Horstmann H27XL ChannelPlus Programmer User Manual

June 17, 2024
Horstmann

Horstmann H27XL ChannelPlus Programmer User Manual

Horstmann-H27XL-ChannelPlus-Programmer-fig-8

Horstmann’s ChannelPlus H27XL – Two Channel Programmer Offers up to three programmed operating periods per day, seven days a week, with independent Boost and advanced control on Fully Pumped Systems. Can be used as a direct replacement for the Horstmann 425 Diadem, Tiara and H527(Allowing for a new programmer position).

The following are some of the easy-to-operate features:

  • Flexible 7-Day Control
  • 1 or 2 Hour Boost on each channel
  • Independent timing on Hot Water and Heating
  • Advanced control gives instant On/Off override
  • Up to 3 On/Off periods per channel in each 24-hour operation.
  • Programme options: Auto / All day / On constantly / Off

LCD DISPLAY FEATURES

Horstmann-H27XL-ChannelPlus-Programmer-fig-1

  1. Current TIME OF DAY

  2. Day of Week Indicator

  3. Switch time SETTING indicator

  4. ADVANCE symbol

  5. BOOST symbol

  6. Current Hot water programme

  7. Current Central heating programme

  8. Next Central heating switch time

  9. Next Hot water switch time
    LED INDICATOR

  10. Central heating ON indicator

  11. Hot water ON indicator
    EASY TO USE PROGRAM ME AND FEATURE BUTTONS

  12. Central heating ADVANCE(ENTER) button

  13. Hot water ADVANCE (PLUS) button

  14. Central heating BOOST(COPY) button

  15. Hot water BOOST (MINUS)button Both the Central heating and Hot water SELECT buttons are located under the front  cover

RESETTING THE PROGRAMMER

Electronic equipment can in some circumstances be affected by electrical interference. If the programmer’s display becomes frozen or scrambled; or if you wish to revert to the default time settings please use the following procedure. Lower the front flap of the unit. On the Heating channel press the ADVANCE and SELECT buttons together then release the buttons and the programmer will return to the preset factory settings.

FRONT COVER
of this, the tap is unit to be closed & with the switch in any other position to remind the user The simple instructions below are designed to help with the programming of the unit. All the following instructions require the front tap to be lowered. Please replace the flap when normal operation is required.

SETTING THE DAY AND TIME OF DAY

Horstmann-H27XL-ChannelPlus-Programmer-fig-4

DEFAULT TIME SETTINGS

Horstmann-H27XL-ChannelPlus-Programmer-fig-4

The default factory settings are shown, however, if you wish to change these proceed as instructed below.

SETTING THE ON AND OFF TIMES

Horstmann-H27XL-ChannelPlus-Programmer-fig-4
Should you encounter any problems, please refer to the Question and Answer section located on page 4.

SPECIAL FEATURES

Horstmann-H27XL-ChannelPlus-Programmer-fig-7
The SET slide switch must be in the PROG.RUN position for the following instructions. The following actions work independently on either Hot Water or Central Heating.

BOOST FUNCTION – 1 or 2-hour temporary override

Horstmann-H27XL-ChannelPlus-Programmer-fig-8

ADVANCE FUNCTION – Brings forward next on or off operation

Horstmann-H27XL-ChannelPlus-Programmer-fig-8

HOLIDAY FUNCTION – Allows the system to be programmed for up to 32 days

Horstmann-H27XL-ChannelPlus-Programmer-fig-8

Whilst the HOLIDAY FUNCTION is in operation the system will remain OFF, the display will show the number of nights remaining. The HOLIDAY setting is an instant function and cannot be set in advance. The HOLIDAY FUNCTION can be cancelled at any time by pressing any of the SELECT buttons. Normal programme functions will resume at the first ON period after the pre-set number of nights has expired.

INFORMATION AND ADVICE

Programming ON/OFF times
If a Heating or Hot water period is not required it can be cancelled by setting the ON and OFF settings to the same time. For example ON 10:00 am OFF 10:00 am our programmer will prevent you from accidentally overlapping ON and OFF times.
Example: If the 2nd ON time is set at noon and then you try and set the 1st OFF at 12:30 pm the OFF settina will ‘bounce’ by 10 minutes until the 2nd ON time has been adjusted.

FULLY PUMPED OR GRAVITY SYSTEM
The installer will have set the programmer to suit the installed system. If this is a Fully pumped system this will allow independent control of the Central heating and Hot water, however on a Gravity system the Central heating and Hot water are linked so it is not possible to use the Central heating independently. This will allow only one common time setting for both Hot Water and Central Heating.

BATTERY
The programmer is fitted with a non-rechargeable, long-life battery, which will maintain the programmed time settings for a minimum of ten months with the supply disconnected. THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT. During power interruptions, the display will be blank, after 3 days the current time of day will be lost. If the programmer is not to be used for a long period, the switch on the rear of the unit should be returned to the BATTERY OFF position. These are both to prolong the battery life.

SERVICE AND REPAIR

This programmer is NOT user-serviceable. Please do not dismantle the unit. In the unlikely event of a fault developing please refer to the RESETTING THE PROGRAMMER section of this user guide located on page 2. If this fails to resolve the problem please contact a local heating engineer or a qualified electrician.

QUESTIONS AND ANSWERS

Horstmann-H27XL-ChannelPlus-Programmer-fig-8

Email: sales@horstmann.co.uk
Website. wwwhorstmann.co.uk

Download PDF:Horstmann H27XL ChannelPlus Programmer User Manual

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals