VOLTIVE V-1224 22/4 Stranded Alarm Wire Instructions

June 17, 2024
VOLTIVE

VOLTIVE V-1224 22/4 Stranded Alarm Wire

VOLTIVE-V-1224 22-4-Stranded-Alarm-Wire-product

Product Information

Specifications

  • Revision: 2.4
  • Date: 2023-02-10
  • Product #: V-1224
  • 22/4 Stranded In-Wall
  • 22 gauge 4 conductors stranded alarm wire
  • Features 7-strand oxygen-free copper (OFC) conductors and ripcord
  • General Purpose (CL3) fire safety rating for installation in walls and risers (between floors) in residential buildings and in walls in commercial buildings
  • UL Listed
  • Product Link

Standards & Ratings

  • Voltage Rating
  • Temperature Rating
  • Materials & Construction
  • Fire Rating
  • Flame Test
  • Testing Laboratory
  • Direct Burial?
  • Sunlight Resistant?
  • RoHS?

Insulation

  • Colours
  • Material
  • Average Thickness
  • Minimum Thickness
  • Outer Diameter
  • Resistance
  • Dielectric Strength

Part Numbers

  • Part #: V-1224-1
  • Old Part #: V-1083
  • Colour: White
  • Length: 500ft
  • Packaging: Coilpack

Conductors

  • Gauge: 22AWG
  • Count: 4
  • Material: Oxygen Free Copper
  • Outer Diameter: 0.75mm
  • Strand Count: 7
  • Strand Diameter: 0.250mm
  • DC Resistance: 55.40 ohms/km

Jacket

  • Available Colors
  • Material
  • Thickness
  • Minimum Thickness
  • Outer Diameter
  • Minimum Bend Radius
  • Ripcord Printing A
  • Ripcord Printing B

Additional Information

Product Usage Instructions

Installation

  1. Ensure power is turned off before installation.
  2. Plan the route for the wire installation, taking into consideration any obstacles or obstructions.
  3. Measure and cut the wire to the desired length, allowing for extra length for connections.
  4. Strip approximately 1/2 inch of insulation from the ends of the wire.
  5. Connect the wire to the desired terminals or connectors according to the specific requirements of your application.
  6. Secure the wire in place using appropriate clips or fasteners.
  7. Test the connections and ensure proper functionality before covering or concealing the wire.

Maintenance
To maintain optimal performance of the wire, it is recommended to periodically inspect the installation for any signs of damage or wear. If any issues are found, replace the wire as necessary.

Troubleshooting
If you experience any issues with the wire, such as loss of signal or connectivity problems, please follow these troubleshooting steps:

  1. Check all connections to ensure they are secure and properly seated.
  2. Inspect the wire for any visible damage or signs of wear. Replace if necessary.
  3. Test the wire with a known working device to determine if the issue lies with the wire or the connected equipment.
  4. If the issue persists, contact customer support for further assistance.

Safety Precautions

  • Always follow local electrical codes and regulations when installing or working with the wire.
  • Ensure the power is turned off before making any connections or modifications to the wire.
  • Avoid exposing the wire to excessive heat, moisture, or direct sunlight, as it may affect its performance and durability.
  • Keep the wire away from sharp objects or abrasive surfaces to prevent damage to the insulation.
  • Do not exceed the recommended voltage or current ratings of the wire.

FAQ

  • Q: What is the fire safety rating of the wire?
    A: The wire has a General Purpose (CL3) fire safety rating for installation in walls and risers (between floors) in residential buildings and in walls in commercial buildings.

  • Q: Is the wire suitable for outdoor use?
    A: The wire is not designed for direct burial or prolonged exposure to sunlight. It is recommended for indoor use only.

  • Q: Can I use this wire for audio or video applications?
    A: Yes, the wire can be used for various applications including alarm systems, audio systems, and video systems.

  • Q: What is the maximum operating temperature of the wire?
    A: The wire has a temperature rating of 75°C.

Introduction

Product # V-1224

22/4 Stranded In-Wall
22 gauge 4 conductors stranded alarm wire, featuring 7 strand oxygen-free copper (OFC) conductors and ripcord. General Purpose (CL3) fire safety rating for installation in walls and risers (between floors) in residential buildings and in walls in commercial buildings. UL Listed.

https://www.voltive.com/products/voltive-22-4-stranded-alarm-wire.

Standards & Ratings

Voltage Rating 300V
Temperature Rating 75°C
Materials & Construction UL 13
Fire Rating General Purpose (CL3)
Flame Test UL 1685
Testing Laboratory UL
Direct Burial? No
Sunlight Resistant? No
RoHS? Yes

Insulation

Colours Red, Black, White, Green
Material Polyvinyl Chloride (PVC)
Average Thickness 0.20mm ± 0.05mm
Minimum Thickness 0.15mm
Outer Diameter 1.15mm ± 0.10mm
Resistance ≥ 50 megaohms/km
Dielectric Strength 2500V AC for 1 minute

Conductors

Gauge 22AWG
Count 4
Material Oxygen Free Copper
Outer Diameter 0.75mm
Strand Count 7
Strand Diameter 0.250mm
DC Resistance ≤ 55.40 ohms/km

Jacket

Available Colors White
Material Polyvinyl Chloride (PVC)
Thickness 0.40mm ± 0.10mm
Minimum Thickness 0.30mm
Outer Diameter 3.60mm ± 0.30mm
Minimum Bend Radius 20 × diameter (72mm)
Ripcord Cotton
Printing A VOLTIVE 22AWG 4C – E516774-XX (UL) CL3 75C – XXX FT USED

/ XXX FT REMAINING
Printing B| V-1224 – MM/YY – XXX-XXX – VOLTIVE.COM – XXX FT USED / XXX FT REMAINING

Part Numbers

Part #| Old Part #| Color| Length| Packaging| UPC| Weight| L x W x H (in)| Link
---|---|---|---|---|---|---|---|---