Auxiliary contact (AUX LED)
Auxiliary contact relay is activated simultaneously with the pump output.
Potential free relay
Pump operation data download
Bluetooth
( Only modelo – B)
https://www.toscano.es/app_downloader/hayward.html|
https://www.toscano.es/app_downloader/hayward.html
---|---
Specification
Power supply | 230VAC – 50/60Hz |
---|---|
Pump output | 14A, single-phase models 230VAC |
Lighting output (according to the model) | 230VAC / 5A |
12 VAC / 50W
12VAC / 100W
12VAC / 300W
Pilot lights| Filtration ON, Alarm, Time programs, Ligthing program, Auxiliary
output, Current time
Protections| Motor overload
Overload protection| 20% over calibrated current
4-digit LED display| Current time, Settings, Alarms
Auxiliary relay| Free-voltage contact 250V / 5A
Maximum terminal cross-section| 4mm2 (power) / 2.5mm2 (control)
IP/Temperature| IP65/-10º…+55º C
Software| V.5
Directives| – 2016 D.C. 2014 / 30 / CE EMC
D.C. 2014 / 35 / UE C.E. ROHS
EN61558 Light power transformer
Options| Bluetooth interface (-B)
RCCD (- D)
Transformer T50
Transformer T100
Transformer T300
Product orden form
Hayward is a registered trademark
of Hayward Industries, Inc.
© 2018 Hayward Industries, Inc.
Documents / Resources
|
HAYWARD TPM-POOL-B Universal Control
Panel
[pdf] User Guide
TPM-POOL-B Universal Control Panel, TPM-POOL-B, Universal Control Panel,
Control Panel
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>