Welcome to the world of Philips Lumea Prestige! You are only a few weeks away from silky-smooth skin. Lumea Prestige uses Intense Pulsed Light (IPL) technology, known as one of the most effective methods to continuously prevent hair growth. In close collaboration with expert scientists and dermatologists, we adapted this light-based technology, originally used in professional beauty salons, for easy and effective use in the comfort of your home. Lumea Prestige is gentle and offers convenient and effective treatment at a light intensity that you find comfortable. Unwanted hairs are finally a thing of the past. Lumea Prestige has been designed and developed for women, but may be suitable for use by men.
To fully benefit from the support that Philips offers, register your product at www.philips.com/support. For further information, please go to www.philips.com/Lumea to find our experts’ advice, tutorial videos and FAQs and make the most of your Lumea.

Suitable skin tones

Suitable body hair colors

Device overview

Philips-BRI940-Lumea-IPL-8000-Series-8000-Hair-Removal- Device-
FIG-1

  1. Light exit window with integrated UV filter
  2. Attachments
  3. Body attachment
  4. Underarm attachment (BRI946, BRI947, BRI948)
  5. Bikini attachment (BRI946, BRI947, BRI948)
  6. Facial attachment (BRI944, BRI945, BRI946, BRI947, BRI948)
  7. SmartSkin sensor
  8. Integrated safety system
  9. The reflector inside the attachment
  10. Electronic contacts
  11. Opening for electronic contacts
  12. Flash button
  13. On/off button
  14. Confirmation button
  15. Toggle buttons
  16. Intensity lights
  17. SmartSkin button
  18. ‘READY to flash’ light
  19. Air vents
  20. Device socket
  21. Adapter
  22. Small plug
  23. Pouch (not shown)
  24. Cleaning cloth (not shown)

Contraindications

Conditions

Never use the device:

  • If you are under the age of 18 years or above 65 years.
  • If you have skin type VI (you rarely to never sunburn, very dark tanning). In this case you run a high risk of developing skin reactions, such as hyperpigmentation and hypopigmentation, strong redness or burns.
  • If you are pregnant or breastfeeding as the device was not tested on pregnant or breastfeeding women.
  • If you have any active implants such as a pacemaker, neurostimulator, insulin pump, etc.

Medications/History
Never use the device if you take any of the medications listed below

  • If your skin is currently being treated with or has recently been treated in the past week with Alpha-Hydroxy Acids (AHAs), Beta-Hydroxy Acids (BHAs), topical tretinoin and azelaic acid.
  • If you have taken any form of isotretinoin Accutane or Roaccutane in the last six months. This treatment can make skin more susceptible to tears, wounds and irritations.
  • If you are taking photosensitizing agents or medications, check the package insert of your medicine and never use the device if it is stated that it can cause photo-allergic reactions, photo-toxic reactions or if you have to avoid sun when taking this medicine.
  • If you take anticoagulation medications, including heavy use of aspirin, in a manner which does not allow for a minimum 1-week washout period prior to each treatment.

Never use the device:

  • If you have received radiation therapy or chemotherapy within the past 3 months.
  • If you are on painkillers which reduce the skin’s sensitivity to heat.
  • If you take immunosuppressive medications.

Pathologies/Disorders

Never use the device:

  • If you have diabetes or other systemic or metabolic diseases.
  • If you have congestive heart disease.
  • If you have a disease related to photosensitivity, such as polymorphic light eruption (PMLE), solar urticaria, porphyria, etc.
  • If you have a history of collagen disorder, including a history of keloid scar formation or a history of poor wound healing.
  • If you have epilepsy with flashlight sensitivity.
  • If your skin is sensitive to light and easily develops a rash or an allergic reaction.
  • If you have a skin disease such as active skin cancer, you have a history of skin cancer or any other localized cancer in the areas to be treated.
  • If you have a history of vascular disorder, such as the presence of varicose veins or vascular ectasia in the areas to be treated.
  • If you have any bleeding disorder.
  • If you have a history of immunosuppressive disease (including HIV infection or AIDS).
  • If you have a skin pigmentation disorder such as vitiligo.

Skin conditions

Never use the device:

  • If you have infections, eczema, burns, inflammation of hair follicles, open lacerations, abrasions, herpes simplex (cold sores), wounds or lesions and haematomas (bruises) in the areas to be treated.
  • On irritated (red or cut), sunburned, recently tanned or fake‑tanned skin.
  • On the following areas: on moles, freckles, large veins, darker pigmented areas, scars, skin anomalies without consulting your doctor. This can result in a burn and a change in skin color, which makes it potentially harder to identify skin-related diseases.
  • On the following areas: warts, tattoos or permanent make‑up.

