- DELIVERED ITEMS
- Starting-up the machine
- Service connection
- Engine protection
- Operation
- Cleaning / Maintenance
- Technical Data
- Specified Conditions Of Use
- Emergency procedure
- Safety Instructions
- Mains Connection
- Maintenance
- Guarantee
- Inspection and maintenance plan
- Failure removal
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
94667 HWW 3100 K Domestic Water Supply Unit
Instructions Manual
Please read the instructions carefully before starting the machine.
DELIVERED ITEMS
Starting-up the machine
Service connection
Engine protection
The pump must not in any case run without fillings.
Operation
Cleaning / Maintenance
Technical Data
| The domestic water supply unit
---|---
HWW 3100 K
Art. No| 94667
Service connection| 230 V~50Hz
Rated input| 600 W
Max. suction head| 8 m
Max. head of delivery| 35 m
Max. delivered quantity| 3600 l/h
tank capacity| 24 l
Max. Water temperature| 35 °C
Degree of protection| IPX4
Weight| 10 kg
Read and understand the operating instructions before using the appliance.
Familiarise yourself with the control elements and how to use the appliance
properly. Abide by all the safety measures stated in the service manual. Act
responsibly toward third parties.
The operator is responsible for accidents or risks to third parties.
In case of any doubts about connection and operation refer, please to our
customer center
This appliance can be used by children-ren aged 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge
if they have been given supervision or instruction concerning the use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
Specified Conditions Of Use
The pump is designed for pumping clean water only to supply the home with
water and to use it at home, in the garden, courtyard, and in fields.
Respecting technical data and safety precautions.
Do not use this product in any other way than stated for normal use. Not
observing general regulations in force and instructions from this manual does
not make the manufacturer liable for damages.
Do not use the pump at outside temperatures over 40 °C or under 0 °C
The pump is not suited for long-run operation (e.g. as a circulation pump in
ponds or streams).
When used in this manner, its service life is curtailed correspondingly. In
these cases, then, use a time switch to secure sufficient idle periods between
cycles of operation.
Do not leave the pump unattended while in operation in order to prevent
subsequent damages caused by eventual malfunctions. Make sure to disconnect
the device from the grid if you do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the existing water-supply network as a
pressure-boosting device.
Never use the pump as a pool circulation pump.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. If you seek help, state the following pieces of information:
- Accident site,
- Accident type,
- A number of injured persons,
- Injury type(s)
Symbols
| WARNING/CAUTION!
---|---
| WARNING – Read the operating instructions to reduce the risk of injury.
| Unplug the machine before any work on it.
| Cable pulling/transport prohibited
| Staying in the transportation medium prohibited
| Warning against dangerous electric voltage
| Any damaged or disposed of electric or electronic devices must be delivered
to appropriate collection centers.
| CE marking
Safety Instructions
Do not grab the feeder cable, plunge the pump, lift or carry it while it is
connected to the grid!
Unplug the device prior to submersion, upon the termination of operation, in
the course of defect removal, and prior to performing maintenance procedures.
If the pump is in operation, neither people nor animals can be present or
plunged in the pumped liquid (e.g. pools, cellars, etc.).
The temperature of the drained liquid must not exceed +35 °C.
The pump must not in any case run without fillings.
Do not leave the pump unattended while in operation in order to prevent
subsequent damages caused by eventual malfunctions.
Make sure to disconnect the device from the grid if you do not plan on using
it.
If the pump is used in ponds, wells, etc., and appropriate pumping stations,
standards valid for pumps in the given country must unconditionally be
observed.
The user is responsible to third parties if a pump (dumping stations, etc.) is
used.
Check the cable and/or socket for damages before the appliance putting into
operation.
Do not expose the appliance to rain and do not use it in wet or moisture
conditions.
Avoid installing the appliance in wet shafts (risk of short circuit, corrosion
effects)! When using the pump for domestic water supply, always observe the
local regulations of water management authorities and wastewater drainage.
In cold weather, the pumping body motor should not be wrapped in a blanket or
another piece of textile with the intent to prevent the water from freezing.
Mains Connection
Operation is only allowed with a safety switch against stray current (RCD max.
stray current of 30mA).
WARNING! Electric shock! There is a risk of an injury caused by electric
shock!
Before putting it into operation, a qualified electrician must check whether
the electric safety measures required are in place. Any national regulations
in this regard must be complied with.
Electric connection to a socket.
Check the voltage. Technical data given on the type label must correspond with
the electric network voltage.
It is necessary to make sure the connecting socket was not near water and
humidity and that the plug was protected against humidity.
Only use splash-proof extension cables approved for outdoor purposes.
Protect the feeder cable from excessive temperatures, oil, and sharp edges.
Maintenance
Unplug the machine before any work on it
Before using the appliance, perform a visual inspection at all times to make
sure the power cord and the plug, in particular, are not damaged on the
charger.
The appliance must not be used if damaged or if safety equipment is defective.
