2.1 SAFETY SIGNS USED IN THE HANDBOOK.
All instructions referring to possible risks to persons are highlighted by the following symbols: Danger ingeneral . Standard DIN4844-W9. Danger of electrocution Standard DIN4844-W8 Other instructions in relation to the functioning of the equipment with which non-compliance could cause physical damages are highlighted with the warning: ATTENTION

2.2 NAMEPLATE RATINGS (EEC 89/392 P.1.7.4.A).
The information given on the nameplate or other instructions affixed by the manufacturer to the unit, must be strictly complied with. The content of these plates can usually be found in this Handbook (Chapter 1.2.).

2.3 LIABILITY.
Failure to comply with the instructions given by the manufacturer in this Handbook, in relation to the choice, handling, installation, starting and maintenance of the unit, shall release the manufacturer or distributor from all liability in respect of accidents  suffered by persons or damages caused to other installations and, in addition, shall entail forfait of the warranty

2.4 STANDARDS.
(*) look table.

3. GENERAL INSTRUCTIONS IN RELATION TO USER SAFETY.
3.1 Safety during operation of the machinery supplied can only be guaranteed if it is used in accordance with the diagrams shown on page 45 “ILLUSTRATIONS”. It must never exceed the working conditions and limits given in this Handbook (Chapter 1.2 –  Technical Characteristics). Compliance with the provisions of Safety Standards in force in each country is mandatory.

3.2 Please ensure that the equipment selected is adequate for the use for which it is intended and that its condition, installation, starting and subsequent use are correct. See chapter 1 (Technical Characteristics)
3.3 Installation, repair and maintenance operations will be carried out in all cases with the equipment disconnected from the mains.
3.4 While the equipment is functioning, it cannot be moved or repositioned. These operations will be carried out at all times with the machine disconnected.
3.5 Pressing of the electrical on/off or safety elements will not be performed where there is damp, and special care must be taken for user´s hands to be dry, and also with footwear and surfaces with which the user is in contact.
3.6 Those elements of the equipment wich, when functioning, are in movement or which could reach dangerous temperatures, will be protected with cages or casing which will prevent accidental contact with the same.
3.7 Electricity conductors, or parts which could carry current, will be suitably insulated. Other metal parts of the equipment will be correctly earthed.
3.8  Spare parts that may be necessary will be originals from the manufacturer or those recommended by the manufacturer.
The use of others, or originals rectified by others, are not permitted and release the manufactured of distributor from all liability.


2.4 STANDARDS.

Our swimming pool electropumps are manufactured in accordance with the necessary requeriments for safety and health set forth in Community Directives.

EN 60335-1:2012 + AC:2014, EN 60335-2-41:2003 + A1:2004 + A2:2010,
EN 62233:2008, Directive (2006/95/EC) – LVD, EN 55014-1:2006 + A1:2009 + A2:2011, EN 55014-2:1997 + AC:1997 + A1:2001 + A2:2008,
EN 61000-3-2:2006 + A1:2009 + A2:2009, EN 61000-3-3:2013, Directive (2004/108/EC) – EMC

Control module/ Pilots

HAYWARD TPM-POOL-B Universal Control Panel - Control
module

Start up procedure

2 steps

HAYWARD TPM-POOL-B Universal Control Panel - Start up
procedure

1. Time setting

HAYWARD TPM-POOL-B Universal Control Panel - Time
setting

2. Filtration and lighting program setting
LED STATUS

HAYWARD TPM-POOL-B Universal Control Panel - Filtration and
lighting

Manual mode

Filtration – Lights

Manual Filtration START / STOP

HAYWARD TPM-POOL-B Universal Control Panel - Manual Filtration
START

Manual Lighting ON / OFF

HAYWARD TPM-POOL-B Universal Control Panel - Manual Lighting
ON

Filtration Pump Protection

Automatic calibration overload procedure.
Automatic setting of motor overload. H-POWER auto adjust with the first startup.

HAYWARD TPM-POOL-B Universal Control Panel - Automatic calibration overload
procedure

Once confirmed pump will be self-adjusted during the first 8 min.

Overload and reset
Overload possible alarms:

  • Pump is not calibrated.
  • Pump is blocked.

HAYWARD TPM-POOL-B Universal Control Panel - Overload possible
alarms

Jammed impeller protection
Every 23 hours H- POWER will run the pump during 1 sec, to avoid possible failing in case of long period of inactivity.

External ON / OFF

Filtration

Lights

START
When the contact is closed, the pump will start up.| STOP
When the contact is opened, the pump will be paused.
---|---
ON
When the contact is closed, the lights will turn on.| OFF
When the contact is opened, the lights will turn off.

HAYWARD TPM-POOL-B Universal Control Panel - External
ON

Temperature Control

HAYWARD TPM-POOL-B Universal Control Panel - Temperature
Control

Auxiliary contact (AUX LED)
Auxiliary contact relay is activated simultaneously with the pump output. Potential free relay

HAYWARD TPM-POOL-B Universal Control Panel - Auxiliary
contact

Pump operation data download

HAYWARD TPM-POOL-B Universal Control Panel - Pump operation data
download

Bluetooth

( Only modelo – B)

https://www.toscano.es/app_downloader/hayward.html| https://www.toscano.es/app_downloader/hayward.html
---|---

HAYWARD TPM-POOL-B Universal Control Panel - Bluetooth

Specification

Power supply 230VAC – 50/60Hz
Pump output 14A, single-phase models 230VAC
Lighting output (according to the model) 230VAC / 5A

12 VAC / 50W
12VAC / 100W
12VAC / 300W
Pilot lights| Filtration ON, Alarm, Time programs, Ligthing program, Auxiliary output, Current time
Protections| Motor overload
Overload protection| 20% over calibrated current
4-digit LED display| Current time, Settings, Alarms
Auxiliary relay| Free-voltage contact 250V / 5A
Maximum terminal cross-section| 4mm2 (power) / 2.5mm2 (control)
IP/Temperature| IP65/-10º…+55º C
Software| V.5
Directives| – 2016 D.C. 2014 / 30 / CE EMC
D.C. 2014 / 35 / UE C.E. ROHS
EN61558 Light power transformer
Options| Bluetooth interface (-B)
RCCD (- D)
Transformer T50
Transformer T100
Transformer T300

Product orden form

HAYWARD TPM-POOL-B Universal Control Panel - Product orden
form

HAYWARD logo

Hayward is a registered trademark
of Hayward Industries, Inc.
© 2018 Hayward Industries, Inc.

Documents / Resources

| HAYWARD TPM-POOL-B Universal Control Panel [pdf] User Guide
TPM-POOL-B Universal Control Panel, TPM-POOL-B, Universal Control Panel, Control Panel
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals