AVENTICS IS12-PD-ISO 5599-1 Dual valve, IS12-PD series, size 2 Instruction Manual
- June 3, 2024
- AVENTICS
Table of Contents
- About This Documentation
- Notes on Safety
- General Instructions on Equipment and Product Damage
- Delivery Contents
- Device Description
- Function Description
- Transport and Storage
- Assembly
- Commissioning
- Operation
- Care and Maintenance
- Removing the Dual Valve from the System
- Disposal
- Troubleshooting
- Spare Parts and Accessories
- Technical Data
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AVENTICS IS12-PD-ISO 5599-1 Dual valve, IS12-PD series, size 2 Instruction
Manual
Figures: View varies according to the series.
Device overview, material number R422003622–625
Device overview IS12-PD
Name plate
- Company name
- Company address
- CE mark
- Material number
- Type designation
- Production date
- Maximum pressure
- Country of manufacture
- Responsible plant
Wiring diagram for variants R422003622–625, internal pilot (left) and external pilot (right)
Wiring diagram for variants R422003189–192, internal pilot (left) and external pilot (right)
Application examples: left without non-return valve, right with non-return valve
Pin assignments for the M8x1 sensor plug
Pin assignment for coil, form A, series CN1
Pin assignment for coil M12 in accordance with ISO 20401
Distances of mounting holes
About This Documentation
Documentation validity
This documentation applies to the following dual valve variants (two
electrically operated pneumatic 5/2 directional valves, IS12-PD series, size
1, with slider position detection):
Material number (single valve) | Coil | MO | Pilot | Non-return valve |
---|---|---|---|---|
R422003622 (R422102677) | 24 V DC M12 | Without detent | External | No |
R422003623 (R422102677) | 24 V DC M12 | Without detent | Internal | No |
R422003624 (R422002577) | 24 V DC |
form A
| Without detent| External| No
R422003625 (R422002577)| 24 V DC
form A
| Without detent| Internal| No
R422003189 (R422102677)| 24 V DC M12| Without detent| External| Yes
R422003190 (R422102676)| 24 V DC M12| Without detent| Internal| Yes
R422003191 (R422002577)| 24 V DC
form A
| Without detent| External| Yes
R422003192 (R422002521)| 24 V DC
form A
| Without detent| Internal| Yes
This documentation is intended for installers, operators, service technicians,
and systems owners.
This documentation contains important information on the safe and appropriate
transport, assembly, commissioning, and maintenance of the product.
Read this documentation completely, especially chapter “2 Notes on Safety” before working with the product.
This product is provided with a CE mark. The EC declaration of conformity is included in the operating instructions
Required documentation
The dual valve is a system component.
Also observe the instructions for the other system components and
manufacturer’s system documentation.
Presentation of information
Safety instructions
In this documentation, there are safety instructions before the steps whenever
there is a risk of personal injury or damage to equipment. The measures
described to avoid these hazards must be followed. Safety instructions are set
out as follows:
SIGNAL WORD
Hazard type and source
Consequences of non-observance
Measures to avoid these hazards
- Safety sign (warning triangle): draws attention to the risk
- Signal word: identifies the degree of hazard
- Hazard type and source: identifies the hazard type and source
- Consequences: describes what occurs when the safety instructions are not complied with
- Precautions: states how the hazard can be avoided
Meaning of the signal words
Hazard classes according to ANSI Z 535.6-2006
DANGER
Indicates a hazardous situation which, if not avoided, will certainly result
in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death
or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor
or moderate injury.
NOTICE
Indicates that damage may be inflicted on the product or the environment.
Symbols
The following symbol indicates information that is not relevant for safety but
that helps in comprehending the documentation.
Symbol/Meaning
If this information is disregarded, the product cannot be used or operated optimally.
Abbreviations
This documentation uses the following abbreviations:
Abbreviation/Meaning
CCF| Common Cause Failure|
DC| Diagnostic coverage|
MO| Manual override|
PL| Performance level|
PLr| Required performance level|
SF| Safety function|
Notes on Safety
About this chapter
The product has been manufactured according to the accepted rules of current
technology. Even so, there is risk of injury and damage to equipment if the
following chapter and safety instructions of this documentation are not
followed.
- Read these instructions completely before working with the product.
- Keep this documentation in a location where it is accessible to all users at all times.
- Always include the documentation when you pass the product on to third parties.
Intended use
The dual valve is a safety component in accordance with Machinery Directive
2006/42/EC and is therefore provided with the CE mark. The intended use is the
exhaust in compressed air systems or equivalent applications and the
prevention of unexpected start-ups.
- See section 16 “Technical Data” for the standards and test values complied with and adhered to by the product.
- The pressure regulator may only be used within the limits listed in the technical data.
The product is intended for professional use only.
Intended use includes having read and understood this documentation,
especially the chapter 2 “Notes on Safety”.