Location/Areas

Never use the device on the following areas:

  • Around the eyes and on or near the eyebrows. Use the device only below the cheekbones.
  • On the lips, scalp, perineum, nipples, areolas, labia minora, vagina, anus and the inside of the nostrils and ears.
  • If you have had surgery in the areas to be treated.
  • Men must not use the device on the face and neck including all beard-growing areas, nor on the whole genital area.
  • On areas where you use long-lasting deodorants. This can result in skin reactions.
  • Over or near anything artificial like silicone implants, subcutaneous injection ports (insulin dispenser) or piercings.

Important safety instructions

Warnings

Please read and follow these instructions to optimize the use of the device and prevent/minimize the risk of injury, skin reactions and side effects.

  • Before you use Lumea, you should clean your skin and make sure it is hair‑free, entirely dry and free from any lotion or gel.
  • Keep the device and the adapter dry.
  • The device is not washable. Never immerse the device in water and do not rinse it under the tap.
  • Water and electricity are a dangerous combination. Do not use this appliance in wet surroundings (e.g. near a filled bath, a running shower or a filled swimming pool). Moisture can damage the device and lead to a potential safety hazard.
  • Always check the device before you use it. Do not use the device or adapter if it is damaged. Always replace a damaged part with one of the original type.
  • If the device or adapter is broken or damaged, do not touch any inner part to avoid electric shock.
  • Do not use the device if the UV filter of the light exit window and/or attachment is broken, as safe operation cannot be guaranteed under these circumstances.
  • Do not attempt to open or repair your device. Opening Philips Lumea may expose you to dangerous electrical components and to pulsed light energy, either of which may cause bodily and/or eye injury.
  • Always return the device to a service center authorized by Philips for examination or repair. Repair by unqualified people could cause an extremely hazardous situation for the user.
  • No modification of this equipment is allowed. Do not modify, override or cut off any part of the device (e.g. adapter or the cord), as this causes a hazardous situation.
  • Do not look at the flash while using the device. Use the device in a well-lit room so that the light is less glaring to your eyes. While not necessary for safety, you may wear sunglasses or goggles for your convenience if you find the light uncomfortable or too bright.
  • Do not flash the same spot multiple times during a treatment. The surface of the attachment should overlap the previous spot to make sure you flash the complete skin area, but treating the same area multiple times does not increase efficacy.
  • For hygienic reasons, the device should only be used by one person.
  • Do not use hair removal creams in the area (to be) treated with the device, as chemicals may cause skin reactions.
  • Do not use any pencil or pen to mark the areas to be treated. This may cause burns on your skin.
  • The device can be stored at a temperature between -25 °C and 70 °C. Use the device at a temperature between 5 °C and 35 °C. The device will not work properly outside of this temperature range. This may cause burns on your skin.
  • Hair removal by intense pulsed light sources can cause increased hair growth in some individuals. Based upon currently available data, the highest risk groups for this response are females of Mediterranean, Middle Eastern, and South Asian heritage treated on the face and neck.
  • If you experience skin irritation or skin redness after treatment, wait until it disappears before applying any product to your skin. If you experience skin irritation after applying a product to your skin, wash it off with water. If you still get skin reactions, stop using the device and consult your doctor.
  • If shaving, epilating or waxing causes skin irritation, we advise you not to use the device until the skin irritation has disappeared.
  • This device is not intended for use by persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the device by a person responsible for their safety.
  •  Children should be supervised to ensure that they do not play with the device. Supervision is required to avoid potential risks such as exposure to the light output, electrocution, strangulation from the cables or choking on the attachments.
  • Tanning with natural or artificial sunlight might influence the sensitivity and color of your skin. Perform a skin test to determine the appropriate light intensity setting.
  • After each treatment, wait at least 48 hours before tanning to ensure any skin reaction has been resolved.
  • If you notice a skin tone change since the last treatment, we advise you to perform a skin test and to wait 24 hours before your next treatment.
  • Always check the device before you use it. Make sure that the SmartSkin sensor window is clean when using the device, to avoid improper operation (see ‘D Clean & store after treatment’).
  • The adapter, light exit window and the filter of the attachments can become very hot (>210 °C) during usage. Always let the adapter, the light exit window as well as the glass filter and inner parts of the attachments cool down before you touch them.
  • This device has a detachable power supply unit. Only use the adapter provided with this device. Do not use an extension cord. The reference number (AD2069x20020HF) can be found on your device. The ‘x’ in this number refers to the plug type for your country.
  • Follow the recommended treatment schedule. Increasing the frequency, especially in the initial phase, can increase the risk of skin reactions.

