AVENTICS UPG Parallel Gripper Instruction Manual

October 27, 2023
AVENTICS

Operating instructions
Parallel gripper

UPG
R412026377/2018-01, Replaces:

AVENTICS | UPG | R412026377–BAL–001–AA

About this document

These instructions contain important information on the safe and appropriate assembly, transport, commissioning, operation, maintenance, and disassembly of the gripper and how to remedy simple malfunctions yourself.

  • Read this documentation completely, especially chapter “Basic Safety Instructions”, before working with the gripper.

Basic Safety Instructions

The gripper has been manufactured according to the accepted rules of technology. Even so, there is a risk of injury or damage if the following general safety instructions and the specific warnings given in this instruction manual are not observed.

  • Read all these instructions completely before working with the gripper.
  • Keep these instructions in a location where they are accessible to all users at all times.
  • Always include the assembly instructions when you pass the gripper on to third parties.

Intended use
The gripper is exclusively intended for installation in a machine or system or for combination with other components to form a machine or system. The product may only be commissioned after it has been installed in the machine/system for which it is intended. The gripper and system may only be used under the operating conditions and within the performance limits listed in the technical data.

  • Only use the gripper to grip loads within the scope of its technical data.

Intended use includes having fully read and understood these instructions, especially chapter “Basic Safety Instructions”.

Improper use
Do not use the gripper to crush connections or objects (e.g. pipe or tubing fittings, sheet metal parts).

Personnel qualifications
Assembly, commissioning and operation, disassembly, service (incl. maintenance and care) require basic mechanical, electrical, and pneumatic knowledge, as well as knowledge of the applicable technical terms. In order to ensure operational safety, these tasks may only be carried out by qualified personnel or an instructed person under the direction of qualified personnel. Qualified personnel are those who can recognize possible hazards and institute the appropriate safety measures, due to their professional training, knowledge, and experience, as well as their understanding of the relevant regulations pertaining to the work to be done. Qualified personnel must observe the rules relevant to the subject area.

Safety instructions in this document
In this document, there are safety instructions before the steps whenever there is a danger of personal injury or damage to the equipment. The measures described to avoid these hazards must be followed.
Safety instructions are set out as follows:

SIGNAL WORD
Hazard type and source
Consequences of non-observance
► Measures to avoid these hazards

  • Safety sign (warning triangle): draws attention to the risk
  • Signal word: identifies the degree of hazard
  • Hazard type and source: identifies the hazard type or source
  • Consequences: describes what occurs when the safety instructions are not complied with
  • Precautions: states how the hazard can be avoided Meaning of the signal words

Meaning of the signal words

WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injuries.

NOTICE Indicates that damage may be inflicted on the product or the environment.

The following must be observed:
General information

  • Observe the valid local regulations in the country of use to protect the environment and avoid workplace accidents.
  • Only use AVENTICS grippers that are in perfect working order.
  • Examine the product for obvious defects, such as cracks in the housing or missing screws, caps, or seals.
  • Do not modify or convert the grippers.
  • Only use the device within the performance range provided in the technical data.
  • Do not place any improper mechanical loads on the product under any circumstances. Never use the product as a handle or step. Do not place loose objects on it.

On installation

  • Make sure the relevant system component is not under pressure or voltage before assembling the product or when connecting and disconnecting plugs. Protect the system against being restarted.
  • Lay cables and lines so that they cannot be damaged and no one can trip over them.
  • Before commissioning, make sure that all the seals and plugs for the compressed air connections have been installed correctly and without any damage to prevent fluids and foreign bodies from penetrating the product.

During operation

  • Only authorized personnel are allowed to operate the setting mechanisms of the components or parts, under the proviso that the pneumatic system is used as intended.
  • Only allow persons who are authorized by the system owner to access the system’s direct operating area. This is also valid when the system is standing still.

During service and repairs
Make sure that no line connections, ports, and components are disconnected as long as pressure and voltage are applied in the system. Protect the system against being restarted.

Delivery Contents

The delivery contents include:

  • 1 gripper
  • 1 set of operating instructions
  • 1 Accessory pack:
    • 6 centering sleeves for mounting
    • 2 O-rings for tubeless direct connection
    • 2 blanking screws for tubing connections

Product description

Product identification
UPG-P-…: Double acting
UPG-P-…-NC: Double-acting, closed without pressure, with gripping safety

Performance specifications
The gripper is used in automation technology. It serves to grip loads within the scope of its technical data. The drive media is compressed air.
The gripper is actuated via the compressed air connections:

  • A/a Figures **1** and **2**
  • B/b Figures **1** and **2**

The force of the piston is transferred to the clamping jaws using the wedge hook principle.

1, 2, 6 Device description

  1. Gripper housing
  2. Clamping jaws
  3. Compressed air connection for fittings
  4. Compressed air connection for flange mounting
  5. Through-hole for side gripper mounting
  6. Thread for bottom gripper mounting
  7. Through-hole for top gripper mounting
  8. Spring housing for gripping safety
  9. Sealing air connection
  10. Fixing bore for cylinder pins

Assembly

Assembling the gripper

CAUTION
Risk of injury or damage due to improper assembly!
An incorrectly mounted gripper may result in uncontrolled movements that could injure personnel or damage other system parts. Gripper assembly requires basic mechanical, pneumatic, and electrical knowledge.

  • The gripper may only be assembled by qualified personnel (see “Personnel qualifications”).
  • Make sure that the gripper is securely fastened.

There are various options for gripper assembly:
There are mounting threads with a center hole on the mounting surface that can be used for assembly.

  • **3** On the base
    • 2 mounting threads with center hole C
    • 2 mounting threads D
    • 4 through-holes H
  • **4** On the side
    • Side with 2 through-holes
  1. Tighten the gripper as shown in Fig. **3** or Fig. **4**
    • Use the provided centering rings E (2 pieces) for this.

  2. Tighten the screws. See Fig. **3** or **4** Fig. for the tightening  torque.

Gripper fingers are assembled on the clamping jaws:
Notice: The gripper fingers are not supplied.

  • **5** Gripper fingers can be assembled from the top via 4 through-holes on the clamping jaws.
    • 2 mounting threads with center hole per clamping jaw

Connecting the gripper pneumatics

CAUTION
Danger of injury if assembled under pressure!
Injuries and damage to the device or system components may occur if the pressure is not switched off before beginning assembly.

  • Make sure that the relevant system part is not under pressure before you assemble the product.

There are two options for connecting the gripper pneumatics:

  • **6** Compressed air connection for fittings
    • Connection A = open gripper
    • Connection B = close gripper
    • Connection S = sealing air
  • **7** Compressed air connection for flange mounting (F = flange/G = gripper)
    • Connection a = open gripper
    • Connection b = close gripper
      Variant I: flange mounting on the side
      Variant II: flange mounting on the base

► Connect the pneumatic connections to the gripper as shown in Fig. **6** and Fig. **7**
• Use the provided O-rings K (2 pieces) for this.

8 Assembling the SC4 sensor

  1. Insert the sensor in the C-slot. See Figure
  2. Fasten the sensor as described in the sensor instructions.
    Observe all warnings and information in the sensor instructions.

Positioning the magnetic switch8
Gripper open:

  1. Open the gripper.
  2. Push the magnetic switch 1 **8** (1) into the groove **8** (4) until it connects to the housing.
  3. Slowly pull the magnetic switch 1 8 (1) back until it switches.
  4. Clamp the magnetic switch 1 **8** (1) by pulling the threaded pin **8** (3), in this position into the groove **8** (4).
  5. Test the gripper function by closing and reopening the gripper.

Gripper closed:

  1. Close the gripper.
  2. Push the magnetic switch 2 **8** (2) into the groove **8** (4) in the direction of the gripper center until it switches.
  3. Clamp the magnetic switch 2 **8**(2) by pulling the threaded pin **8** (3), in this position into the groove **8** (4).
  4. Test the gripper function by closing and reopening the gripper.

Part gripped (O.D. gripping):

  1. Clamp the part to be gripped.
  2. Push the magnetic switch 2 **8** (2) into the groove **8** (4) in the direction of the gripper center until it switches.
  3. Clamp the magnetic switch 2 **8** (2) by pulling the threaded pin (3), in this position into the groove **8** (4).
  4. Test the gripper function by closing and reopening the gripper.

