Honeywell R856D Fan Center Instruction Manual

June 17, 2024
Honeywell

Honeywell R856D Fan Center

Product Information

Specifications

  • TradeLine Models: R856A, R856B, R856D
  • Primary Power Supply: R856A – 24 volts ac, R856B – 120 volts ac, R856D – 120 volts ac
  • Relay Coil Rating: Sealed – 9 va, Inrush – 32 va, Sealed current – 0.375 amp
  • Wiring Terminals: Quick connect and screw type terminals for line voltage loads, screw connections for low voltage wiring
  • Additional Features: Tradeline package with cross-reference label and special instruction sheet

Product Usage Instructions

To use the R856 Fan Centers, follow the steps below:

Step 1: Installation

  1. Ensure that the power supply matches the specifications of the specific model (R856A – 24 volts ac, R856B – 120 volts ac, R856D – 120 volts ac).
  2. Connect the wiring terminals for line voltage loads using the provided quick connect and screw type terminals.
  3. For low voltage wiring, use the screw connections provided.
  4. If using R856B dpst models with No. 8 wire for line voltage loads, connect the quick connect and screw terminals.

Step 2: Fan Control

The R856 Fan Centers are designed to control the operation of an evaporator fan. Follow the instructions below based on your specific model:

R856A Fan Center (spdt fan switching)

This model provides spdt fan switching. Connect the fan to the appropriate terminals based on your desired configuration.

R856B Fan Center (spdt fan switching; includes 45 va transformer)

This model also includes a 45 va transformer to supply low voltage power. Connect the fan to the appropriate terminals based on your desired configuration.

R856D Fan Center (spdt fan switching; includes 45 va transformer and spst thermal delay relay)

This model includes a spst thermal delay relay to prevent short cycling of the compressor motor. Connect the fan to the appropriate terminals based on your desired configuration.

Step 3: Thermostat and Panel Connections

Use the provided low voltage terminal strip for connecting the thermostat and panel.

Step 4: Additional Features

The Tradeline package includes a cross-reference label and a special instruction sheet for easy stocking, handling, and maximum replacement value.

FAQ

What are the available models of the R856 Fan Centers?

The available models are R856A, R856B, and R856D.

What is the primary power supply for each model?

The primary power supply is as follows: R856A – 24 volts ac, R856B – 120 volts ac, R856D – 120 volts ac.

What are the relay coil ratings?

The relay coil ratings are as follows: Sealed – 9 va, Inrush – 32 va, Sealed current – 0.375 amp.

How should I connect the wiring terminals?

For line voltage loads, use the provided quick connect and screw type terminals. For low voltage wiring, use the screw connections.

What are the additional features of the Tradeline package?

The Tradeline package includes a cross-reference label and a special instruction sheet for easy stocking, handling, and maximum replacement value.

R856 FAN CENTERS CONTROL AN EVAPORATOR FAN

  • These fan centers are used with heating cooling thermostats and sub base combinations such as the T87-Q539, T872-Q672, or T834-Q634.
  • All R856 Fan Centers provide line voltage spst, spdt, or dpst switching.
  • R856B and D have an integral 45 va transformer to supply low-voltage power for the system.
  • R856D includes a spst thermal delay relay to prevent short cycling the compressor motor.
  • Low voltage terminal strip for thermostat and panel connections.
  • Case and cover on all models.
  • Models available to control single or two-speed fan motors.
  • Models available with Dpst 20 amp contactor for switching heavy-duty 240v loads.

SPECIFICATION

TRADELINE MODELS

Tradeline models are selected and packaged to provide ease of stocking, ease of handling andmaximum replacement value. Tradeline model specifications are the same as those of standard models except as noted below.

TRADELINE MODELS AVAILABLE:

  • R856A Fan Center-spdt fan switching.
  • R856B Fan Center-spdt fan switching; includes 45 va transformer.
  • R856D Fan Center-spdt fan switching; includes 45 va transformer and spst thermal delay relay.

PRIMARY POWER SUPPLY:

  • R856A—24 volts ac.
  • R856B—120 volts ac.
  • R856D—120 volts ac.

RELAY COIL RATING:

  • Sealed–9 va
  • Inrush—32 va
  • Sealed current—. 375 amp

WIRING TERMINALS: Quick connect and screw type terminals for line voltage loads; screw connections for low voltage wiring.