How IPL works

  1. With Intense Pulsed Light technology, gentle pulses of light are applied to the skin and absorbed by the hair root. The lighter the skin and the darker the hair, the better the pulses of light are absorbed.
  2. The pulses of light stimulate the hair follicle to go into a resting phase. As a consequence, the hair sheds naturally and hair growth is prevented.
  3. The cycle of hair growth consists of different phases. IPL technology is only effective when the hair is in its growing phase. Not all hairs are in the growing phase at the same time. This is why we recommend you to follow the initial treatment phase (4 treatments, every treatment 2 weeks apart) and then the follow‑up treatment phase (touch‑ups every 4 weeks) to make sure all hairs are effectively treated in the growing phase.

Tip: To ensure long-lasting hair removal, touch-ups every 4 weeks are recommended.

Philips-BRI940-Lumea-IPL-8000-Series-8000-Hair-Removal- Device-
FIG-9

Suitable body hair colours

Treatment with Lumea is not effective if you have light blond, grey, red or white hairs as hairs with these colors do not absorb enough light.

Note: T o check if your body hair color allows usage of the device, consult the hair color table on the foldout page.

Recommended treatment schedule

Initial phase

To achieve effective hair reduction, follow the initial treatment schedule.
treatment schedule
For the first 4 treatments, use Lumea once every 2 weeks to ensure that all hairs are treated.

  • Perform a treatment within 3 days before or after the planned treatment date.
  • If you have not treated yourself within 3 days before or after the planned treatment date, restart the initial phase. Plan in 4 treatments, 1 treatment every 2 weeks.

Note : If you do not restart the initial phase, you may not see effective hair reduction.

Note : Replacing one of the IPL treatments with another hair removal method (waxing, epilating, etc.) will not help to reach the desired hair reduction.
If you want to remove hairs in between the Lumea treatments, you can use your normal hair removal method (excluding hair removal creams)

Touch-up phase

After the initial phase (4 treatments), we recommend touch-ups every 4 weeks.

Touch-up treatment schedule

Perform a treatment every 4 weeks. Repeat this 8 times to achieve effective hair reduction. This is to maintain results and enjoy smooth skin for months.

  • We advise you to perform a treatment within 4 days before or after the planned treatment date.
  • The results may vary based on your individual hair growth and also across different body areas.
  • If you have completed the touch-up phase and you see the need to continue treatment (hair starts coming back), we advise you to restart the initial phase.

Note : Using the device more often does not enhance the effectiveness.

Tip: Mark the treatment schedule on your calendar to remind yourself of the planned treatments.

What to expect

After initial phase

  • After the first treatment, it can take 1 to 2 weeks for the hair to fall out. In the first weeks following the initial treatments, you still see some hairs growing. These are likely to be hairs that were not in their growing phase during the first treatments.
  • After 2-3 treatments, you should see a noticeable reduction in hair growth. However, to effectively treat all hairs, it is important to keep on treating them according to the recommended treatment schedule.
  • After 4 treatments, you should see a significant reduction of hair growth in the areas that you treated with Lumea. A reduction of hair density should be visible as well.

During touch-up phase

  • Keep on treating with frequent touch-ups (every 4 weeks) to maintain the result.

How to use your Lumea Prestige
Remove hair & clean your skin

  1. Remove hair before every treatment as long as the hair is still visible. You can either shave, epilate or wax. Make sure you start to treat before new hair is visible on your skin. If you choose to wax, wait 24 hours before you use LumeaPhilips-BRI940-Lumea-IPL-8000-Series-8000-Hair-Removal- Device-FIG-12
  2. Clean and dry your skin. Make sure that it is free from any lotion or gel.

