INSTALLATION & OPERATING INSTRUCTIONS
Roof Top Unit
Description| Model| Use With Air Distribution Box
Model| Control
Air Conditioner| 457915 B57915 459516 B59516 540315 H540315 540316 H540316
640312 640315 640316| 3314851.000| Integral Mechanical
Read these instructions carefully. These instructions MUST stay with this product.
INTRODUCTION
This air conditioner (hereinafter referred to as “unit” or “product”) is
designed and intended for installation on the roof of a Recreational Vehicle
(hereinafter referred to as RV) during or after the time it is manufactured.
This unit can be installed by one person with brief help from additional
personnel. Use these instructions to ensure a properly installed, and properly
functioning product.
Dometic Corporation reserves the right to modify appearances and
specifications without notice.
DOCUMENT SYMBOLS
Indicates additional information that is NOT related to physical injury.
Indicates step-by-step instructions.
IMPORTANT SAFETY INSTRUCTIONS
This manual has safety information and instructions to help you eliminate or
reduce the risk of accidents and injuries.
A. Recognize Safety Information
This is the safety alert symbol. It is used to alert you to potential physical
injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or
death.
B. Understand Signal Words
A signal word will identify safety messages and property damage messages, and
will indicate the degree or level of hazard seriousness.
Warning indicates a hazardous situation that, if NOT avoided, could
result in death or serious injury.
Caution indicates a hazardous situation that, if NOT avoided, could
result in minor or moderate injury.
Notice is used to address practices NOT related to physical injury.
C. Supplemental Directives
Read and follow all safety information and instructions to avoid possible
injury or death.
Read and understand these instructions before [installing / using / servicing
/ performing maintenance on] this product. Incorrect [installation / operation
/ servicing / maintaining] of this product can lead to serious injury. Follow
all instructions.
The installation MUST comply with all applicable local and national codes,
including the latest edition of the following standards: U.S.A.
-
ANSI/NFPA70, National Electrical Code (NEC)
-
ANSI/NFPA 1192, Recreational Vehicles Code
CANADA -
CSA C22.1, Parts l & ll, Canadian Electrical Code
-
CSA Z240 RV Series, Recreational Vehicles
D. General Safety Messages
Warning Failure to obey the following warnings could result in death or
serious injury:
- This product MUST be [installed / serviced] by a qualified service technician.
- Do NOT modify this product in any way. Modification can be extremely hazardous.
- Do NOT add any devices or accessories to this product except those specifically authorized in writing by Dometic Corporation.
SPECIFICATIONS
A. Table – Unit Data
Model No.| Nominal Capacity (BTU HR) Cooling| Electrical
Rating 120 Vac
60 Hz 1 ph| Compressor
Rated Load
Amps| Compressor
Locked Rotor
Amps| Fan Motor
Rated Load
Amps| Fan Motor
Locked Rotor
Amps| Refrigerant
R-410A
(oz)| Minimum
Wire Size*
12 AWG
Copper
Up to 24′| AC Circuit Protection ***Installer Supplied| Minimum
Generator Size” 1 Unit / 2 Units
---|---|---|---|---|---|---|---|---|---|---
457915.70X| 13,500| 12.| 63.0| 3.| 6.| 18.0| 20 Amp| 3.5 kW / 5.0 kW
457915.71X| 13,500| 12.| 68.0| 3.| 6.| 18.0| 20 Amp| 3.5 kW 15.0 kW
657915.71X| 13,500| 12.| 68.0| 3.| 6.| 18.0| 20 Amp| 3.5 kW 15.0 kW
459516.70X| 15,000| 13.| 66.0| 2.0| 6.| 28.| 20 Amp| 3.5 kW / 5.0 kW
459516.71X| 15,000| 13.| 70.0| 2.0| 6.| 28.| 20 Amp| 3.5 kW / 5.0 kW
659516.71X| 15,000| 13.| 70.0| 2.0| 6.| 18.| 20 Amp| 3.5 kW / 5.0 kW