Safety function according to ISO 13849
The dual valve is a redundant system according to the requirements of ISO
13849-1 and -2, in which the pneumatic safety functions “safe exhaust” and
“prevention of unexpected start-ups” are ensured, including in case of a valve
fault (e.g. due to wear).
With correct integration in the control system in accordance with ISO 13849-1
and -2, these products can be used in up to category 3 and 4 and a performance
level up to e can be achieved.
The valves used have a slider position detection and improve the diagnostic
coverage level of the control.
The product has been engineered and manufactured according to the fundamental
and proven safety principles of ISO 13849-2.
Common Cause Failure – CCF
The following measures must be ensured by the user to prevent failures due to
common causes:
- Observe the temperature range (see chapter 16 “Technical Data”)
- Observe the compressed air quality (see chapter 10 “Operation”)
- Observe the permissible operating pressure (see chapter 16 “Technical Data”)
- Observe the permissible voltage and current range for coils and sensor (see chapter 16 “Technical Data”)
Proper use of this product also includes the user knowing and implementing all further requirements from ISO 13849-1 and -2 (e.g. measures for the software, diagnosis, against further CCF, against systematic failures etc.) and then evaluating whether the necessary performance level has been achieved.
Improper use
WARNING:
Misuse may result in injury or damage.
The following applications are therefore prohibited:
- Use in non-industrial applications/residential areas,
- Outdoor use,
- Use outside of the product limits defined in the technical data,
- Unauthorized modifications,
- Use in reversible operation (reversing of supply and exhaust air),
- Vacuum operation,
- Use in ATEX certified areas,
- Use near to ferromagnetic parts (a safety clearance of 30 mm to the sensor must be maintained and magnetic fields must generally be avoided)
Any use other than that described under Intended use is improper and is not
permitted.
AVENTICS GmbH is not liable for any damages resulting from improper use. The
user alone bears the risks of improper use of the product.
Personnel qualifications
The work described in this documentation requires basic mechanical, electrical
and pneumatic knowledge, as well as knowledge of the appropriate technical
terms. In order to ensure safe use, these activities may therefore only be
carried out by qualified technical personnel or an instructed person under the
direction and supervision of qualified personnel.
Qualified personnel are those who can recognize possible hazards and institute
the appropriate safety measures, due to their professional training,
knowledge, and experience, as well as their understanding of the relevant
regulations pertaining to the work to be done. Qualified personnel must
observe the rules relevant to the subject area.
General safety instructions
-
Observe the regulations for accident prevention and environmental protection.
-
Observe the safety instructions and regulations of the country in which the product is used.
-
Only use dual valves that are in perfect working order.
-
Follow all the instructions on the product.
-
Persons who assemble, operate, disassemble, or maintain the dual valve must not consume any alcohol, drugs, or pharmaceuticals that may affect their ability to respond.
-
Only use accessories and spare parts approved by the manufacturer.
-
Comply with the technical data and ambient conditions listed in the product documentation.
-
If unsuitable products are installed or used in safety-relevant applications, this may result in uncontrolled system operating states that may lead to injuries or equipment damage.
Therefore, only use a product in safety-relevant applications if such use is specifically stated and permitted in the product documentation. -
You may only commission the product if you have determined that the end product (such as a machine or system) in which the AVENTICS products are installed meets the countryspecific provisions, safety regulations, and standards for the specific application.
Safety instructions related to the product and technology
WARNING
Danger of injury due to stored energy (compressed air) and voltage!
When the system is at a standstill, there is still a danger due to stored
energy (compressed air) and voltage.
- Generally avoid storing compressed air.
- Make sure that the relevant system part is not under voltage or pressure before you assemble or disassemble the product.
- Exhaust the system before working on it.
- Always protect the system against being switched on.
- Remove all other sources of danger in the immediate work area that may result from stored energy in the system.
Danger of injury by dismantling the dual valve or valve!
Pre-tensioned springs may suddenly be released when dismantling.
- Never disassemble the dual valve or valves.
- Never unscrew the non-return valve found in connection 4 ext ( –11).
- Do not remove silencers on connection 5 ( –7, –7) to avoid changing the specified noise level.
- Do not remove the mounting screws for the valve cover ( –2, 3).
- Do not remove the mounting screws for the pilot valve ( –13).
- Do not remove the mounting screws for the sensor housing ( –5).
- Do not replace or disassemble the sensor, or change its position.
Injuries if system-specific limits are not complied with!
The operating conditions for the dual valve may deviate from the system
operating conditions.
- Always observe the information in the documentation for the superior system.
- Before assembly, contact the system manufacturer or AVENTICS GmbH to clarify any contradictions or questions.
Danger of burns caused by hot surfaces!
Touching the surfaces of the dual valve and adjacent components during
operation could cause burns.
- Let the relevant system component cool down before working on the dual valve.
- Do not touch the relevant system component during operation.