Test skin 24 hours before treatment

  1. est your skin to find the correct light setting:
  2. For every new body area.
  3. After recent tanning.
  4. Select the correct attachment to test your skin (see ‘Attachments’).
  5. Press the on/off button to turn on the device.Philips-BRI940-Lumea-IPL-8000-Series-8000-Hair-Removal- Device-FIG-15
  6. Choose an area for your skin test.
  7. Press the device firmly onto your skin and hold it in place.The integrated safety system prevents unintentional flashing without full skin contact.
  8. Confirm that the ‘READY to flash’ light lights up white to ensure that there is full contact with your skin.
  9. If the ‘READY to flash’ light is orange, your skin is too dark to treat. Try Lumea on a lighter body area.
  10. Try each setting on your skin and find your comfortable setting. If the flash feels uncomfortable and you experience pain, lower the setting.
  11. When the ‘READY to flash’ light is white, press the flash button on the handle once, to treat one spot with setting ➀Philips-BRI940-Lumea-IPL-8000-Series-8000-Hair-Removal- Device-FIG-16

You will see a flash of light

Note: You can toggle through the light intensity settings by pressing the toggle button.

  • Move to next area. Treat one spot with setting ➁

  • Move to the next area. Treat one spot with setting ➂

  • Move to the next area. Treat one spot with setting ➃

  •  Move to next area. Treat one spot with setting ➄

Wait 24 hours.
Note : Even though you found your comfortable setting during the skin test,0 it may occur that skin reactions show within 24 hours after usage

Check your skin for any reactions (e.g. redness, irritation, rash). If there are no skin reactions after 24 hours, start the treatment with the highest comfortable setting. If the highest comfortable setting resulted in a skin reaction, choose a lower setting that did not result in any skin reactions. If you did not test a lower setting, repeat the skin test.

Treatment

IMPORTANT : First finish sections A (Remove hair & clean your skin) and B (Test skin 24 hours before treatment).

  1. Connect the power adapter to the device and plug into a power outlet.
  2. Press the on/off button to turn on the device.
  3. Choose the setting you selected after the skin test (section B, step 9).
  4. Press the device firmly onto your skin and hold it in place. The ‘READY to flash’ light should light up white.
  5. Press the flash button to release a flash on your skin. The flash treats the skin in that spot. The device makes a soft popping sound. The flash gives you a warm sensation. After each flash, it takes up to 3.5 seconds until the device is ready to flash again. You can release a flash when the ‘READY to flash’ light lights up white.
  6. Move to an adjacent spot and press the flash button again. The surface of the attachment that is in contact with your skin is slightly larger than the light exit window. The surface of the attachment should overlap the previous spot to make sure you flash the complete skin area. DO NOT flash the same spot multiple times during a treatment. The surface of the attachment should overlap the previous spot to make sure you flash the complete skin area, but treating the same area multiple times does not increase efficacy
  7. Continue until you have treated the full area. There are two treatment modes (see ‘Two treatment modes: Stamp & Flash and Slide & Flash’).
  8. Turn off the device when you finish the treatment.
  9. Remove hair before every next treatment, as long as the hair is still visible.

Note: Do not try the device on difficult or sensitive areas (ankle and bony area).

Clean & store after treatment

  1. Unplug the device from the power outlet.
  2. Let the device cool down.
  3. Moisten the soft cloth supplied with a few drops of waterPhilips-BRI940-Lumea-IPL-8000-Series-8000-Hair-Removal- Device-FIG-41
  4. Take the attachment off the device
  5. Clean the light exit window of the device
  6. Clean all surfaces of the attachment, including the metal reflector and window of the attachment (parts B, C, D, E).
  7. Let all parts dry thoroughly.
  8. Store in a dust-free place at room temperature.

Learning more about your Lumea Prestige

Attachments

For optimal results, it is important to use the correct attachment intended for the specific body area you want to treat. Lumea offers full‑body treatment with several attachments designed for use on specific body areas. SenseIQ technology adapts the treatment program when a different attachment is connected.

Note: T he device may not work anymore and show an error when there is dirt on the attachment connector. Clean the contact leads when this occurs.

  1. To place the attachment, simply snap it onto the light exit window.
  2. To remove the attachment, pull it off the light exit window.

Body attachment

The body attachment has the largest treatment window and a curved-in design to effectively cover and treat areas below the neckline, especially large areas such as legs, arms and stomach.

Facial attachment (BRI944, BRI945, BRI946, BRI947, BRI948)

The facial attachment has a precise flat design with extra integrated red glass filter for safe and precise treatment on the sensitive skin above the upper lip, chin and sideburns. The device is only intended for removing unwanted body hair from areas below the cheekbones. When you use the device on areas with sharp contours like the jawline and chin, it may be difficult to establish full skin contact and release a flash.