Replace any worn-out and damaged parts.
Caution! If the power cord of the appliance gets damaged, it must be replaced
by the manufacturer or its customer service or a similarly qualified person to
avoid danger.
Repairs and works specified in these Instructions may only be performed by
qualified authorized staff.
Use only original accessories and original spare parts.
Only a regularly maintained and treated appliance can serve as a satisfactory
aid. Insufficient maintenance and care can lead to unforeseen accidents and
injuries.
To ensure the long service life of the pump seal we recommend rinsing the pump
with clean water in regular intervals.
During winter storage, it is necessary to make sure there is no water in the
appliance as the frost could damage the appliance. Prior to transportation, it
is necessary to unplug the pump from the grid! The device has to be completely
emptied and stored with frost-proof protection. Adhesion of mechanical seals
can be prevented if you rinse the pump with the appropriate oil (for example,
vegetable oil). If necessary, a list of spare parts can be found at
www.guede.com.
Guarantee
The warranty period of 12 months applies to commercial use and 24 months
applies to private use and commences on the day of purchase of the device.
The guarantee solely covers inadequacies caused by material defects or
manufacturing defects. An original payment voucher with the date of the sale
needs to be submitted for any claim in the guarantee period.
The guarantee does not cover any unauthorized use such as appliance
overloading, use of violence, or damage as a result of any unauthorized
interference caused by foreign items. Failing to follow the operating and
assembly instructions and common wear are also not included in the guarantee.
The device has to be checked on a regular basis to ensure perfect functioning.
Let us refer to the fact we do not assume any responsibility – according to
standards in force – for damage eventually caused by our appliances in the
below-mentioned cases: Unprofessional repairs executed by unauthorized service
centers;
- Use in conflict with the designed purpose, or failure to observe the use as designed;
- Pump overload with a continuous run;
- Damage as a result of icing or any other fault caused by climatic influences;
Identical regulations apply for accessory parts. To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).
Important information for the customer
Please be sure to know that returning the product in or after the warranty
period must be made in the original packaging.
Service
Do you have any technical questions? Do you have a complaint? Do you require
spare parts or an operating manual? You can get quick and unbureaucratic
assistance in the Service section on the homepage of our service partner Glide
GmbH & Co. KG (www. guede.com). Please help us to help you. In order to be
able to identify your device in the case of a complaint, our service partner
will require its serial number, article number, and year of manufacture. All
this information can be found on the nameplate.
Tel.: +49 (0) 79 04 / 700-360
Fax: +49 (0) 79 04 / 700-51999
E-Mail: support@ts.guede.com
Inspection and maintenance plan
Time interval | Description | Any other details |
---|---|---|
As needed | Clean the check valve. | Check the check valve function. |
Failure removal
Failures | Causes | Removal |
---|---|---|
The engine does not start | No power supply. Blocked pump wheel | Turn the |
engine shaft with a screwdriver through the fan cover (to release
friction circles sealing that may be stuck together).
The pump does not suck| Missing, loose, or blocked check valve is not in
water.
No water in the pump shell.
Too high suction head.
Air bubbles in the suction pipeline. Connections are not sealed, the pump
sucks air, and the pump is not deaerated.| Fix or clean the check valve.
Immerse the check valve in water. Fill the pump shell with water.
Check the suction head.
Check the tightening of the suction pipeline.
Thermal detector switching the pump off| The pump is overheated and switched
off by the thermal overloading protection.
No electric power supply.
Impurity particles (e.g. pebbles) have settled down in the suction hole.| Let
the device get cool!
Check the power supply.
Disassemble and clean the suction hose, preventing the suction of foreign
substances.
Insufficient amount of water pumped| Too high suction head.
The strainer of the check valve is dirty Water level quickly drops down| Check
the suction head.
Clean the strainer., Position the check valve lower.
Clean the pump and replace worn parts. (qualified workshop)
Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below-mentioned
appliances correspond – at the type of construction being launched – to the
appropriate basic safety and hygienic requirements of EC Directives.
In case of any change to the appliance not discussed with us, the Declaration
expires.
Surpresseur domestiqu
94667 HWW 3100 K
Appropriate EU Directives
Harmonized standards used
EN 60335-1:2012+A11
EN 60335-2-41:2003+A1+A2
EN 62233:2008 AfPS GS 2014:01
EN 55014-1:2006+A1+A2
EN 55014-2:2015
EN 61000-3-2:2014
EN 61000-3-3:2013
Guaranteed sound power level
LWA 81 dB (A)
Measured sound power level
LWA 75.88 dB (A)
Wolpertshausen, 02.06.2021
Managing Director
Güde GmbH & Co. KG, Birkichstraße 6, 74549 Wolpertshausen, Germany
Authorized to compile the technical file
GÜDE GmbH & Co. KG
Birkichstrasse 6
74549 Wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
eMail: info@guede.com
www.guede.com
Read User Manual Online (PDF format)