Risk of injury due to loss of the safety function!
Depending on the application, you must take appropriate measures to ensure the
safety function.
- When implementing safety measures against switch-off surges, check whether these extend the valve’s switch-off time.
- Check if the valve’s electrical connection cables have to be routed separately.
- In case of high levels of machine vibrations, use appropriate vibration-reducing elements when mounting the dual valve.
- Avoid overvoltages. These result in solenoid burnout.
The dual valve comes with a special silencer that complies with the requirements of ISO 13849 and which features a design that largely prevents clogging.
- Only use the dual valve with a properly mounted silencer.
- Make sure that the silencer’s flow capacity is not restricted. This would impair valve performance.
- Only replace the silencer with a corresponding model (AVENTICS material number R412010246).
Personal protective equipment
Wear appropriate protective clothing during assembly and maintenance. Observe the applicable occupational safety regulations for the system.
Obligations of the system owner
As the owner of a system that will be equipped with a dual valve you are responsible for
- ensuring intended use,
- ensuring that operating employees receive regular instruction,
- ensuring that the operating conditions are in line with the requirements for the safe use of the product,
- ensuring that no unauthorized repairs are attempted if there is a malfunction
Other requirements of the operator:
- Observe the information on assembly and operating conditions listed in the operating instructions or the data sheet.
- Comply with the further requirements of ISO 13849 (e.g. CCF, DC, PLr, software) if you intend to use the product in higher categories (2 to 4).
- Make sure that the maximum number of switching cycles (B10d) within the service life TM (typical assumption as per ISO 13849-1 = 20 years) is not exceeded. If the expected number of switching cycles for a component exceeds the B10d value during its period of use, suitable exchange intervals have to be specified.
- Switch the valve at least once a month to ensure its proper function.
- Make sure that the fundamental and proven safety principles in accordance with ISO 13849 for implementation and operation of the component are complied with.
- Make sure that the permissible positive and negative test pulses for feedback-free operation of the pneumatic devices are observed. (see chapter 16 “Technical Data”).
General Instructions on Equipment and Product Damage
NOTICE
Dual valve damage due to falling!
If the module falls, the product may be damaged even if no damage is visible.
- Always transport the module carefully.
- If the module has fallen, it may no longer be installed.
- Check the packaging when you receive the product. If the packaging is damaged, the module must not be installed.
Delivery Contents
The scope of delivery includes:
-
1 dual valve (valve, size 1, with mounted and adjusted ST4 sensor
with M8x1 connection) -
1 set of operating instructions
Device Description
Product identification
Check the material number of the dual valve ( –8 , –8) on the name plate,
which can be found on the base plate, to determine whether the product matches
your order (for details on the name plate see ).
The production date consists of five numbers, with the first 3 digits showing
the production year and production month and the last two digits stating the
day of production. The following table shows our coding for the first 3
digits:
Year| Jan| Feb| Mar| Apr| May| Jun| Jul| Aug|
Sep| Oct| Nov| Dec
---|---|---|---|---|---|---|---|---|---|---|---|---
2014| 417| 418| 419| 420| 453| 454| 455| 456| 457| 458| 459| 460
2015| 517| 518| 519| 520| 553| 554| 555| 556| 557| 558| 559| 560
2016| 617| 618| 619| 620| 653| 654| 655| 656| 657| 658| 659| 660
…| | | | | | | | | | | |
2019| 917| 918| 919| 920| 953| 954| 955| 956| 957| 958| 959| 960
2020| 037| 038| 039| 040| 073| 074| 075| 076| 077| 078| 079| 080
2021| 137| 138| 139| 140| 173| 174| 175| 176| 177| 178| 179| 180
…| | | | | | | | | | | |
2029| 937| 938| 939| 940| 973| 974| 975| 976| 977| 978| 979| 980
2030| 0A1| 0A2| 0A3| 0A4| 0A5| 0A6| 0A7| 0A8| 0A9| 0AA| 0AB| 0AC
2031| 1A1| 1A2| 1A3| 1A4| 1A5| 1A6| 1A7| 1A8| 1A9| 1AA| 1AB| 1AC
…| | | | | | | | | | | |
2040| 0B1| 0B2| 0B3| 0B4| 0B5| 0B6| 0B7| 0B8| 0B9| 0BA| 0BB| 0BC
2041| 1B1| 1B2| 1B3| 1B4| 1B5| 1B6| 1B7| 1B8| 1B9| 1BA| 1BB| 1BC
2042| 2B1| 2B2| 2B3| 2B4| 2B5| 2B6| 2B7| 2B8| 2B9| 2BA| 2BB| 2BC
Dual valve 1,2
- Valve 1: IS12-PD
- Valve 2: IS12-PD
- Mounting screws 4 x Ø 6.4 mm for M6 screws
- Base plate
- Connection 1, G1/4
- External pilot connection G1/8
- Exhaust ports with silencer
- Label
- Sensor LED
- Working connection 2 or 4, G1/4
- Connection 4 ext, G1/4 (for non-return valve)
Valve IS12-PD 3
- Valve
- Valve cover, valve side 12
- Valve cover, valve side 14
- Sensor housing, bolted to valve cover (3)
- Mounting screws for the sensor housing
- Sensor slot
- Sensor cable
- Sensor plug
- Sensor LED
- Coil lock nut
- Coil
- Contact for connecting an electrical connector
- Mounting screws for the pilot valve
- Pilot valve
- Mounting screws for valve
- Base plate gasket
Function Description
Dual valve
The dual valve includes two IS12-PD valves with slider position detection and
can fulfill the two following safety functions:
- SF1: Safe exhaust
- SF2: Prevention of unexpected start-up
The dual valve is available in two different configurations: without and with
integrated non-return valve (see Fig. and ).
