Coolair CFL150A1151 120V Ceiling Wall Mount Ventilators Instructions
- June 17, 2024
- Coolair
Table of Contents
MODELS • CFL90A1151 • CFL150A1151
CEILING / WALL-MOUNT
VENTILATORS • 120V
CFL150A1151 120V Ceiling Wall Mount Ventilators
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
- Use this unit only in the manner intended by the manufacturer. Ifyou have questions, contact the manufacturer at the address or telephone number listed in the warranty.
- Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
- Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
- Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
- When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
- Ducted fans must always be vented to the outdoors.
- To reduce the risk of fire, use only metal ductwork.
- If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Interrupter) – protected branch circuit.
- Never place a switch where it can be reached from a tub or shower.
- This unit must be grounded.
CAUTION
- For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
- To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
- Please read specification label on product for further informa- tion and requirements.
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 3.
TYPICAL INSTALLATION
MOUNTING (New Frame Construction)
Factory-shipped unit installed in new construction.
MOUNTING (Existing Frame Construction)
Factory-shipped unit installed in existing construction.
WIRING
Ventilator can be wired from outside of housing.
Use UL approved connectors to wire per local codes.
DUCTING (Horizontal blower discharge)
Two ways to connect ductwork to a factory-shipped unit.
IMPORTANT:
Remove shipping tape from damper
Remove the shipping tape from the damper flap and make sure that damper flap
opens and closes freely inside the ductwork. Use duct tape to make ductwork
connections secure and air-tight.
MOUNTING OPTIONS
¼-20 hex nuts secure mounting brackets to housing. Loosen and re-tighten or remove and replace nuts as necessary for desired mounting bracket position.
WIRING OPTIONS
WIRING PLATE POSITION
DUCTING OPTIONS
BLOWER DISCHARGE POSITIONS
DUCTING (Vertical blower discharge)
Typical ductwork connection to a ventilator converted to vertical discharge.
USE AND CARE
Ventilator is designed for continuous operation. If desired, it may be
controlled using an on/off switch or a solid-state, variable speed control.
Follow wiring instructions packed with control, and adhere to all local and
state codes, and the National Electrical Code.
WARNING: To reduce the risk of electric shock, disconnect from power
supply before servicing.
To clean grille: Use appropriate vacuum attachment or remove grille and clean
with a soft cloth and mild soap or detergent. Dry grille thoroughly before
reinstalling.
To clean blower assembly: Remove grille, unplug blower from housing, remove
blower mounting nuts, and carefully remove blower from housing. Use
appropriate vacuum attachment or a soft cloth and mild soap or detergent to
clean blower discharge area and wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make
sure blower assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.
SERVICE PARTS
KEY NO. | PART NO. | DESCRIPTION |
---|---|---|
1 | 97014853 | Damper Flap |
2 | 99150415 | Screw, #8B x ¼* (10 req.) |
3 | 98009520 | Duct Connector |
4 | 97014784 | Housing Assembly |
5 | 97014728 | Mounting Bracket (2 req.) |
6 | 99150591 | Mounting Screw (4 req.) |
7 | 97006142 | Wiring Harness |
8 | 99150471 | Ground Screw, #10-32 x ½* (2 req.) |
9 | 98005512 | Wiring Adapter Plate |
10 | 99420466 | Insulation Mounting Clip (16 req.) |
11 | 99420470 | Grille Nut (4 req.) |
12 | 98009518 | Movable Housing Panel |
13 | 93150487 | Screw, #10-24 x .375* (8 req.) |
14 | 98005513 | Outlet Box Cover |
15 | 99400035 | Strain Relief Bushing |
16 | 99500394 | Insulation, Front |
17 | 99500393 | Insulation, Base |
18 | 99500395 | Insulation, Back |
19 | 97014788 | Motor Bracket |
20 | 99260477 | Whiz Nut, ¼-20* (11 req.) |
21 | 99200202 | Screw, ¼-20 x ½* (5 req.) |
22 | 97014785 | Blower Scroll |
23 | 99080490 | |
99080491 | Motor (CFL90A1151) |
Motor (CFL150A1151)
24| 93260447| Nut, Hex Flange 5/16-18 (5 req.)
25| 98009516| Support Bracket
26| 99680019| Wheel Clamp
27| 99020274| Blower Wheel (Includes Key No. 26)
28| 98009514| Inlet Ring
29| 99150417| Screw, #8-18 x ¼ (5 req.)
30| 98009513| Scroll Support Channel
+| 97014848| Blower Assembly Complete (CFL90A1151)
(Includes Key Nos. 19 thru 30)
+| 97014849| Blower Assembly Complete (CFL150A1151)
(Includes Key Nos. 19 thru 30)
31| 98009522| Grille
32| 99150472| Grille Screw (4 req.)
Order replacement parts by PART NO. – not by KEY NO.
- Standard hardware – may be purchased locally.
+ Not shown assembled.
WARRANTY
Limited Warranty
In the sale of its products, American Coolair Corporation agrees to correct,
by repairs or replacement, any defects in workmanship or material that may
develop under proper and normal use during the period of one year from date of
shipment from factory. Any product or part proving, upon American Coolair’s
examination, to be defective during limited warranty period will be repaired
or replace, at American Coolair’s option, f.o.b. factory, without charge.
Deterioration or wear caused by chemicals, abrasive action or excessive heat
shall not constitute defects.
Motors are guaranteed only to the extent of manufacturer’s warranty.
American Coolair’s limited warranty does no apply to any of its products or
parts that have been subject to accidental damage, misuse by the user,
unauthorized alterations, improper installation or electrical wiring, or lack
of proper lubrication of other service requirements established by American
Coolair.
Repairs or replacements provided under the above terms shall constitute
fulfillment of all American Coolair’s obligations with respect to limited
warranty.
THE LIMITED WARRANTY STATED HEREIN IS IN LIEU OF ALL OTHER WARRANTIES.
EXPRESS, STATUTORY OR IMPLIED, INCLUDING WITHOUT LIMITATION THAT OF
MERCHANTABILITY AND FITNESS.
NO LIABILITY FOR REINSTALLATION COST OF FOR ANY SPECIAL, INDIRECT OR
CONSEQUENTIAL DAMAGES OF ANY NATURE IS ASSUMED OR SHALL BE IMPOSED UPON
AMERICAN COOLAIR.
AMERICAN COOLAIR CORP. / ILG INDUSTRY, 3604 MAYFLOWER ST.
JACKSONVILLE, FLORIDA 32205, TEL:
904-389-3646
99042881A
Documents / Resources
|
Coolair CFL150A1151 120V Ceiling Wall Mount
Ventilators
[pdf] Instructions
CFL150A1151 120V Ceiling Wall Mount Ventilators, CFL150A1151, 120V Ceiling
Wall Mount Ventilators, Ceiling Wall Mount Ventilators, Wall Mount
Ventilators, Mount Ventilators, Ventilators
---|---