Vent-Axia 408449 Lo Carbon Sentinel Kinetic High Flow
Product Information
Specifications
- Model: Lo-Carbon Sentinel Kinetic High Flow
- Thermal Efficiency: 88-91%
- SFP (Specific Fan Power): 0.52-1.09 W/l/s
- SEC Rating: Class A
- Static Pressure: 0-1000 Pa
Product Usage Instructions
Increased Performance
The Sentinel Kinetic High Flow is designed with a high efficiency, backward
curved impeller, ensuring the lowest possible energy consumption and
exceptional performance. It can be used in small one-bed apartments to large
houses.
Care Homes & Student Accommodation
The Sentinel Kinetic High Flow is ideal for larger homes, care homes, and
student accommodation. It can extract air from up to fourteen bathrooms and a
communal kitchen while achieving almost 90% heat recovery. The unit is fully
automatic, ensuring adequate ventilation at all times.
Spigot Options
The unit offers 180mm/200mm spigots that can be re-positioned for
horizontal connection or a combination of vertical and horizontal connection.
Quick Change Filter
The unique filter design of the Sentinel Kinetic High Flow allows for easy
access in restricted spaces. The filter folds as you remove it, making it
convenient for systems placed within cupboards.
Integral Humidity Sensor
The integral humidity sensor increases speed in proportion to relative
humidity levels, saving energy and reducing noise. It also reacts to small but
rapid increases in humidity, ensuring adequate ventilation even in the
smallest wet room. The night time relative humidity setback feature suppresses
nuisance tripping.
Models
- Kinetic High Flow Right
- Kinetic High Flow Right with Acoustic Top Box & Enclosure
- Kinetic High Flow Right with Acoustic Top Box
- Kinetic High Flow Right with Acoustic Enclosure
- Kinetic High Flow Left
- Kinetic High Flow Left with Acoustic Top Box & Enclosure
- Kinetic High Flow Left with Acoustic Top Box
- Kinetic High Flow Left with Acoustic Enclosure
Accessories
- Wired Remote Controller
- LED Alarm with 15m cable
- Opto-coupler for volt-free BMS connection
- ISO 45% Coarse (G3) 2x Filter
- ISO ePM10 50% Pollen (M5) 1x Filter
- Anti Vibration Mounts
- Acoustic Purge Fan
- Acoustic Purge Fan XL
FAQ
-
Q: What is the thermal efficiency of the Sentinel Kinetic High Flow?
A: The thermal efficiency ranges from 88% to 91% depending on the model. -
Q: What is the SFP (Specific Fan Power) of the unit?
A: The SFP ranges from 0.52 W/l/s to 1.09 W/l/s depending on the model. -
Q: What is the SEC rating of the unit?
A: The Sentinel Kinetic High Flow has a SEC rating of Class A. -
Q: Can the spigots be re-positioned for different connection options?
A: Yes, the 180mm/200mm spigots can be re-positioned to allow for horizontal connection or a combination of vertical and horizontal connection.
Lo-Carbon Sentinel Kinetic High Flow
- Acoustic Enclosure option for reduced breakout noise
- Acoustic Top Box option for reduced in-duct noise
- Recognized in SAP PCDB
- 180mm/200mm spigots
- Horizontal duct option for space-saving installations
- High airflow, ideal for student accommodation clusters
- Unique folding filter for removal when access is restricted
- Integrated digital controller for simple and accurate commissioning
- Plug and play controls; Humidistat
- BMS connectivity
- LS inputs (Light Switch)
- Volt-free inputs
Increased Performance
The Sentinel Kinetic High Flow benefits from the latest high efficiency,
backward curved impeller design, ensuring the lowest possible energy
consumption, and an exceptional performance range covering small one-bed
apartments to the largest of houses.
For scenarios where noise is a critical issue, an Acoustic Enclosure is
available to reduce breakout noise and the Acoustic Top Box will reduce in-
duct noise at key frequencies.
Care Homes & Student Accommodation
The Sentinel Kinetic High Flow is ideal for larger homes and multiple
occupancy units such as care homes and student accommodation. Capable of
175l/s at 150Pa, the unit can extract from up to fourteen bathrooms and a
communal kitchen while still achieving almost 90% heat recovery. The fully
automatic capability of the Kinetic range means that adequate ventilation is
always achieved.
The Kinetic’s BMS capability is also ideal for those commercial applications
where landlords or property managers want to monitor and optimize building
performance and maintenance. The Kinetic BMS can provide status information
and its self-diagnostics can report if any fault is found.
Spigot Options
180mm/200mm Spigots may be re-positioned to give a horizontal connection or a
combination of vertical and horizontal connection.
Quick Change Filter
As many systems are placed within cupboards the unique filter design folds as
you remove it to ensure easy access in restricted spaces.
Integral Humidity Sensor
The integral humidity sensor increases speed in proportion to relative
humidity levels, saving energy and reducing noise. The sensor also reacts to
small but rapid increases in humidity, even if the normal trigger threshold is
not reached. This unique feature ensures adequate ventilation, even for the
smallest wet room. The night time relative humidity setback feature suppresses
nuisance tripping as humidity gradually increases with falling temperatures.
Models
- Model/Stock Ref
- Kinetic High Flow Right 408449
- Kinetic High Flow Right with Acoustic Top Box & Enclosure 479544
- Kinetic High Flow Right with Acoustic Top Box 479543
- Kinetic High Flow Right with Acoustic Enclosure 479542
- Kinetic High Flow Left 408451
Kinetic High Flow Left with Acoustic Top Box & Enclosure 479547
- Kinetic High Flow Left with Acoustic Top Box 479546
- Kinetic High Flow Left with Acoustic Enclosure 479545
For further details, see Sentinel Kinetic Plus.
Accessories
- Model/Stock Ref
- Wired Remote Controller 443283
- LED Alarm with 15m cable 448356
- Opto-coupler for volt-free bms connection 447340
- ISO 45% Coarse (G3) 2x Filter 403702
- ISO ePM10 50% Pollen (M5) 1x Filter 444201
- Anti Vibration Mounts 68MP033G
- Acoustic Purge Fan 477988
- Acoustic Purge Fan XL 479829
SAP PCDB Test Results
SEC Rating
Dimensions
Unit
Sound Data (Unit only)
Performance
Acoustic Solution
Sound Data (Unit with Acoustic Enclosure)
Tested according to BS EN 13141-7:2010. Breakout quoted spherical. Supply and Extract quoted hemispherical.
Consultant’s Specification
Operation
- The supply and extract ventilation unit shall be as Sentinel Kinetic High Flow as manufactured by Vent-Axia and shall be sized as indicated on the drawings and shall be by the particular specification.
- Supply air to the room shall be pre-heated by the extract air via the integrated composite plastic counterflow heat recovery cell. The Sentinel Kinetic High Flow shall automatically vary the ventilation rate via
- EC/DC motors, as it receives signals from one of the optional interconnected sensors.
- When a signal is received, the fans shall either vary their speed proportionally or on a trickle and boost principle.
- The unit shall have the facility to commission the supply and extract fans individually via in-built minimum and maximum speed adjustment, or alternative wired remote control unit. The fans themselves shall have independent, infinitely variable speed control.
Unit Specification
- The unit shall be manufactured with an ABS outer case construction, and incorporate a reversible core to allow for left or right-hand mounting.
- The unit shall have a high-efficiency composite plastic counterflow heat exchanger, supply and extract filters, automatic summer bypass, integral minimum, and maximum infinitely variable speed controls with facia mounted failure indication.
- The unit shall have low-energy, high-efficiency EC/DC fan/motor assemblies with sealed for-life bearings. The impellers shall be high-efficiency backward curved centrifugal type.
- The unit shall have a heat exchanger cell with a thermal efficiency of up to 92% when tested to EN 308. This shall be protected by ISO 45% Coarse (G3) grade synthetic filters on supply and extract. Complete with a condensate drip tray and drain connection.
- To reduce breakout noise, the MVHR unit shall be provided with an Acoustic Enclosure of steel construction lined with class ‘0’ acoustic foam. To reduce in-duct noise, the top of the MVHR shall be fitted with an Acoustic Top Box to provide attenuation to the 4 ducts of the unit. This Acoustic Top Box shall be of steel construction lined with acoustic class ‘0’ foam with the MVHR spigots linked to the Top Box via 4 separate attenuated ducts. The acoustic enclosure and top box shall each be independently tested for noise to BS EN 13141-7.
- The unit shall be constructed with a removable Core allowing full maintenance access. The removable Core shall provide access to the following:
- Supply and extract filter
- Heat exchanger
- Access to the electrical connections
- Access shall be provided for wiring termination and setup/commissioning. The backlit LCD user interface therein may be duplicated for remote mounting if required.
- Units shall be as manufactured by Vent-Axia Ltd.
- The MVHR unit shall incorporate an Expanded Polystyrene (EPS) inner chassis with custom motor and impeller mounting features. The inner chassis will assist in reducing noise and act as a large anti-vibration mount to avoid transmission through to the back mounting plate or the base of the unit.
- The MVHR unit shall be tested to ensure it meets the maximum allowable vibration of no more than 1mm/s, measured on the unit wall fixing points.
- Sound tested to BS EN 13141-7:2010
Standard Controls
All Sentinel Kinetic units shall incorporate the following functions integrally mounted, pre-wired, and factory fitted by the manufacturer:
- Integral infinitely variable fan speed control on supply and extract
- Integral min/max ventilation control/set point
- Integral BMS input/output interfaces – control and status indication
- Heating interlocks
- 0-10V proportional speed adjustment
- Volt free contacts
- 24V sensor supply
- Integral on/off or trickle boost function from the remote switch, e.g. PIR occupancy detector
- Fully automatic summer bypass
- Switched Live input with adjustable delay on feature
- Fan failure or component failure indicated via individual fault code display
- Running time counter
- Control panel PIN lock
- Automatic frost protection effective to -20°C
- The unit shall incorporate an integral humidity sensor with the following features:
- Ambient Response; Raises the humidity trigger point as dwelling temperature reduces
- Rapid Response: Monitors the rate of change in humidity and triggers increased airflow even if the humidity trigger threshold is not reached
- Proportional Response; Incrementally increases the fan speed to reduce noise and reduce energy consumption
- The unit shall be controlled by the ‘Sentinel’ control devices (enablers and sensors) as detailed in the schedule or on the drawings.
- Tool free filter access
Mounting Option
Airflow Direction
Electrical Connection
Please note: Electrical connection should be carried out by an appropriately qualified person and in accordance with current wiring regulations.
Trickle to Boost by two lighting circuits or Trickle/Boost Switch
Documents / Resources
|
Vent-Axia 408449 Lo Carbon Sentinel Kinetic High
Flow
[pdf] Owner's Manual
408449 Lo Carbon Sentinel Kinetic High Flow, 408449, Lo Carbon Sentinel
Kinetic High Flow, Sentinel Kinetic High Flow, Kinetic High Flow, High Flow,
Flow
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>