A system that is connected to working connection 2 of the dual valve (or 4 for
the variant with non-return valve) of the dual valve is protected against
unexpected start-up and can be safely exhausted. It is also possible to choose
a variant with integrated nonreturn valve, to secure a start-up valve
connected to connection 4 of the dual valve for example, as shown in Fig. on
the right.
In addition to the dual channel design, the valves are equipped with a slider
position detection (see “Valve with position detection” for details) to
improve the diagnostic coverage level.
Both sensors emit a signal (supply voltage) when working perfectly. One of the
valve does not emit a signal in case of malfunction. No further cycle must be
performed in this case, otherwise the dual duct capacity can no longer be
ensured. It is not sufficient to check whether the sensor signal shows ON
after switching the valves off. With each cycle, it must be checked whether
the sensor signal changes from OFF to ON.
Both safety functions are described in more detail in the following. The procedure to test the safety functions is explained in chapter 9 “Commissioning”.
SF1: Safe exhaust
Both valves are electrically switched off to exhaust a system connected to the
dual valve.
Variant without non-return valve
In fault-free operation, the exhaust from the connected system can be
exhausted via dual ducts, using both connection 1 of valve 2 (sensor and coil
labeled with BG2 or MB2) or via connection 4 of valve 1 (sensor and coil
labeled with BG1 or MB1).
If valve 2 does not allow any more exhausting, the air can escape via valve 1
and vice versa.
Furthermore, if valve 2 remains in the closed position (valve connection 2
remains connected with valve connection 3), the exhaust air can escape through
connection 2 of valve 1 via connection 3 of the dual valve.
Variant with non-return valve
In fault-free operation, the exhaust from the connected system can be
exhausted via dual ducts, both via connection 5 of valve 2 or via connection 5
of valve 1.
If valve 2 does not allow any more exhausting, the air can escape via valve 1
and vice versa.
Furthermore, if valve 2 remains in the switched position (valve connection 4
remains connected with valve connection 1), the exhaust air can escape through
connection 4 of valve 1 via connection 5 of the dual valve.
The exhaust duct on the system to be secured must be connected with connection
4 and 4 ext of the dual valve. Even if connection 4 ext is not required, this
must be connected (add connection between connection 4 and 4 ext of the dual
valve) to ensure dual duct exhaust.
The non-return valve function is not monitored. The requirements of category 3
or 4 are not fulfilled. The variant with non-return valve is therefore
classified in category 1 and a maximum PL = c can be achieved.
SF2: Prevention of unexpected start-up
Both valves are switched without current with this function (when working
perfectly). Even if one of the two valves is unintentionally switched on, the
system connected to the dual valve is not pressurized.
Variant without non-return valve
Series connection of both valves allows double protection against unexpected
start-up. If valve 1 pressurizes valve connection 2, pressurization of the
overall system is still prevented by the blocked valve connection 2 of valve
2. If valve 2 switches unintentionally, the air supply is still prevented by
valve 1, i.e. connection 2 of the dual valve is not pressurized.
Variant with non-return valve
If valve 1 pressurizes valve connection 2, connections 4 and 4 ext of the dual
valve are still disconnected from the compressed air supply because valve 2
and the non-return valve block the compressed air supply.
In case of a malfunction of valve 2 or the non-return valve, the air supply is
still blocked by valve 1 i.e. connections 4 and 4 ext of the dual valve are
not pressurized.
The non-return valve is not position monitored. If you require a PL e, you can
undertake fault exclusion for the IS12-PD valves for independent change of the
output switching position (without input signal).
Valve with position detection
IS12-PD series valves are electrically operated pneumatic 5/2 directional
valves with an integrated slider position detection. Slider position detection
is realized by means of the following system: A magnet is integrated in the
piston (slider) of the valve and an ST4 series proximity sensor with an M8x1
connection is installed in a sensor housing on valve side 14.
