DIS DCS 6000 Junction Box User Manual
- June 17, 2024
- DIS
Table of Contents
DCS 6000
User Manual
Digital Conference System
JB 6002 Junction Box
JB 6004 Junction Box
DCS 6000 Junction Box
Danish Interpretation Systems
Document version
Printed: 19-11-2004
Name: JB6000.DOC
Version:
Important
Compliancy
The equipment has been tested and found to comply with the limits of the
following standards for digital devices:
- EN55103-1 (Emission)
- EN55103-2 (Immunity)
- FCC rules part 15, class A (Emission)?
This device complies with part 15 of the FCC rules.
Operation is subject to the following conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial or light
industrial environment. The equipment generates, uses, and can radiate radio
frequency energy and if not installed and used in accordance with the user
manual it may cause harmful interference to radio communications.
You are cautioned that any changes or modifications not expressly approved in
this manual could void your authority to operate this equipment.
Installation precautions
Do not install the unit in a location near heat sources such as radiators or
air ducts, or in a place.
exposed to direct sunlight, excessive dust or humidity, mechanical vibration
or shock.
To avoid moisture condensations do not install the unit where the temperature
may rise rapidly.
Cleaning
To keep the cabinet in its original condition, periodically clean it with a
soft cloth. Stubborn stains may be removed with a cloth lightly dampened with
a mild detergent solution. Never use organic solvents such as thinners or
abrasive
cleaners since these will damage the cabinet.
Repacking
Save the original shipping cardboard box and packing material; they will
become handy if you ever have to ship the unit. For maximum protection, re-
pack the unit as originally packed from the factory.
Warranty
The individual units in the DCS 6000 system are minimum covered by 12 months
warranty against defects in materials or workmanship.
Description of the DCS 6000 system
Features
The DCS 6000 system has the following main features:
- Fully digital
- Excellent sound quality
- State of the Art” fully digital integrated interpretation, discussion and voting system offering interpretation, language distribution, conference microphone and voting facilities with attendance check with Chip Card ™.
- New, unique digital DATA and AUDIO bus.
- 39 incoming channels (8 floor channels + 31 interpreted channels) and one Line input.
- 33 distributed channels (2 x floor + 31 interpreted channels)
- The Delegate and Interpreter units are powered and controlled by the CU 6010 Central Unit, which drives up to app. 200 units on 4 chains.
- EX 6010 Extension Units or PS 6000 Power Supplies available if more units are required
- A total of 4000 units (delegate and/or interpreter units) can be connected to the system.
- Using screened CAT5 or CAT5e cabling (FTP or STP) ensuring a very cost effective installation and easy set-up of portable systems
- Firmware in Delegate units, Interpreter Units, Central Units etc. upgradeable through serial PC-connection (RS232 or RS422)
- Can be operated with or without a PC.
- Added functionality and comprehensive features provided by SW 6000 software package running on PC
RS232/RS422 connection on CU 6010 for external operation of the system of a PC
or control system such as AMX or Crestron
The SW 6000 is an optional software package, which expands the functionality
of the DCS 6000 system. The software runs on standard computer technology
(Standard PC with Windows 2000 or XP).
Main features of the SW 6000 are:
- Microphone management
- Mimic panel operation
- Interpretation management
- Voting management
- Message handling
- Agenda handling
- Data stored on SQL data base for easy export/import of data as well as easy links to external databases
- Multi language user interfaces
- Supports different User types with different priorities, user interfaces and control possibilities
- Variety of printing facilities such as speaker’s log, voting results, delegates list etc.
System components
The CU 6010 Central Unit supports all available units in the DCS 6000 series:
Central equipment etc.
EX 6010 | Extension Unit |
---|---|
PS 6000 | Power Supply |
AO 6008 | Audio Output box |
RP 6004 | Repeater for four chains |
JB 6002 | Junction Box with 2 outputs |
JB 6004 | Junction Box with 4 outputs |
Interpreter equipment
IS 6032P | Interpreter Set |
---|---|
IS 6132P | Interpreter Set |
LS 6032P | Interpreter Loudspeaker |
Conference equipment and channel selectors
CS 6032FV/H | Channel Selector (flush mounted) |
---|---|
CS 6032FV/H | Conference Unit (portable) |
CM/DM 6020P | Conference Unit (portable) with XLR microphone connector |
CM/DM 6070P | Conference Unit (portable) with two built-in channel selectors |
CM/DM 6090P | Conference Unit (portable) with two built-in channel selectors |
and XLR microphone connector
CM/DM 6060F| Conference Unit (flush mounted) with one built-in channel
selectors
CM/DM 6510F| Conference Unit (flush mounted) with Chip-card and 3 voting
buttons
CM/DM 6560F| Conference Unit (flush mounted) with one built-in channel
selector, Chip-card and 3 voting buttons
MU 6040C/D| Microphone Unit for use with customised front plate with
Loudspeaker, Microphone and Buttons. Available in Delegate (D) and Chairman
(C) version
AM 6040| Ambient Noise Microphone
Operating instructions
JB 6002/04 Junction Box
General description
The JB 6002/04 Junction Boxes are part of the DCS 6000 system and enables the
DCS-LAN to be split into 2 or 4 I/O buffered ports.
