Coolair CFL150A1151 120V Ceiling Wall Mount Ventilators Instructions

June 17, 2024
Coolair

MODELS • CFL90A1151 • CFL150A1151

CEILING / WALL-MOUNT
VENTILATORS • 120V

CFL150A1151 120V Ceiling Wall Mount Ventilators

READ AND SAVE THESE INSTRUCTIONS

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  1. Use this unit only in the manner intended by the manufacturer. Ifyou have questions, contact the manufacturer at the address or telephone number listed in the warranty.
  2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent  warning device, such as a tag, to the service panel.
  3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
  4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those  published by  the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
  6. Ducted fans must always be vented to the outdoors.
  7. To reduce the risk of fire, use only metal ductwork.
  8. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Interrupter) – protected branch circuit.
  9. Never place a switch where it can be reached from a tub or shower.
  10. This unit must be grounded.

CAUTION

  1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
  2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
  3. Please read specification label on product for further informa- tion and requirements.

Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 3.

TYPICAL INSTALLATION

MOUNTING (New Frame Construction)

Factory-shipped unit installed in new construction.

MOUNTING (Existing Frame Construction)

Factory-shipped unit installed in existing construction.

WIRING

Ventilator can be wired from outside of housing.
Use UL approved connectors to wire per local codes.

DUCTING (Horizontal blower discharge)

Two ways to connect ductwork to a factory-shipped unit.

IMPORTANT:
Remove shipping tape from damper
Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork. Use duct tape to make ductwork connections secure and air-tight.

MOUNTING OPTIONS

¼-20 hex nuts secure mounting brackets to housing. Loosen and re-tighten or remove and replace nuts as necessary for desired mounting bracket position.

WIRING OPTIONS

WIRING PLATE POSITION

DUCTING OPTIONS

BLOWER DISCHARGE POSITIONS

DUCTING (Vertical blower discharge)

Typical ductwork connection to a ventilator converted to vertical discharge.

USE AND CARE

Ventilator is designed for continuous operation. If desired, it may be controlled using an on/off switch or a solid-state, variable speed control. Follow wiring instructions packed with control, and adhere to all local and state codes, and the National Electrical  Code.
WARNING: To reduce the risk of electric shock, disconnect from power supply before servicing.
To clean grille: Use appropriate vacuum attachment or remove grille and clean with a soft cloth and mild soap or detergent. Dry grille thoroughly before reinstalling.
To clean blower assembly: Remove grille, unplug blower from housing, remove blower mounting nuts, and carefully remove blower from housing. Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make sure blower assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.

SERVICE PARTS

KEY NO. PART NO. DESCRIPTION
1 97014853 Damper Flap
2 99150415 Screw, #8B x ¼* (10 req.)
3 98009520 Duct Connector
4 97014784 Housing Assembly
5 97014728 Mounting Bracket (2 req.)
6 99150591 Mounting Screw (4 req.)
7 97006142 Wiring Harness
8 99150471 Ground Screw, #10-32 x ½* (2 req.)
9 98005512 Wiring Adapter Plate
10 99420466 Insulation Mounting Clip (16 req.)
11 99420470 Grille Nut (4 req.)
12 98009518 Movable Housing Panel
13 93150487 Screw, #10-24 x .375* (8 req.)
14 98005513 Outlet Box Cover
15 99400035 Strain Relief Bushing
16 99500394 Insulation, Front
17 99500393 Insulation, Base
18 99500395 Insulation, Back
19 97014788 Motor Bracket
20 99260477 Whiz Nut, ¼-20* (11 req.)
21 99200202 Screw, ¼-20 x ½* (5 req.)
22 97014785 Blower Scroll
23 99080490
99080491 Motor (CFL90A1151)

Motor (CFL150A1151)
24| 93260447| Nut, Hex Flange 5/16-18 (5 req.)
25| 98009516| Support Bracket
26| 99680019| Wheel Clamp
27| 99020274| Blower Wheel (Includes Key No. 26)
28| 98009514| Inlet Ring
29| 99150417| Screw, #8-18 x ¼
(5 req.)
30| 98009513| Scroll Support Channel
+| 97014848| Blower Assembly Complete (CFL90A1151)
(Includes Key Nos. 19 thru 30)
+| 97014849| Blower Assembly Complete (CFL150A1151)
(Includes Key Nos. 19 thru 30)
31| 98009522| Grille
32| 99150472| Grille Screw (4 req.)

Order replacement parts by PART NO. – not by KEY NO.

  • Standard hardware – may be purchased locally.
    + Not shown assembled.

WARRANTY

Limited Warranty
In the sale of its products, American Coolair Corporation agrees to correct, by repairs or replacement, any defects in workmanship or material that may develop under proper and normal use during the period of one year from date of shipment from factory. Any  product or part proving, upon American Coolair’s examination, to be defective during limited warranty period will be repaired or replace, at American Coolair’s option, f.o.b. factory, without charge.
Deterioration or wear caused by chemicals, abrasive action or excessive heat shall not constitute defects.
Motors are guaranteed only to the extent of manufacturer’s warranty.
American Coolair’s limited warranty does no apply to any of its products or parts that have been subject to accidental damage, misuse by the user, unauthorized alterations, improper installation or electrical wiring, or lack of proper lubrication of other service  requirements established by American Coolair.
Repairs or replacements provided under the above terms shall constitute fulfillment of all American Coolair’s obligations with respect to limited warranty.
THE LIMITED WARRANTY STATED HEREIN IS IN LIEU OF ALL OTHER WARRANTIES. EXPRESS, STATUTORY OR IMPLIED, INCLUDING WITHOUT LIMITATION THAT OF MERCHANTABILITY AND FITNESS.
NO LIABILITY FOR REINSTALLATION COST OF FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE IS ASSUMED OR SHALL BE IMPOSED UPON AMERICAN COOLAIR.
AMERICAN COOLAIR CORP. / ILG INDUSTRY, 3604 MAYFLOWER ST.
JACKSONVILLE, FLORIDA 32205, TEL: 904-389-3646

99042881A

Documents / Resources

| Coolair CFL150A1151 120V Ceiling Wall Mount Ventilators [pdf] Instructions
CFL150A1151 120V Ceiling Wall Mount Ventilators, CFL150A1151, 120V Ceiling Wall Mount Ventilators, Ceiling Wall Mount Ventilators, Wall Mount Ventilators, Mount Ventilators, Ventilators
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals