Device: Wave 1

  • Part number AU: QNSW-001X16AU
  • Z-Wave Product type ID: 0x0002
  • Z-Wave Product ID: 0x0083
  • Z-Wave Manufacturer: Shelly Europe
  • Z-Wave Manufacturer ID: 0x0460

READ BEFORE USE
This document contains important technical and safety information about the Device, its safe use, and installation.
CAUTION!
Before beginning the installation, please read carefully and entirely this guide carefully and any other documents accompanying the Device. Failure to follow the installation procedures could lead to malfunction, danger to your health and life, violation of law or refusal of legal and/or commercial guarantee (if any). Allterco Robotics EOOD is not responsible for any loss or damage in case of incorrect installation or improper operation of this Device due to failure to follow the user and safety instructions in this guide.

Terminology

  • Device – In this document, the term “Device” is used to refer to the Shelly Qubino device that is a subject of this guide.
  • Gateway – A Z-Wave® gateway, also referred to as a Z-Wave® controller, Z-Wave® main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is a device that serves as a central hub for a Z-Wave® smart home network. The term “gateway” is used in this document.
  • S button – The Z-Wave® Service button, located on Z-Wave® devices is used for various functions such as adding (inclusion), removing (exclusion), and resetting the device to its factory default settings. The term “S button” is used in this document.
  • Adding/Inclusion – The process of adding a Z-Wave device to a Z-Wave network -gateway. The words included, added, etc. are used in this regard.
  • Removing/Exclusion – The process of removing a Z-Wave device from a Z-Wave network -gateway. The words excluded, removed, etc. are used in this regard.

About Shelly Qubino

Shelly Qubino is a line of innovative microprocessor-managed devices, which allow remote control of electric circuits with a smartphone, tablet, PC, or home automation system. They work on Z-Wave® wireless communication protocol, using a gateway. When the gateway is connected to the internet, you can control Shelly Qubino devices remotely from anywhere. Shelly Qubino devices can be operated in any Z-Wave® network with other Z-Wave® certified devices from other manufacturers. All mains-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network. Devices are designed to work with older generations of Z-Wave® devices and gateways.

About the Device

  • The Device controls the on/off function for one electrical device, e.g., bulb, ceiling fan, IR heater, electrical locks, garage doors, irrigation system, etc. The output contact is potential-free (dry contact), so different power supply loads (up to 16 A) can be connected to the Device. It is compatible with push buttons and switches (default).
  • If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output O (O1) state to the opposite state – on, off, on, etc. If the SW (SW1) is configured as a push-button in the Device settings, each press of the push-button will change the output O (O1) state to the opposite state – on, off, on, etc.

Electrical diagrams (110-240 V AC / 24-48 V DC / 12 V DC)

Connecting to the power grid with a power supply 110-240 V AC (Fig. 1), or 24-48 V DC (Fig. 2), or 12 V DC (Fig. 3).Shelly-Qubino-Wave-1-Z-Wave-Smart-
Switch-with-Potential-Free-Contact-fig- \(1\)

LEGEND Device terminals:

  • N: Neutral terminal

  • L: Live terminal (110-240 V AC)

  • SW (SW1): Input terminal for switch/push-button controlling O (O1)

  • I: Load circuit input terminal

  • O (O1): Output terminal for Load circuit (1)

  • 12V+: 12 V DC positive terminal

  • +: 24 – 48 V DC positive terminal

  • ꓕ: 12 / 24 – 48 V DC ground terminal
    Wires:

  • N: Neutral wire

  • L: Live wire (110-240 V AC)

  • +: 24 – 48 V DC positive wire

  • GND: 12 / 24 – 48 V DC ground wire
    Button:

  • S: S button

Installation instruction

The Device can control a various type of loads (e.g., bulbs) in one electrical circuit up to 3.5 kW / 240 V AC. It can be retrofitted into standard electrical wall boxes, behind power sockets and light switches or other places with limited space.

