AVENTICS EP-Pressure Controller 561 014 903 0 Instructions

June 4, 2024
AVENTICS

EP-Pressure Controller 561 014 903
Instructions

EP-Pressure Controller 561 014 903 0

This short instruction describes the electrical connections of the VDS pressure control valve ED05. For further information please refer to the user manual of the used bus coupler and device description. These manuals are available at AVENTICS and must be read thoroughly before installing and initial start-up of the module.
This device fulfills the categories 3G and 3D according to ATEX directive 2014/34/EU. If the device is used in potentially explosive atmospheres attention has to be paid to the corresponding themes in the device description.

EP-Pressure Controller 561 014 903 - Fig

Electrical Connection

X1S: Power supply
XPV1: VDS-Output
XPV2: VDS-Input

Pin 1 n.c.
Pin 2 24V valve (fuse M 1,6A external)
Pin 3 0V valve
Pin 4 FE

X1S: Power supply
The 0V of the pressure control valve has to be connected directly with the 0V of the Bus Coupler.
The pressure control valve is defined as equipment with low energy. It has to be supplied with electrical power from a power pack with over-voltage protection according to standard DIN EN 60079-15; 2011-02.

Control Data

The Control data are described in the device description.

Declaration of conformity valid until 2016, Apr. 19th) in accordance with ATEX Directive 94/9/EC The EMC directive 2004;108/EC also was applied.
EU declaration of conformity valid from 2016, Apr. 20th) in accordance with ATEX Directive 2014/34/EU and in accordance with the EMC directive 2014/30/EU.

  1. Apparatus model/Product: EP-PRESSURE REGULATOR, ED05-VDS

  2. Name and address of the manufacturer: AVENTICS GmbH Ulmer Str. 4 30880 Laatzen, GERMANY

  3. This declaration is issued under the sole responsibility of the manufacturer.

  4. The object of the declaration material number(s): 5610149030

  5. The object of the declaration described above is in conformity with the relevant Union harmonization legislation. as referred to in the headlines of this document.

  6. References to the relevant harmonized and other standards used:
    • EN 60079-0 (2012-08-00) + All (2013-11-00) Gerate — Allgemeine Anforderungen
    Explosive atmospheres — Part 0: Equipment — General requirements
    • EN 60079-15 (2010-05-00) Bereiche — Teil 15: Electrical apparatus for explosive gas atmospheres — Part 15. Construction, test, and marking of type of protection „n” electrical apparatus
    • EN 60079-31 (201407-00) Explosionsfahige Atmosphere — Teil 31: Part 31: Equipment dust ignition protection by enclosure ,t”
    • EN 61000-6-2 (2005-08-00) + AC (2005-09-00)(EMV) – Tel 6-2: Fachgrundnomien – (EMC) – Part 6-2. Generic standards – Immunity for industrial environments
    • EN 61000-6-4 (2007-01-00) + Al (2011-02-00) Elektromagnetische Vertraglichkeit (EMV) – Teil 6-4: Fachgrundnorrnen – Generic standards – Emission standards for industrial environments
    • EN ISO 4414:2010 (2010-11-00) General rules and safety requirements for systems and their components
    We reserve the right to make changes in the declaration Presently applicable edition can be obtained upon request.

  7. A notified body was not involved.

  8. Additional information: The instructions in the Operation Manual are to be kept.

EP-Pressure Controller 561 014 903 - Fig 1

AVENTICS GmbH
Ulmer Str. 4
D-30880 Laatzen
GERMANY
Tel. +49(0)511/2136-0
Fax. +49(0)511/2136-269
R499050003-DAT-001-AG