540315.70X| 13,500| 12.| 63.0| 3.0| 9.| 19.| 20 Amp| 3.5 kW / 5.0 kW
540315.71X| 13,500| 12.| 68.0| 3.0| 9.| 19.| 20 Amp| 3.5 kW 15.0 kW
H540315.72X| 13,500| 13.| 68.0| 3.| 8.0| 20.| 20 Amp| 3.5 kW / 5.0 kW
540316.70X| 15,000| 13.| 66.0| 3.| 8.| 30.| 20 Amp| 3.5 kW / 5.0 kW
540316.71X| 15,000| 13.| 70.0| 3.| 8.| 30.| 20 Amp| 3.5 kW 15.0 kW
H540316.72X| 15,000| 13.| 70.0| 3.| 8.0| 20.| 20 Amp| 3.5 kW / 5.0 kW
640312.80X| 11,000| 12.| 53.0| 3.| 9.| 20.0| 20 Amp| 3.5 kW / 5.0 kW
640312.83X| 11,000| 13.| 63.0| 3.| 9.| 18.0| 20 Amp| 3.5 kW / 5.0 kW
640312C35X| 11,000| 11.| 53.0| 4.| 10.0| 19.0| 20 Amp| 3.5 kW 15.0 kW
640312C85X| 11,000| 12.| 53.0| 3.| 9.| 20.0| 20 Amp| 3.5 kW 15.0 kW
640315.80X| 13,500| 13.| 63.0| 3.| 9.| 18.0| 20 Amp| 3.5 kW / 5.0 kW
640315.83X| 13,500| 13.| 63.0| 3.| 9.| 19.0| 20 Amp| 3.5 kW / 5.0 kW
640315.84X| 13,500| 13.| 63.0| 4.| 9.| 19.0| 20 Amp| 3.5 kW / 5.0 kW
640315C35X| 13,500| 13.| 61.0| 4.| 10.0| 18.| 20 Amp| 3.5 kW / 5.0 kW
640315C75X| 13,500| 13.| 52| 3.| 9.| 15.| 20 Amp| 3.5 kW/ 5.0 kW
640315C85X| 13,500| 13.| 63.0| 3.| 9.| 18.0| 20 Amp| 3.5 kW / 5.0 kW
640316C75X| 15,000| 13.| 52| 3.| 9.| 22.| 20 Amp| 3.5 kW / 5.0 kW
-
For wire length over 24 ft., consult the National Electrical Code for proper sizing.
** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered.
Keep in mind generators lose power at high altitudes and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or Circuit Breaker Required.
B. Roof Requirements- A 14-1/4″ x 14-1/4″ (±1/8″) square opening (hereinafter referred to as “roof opening”) is required for installing this unit. This opening is part of the return air system of the unit and MUST be finished in accordance with NFPA 1192.
- Roof construction with rafters/joists support frames on a minimum of 16 inch centers.
- Minimum of 1.5 inches and maximum of 6 inches distance between roof to ceiling of RV.
INSTALLATION INSTRUCTIONS
A. Choosing Proper Location For Unit
This unit is specifically designed for installation on the roof of an RV. When
determining your cooling requirements, the following should be considered:
- Size of RV;
- Window area (increases heat gain);
- Amount of insulation in walls and roof;
- Geographical location where the RV will be used;
- Personal comfort level required.
- Normal locations-The unit is designed to fit over an existing roof vent opening.
- Other locations-When no roof vent is available or another location is desired, the following is recommended:
a. For one unit installation: The unit should be mounted slightly forward of center (front to back) and centered from side to side.
b. For two unit installations: Install one unit 1/3 and one unit 2/3’s from front of RV and centered from side to side.
It is preferred that the unit be installed on a relatively flat and level roof section measured with the RV parked on a level surface. See table for maximum acceptable tilt.
Model Number| Max Tilt (All Directions)| Model Number| Max
Tilt (All Directions)
---|---|---|---
457915
B57915
459516
B59516
540315| 15°| H540315
540316
H540316| 15°
640312
640315
640316| 8°
After Location Has Been Selected:
c. Check for obstructions in the area where unit will be installed. See (FIG.
1), (FIG. 2), (FIG. 3), (FIG. 4), (FIG. 5) & (FIG. 6).d. Notice Maintain structural
integrity. Otherwise damage to product and/or RV could occur.
The roof must be designed to support 130 pounds when RV is in motion. Normally
a 200 lb. static load design will meet this requirement.
e. Check inside the RV for air distribution box (hereinafter referred to as
“ADB”) obstructions (i.e. door openings, room dividers, curtains, ceiling
fixtures, etc.). See (FIG. 7).
B. Roof Preparation
-
Warning FIRE OR ELECTRICAL SHOCK HAZARD. Make sure there are no obstacles (wires, pipes, etc.) inside RV’s [roof / floor / walls]. Shut OFF gas supply, disconnect 120 Vac power from RV, and disconnect positive (+) 12 Vdc terminal from supply battery BEFORE drilling or cutting into RV. Failure to obey these warnings could result in death or serious injury.
Opening Requirements – Before preparing the ceiling opening, read all of the following instructions before beginning the installation.
If an existing roof vent opening will NOT be used a roof opening MUST be cut through the roof and ceiling of the RV. This opening MUST be located between the roof reinforcing members. -
Roof vent removal
a. Unscrew and remove the roof vent.
b. Remove all caulking compound around opening.
c. Seal all screw holes and seams where the roof gasket will be located. Use a good grade of all weather sealant.
d. If the opening exceeds 14-3/8″ x 14-3/8″, it will be necessary to resize the opening. See “B. Roof Requirements” on page (4).
e. If the opening is less than 14-1/8″ x 14-1/8″, it must be enlarged. See “B. Roof Requirements” on page (4).
3. New opening
a. Carefully mark and cut the required roof opening. See “B. Roof Requirements” on page (4).
b. Notice Maintain structural integrity. Otherwise damage to product and/or RV could occur.
Notice NEVER create a low spot on RV roof. Otherwise, water will pool and could cause a leak.
Using the roof opening as a guide, cut the matching hole in the ceiling. The opening created must be framed to provide adequate support and prevent air from being drawn from the roof cavity.
Framing stock 3/4″ or more in thickness must be used.
Remember to provide an entrance hole for power supplies at the front of the opening. See (FIG.8).
C. Wiring Requirements
- Route a copper, with ground, 120 Vac supply wire from the time delay fuse or circuit breaker box to the roof opening. Use a listed/certified non metallic – sheathed single strand cable. See
“A. Table – Unit Data” on page (4).
If vent fan was removed, the existing wire may be used provided it is of proper type, size, location, and correctly fused.
a. This supply wire must be located in the front portion of the roof opening.
b. The power MUST be on an appropriately sized separate time delay fuse or circuit breaker. See “A. Table – Unit Data” on page (4).
c. Make sure that at least 15″ of supply wire extends into the roof opening. This ensures an easy connection at the junction box.
d. Protect the wire where it passes into the opening with approved method.
D. Placing Unit On Roof
-
Remove the unit from the carton and discard carton.
-
Caution LIFTING HAZARD. Use proper lifting technique and control when lifting product.
Failure to obey this caution could result in injury.
Place unit on the roof. -
Notice Do NOT slide unit. Otherwise, damage to gasket (on bottom of unit) may occur, and could cause a leak.
Lift and place the unit over the prepared opening using the gasket on the unit as a guide. See (FIG. 9). -
Place the ADB kit inside the RV. This box contains mounting hardware for the unit and will be used inside the RV.
This completes the outside work. Minor adjustments can be done from inside the RV if required.
E. Installation Preparation
- Check gasket alignment of the unit over the roof opening and adjust if necessary. Unit may be moved from below by slightly lifting. See (FIG. 10).
- Remove ADB and mounting hardware from carton. See (FIG. 11).
- All models in this manual will use a four (4) bolt pattern for installing the ADB kit.
- Reach up into the return air opening of the unit and pull the unit electrical cord down for later connection. See (FIG. 12).
F. Duct Divider Installation
- Measure the ceiling thickness. See (FIG. 12).
- Cut away the number of rows as indicated in the table below. See (FIG. 13).
H540315, H540316| | 457915, B57915
459516, B59516
540315, 540316
640312, 640315,
640316
---|---|---
Ceiling Thickness| # Of Rows To Cut| Ceiling Thickness
Min.| Max.| Min.| Max.
5.75| 6.25| 0| 6.0| 6.5
5.25| 5.75| 1| 5.5| 6.0
4.75| 5.25| 2| 5.0| 5.5
4.25| 4.75| 3| 4.5| 5.0
3.75| 4.25| 4| 4.0| 4.5
3.25| 3.75| 5| 3.5| 4.0
2.75| 3.25| 6| 3.0| 3.5
2.25| 2.75| 7| 2.5| 3.0
1.75| 2.25| 8| 2.0| 2.5
1.25| 1.75| 9| 1.5| 2.0
- Carefully install the duct divider in the roof opening 5-5/8″ from back of roof opening. See (FIG. 14).
Foil back faces rear of unit.
G. Installing Unit
-
Ceiling Template Installation
a. Plug the 6 pin electrical cord from the top unit into the matching 6 pin connector in the electronic control box. The plug is polarized and will only fit in one direction. See (FIG. 15).b. Install supplied non metallic cable connector in junction box hole cutout. See (FIG. 15) for proper orientation.
c. Route the previously run 120 Vac power supply wire through cable connector and into junction box.
d. Secure 120 Vac power supply by tightening cable connector clamp making sure not to damage wires. See (FIG. 15).
e. Hold the ceiling template up to the roof opening and line up the channel in the ceiling template with the previously installed duct divider. ee (FIG. 16).
f. Hold the ceiling template up to the roof opening and start each mounting bolt, by hand, through the ceiling template and up into the unit base pan. See (FIG. 17) & (FIG. 18). Mounting Bolt Pattern Table See (FIG. 17)Model| Bolt Location
457915| A, D, E & H
B57915| A, D, E & H
459516| A, D, E & H
B59516| A, D, E & H
540315| B, C, F & G
H540315| A, D, E, & H
540316| B, C, F & G
H540316| A, D, E, & H
640312| B, C, F & G
640315| B, C, F & G
640316| B, C, F & G
g. Notice Tighten mounting bolts to correct torque
specifications. Overtightening could damage unit’s base pan or ceiling
template.
Not enough torque will allow an inadequate roof seal, and could cause a leak.
Tighten all four (4) mounting bolts EVENLY within 40 to 50 inch pounds. See
(FIG. 18). H. 120 Vac Power Supply Connection
-
Warning ELECTRICAL SHOCK HAZARD.
Make sure 120 Vac power is disconnected from RV. Failure to obey this warning could result in death or serious injury. -
Warning ELECTRICAL SHOCK HAZARD.
Provide grounding in compliance with all applicable electrical codes. Failure to obey this warning could result in death or serious injury. -
Connect white to white; black to black; using appropriate size connectors. Secure bare copper wire under grounding screw in junction box. See (FIG. 19).
-
Tape the connectors to the supply wire to ensure they don’t vibrate loose.
-
Push the wires into the junction box and install junction box cover. See (FIG. 19).
I. Installing ADB
-
Align ADB with ceiling template. See (FIG. 20) & (FIG. 21).
Front and rear vent doors are supplied loose. Do NOT install them until all screws are installed in step 2 & 3. -
Install two (2) (supplied) sheet metal screws inside return air opening to secure ADB to ceiling template. See (FIG. 22).
-
Install eight (8) (supplied) wood screws inside the front, rear and side doors to secure ADB to ceiling. See (FIG. 22).
-
Install front and rear doors.
-
Place filter in return air vent grille. It may already be installed on some units. See (FIG. 23).
-
Install return air vent grille into the ADB. Slide return air vent grille tab into slot in ADB and rotate up and snap in place. See (FIG. 24).
-
Install the control knobs into the ADB. See (FIG. 25).
-
The unit installation is now complete and is ready for operation. The power supply to the unit may now be turned on.
-
Verify that all features of the installed system work. Please read the following operating instructions before attempting to run the unit.
OPERATING INSTRUCTIONS
A. Controls
- The Selector Switch has (8) positions including “OFF”. This controls fan speeds, cooling modes and optional heating modes of operation. See (FIG. 26).
- The thermostat controls the compressor On/ OFF operation within a temperature range of approximately 65° F and 90° F measured at the ADB inlet.
B. “OFF” Position ( )
- This is to turn unit off.
C. Cooling Operation (Blue Graphic)
- Turn selector switch to cooling (blue graphic).
- Set the thermostat at the desired temperature level.
- Select the fan speed that best satisfies your needs:
a. HIGH COOL: Selected when maximum cool- ing and dehumidification required.
b. MEDIUM COOL: Selected when normal or average cooling required.
c. LOW COOL: Selected when room is at de- sired comfort level and needs to be maintained. Normally this speed is used for night time operation.
The compressor will cycle on and off as cooling is required to maintain the selected temperature level. The fan runs when the compressor is off to help keep the temperature uniform throughout the RV.
Notice Wait at least 2 minutes before restarting the compressor when it
has been manually cycled off with either the selector switch or the
temperature set lever.
Other wise, compressor will quick-cycle and could result in compressor or
supply circuit overload.