  • CAUTION! Danger of electrocution. Mounting/installation of the Device to the power grid has to be performed with caution, by a qualified electrician.
  • CAUTION! Danger of electrocution. Every change in the connections has to be done after ensuring there is no voltage present at the Device terminals.
  • CAUTION! Use the Device only with a power grid and appliances that comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the Device may damage it.
  • CAUTION! Do not connect the Device to appliances exceeding the given max. load!
  • CAUTION! Do not shorten the antenna.
  • CAUTION! Connect the Device only in the way shown in these instructions. Any other method could cause damage and/or injury.
  • CAUTION! Do not install the Device where it can get wet.
  • CAUTION! Do not use the Device if it has been damaged!
  • CAUTION! Do not attempt to service or repair the Device yourself!
  • CAUTION! Use only one phase AC circuit. Do not use mixed AC and DC circuits.
  • CAUTION! Before starting the mounting/installation of the Device, check that the breakers are turned off and there is no voltage on their terminals. This can be done with a phase tester or multimeter. When you are sure that there is no voltage, you can proceed to connecting the wires.
  • CAUTION! Do not allow children to play with the push buttons/ switches connected to the Device. Keep the devices for remote control of Shelly Qubino (mobile phones, tablets, PCs) away from children.
  • RECOMMENDATION: Place the antenna as far away as possible from metal elements as they can cause signal interference.
  • RECOMMENDATION: Connect the Device using solid single-core wires with increased insulation heat resistance not less than PVC T105°C (221°F).
  • RECOMMENDATION: For inductive appliances that cause voltage spikes during switching on/off, such as electrical motors, fans, vacuum cleaners and similar ones, RC snubber (0.1 µF / 100 Ω / 1/2 W / 600 VAC) should be connected parallel to the appliance.

Connect the load circuit to the Device I and O terminals.

  • If you are using AC power supply for the Device, connect the Live wire to the Device L terminal, and the Neutral wire to the N terminal as shown on Fig. 1. Connect a switch or a push-button to the Device SW terminal and the Live wire.
  • If you are using 24-48 V DC power supply (Fig. 2), connect the + wire to the + and the GND wire to the Ʇ terminals of the Device.
  • If you are using a stabilized 12 V DC power supply (Fig. 3), connect the + wire to the 12V+ terminal, instead to the + terminal. Connect the switch/push-button to the “SW” terminal and the GND wire.

About Z-Wave®

  • The Z-Wave® protocol is an interoperable, wireless, RF-based communications technology designed specifically for control, monitoring, and status reading applications in residential and light commercial environments. Mature, proven, and broadly deployed, Z-Wave® is by far the world market leader in wireless control, bringing affordable, reliable, and easy-to-use ‘smart’ products to millions of people in every aspect of daily life.
  • Interoperability has always been at the core of the Z-Wave® protocol, alongside features like backward compatibility, security, and reliability. All Z-Wave® devices can be operated in any Z-Wave® network with other Z-Wave® certified devices, regardless of brand or manufacturer.
  • All mains-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network. 4000+ Z-Wave-certified products are backward- and forwards-compatible in the Z-Wave® ecosystem and well over 100 million devices are currently in the market.
  • With over 20 years in the marketplace, Z-Wave® technology has best-in-class security measures to keep your home network smarter and safer.
  • Source: www.z-wavealliance.org, http://www.z-wave.com

Z-Wave® Adding / Removing / Factory reset

Adding the Device to a Z-Wave® network (inclusion)
Note! All Device outputs (O, O1, O2, etc. – depending on the Device type) will turn the load 1s on/1s off /1s on/1s off if the Device is successfully added to/removed from a Z-Wave® network.
Note! In case of Security 2 (S2) adding (inclusion), a dialog will appear asking you to enter the corresponding PIN Code (5 underlined digits) that are written on the Z-Wave® DSK label on the side of the Device and on the Z-Wave® DSK label inserted in the packaging.
IMPORTANT : The PIN Code must not be lost.