The JB 6002/04 is used to split the DCS-LAN for tap-out connection of a DCS
6000 conference unit.
Features
The main features of the JB 6002/04 are:
- Loop through of the DCS-LAN.
- 2 or 4 independent DCS-LAN tap-out ports.
- Redundancy enhancement as other tap-out ports are unaffected by potential network damage on one tap-out port.
- Enables single cable connection to each unit
- Designed in a small size easy-to-install cabinet.
Connectors JB 6002/04
The JB 6002/04 features the following connectors:
-
Loop through chain
RJ45 connector, 2 pieces
DCS-LAN connectors used for connection to the CU 6000/CU 6010 and for connection to other units with DCS-LAN connectors such as more JB 6002/04.
These connectors have auto termination. -
Unit connector
RJ45 connector, 2 pieces (JB 6002), 4 pieces (JB 6004
Each connector is for connection to one Delegate Unit or one Interpreter Unit
or up to four Channel Selectors. This limitation is because the ‘Unit’
connectors have current limiting devises for the power line.
Maximum cable length on the ‘Unit’ connector: 10 m.
Note: The connected unit must be terminated (either by auto termination or
terminating plug (CS 6032)).
Unused ‘Unit’ connectors of JB 6002/4 do not need termination.
LED Indications on JB 6004
In addition to the above-mentioned connectors, the JB 6004 features the following indications
-
Power LED
This LED lights up when Power is available on the connector next to the LED. -
Outgoing data
This LED lights up, when the Junction Box receives data from the CU 6010 Central Unit (at the ‘Loop Through Chain’). -
Incoming Data
This LED lights up, when the Junction Box received data from the connected Unit(s) (at the ‘Unit’ connector).
System design
There are no settings to be done on the JB 6004 Junction Box.
Regarding the number of units, which can be connected to the CU 6010, please
refer to the CU 6010 User Manual.
Standard use of JB 6002/04
The following typical schematic shows the normal use of JB 6002/04 with
delegate and interpreter units:
Enhanced use of JB 6002/04
The following schematic shows how to use two parallel feeding cables to both
the delegate units and the interpreter units. In case of cable failure, there
will always be units (in the same row or booth), which will work. This
considerably
enhances the redundancy of the system.
Appendix
Technical appendix
Cabling
CAT5
The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened
RJ45 connectors.
EIA 568-B wiring shall be used.
It is important to use only FTP or STP (screened) cables and screened RJ45
connectors and not UTP cable, which is unscreened.
How to wire a CAT5 (EIA 568-B) Cable:
Pin | Function | Connector #1 | Connector #2 |
---|---|---|---|
1 | In-going + | ORG/WHT | ORG/WHT |
2 | In-going – | ORG | ORG |
3 | +48V | GRN/WHT | GRN/WHT |
4 | OV | BLU | BLU |
5 | OV | BLU/WHT | BLU/WHT |
6 | +48V | GRN | GRN |
7 | Outgoing – | BRN/WHT | BRN/WHT |
8 | Outgoing + | BRN | BRN |
Note. If other colour codes are used then the four pairs are connected as follows:
Pair 1: Pin 1 & 2
Pair 2: Pin 3 & 6
Pair 3: Pin 4 & 5
Pair 4: Pin 7 & 8
The phase of the pairs must be correct and the wiring spec. as stated in CAT5
(EIA 568-B) have to be followed.
Note: CAT6 cables can normally only be terminated in sockets (female) and not
in cable plugs.
CAT6 can thus only be used for longer cable draws terminating in wall outlets
or jack patch panels.
Accessories (not supplied)
Cat 5e Connection Cables (AWG24)
EC 6000-..5 Connection Cable 0,5 m………………….10 03 12500
EC 6000-01 Connection Cable 1 m…………………….10 03 13101
EC 6000-02 Connection Cable 2 m…………………….10 03 13201
EC 6000-05 Connection Cable 5 m…………………….10 03 13501
EC 6000-10 Connection Cable 10 m…………………..10 03 14102
EC 6000-20 Connection Cable 20 m…………………..10 03 14202
EC 6000-50 Connection Cable 50 m…………………..10 03 14502
Technical specifications
General
Power consumption …………………………………………..max. 0,5W
Supply voltage for unit’s …………………………………………….. 48V
Temperature to guarantee specified performance …………………………5 Deg C. to 40 Deg C.
(35 to 80% humidity)
Storage temperature …………………….. -20 Deg C. to 60 Deg C. (10 to 80% humidity)
Weight JB 6002 ……………………………………………………… 0,1 Kg
Weight JB 6004……………………………………………………….0,2 Kg
Dimensions JB 6002 (W x H x D) …………….80 x 24 x 102 mm
Dimensions JB 6004 (W x H x D) …………….88 x 47 x 105 mm
Connectors
DCS-LAN loop through………………………………….2 pieces RJ45
DCS-LAN chain (JB 6002)……………………………..2 pieces RJ45
DCS-LAN chain (JB 6004)……………………………..4 pieces RJ45
Specifications are subject to change without notice.
Manual 01 18 04453
Copyright © 2004 Danish Interpretation Systems No part of this publication
may be reproduced or utilised in any form or by any means without permission
in writing from the publisher.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>