D. Heating Operation (With Electric Heater Option Installed).
The heat mode of operation will NOT replace a furnace for heating your RV in
cold weather.
The intent is to remove the chill on cool days or mornings.
- Turn the selector switch to “OPT HEAT”.
- The heat strip will come on and begin heating.
- When desired temperature level in RV is reached, move the selector switch to “OFF” position or “FAN” position.
The rmostat does NOT control the fan/heater ON/OFF cycle.
E. Fan Operation (Black Graphic)
This will circulate the air in your RV without cooling or heating.
- Turn the selector switch to fan (black graphic).
There are three positions to select from (high, medium and low). See (FIG. 26).
F. Center Air Discharge
- Slide lever to open and close. See (FIG. 27).
MAINTENANCE
A. Air Filter
- Periodically (a minimum of every 2 weeks of operation) remove the return air filter located behind the return air vent grille and wash it with soap and warm water, let dry and then reinstall.
NEVER run unit without return air filter in place. This will plug the unit evaporator coil with dirt and may substantially degrade the performance of the unit over time.
B. ADB Housing
- Clean ADB housing and control panel with a soft cloth dampened with a mild detergent. Never use furniture polish or scouring powders.
C. Fan Motor
- The blower motor is factory lubricated and requires no service.
GENERAL INFORMATION
A. Frost Formation On Cooling Coil
Frost on a small portion of the coil is not un usual. Under certain
conditions, ice may form on the evaporator coil. This is indicated by very
cold output at very low air speed and the icing can be seen through the air
inlet hole with the filter removed. If this should occur, inspect the filter
and clean if dirty. Make sure air vents are open and not obstructed. Units
have a greater tendency to frost when the outside temperature is relatively
low. This may be prevented by ad justing the thermostat control knob to a
warmer setting (counter clockwise). Should frosting con tinue, operate on any
FAN ONLY setting until the cooling coil is free of frost; then resume nor mal
operation. If frost condition persist, contact your local service center for
assistance.
B. Heat Gain
The ability of this air conditioner to maintain the desired inside temperature
depends on the heat gain of the RV. Some preventative measures taken by the
occupants of the RV can reduce the heat gain and improve the performance of
the air conditioner. During extremely high outdoor temperatures, the heat gain
of the RV can may be reduced by:
- Parking the RV in a shaded area
- Using window shades (blinds and/or curtains)
- Keeping windows and doors shut or minimizing usage
- Avoid the use of heat producing appliances
Operation on High Fan/Cooling mode will give optimum or maximum efficiency in
high humidity or high outside temperatures.
Starting the air conditioner early in the morning and giving it a “head start”
on the expected high outdoor ambient will greatly improve its ability to
maintain the desired indoor temperature.
For a more permanent solution to high heat gain, accessories like Dometic
outdoor patio and window awnings will reduce heat gain by removing the direct
sun. They also add a nice area to enjoy company during the cool of the
evening.
C. Condensation
The manufacturer of this unit will not be responsible for damage caused by
condensation forming on ceilings, windows, or other surfaces. Air contains
water vapor which condenses when temperature of a surface is below Dew point.
During normal operation this unit is designed to remove a certain amount of
moisture from the air, depending on the size of the space being conditioned.
Keeping doors and windows closed when this air conditioner is in operation
will greatly reduce the chance of condensation forming on interior surfaces.
D. Air Distribution
Each A/C unit operating in cool mode, must have a minimum of 2 distribution
vents, or the quick cool vent and one vent open, to avoid the risk of freezing
coils and improper function.
SERVICE – UNIT DOES NOT OPERATE
If your unit fails to operate or operates improperly, check the following
before calling your service center.
- If RV connected to motor generator, check to be sure motor generator is running and produc- ing power.
- If RV connected to power supply by a land line, check to be sure line is sized properly to run unit load and it is plugged into power supply.
- Check your fuse or circuit breaker to see if it is open. Ensure fuse is not burnt, or circuit break- er is “ON” and not activated.
- After the above checks, call your local service center for further help. This unit must be serviced by qualified service personnel only.
When calling for service, always give the following:
- Unit model and serial number found on the identification label located on base pan of unit bottom. Return air vent grille must be removed from ADB to view.
- ADB model and serial number found on rating plate located on ceiling template. Observe this rating plate through the filter opening.
WIRING DIAGRAMS