SmartStart adding (inclusion)
SmartStart-enabled products can be added to a Z-Wave® network by scanning the Z-Wave® QR Code present on the Device with a gateway providing SmartStart inclusion. No further action is required, and the SmartStart device will be added automatically within 10 minutes of being switched on in the network vicinity.

  1. With the gateway application scan the QR code on the Device label and add the Security 2 (S2) Device Specific Key (DSK) to the provisioning list in the gateway.
  2. Connect the Device to a power supply.
  3. Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave® network.
  4. Adding will be initiated automatically within a few seconds after connecting the Device to a power supply, and the Device will be added to a Z-Wave® network automatically.
  5. The blue LED will be blinking in Mode 2 during the adding process.
  6. The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-Wave® network.

Adding (inclusion) with a switch/push-button

  1. Connect the Device to a power supply.
  2. Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave® network.
  3. Enable add/remove mode on the gateway.
  4. Toggle the switch/push-button connected to any of the SW terminals (SW, SW1, SW2, etc.) 3 times within 3 seconds (this procedure puts the Device in Learn mode*). The Device must receive on/off signal 3 times, which means pressing the momentary switch 3 times, or toggling the switch on and off 3 times.
  5. The blue LED will be blinking in Mode 2 during the adding process.
  6. The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-Wave® network.
    Learn mode – a state that allows the Device to receive network information from the gateway.

Adding (inclusion) with the S button

  1. Connect the Device to a power supply.
  2. Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave® network.
  3. Enable add/remove mode on the gateway.
  4. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue.
  5. Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the Learn mode.
  6. The blue LED will be blinking in Mode 2 during the adding process.
  7. The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-Wave® network.

Note! In Setting mode, the Device has a timeout of 10s before entering again into Normal mode

Removing the Device from a Z-Wave® network (exclusion)
Note! The Device will be removed from your Z-Wave® network, but any custom configuration parameters will not be erased.
Note! All Device outputs (O, O1, O2, etc. – depending on the Device type) will turn the load 1s on/1s off /1s on/1s off if the Device is successfully added to/removed from a Z-Wave® network.

Removing (exclusion) with a switch/push-button

  1. Connect the Device to a power supply.
  2. Check if the green LED is blinking in Mode 1. If so, the Device is added to a Z-Wave® network.
  3. Enable add/remove mode on the gateway.
  4. Toggle the switch/push-button connected to any of the SW terminals (SW, SW1, SW2,…) 3 times within 3 seconds (this procedure puts the Device in Learn mode). The Device must receive on/off signal 3 times, which means pressing the momentary switch 3 times, or toggling the switch on and off 3 times.
  5. The blue LED will be blinking in Mode 2 during the removing process
  6. The blue LED will be blinking in Mode 1 if the Device is successfully removed from a Z-Wave® network

Removing (exclusion) with the S button

  1. Connect the Device to a power supply.
  2. Check if the green LED is blinking in Mode 1. If so, the Device is added to a Z-Wave® network.
  3. Enable add/remove mode on the gateway.
  4. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue.
  5. Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the Learn mode.
  6. The blue LED will be blinking in Mode 2 during the removing process.
  7. The blue LED will be blinking in Mode 1 if the Device is successfully removed from a Z-Wave® network.

Note! In Setting mode, the Device has a timeout of 10s before entering again into Normal mode

Factory reset

Factory reset general
After Factory reset, all custom parameters and stored values (kWh, associations, routings, etc.) will return to their default state. HOME ID and NODE ID assigned to the Device will be deleted. Use this reset procedure only when the gateway is missing or otherwise inoperable.

Factory reset with a switch/push-button
Note! Factory reset with a switch/push-button is only possible within the first minute after the Device is connected to a power supply.