Part gripped (I.D. gripping):

  1. Clamp the part to be gripped.
  2. Push the magnetic switch 1 **8** (1) into the groove **8** (4) until it connects to the housing.
  3. Slowly pull the magnetic switch 1 **8** (1) back until it switches.
  4. Clamp the magnetic switch 1 **8** (1) by pulling the threaded pin (3), in this position into the groove **8** (4).
  5. Test the gripper function by closing and reopening the gripper.

Commissioning

CAUTION
Risk of injury or damage!
If the gripper has not been assembled correctly, personnel may be injured and the product or system damaged when the gripper is commissioned.

  • Make sure that the gripper has been assembled by qualified personnel before commissioning it.
  • The gripper may only be commissioned by qualified personnel (see “Personnel qualifications”).

Proceed as follows to commission the gripper:

  1. Before commissioning, make sure that all the connections on the gripper are properly connected and all of the tubing are firmly fitted.
  2. Switch on the operating pressure.

First-time commissioning
Perform a function test if commissioning the system for the first time:

  • Switch the compressed air on at compressed air connection A/a. The gripper opens.
  • Switch the compressed air on at compressed air connection B/b. The gripper closes.

Operation

WARNING
Danger of crushing and shearing between the clamping jaws and gripper fingers!
Persons or extremities may be crushed during operation.
Extremities, such as fingers, may be severed by this.

  • Make sure that no persons are in the hazardous area during operation.
  • Do not reach into the open mechanics or between the clamping jaws.

CAUTION
Danger of injury due to falling or ejected gripper objects!
If the power supply fails, the gripper objects may fall or be ejected (depending on the application).

  • Make sure that no persons are in the hazardous area during operation.
  • Use protective devices to catch any ejected parts (e.g. a protective grid).
  • Install pressure maintenance valves in your system.
  • Install mechanical devices to retain the gripping force.

Gripping safety when the emergency OFF function is actuated!
Grippers with a mechanical gripping safety can still move independently in the stipulated direction after an emergency OFF.

  • Make sure that no persons are in the hazardous area of the gripper.

Service and Repairs

Please use the material numbers listed below to order the accessory packs from AVENTICS.
Contents of the accessory pack:

  • 6 centering sleeves for mounting
  • 2 O-rings for tubeless direct connection
  • 2 blanking screws for tubing connections
Designation Mat. no.
Accessory pack UPG-P-40 R412026315
Accessory pack UPG-P-50 R412026316
Accessory pack UPG-P-64 R412026317
Accessory pack UPG-P-80 R412026318
Accessory pack UPG-P-100 R412026319
Accessory pack UPG-P-125 R412026320
Accessory pack UPG-P-160 R412026321

The addresses of our international agencies are available at www.aventics.com/contact.

Disassembly and Exchange

CAUTION
Danger of injury if disassembled under pressure or voltage!
Injuries and damage to the product or system parts may occur if the pressure and voltage of the system are not switched off before beginning disassembly.

  • Make sure that the relevant system parts are not under pressure or voltage.

Accessories

The required accessories can be found in our online catalog at www.aventics.com/pneumatics-catalog

Disposal

Dispose of the gripper in accordance with your country’s national regulations.

Technical Data

Parameter Unit Limit
Operating medium Compressed air, compressed air quality

according to ISO 8573-1: 7:4:4
Nominal operating pressure| bar| 6
Minimum pressure without gripping force
retention with gripping force retention| bar| 2.5
4.0
Maximum pressure without gripping force
retention with gripping force retention| bar| 8.0
6.5
Pressure range for sealing air| bar| 0.5 … 1

urther technical data can be found in our online catalog at www.aventics.com /pneumatics-catalog.

AVENTICS GmbH
Ulmer Straße 4
30880 Laatzen, GERMANY
Phone +49 (0) 5 11-21 36-0
Fax: +49 (0) 511-21 36-2 69
www.aventics.com
[email protected]

The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can
be derived from our information. The given information does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.
An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration.
Translation of the original operating instructions. The original operating instructions were created in the
German language.
R412026377–BAL–001–AA/2018-01 Subject to modifications. © All rights reserved by AVENTICS GmbH, even and especially in cases of proprietary rights applications. It may not be reproduced or given to third parties without its consent.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AVENTICS User Manuals

Related Manuals