The sensor LED indicates the position of the slider. This allows the user to
detect whether the valve is in the home position (sensor LED is lit) or in the
switching state (sensor LED is not lit). In addition, the position of the
sensor is transferred to the controller via the M8 connection, PIN 4 (OUT).
The sensor is switched on when the slider is located on valve side 14, meaning
in home position. In this case, the sensor LED is lit.
The sensor is switched off when the slider is located on valve side 12, i.e.
in the switching position. In this case, the sensor LED is not lit.
Home position, sensor LED lit
When the valve is not actuated electrically, it is in home position. The
slider is positioned so that connections 1 and 2 and connections 4 and 5 are
connected respectively. With typical use, connection 2 is under pressure while
connection 4 is pressure-free. The sensor LED is switched on and indicates
that the valve is in the home position. The output voltage is applied to pin 4
(OUT). To ensure the system is not under pressure in home position, the
working connection to the system must be connected at connection 4.
Switching position, sensor LED not lit
When the valve is actuated electrically, it is in switching position. The
slider is positioned so that connections 2 and 3 and connections 1 and 4 are
connected respectively. With typical use, connection 2 is pressure-free while
connection 4 is under pressure. The sensor LED is switched off and indicates
that the valve is in the switching position. 0 volts are applied to pin 4
(OUT). To ensure the system is under pressure in the switching position, the
working connection to the system must be connected at connection 4.
Change of sensor signal when pressurizing working connection 2 or 4
When the valve is switched on, the slider moves from valve side 14 to valve
side 12 (see number 2 and 3 in Fig. ). During slider movement, the signal of
the sensor switches from “ON” to “OFF”.
Change of sensor signal when exhausting working connection 2 or 4
When the valve is switched off, the slider moves from valve side 12 to valve
side 14. During slider movement, the signal of the sensor switches from “OFF”
to “ON” if connection 2 is connected to connection 1 or connection 4 is
connected to connection 5.
Transport and Storage
The dual valve is packaged to protect it from contamination. Do not remove the packaging until just before assembling the valve.
CAUTION
Danger of injury from falling!
The dual valve can weigh up to 2400 g and cause injury if it falls.
- Always transport the dual valve carefully.
- Wear suitable protective clothing, such as safety shoes.
NOTICE
Dual valve damage due to falling!
If the dual valve falls, the product may be damaged even if no damage is
visible.
- Always transport the dual valve carefully.
- If the dual valve has fallen, it must not be installed.
- Check the packaging when you receive the product. If the packaging is damaged, the dual valve must not be installed.
Storage
NOTICE
Damage to the dual valve due to incorrect storage!
Unfavorable storage conditions can result in corrosion and material
deterioration. The maximum storage period is two years.
- Only store the dual valve in dry, cool, and corrosion-proof environments. Avoid direct sunlight.
- Keep the dual valve in the original or delivery packaging if you do not install it immediately.
- Never use a dual valve that has been stored for longer than two years.
Assembly
WARNING
Danger of injury due to assembly of the product while the system is
running!
Assembly of the product while the system is running can cause major injuries
from moving machinery.
Bring the system mode into a state in which working movements are no longer
possible.
Wait until all moving machine parts come to a standstill, and protect the
system against being switched on.
Danger of injury due to suspended useful loads!
Useful loads that are kept suspended by compressed air pose a danger if they
are not secured before the pressure is switched off in the system.
- Guide the useful loads into a safe position or remove them from the system.
- You may only then switch off the pressure in the relevant section of the system.
The following must be observed during assembly:
- The dual valve is packaged to protect it from contamination. Do not remove the packaging until just before assembling the dual valve.
- All compressed air connections and control elements must remain freely accessible after installation.
- The dual valve must be attached in such a way that it cannot be loosened by jolts, vibrations, or the like.
- The position of the sensor was fixed at the factory and secured with a clamping screw and resin. The sensor must not be replaced or disassembled, or its position changed. The sensor housing (4) is bolted to the valve cover (3) and secured with resin. The sensor housing must not be replaced or disassembled, or its position changed.
- Make sure that the dual valve is only used as described in “Intended use”.
Preparing for installation
Prepare for assembly as follows:
- Stop system operation and protect it against being switched on.
- Return all suspended loads to a statically secure position or remove them from the system.
- If required, exhaust stored compressed air from system parts in the immediate work area.
- Make sure the relevant section of the system is not under pressure or voltage and protect it from being switched on.
- Secure self-turning or other movable system parts before starting assembly.
- Before assembly, check the sensor cable for damage. If the sensor cable is damaged, you must replace the entire valve. In this case, we recommend that the entire dual valve is replaced.
Installing the dual valve
Any mounting orientation may be used with the dual valve.
Assembly consists of the following steps:
- mechanical fastening to the system,
- connection to the compressed air supply of the pneumatic system,
- connecting the sensors
- coil connection.
Mechanically fastening the dual valve to the system
- Mount the base plate on the assembly surface with 4 x M6 fixing screws in a way thatprevents mechanical strain (see for distances of holes).
- Make sure that the dual valve that it cannot be loosened by jolts, vibrations, or the like.
- Install the dual valve in your system in a manner where the pneumatic connections are always accessible (maximum dimensions: 159 mm x 133 mm x 128 mm).
Connecting the compressed air supply
The valves are supplied with compressed air via the base plate.
Make the pneumatic connections as follows:
Connection 1 to the supply pressure,
Connections 2 and 4 and possibly 4 ext to the working connections.
Observe the following for material numbers R422003189–192: If connection 4 ext is not used, connections 4 and 4 ext must be connected to allow dual duct exhaust.
Connections 5 (1–7, 2–7) are equipped with a silencer at the factory.
WARNING
Danger of injury!
Electric shock due to incorrect power pack!
- Only use the following power supply for the dual valve: 24 V DC PELV circuits in accordance with DIN EN 60204-1.
- The PELV power source must be a safety isolation transformer in accordance with IEC 61558-1 or IEC 61558-2-6, or a power source offering the same degree of safety as a safety isolation transformer.
- Make sure that the power supply of the power pack is always less than 300 V AC (outer cable – neutral wire)
Connect the sensor
The contacts on the M8x1 connection have the following pin assignment (see 8)
Contact | Pin assignment acc. to EN 60947-5-2:1998 |
---|---|
Pin 1 | (+) Brown (BN) |
Pin 3 | (-) Blue (BU) |
Pin 4 | (OUT) Black (BK) |
NOTICE
Malfunction due to damaged sensor cable!
If the seal in the sensor plug is missing or defective, protection class IP65
is not achieved.
Make sure that the seals are integrated in the plug and not damaged.
Damage to the sensor due to excessive voltage!
The ST4 sensor may only be operated with 10–30 V DC even if you use 110 V AC
or 230 V AC coils.
Make sure that the ST4 sensor is always operated within the voltage limits.
Connect the sensor plug and the knurled nuts to the controller. See the table for the pin assignment (above).
We recommend using short circuit protection.
Connecting the coil
Fig. shows that the coil can be mounted in a 180° radius in 5 different
positions (0°, 45°, 90°, 135° and 180°).
To connect the coil, you need cables with the following connections:
- An electrical connector according to ISO 440, form A, CN1 series
- or one M2x1 socket, 3-pin, A-coded.
The cable and connectors are not part of the scope of delivery. The pin assignments of the coils are shown in Fig.9 and 10.
Connect the electrical connector or the M12 socket to the coil. Make sure that
the seals have been inserted correctly. Tighten the screw on the coil (form A)
or the knurled nuts to the M12 plug.
Screw tightening torque: 0.4 +0.1 Nm
Commissioning
WARNING
Danger of injury while working on the system!
Working while the system is running can cause major injuries from moving
machinery.
- Maintain a sufficient safety distance to moving machine components.
- Do not work on the system while it is running.
Risk of injury when actuating the manual override!
Uncontrolled movement of the system components!
Before actuating the manual override, make sure that it will not trigger
uncontrolled system movements.
Checking the connections
Before commissioning, make sure that all plugs are correctly connected to ensure protection class IP65.
Function test
Commissioning can be simplified by actuating the valves with the manual override (MO). The MO on the IS12-PD valves is “without detent”. This means that the valve switches to home position when you discontinue actuating the MO.
Checking the “slider position detection” function
Before initial operation, check whether the “slider position detection” function is working properly.
- If the valve is not actuated (electrically or mechanically on the MO), the sensor LED should be lit. The output voltage is applied to pin 4 (OUT).
- If the valve is actuated (electrically or mechanically on the MO), the sensor LED must not be lit. 0 volts are applied to pin 4 (OUT).
Check of redundant safety functions.
SF2: Prevention of unexpected start-up
Checking the “prevention of unexpected start-up” function as follows:
Test | Result | If available |
---|
1. Valve 1:
Not actuated
| Valve 2: Actuated| Working connection: depressurized| Connection 4 ext:
Depressurized
2. Valve 1: Actuated| Valve 2:
Not actuated
| Working connection: Depressurized| Connection 4 ext: Depressurized
3. Valve 1: Actuated| Valve 2: Actuated| Working connection: Pressure
applied| Connection 4 ext: Depressurized
SF1: Safe exhaust
A pressure volume must be available on working connection (2 or 4) that can be
exhausted, such as a cylinder, to test safe exhaust, as shown in figure .