  1. Connect the Device to a power supply.
  2. Toggle the switch/push-button connected to any of the SW terminals (SW, SW1, SW2,…) 5 times within 3 seconds. The Device must receive on/off signal 5 times, which means pressing the push-button 5 times, or toggling the switch on and off 5 times.
  3. During factory reset, the LED will turn solid green for about 1s, then the blue and red LED will start blinking in Mode 3 for approx. 2s.
  4. The blue LED will be blinking in Mode 1 if the Factory reset is successful

Factory reset with the S button
Note! Factory reset with the S button is possible anytime.

  1. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue.
  2. Press the S button multiple times until the LED turns solid red.
  3. Press and hold (> 2s) S button on the Device until the red LED starts blinking in Mode 3. Releasing the S button will start the factory reset.
  4. During factory reset, the LED will turn solid green for about 1s, then the blue and red LED will start blinking in Mode 3 for approx. 2s.
  5. The blue LED will be blinking in Mode 1 if the Factory reset is successful.

Remote factory reset with parameter with the gateway
Factory reset can be done remotely with the settings in Parameter No. 120.

Z-Wave® Security 2 and Device Specific Key (DSK)

The Device supports the latest Security 2 (S2) feature. S2 is handled by the
strong AES 128 Encryption protocol, which means that the S2 makes Z-Wave® the most secure IoT (Internet of Things) security platform out there. To fully utilize the product and its Security 2 feature, a Security 2-enabled Z-Wave® gateway must be used.

Authenticated Control

  • Out-Of-Band DSK for adding (inclusion)
  • May be used by most implementations

The Device also supports Security 2 Authenticated, Unauthenticated, and Unsecure adding (inclusion).
Note! When adding the Device to a Z-Wave network with a gateway supporting Security 2 (S2), the PIN Code of the Z-Wave Device Specific Key (DSK) is required. You can find it on the label on the side of the Device and a copy is inserted in the packaging, which must not be lost. Do not remove the Z-Wave DSK label from the Device. As a backup measure, use the label in the packaging.Shelly-Qubino-Wave-1-Z-Wave-Smart-Switch-with-Potential-Free-
Contact-fig- \(2\).
The first five digits of the key are highlighted or underlined to help the user identify the PIN Code part of the DSK text. The DSK is additionally represented with a QR Code as shown on the image.

DSK label and QR code (example)

  • A joining node requesting to join the S2 Access Control Class or the S2 Authenticated Class will obfuscate its Public Key by setting the bytes 1..2 to zeros (0x00) before transferring its key via RF.
  • The DSK may be used for out-of-band (OOB) authentication.
  • The including gateway may use a QR code scanning device to read the entire DSK of the joining device and match it with the obfuscated public key received via RF from the joining device

NOTE : This Device must be used in conjunction with a Security Enabled Z-Wave gateway to fully utilize all implemented functions.
NOTE : This Device is a security enabled Z-Wave Plus® product that can use encrypted Z-Wave Plus® messages to communicate to other security enabled Z-Wave Plus® products.
NOTE : DSK access via UI gateways, which implement the S2 and SmartStart security feature, display an input dialog box, with a full or partial DSK key. Most of them display a partial DSK (they do not show the PIN code) when the Device is added (included) with the S2-Authenticated security scheme. When added (included) with the S2-Unauthenticated, some gateways show the complete DSK while others perform the complete adding (inclusion) process without prompting the user with the dialogue.

LED Signalisation

General rules

  • Switching between Normal and Settings mode is done by pressing the S button once.
  • Solid LED means that you are in Setting mode (this does not apply to plugs). Once you are in Setting mode, it automatically switches to Normal mode after 10s.
  • If the LED is not in Alarm mode, it will turn off after a timeout of 30 min (this does not apply to plugs). Press on the S button or Device power cycle wakes the LED up for 30 min.

Normal mode LED status: Normal mode is defined by a stable device function that can last infinitely long.