Tip: Place your tongue between your upper lip and your teeth or puff out your cheeks to make the treatment easier.

Underarm attachment (BRI946, BRI947, BRI948)

The underarm attachment has a specifically curved-out design to treat underarm hairs that might be hard to reach.

Philips-BRI940-Lumea-IPL-8000-Series-8000-Hair-Removal- Device-
FIG-29

Bikini attachment (BRI946, BRI947, BRI948)

The bikini attachment has a specialized design for effective treatment of the bikini area. It has a curved-out design and has a higher light intensity compared to body attachment. Hair in this area tends to be thicker and stronger than leg hair.

SmartSkin sensor

Lumea offers SenseIQ technology for a personalized hair removal treatment. The integrated SmartSkin sensor measures the skin tone at the start of each session and during the session. This provides two features:

  1. The SmartSkin sensor prevents you from treating areas of your skin that are too dark: if it detects a skin tone that is too dark for treatment with Lumea, the ‘READY to flash’ light starts blinking orange. It does not flash when you press the flash button. The device automatically disables. This prevents you from developing skin reactions.
  2. The SmartSkin sensor will help you to select the light intensity setting that is comfortable for your skin. For this, you can use the SmartSkin button.

Selecting the light intensity

Lumea provides 5 different light intensities, you will always be able to change to a light intensity setting you find comfortable.

  1. Press the on/off button to turn on the device. The device starts to operateLumea provides 5 different light intensities, you will always be able to change to a light intensity setting you find comfortable.

  2. Press the on/off button to turn on the device. The device starts to operate
    Note: To adjust the light intensity setting manually without using the SmartSkin button, use the toggle button until you have reached the required setting. The corresponding intensity light level lights up white.

  3. Press the SmartSkin button and put the device to your skin.

  4. After the device has scanned your skin, the light intensity indicators will blink white to indicate which intensities are most comfortable based on your skin tone.

  5. Press the confirmation button to confirm that you want to use the indicated setting. Lumea automatically uses the highest indicated intensity, which is shown by a blinking intensity indicator. Lumea gives you the freedom to select the light intensity that you find most comfortable. Skin sensitivity can differ per person. Therefore, the skin test is the most important guide for selecting your light intensity setting (see ‘B Test skin 24 hours before treatment’).

  6. Using Lumea should never be uncomfortably painful. If you experience discomfort, reduce the light intensity setting. You can do this by using the toggle buttons.
    Note: The device is automatically disabled when your skin tone is too dark (dark, according to the skin tone table), to prevent you from developing skin reactions. The ‘READY to flash’ light will blink orange to indicate if the skin tone is too dark.

  7. After moving to another body area or after recent tanning (see ‘Using your Lumea Prestige before and after tanning’), perform a skin test to determine a comfortable light intensity setting. To re-activate the setting indication feature, press the SmartSkin button.
    Note : Perform a skin test before you start to treat another body area or after a skin tone change. Determine the light intensity setting for each body area separately

Two treatment modes: Stamp & Flash and Slide & Flash

Your Philips Lumea has two treatment modes for more convenient use on different body areas:

  • The Stamp & Flash mode is ideal for treating small or curvy areas like knees and underarms. Simply press and release the flash button to release a single flash
  • The Slide & Flash mode is convenient to use on larger areas like legs. Keep the flash button pressed while you slide the device over your skin to release several flashes in a row.

Using your Lumea Prestige before and after tanning
Tanning with

Intentionally exposing your skin to natural or artificial sunlight with the aim of developing a tan influences the sensitivity and colour of your skin. Therefore the following is important:

  • After each treatment, wait at least 48 hours before tanning. Even after 48 hours, make sure that the treated skin does not show any redness from the treatment anymore.
  • If you expose your skin to the sun (without tanning intentionally) in the 48 hours after treatment, use a sunblock SPF 50 on the treated areas. After this period, you can use a sunblock SPF 50 for two weeks.
  • After tanning, wait at least 2 weeks before you use Lumea and perform a skin test. This is to determine the appropriate light intensity setting (see ‘B Test skin 24 hours before treatment’).
  • Do not use Lumea on sunburned body areas.

Note: Occasional and indirect sun exposure does not qualify as tanning.

Tanning with creams

If you have used an artificial tanning lotion, wait until the artificial tan is completely gone before you use the device.