Check the “safe exhaust” function as follows:
Exhaust the working connection
Test | Result | If available |
---|
Pressure must be applied to the working connection, e.g. by pressurizing a
cylinder
1. Valve 1: Not actuated
Valve 2: Not actuated| Working connection: Depressurized| Connection 4 ext:
Closed
Pressure must be applied to the working connection, e.g. by pressurizing a
cylinder
2. Valve 1: Actuated
Valve 2: Not actuated| Working connection: Depressurized| Connection 4 ext:
Closed
Pressure must be applied to the working connection, e.g. by pressurizing a
cylinder
3. Valve 1:
Not actuated
Valve 2:
Actuated| Working connection:
Depressurized| Connection 4 ext:
Closed
You must additionally test the non-return valve for material numbers R422003189–192:
Exhaust of connection 4 ext
Test | Result |
---|
Pressure must be applied to connection 4 ext, e.g. by pressurizing a cylinder
1. Valve 1:
Not actuated
Valve 2:
Not actuated
Working connection 4:
Closed| Connection 4 ext:
Depressurized
If these functions provide other results, see chapter 11 “Care and Maintenance”.
Operation
WARNING
Loss of function if the minimum control pressure is not met!
If the control pressure falls below 3.5 bar, the dual valve can no longer
switch reliably.
- Make sure that the minimum control pressure is always above 3.5 bar.
- For valves with internal pilot, ensure the operating pressure with an appropriate pressure sensor, or the control pressure for valves with external pilot respectively.
Slider position detection malfunction due to magnetic sources!
Slider position detection may malfunction due to magnetic sources. The safety
function is then affected.
Make sure that no magnetic sources are located near the dual valve.
- Select the dual valve switching frequency in such a manner that full exhaust is always achieved before pressurization takes place again.
- Make sure that the operating conditions correspond to the technical data stated in chapter 16, particularly with regard to temperature, pressure, voltage supply, and mechanical and climatic loads.
Care and Maintenance
Cleaning
NOTICE
Damage to the product due to the use of aggressive cleaning agents!
The product can be damaged if washed with a cleaning agent. The chemical
resistance of the dual valve material to such products is not ensured.
Make sure that no cleaning agents come into contact with the dual valve.
Damage to the product due to washing at high pressures and temperatures!
The product will be damaged if you clean it with high pressure and/or at a
high temperature.
Make sure that the product is not cleaned with high pressure and/or at a high
temperature.
Maintenance
WARNING
Risk of injury while working on a running system!
Working while the system is running can cause major injuries from moving
machinery.
Bring the system mode into a state in which working movements are no longer
possible.
Wait until all moving machine parts come to a standstill, and protect the
system against being switched on.
Danger of personal injury due to uncontrolled movements!
You can simplify system maintenance by mechanically actuating the manual
override (MO).
The MO on the IS12-PD valves is “without detent”. This means that the valve
switches to home position when you discontinue actuating the MO.
Make sure that no uncontrolled movements occur in the process
The dual valve is maintenance-free. However, the seals of the valves may age faster under aggressive ambient conditions. Defective seals will lead to pneumatic leaks and non-compliance with the IP65 protection class.
- Check regularly whether all plug connectors are firmly fitted.
- Establish the maintenance intervals according to your ambient conditions and enter them in the system-dependent maintenance plan.
- Observe the system-specific maintenance intervals.
In case of any maintenance requirements, it is advisable to replace the entire dual valve as this is the only way of ensuring a life cycle value for the entire dual valve.
The operator is responsible for determining the maintenance intervals.
Removing the Dual Valve from the System
WARNING
Danger of injury if dual valve disassembled under pressure or voltage!
Uncontrolled movement of the system components!
Make sure that the system is not under pressure or voltage when you
disassemble the valve, coil, electrical connector, or the M8x1 socket.
NOTICE
Contamination during disassembly!
During disassembly, greases or lubricant may escape from the valve.
Make sure that the environment is not contaminated with greases or lubricant
during disassembly.
- Stop system operation and protect it against being switched on.
- Ensure that the useful load has reached a stable position.
- Make sure that the relevant section of the system is not under pressure and protect it against being switched on.
- Remove the electrical connector from the coil.
- Remove the sensor plug from the controller.
- Release the four fixing screws on the dual valve.
This concludes the disassembly.
Disposal
Dispose of the dual valve and any escaping greases and lubricant in accordance with the national regulations in your country.
Troubleshooting
WARNING
Danger of injury by dismantling the dual valve!
Pre-tensioned springs may suddenly be released when dismantling the valve.
- Never disassemble the dual valve or valves.
- Do not attempt to perform any unauthorized repairs.
Check the connections, operating voltage, and working pressure of the relevant system part if malfunctions occur.
Additional help for malfunctions can be found in the following table:
Malfunction | Possible cause | Remedy |
---|---|---|
Dual valve does not switch | Insufficient control pressure | Increase the |
control pressure
Dual valve is very leaky| Disassemble it and send it, together with a
description of the error, to AVENTICS GmbH
Incorrect pin assignment of the electrical connecto| Check and correct the pin
assignment of the electrical connecto
Use pre-assembled connecting cables with electrical connectors
Insufficient voltage| Increase voltage to the minimum voltage value.