Shelly-Qubino-Wave-1-Z-Wave-Smart-Switch-with-Potential-Free-Contact-fig-
\(3\) Shelly-Qubino-
Wave-1-Z-Wave-Smart-Switch-with-Potential-Free-Contact-fig-
\(4\).

Z-Wave® Parameters

Parameter No. 1 – SW (SW1) Switch type
This parameter defines how the Device should treat the switch (which type) connected to the SW (SW1) terminal.
Value size: 1 Byte
Default value: 2

Values & descriptions:

  • 0 – momentary switch,
  • 1 – toggle switch (contact closed – ON / contact opened – OFF),
  • 2 – toggle switch (Device changes status when switch changes status)

Parameter No. 17 – Restore state of O (O1) after power failure
This parameter determines if the on/off status is saved and restored for the load connected to O (O1) after a power failure.

  • Values size: 1 Byte
  • Default value: 0

Values & descriptions:

  • 0 – Device saves last on/off status and restores it after a power failure
  • 1 – Device does not save on/off status and does not restore it after a power failure, it remains off

Parameter No. 19 – O (O1) Auto OFF with timer
If the load O (O1) is ON, you can schedule it to turn OFF automatically after the period of time defined in this parameter. The timer resets to zero each time the Device receives an ON command, either remotely (from the gateway or associated device) or locally from the switch.

  • Values size: 2 Byte
  • Default value: 0

Values & their descriptions:
0 – Auto OFF Disabled

  • 1 – 32535 = 1 – 32535 seconds (or milliseconds – see Parameter no. 25. Auto OFF timer enabled for a given amount of seconds (or milliseconds) resolution 100ms

Parameter No. 20 – O (O1) Auto ON with timer
If the load O (O1) is OFF, you can schedule it to turn ON automatically after the period of time defined in this parameter. The timer resets to zero each time the Device receives an OFF command, either remotely (from the gateway or associated device) or locally from the switch.

  • Values size: 2 Byte
  • Default value: 0

Values & their descriptions:

  • 0 – Auto ON Disabled
  • 1 – 32535 = 1 – 32535 seconds (or milliseconds – see Parameter No. 25. Auto ON timer enabled for a given amount of seconds (or milliseconds) resolution 100ms

Parameter No. 23 – O (O1) contact type – NO/NC
The set value determines the relay contact type for output O (O1) . The relay contact type can be normally open (NO) or normally closed (NC).

  • Values size: 1 Byte
  • Default value: 0

Values & descriptions:

  • 0 – NO
  • 1 – NC

Relay logic:

Par-NO/NC Command (switch, Z-Wave,..) Device output state
NO (0) OFF OFF (0 V)
NO (0) ON ON (230 V)
NC (1) OFF ON (230 V)
NC (1) ON OFF (0 V)

Parameter No. 25 – Set timer units to s or ms for O (O1) Set the timer units to seconds or milliseconds. Choose if you want to set the timer in seconds or milliseconds in Parameters No. 19, 20.

  • Values size: 1 Byte
  • Default value: 0

Values & descriptions:

  • 0 – timer set in seconds
  • 1 – timer set in milliseconds

Parameter No. 91 – Water Alarm
This parameter determines which alarm frames the Device should respond to and how. The parameters consist of 4 bytes, the three most significant bytes are set according to the official Z-Wave protocol specification.

  • Values size: 4 Byte
  • Default value: 0

Values & descriptions:

  • 0 no action
  • 1 open relay
  • 2 close relay

Parameter No. 92 – Smoke Alarm This parameter determines which alarm frames the Device should respond to and how. The parameters consist of 4 bytes, the three most significant bytes are set according to the official Z-Wave protocol specification.

  • Values size: 4 Byte
  • Default value: 0

Values & descriptions:

  • 0 no action
  • 1 open relay
  • 2 close relay

Parameter No. 93 – CO Alarm This parameter determines which alarm frames the Device should respond to and how. The parameters consist of 4 bytes, the three most significant bytes are set according to the official Z-Wave protocol specification.