Travelling with the device

When you travel with the device, check with the aeroplane carrier to confirm that the device can be carried and/or used on the aeroplane.

After use

Aftercare

After use, you can apply lotions, creams, deodorants, moisturizers or cosmetics to the treated areas.

Warning: If you experience skin irritation or skin redness after treatment, wait until it disappears before applying any product to your skin. If you experience skin irritation after applying a product to your skin, wash it off with water. If you still get skin reactions, stop using the device and consult your doctor.

Common skin reactions

Your skin may show slight redness and/or may prickle, tingle or feel warm. This reaction disappears quickly. Dry skin and itching may occur due to shaving or a combination of shaving and light treatment. You can cool the area with an ice pack or a wet face cloth. If dryness persists, you can apply a non-scented moisturizer on the treated area.

Rare side effects

  • Burns, excessive redness (e.g. around hair follicles) and swelling: these reactions occur rarely. They are the result of using a light intensity that is too high for your skin tone. If these reactions do not disappear within 3 days, we advise you to consult a doctor. Wait with the next treatment until the skin has healed completely and make sure you use a lower light intensity.
  • Skin discolouration: this occurs very rarely. Skin discolouration manifests itself as either a darker patch (hyperpigmentation) or a lighter patch (hypopigmentation) than the surrounding area. This is the result of using a light intensity that is too high for your skin tone. If the discolouration does not disappear within 2 weeks, we advise you to consult a doctor. Do not treat discoloured areas until the discolouration has disappeared and your skin has regained its normal skin tone.
  • Skin infection is very rare but is a possible risk following a (micro)wound, a skin burn, skin irritation, etc.
  • Epidermal heating (a sharply defined brownish area that often occurs with darker skin tones and is not accompanied by skin dryness): this reaction occurs very rarely. In case this reaction does not disappear within 1 week, we advise you to consult a doctor. Wait with the next treatment until the skin has healed completely and make sure you use a lower light intensity.
  • Blistering (looks like small bubbles on the surface of the skin): this occurs very rarely. In case this reaction does not disappear within 1 month or when the skin gets infected, we advise you to consult a doctor. Wait with the next treatment until the skin has healed completely and make sure you use a lower light intensity.
  • Scarring: often the secondary effect of a burn, which can take longer than a month to heal.
  • Folliculitis (swelling around hair follicles combined with pustule formation): this reaction occurs very rarely and is the result of bacteria penetrating the damaged skin. In case this reaction occurs, we advise you to consult a doctor as folliculitis may need antibiotic ointment.
  •  Pain: this can occur during or after treatment if you use the device on skin that is not hair-free, if you use the device at a light intensity that is too high for your skin tone, if you flash the same area more than once and if you use the device on open wounds, inflammations, infections, tattoos, burns, etc.

Troubleshooting

Philips-BRI940-Lumea-IPL-8000-Series-8000-Hair-Removal- Device-
FIG-44Philips-BRI940-Lumea-
IPL-8000-Series-8000-Hair-Removal- Device-FIG-45

Philips-BRI940-Lumea-IPL-8000-Series-8000-Hair-Removal- Device-
FIG-46

Warranty and support

If you need information or support, please visit www.philips.com/support or read the international warranty leaflet.

Recycling

  • This symbol means that this product shall not be disposed of with normal household waste (2012/19/EU).
  • Follow your country’s rules for the separate collection of electrical and electronic products. Correct disposal helps prevent negative consequences for the environment and human health.

Technical specifications

Philips-BRI940-Lumea-IPL-8000-Series-8000-Hair-Removal- Device-
FIG-47

Electromagnetic compatibility – Compliance information

This device complies with all applicable standards and regulations regarding exposure to electromagnetic fields.

Explanation of symbols

The warning signs and symbols are essential to ensure that you use this product safely and correctly and to protect yourself and others from injury. Below you find the meaning of the warning signs and symbols on the label and in the user manual.

This symbol identifies the manufacturer of the product: Philips Consumer Lifestyle B.V., Tussendiepen 4, 9206 AD Drachten, The Netherlands.

Philips-BRI940-Lumea-IPL-8000-Series-8000-Hair-Removal- Device-
FIG-37

Philips-BRI940-Lumea-IPL-8000-Series-8000-Hair-Removal- Device-
FIG-38

© 2022 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. (Royal Philips) or their respective owners.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Philips User Manuals

Related Manuals