Sensor LED not illuminated| Incorrect M8x1 socket pin assignment| Check and
correct the pin assignment Use pre-assembled connecting cables.
Insufficient voltage| Increase voltage to the minimum voltage value
Excessive voltage| Exchange valve
If you are unable to troubleshoot the dual valve malfunction yourself:Disassemble the dual valve as described in chapter “12 Removing the Dual Valve from the System” and send the valve to AVENTICS GmbH. You can find the address on the back of the operating instructions.
Spare Parts and Accessories
The silencers used can be replaced with AVENTICS material number R412010246. To ensure a good hold, the silencer should be screwed in another 5–10° after the initial contact.
Technical Data
Safety relevant data
Service life parameter B1| Please ask AVENTICS for the latest B10
declaration
---|---
Fault exclusion| Change of the output switching position of a IS12-PD valve
(without input signal)
Sound pressure level| 91 dB(A)
Overview of the achievable diagnostic coverage level (DC),categories and PL depending on the safety function and product variant:
SF | Product variant | DC | Category max. | PL max. |
---|---|---|---|---|
SF11) | R422003622–625 | > 99%, both valves position monitored | 4 | e |
R422003189–192 | Non-return valve not monitored | 1 | c | |
SF22) | R422003622–625 | > 99%, both valves position monitored | 4 | e |
R422003189–192 | Non-return valve not monitored | 33) | d3) |
- SF1: Safe exhaust
- SF2: Prevention of unexpected start-up
- There is a fault exclusion for the valve and category 3 and PL d are therefore possible for SF2, including without monitoring the non-return valve. However, please note that the diagnostic coverage level, category and the PL generally also depend on other system components and the control.
Proven component in terms of ISO 13849-1
The dual valve variants can be viewed as proven components in terms of ISO 13849-1 in the area of industrial automation for the functions “safe exhaust” and “prevention of unexpected start-up” under the following conditions, if they are exclusively operated in accordance with all information contained in these operating instructions, especially in compliance with the performance limits and ambient conditions stated in the technical data.
General data
Dimensions (length x width x height)
R422003622–625:
156 mm x 126 mm x 128 mm
R422003189–192:
159 mm x 133 mm x 128 mm
Weight
R422003622–625: 2200 g
R422003189–192: 2400 g
General data
Working pressure min./max.:
1 to 10 bar external pilot
3.5 to 10 bar internal pilot
Control pressure min./max.: 3.5 to 10 bar
Ambient temperature min./max.: 0°C/+50°C
Storage temperature min./max.: 0°C/+50°C
Ambient operating conditions: Max. height above sea level: 1000 m
Permissible medium: Compressed air in accordance with ISO 8573-1 (7; 4; 4)
Max. particle size: 5 μm
Oil content of compressed air: 0-5 mg/m3
The pressure dew point must be at least 15°C below the ambient and medium temperatures and must not exceed 3°C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see the AVENTICS online catalog, chapter “Technical information”.
Mounting orientation: Any
Vibration resistance: ±0.35 mm displacement at 10 Hz–60 Hz, 5 g acceleration
at 60 Hz to 60 Hz
Shock resistance: 30 g with 18 ms duration 3 shocks each direction
IP protection class: IP65
Switching times (at 6.3 bar)
On (1 -> 2 or 1 -> 4) /
Off (2 -> 3 or 4 + 4 ext -> 5)
R422003622–625, R422003189, R422003191:
20 ms/40 ms
R422003190, R422003192:
30 ms/40 ms
Nominal flow for pressurization 1 -> 2 or 1 -> 4: 800 std l/min
Nominal flow for exhaust 2 -> 3 (R422 003 622 – 625) 4 -> 5 (R422 003 189 –
192):
1800 std l/min (including in error case) 1050 std l/min
Nominal flow 4 ext -> 5: 700 std l/min (flow in error case for variants
R422003189– 192)
Electrical data
Max. positive test pulse: 1000 μs
Max. negative test pulse: 700 μs
Relative humidity Max.: 75% at 50°C
Coil, CO1 series (1824210223)
Electrical connection: EN 175301-803, form A
Power supply: 24 V DC ± 10%
Power consumption: 4.4 W
Coil, CO1 series (1824210354)
Electrical connection: EN 61076-2-101, M12x1
Power supply: 24 V DC ± 10%
Power consumption: 4.5 W
Sensor, ST4 series
Electrical connection: M8 with knurled nuts
Min./max. power supply: 10/30 V DC
Max. switching current: 0.1 A
Vibration resistance: 10–55 Hz, 1 mm
Shock resistance: 30 g/11 ms
Voltage drop U at Imax: ≤2.5 V
Type of contact: Electronic PNP
Cable length: 0.3 m
Sensor LED: Yes
Electrical safety: Protection class III
For further technical data, see the catalog pages in the AVENTICS online catalog (see www.aventics.com/pneumatics-catalog).
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>