Values size: 4 Byte
Default value: 0

Values & descriptions:

  • 0 no action
  • 1 open relay
  • 2 close relay

Parameter No. 94 – Heat Alarm This parameter determines which alarm frames the Device should respond to and how. The parameters consist of 4 bytes, the three most significant bytes are set according to the official Z-Wave protocol specification.

  • Values size: 4 Byte
  • Default value: 0

Values & descriptions:

  • 0 no action
  • 1 open relay
  • 2 close relay

Parameter No. 120 – Factory Reset
Reset to factory default settings and removed from the Z-Wave network.
The parameter is Advanced and may be hidden under the Advanced tag.

  • Values size: 1 Byte
  • Default value: 0

Values & descriptions:

  • 0 – Don’t do Factory reset
  • 1 – Do the Factory reset

Parameter No. 201 – Serial Number 1
This parameter contains a part of device’s serial number.
The parameter is Read-Only and cannot be changed. The parameter is Advanced and may be hidden under the Advanced tag.

  • Values size: 4 Byte
  • Default value: Device specific

Values & descriptions:

0x00000000 – 0x7FFFFFFF Parameter No. 202 – Serial Number 2
This parameter contains a part of device’s serial number.
The parameter is Read-Only and cannot be changed. The parameter is Advanced and may be hidden under the Advanced tag.

  • Values size: 4 Byte
  • Default value: Device specific

Values & descriptions:

  • 0x00000000 – 0x7FFFFFFF

Parameter No. 203 – Serial Number 3

This parameter contains a part of device’s serial number.
The parameter is Read-Only and cannot be changed. The parameter is Advanced and may be hidden under the Advanced tag.

  • Values size: 4 Byte
  • Default value: Device specific

Values & descriptions:

  • 0x00000000 – 0x7FFFFFFF

Command Class

  1. ASSOCIATION_V2 [S0, S2]*
  2. ASSOCIATION_GRP_INFO_V3 [S0, S2]*
  3. BASIC_V2 [S0, S2]*
  4. SWITCH_BINARY_V2 [S0, S2]*
  5. CONFIGURATION_V4 [S0, S2]*
  6. DEVICE_RESET_LOCALLY_V1 [S0, S2]*
  7. FIRMWARE_UPDATE_MD_V5 [S0, S2]*
  8. INDICATOR_V3 [S0, S2]*
  9. MANUFACTURER_SPECIFIC_V2 [S0, S2]*
  10. MULTI_CHANNEL_ASSOCIATION_V3 [S0, S2]*
  11. NOTIFICATION_V8 [S0, S2]*
  12. POWERLEVEL_V1 [S0, S2]*
  13. SECURITY_V1
  14. SECURITY_2_V1
  15. SUPERVISION_V1
  16. TRANSPORT_SERVICE_V2
  17. VERSION_V3 [S0, S2]*
  18. ZWAVEPLUS_INFO_V2

[S2] Security S2 Command Class

NOTE : MAPPING OF COMMAND_CLASS_BASIC

Supporting Command Class Basic
COMMAND_CLASS_BASIC is mapped into COMMAND_CLASS_SWITCH_BINARY, for enabling Switch (O) control:

Switch (O) will be turned ON or OFF, after receiving the BASIC_SET command:

Basic Command received Mapped Command (binary Switch)
Basic Set (0xFF) Switch binary Switch (0xFF)
Basic Set (0x00) Switch binary Switch (0x00)
Basic GET Basic Report (Current Value, Target Value)

Supporting Command Class Indicator

The Device supports the Command Class Indicator V3 (ID 0x50). When the Device receives an indicator set, the LED blinks according to the received indicator set.
Refer to the LED Signalization chapter

Notifications Command class

Overheat detected

Z-Wave Notification Type Name| Z-Wave Notification Name| LED colour status| Device reaction| ****

Action to restore

| Device specific| Z-Wave definition
---|---|---|---|---|---|---





Heat Alarm

| ****



Overheat detected

| ****


Check the RGB LED

signalization table

| ****


Switch OFF all outputs and send a notification

| Any of the following activities reset this alarm: power cycle, , short press on the S button, press on any switch/push-button connected to any SW (SW, SW1, SW2, …)

terminal.

| ****




YES

| notification type=heat alarm Value=0x04, event=State Notificatio name=Overheat detected Value=0x02, Version=V2

Associations

Associations are used for direct communication between the Device and other devices within your Z-Wave network without the need of the Z-Wave gateway.
Max. number of associated devices per group is 9. This value is fixed and can not be configured. Each association group supports the association of up to 9 devices (nodes). To avoid network delays, we recommend limiting the amount of associated devices to no more than 5 per group. “Lifeline Group” is reserved solely for a gateway and hence only 1 node can be assigned.

Device| Endpoint| Group| triggered by| reporting to| Command classes
---|---|---|---|---|---

Wave 1

|

Root device

|

Group 1 (Lifeline)

|

Device

|

GW

| ·         INDICATOR_REPORT : LED status

·         DEVICE_RESET_LOCALLY_NOTIFICATION : triggered upon request

·         SWITCH_BINARY_REPORT : status change report for output O (O1)

·         NOTIFICATION_REPORT : triggered on Overheat detected

Wave 1| Root device| Group 2 (On/Off)|

SW

| Associated device| ·         BASIC_SET : set On / Off state at the associated device

Wave 1

|

Root device

|

Group 3 (Start/Stop set level)

|

SW

|

Associated device

| ·         SWITCH_MULTILEVEL_START_LEVEL_CHANGE

: initiate a transition to a new level

·         SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE

: stop an ongoing transition

Supported load types

  • Resistive (incandescent bulbs, heating devices)
  • Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
  • Capacitive (capacitor banks, electronic equipment, motor start capacitors)

Technical Specifications


Power supply

| 110-240 V AC / 24-48 V DC /

12 V DC ± 10%

---|---
Power consumption| < 0.3 W
Max. switching voltage AC| 240 V
Max. switching current AC| 16 A
Max. switching voltage DC| 30 V
Max. switching current DC| 10 A
Overheating protection| Yes


Distance

| Up to 40 m indoors (131 ft.) (depends on local condition)
Z-Wave® repeater:| Yes
CPU| Z-Wave® S800
Z-Wave® frequency bands:| 919,8MHz
Maximum radio frequency power transmitted in frequency band(s)| ****

< 25 mW


Size (H x W x D)

| 37x42x16 ±0.5 mm /

1.46×1.65×0.63 ±0.02 in

Weight| 26 g / 0.92 oz.
Mounting| Wall console
Screw terminals max. torque| 0.4 Nm / 3.5 lbin
Conductor cross section| 0.5 to 1.5 mm² / 20 to 16 AWG
Conductor stripped length| 5 to 6 mm / 0.20 to 0.24 in
---|---
Shell material| Plastic
Color| Blue
Ambient temperature| -20°C to 40°C / -5°F to 105°F
Humidity| 30% to 70% RH
Max. altitude| 2000m / 6562 ft.

Important disclaimer

Z-Wave® wireless communication may not always be 100% reliable. This Device should not be used in situations in which life and/or valuables are solely dependent on its functioning. If the Device is not recognized by your gateway or appears incorrectly, you may need to change the Device type manually and ensure that your gateway supports Z-Wave Plus® multi-level devices.

Declaration of Conformity

Hereby, Allterco Robotics EOOD declares that the radio equipment type Wave 1 is in compliance with Directive 2014/53/ EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. The full text of the EU Declaration of conformity is available at the following internet address: https://shelly.link/Wave1-DoC

Manufacturer