Standard
screw terminals are for No. 8 wire.

ADDITIONAL FEATURES:

  • Tradeline package with cross reference label and special instruction sheet.

STANDARD MODELS

MODELS:
R856A Fan Center-switching is spst normally open, spdt, or dpst normally open.
R856B Fan Center-switching is spst open, spdt normally open. Includes 45 varmass- former.
R856D Fan Center-switching is spst normally open, spat, or dpst normally open. Transformer and spst thermal delay relay.

ELECTRICAL RATINGS:

Spst and spdt models:

Honeywell-R856D-Fan-Center-FIG-1

TRANSFORMER EXTERNAL LOAD

  • R856 Fan Centres with transformers will operate the following Honeywell relays and contactors with up to 300 feet of No. 18 gauge wire (150 ft. run):

    • two R8230 or R8222 Relays;

    • one R850 Contactor;

    • one R8230 or R8222 Relay and one R850 Contactor;

    • one R850 Contactor and one R8093 Thermal De- lay Relay;

    • one R8210, R8212 or R8214 Contactor;

    • one R8210, R8212 or R8214 Contactor and one
      R8230 or R8222 Relay;

    • one R8210, R8212 or R8214 Contactor and one R8093 Thermal Delay Relay or two R850 Contactors.

WIRING TERMINALS: Color coded leadwires for line voltage loads; screw connections for low volt- age wiring.
Except R856B dpst models which have quick connect and screw terminals for up to No. 8 wire for line voltage loads.

RELAY COIL RATINGS:

Honeywell-R856D-Fan-Center-FIG-2

ORDERING INFORMATION

NUMBER ONE REFER TO THE TRADELINE CATALOG OR PRICE SHEETS FOR COMPLETE ORDERING SPECIFICATION

SPECIFY-

  1. MODEL NUMBER
  2. FAN RELAY SWITCHING.
  3. TRANSFORMER SUPPLY VOLTAGE.
  4. CONTACTOR TERMINAL CONNECTORS NO. 115182, IF NO. 6 WIRE IS TO BE USED.

ORDER FROM

  1. YOUR USUAL SOURCE, OR
  2. HONEYWELL
    1885 DOUGLAS DRIVE NORTH MINNEAPOLIS, MINNESOTA 55422 (IN CANADA-HONEYWELL CONTROLS LIMITED 740 ELLESMERE ROAD SCARBOROUGH, ONTARIO)
    INTERNATIONAL SALES AND SERVICE OFFICES IN ALL PRINCIPAL CITIES OF THE WORLD.

LISTING BODIES: R856A, B and D Fan Centers are listed by Underwriters’ Laboratories, Inc. under File E4436, Guide Number XAPX.

DIMENSIONS: See Fig. 1.

REPAIR PARTS:

Relay-spst and spdt R851E1075
Transformer – 116826A
Contactor —dpst – R850B1617

INSTALLATION

CAUTION

  1.  Installer must be a trained, experienced serviceman.
  2. Disconnect power supply to prevent electrical shock and equipment damage.
  3. Always conduct a thorough checkout when job is complete.

Honeywell-R856D-Fan-Center-FIG-3.

LOCATION AND MOUNTING
The R856 may be mounted on any flat surface or on a standard 4 inch square junction box. Remove the cover by squeezing the sides and pulling straight out- ward. Knockouts for 1/2 or 3/4 inch conduit are pro- vided in the top of the fan center case. When mount-ing on a junction box, run line voltage wires through the slot provided in the back of the case. A 7/8 inch diameter hole for low voltage wiring is located at the bottom of the case. Use the rubber grommet pro- vided to secure the low voltage wires.

Use the case as a template, and punch or drill pilot mounting holes. Mount the R856 on a flat surface or the junction box with two screws provided.

WIRING

CAUTION
Disconnect power supply to prevent electrical shock and equipment damage.
All wiring must comply with local codes and ordinances. Refer to information furnished by the system
or equipment manufacturer and wiring diagrams for typical hookups and internal schematics.
After wiring is complete, place system into operation. Operate through one complete cycle to make sure equipment functions properly.

Honeywell-R856D-Fan-Center-FIG-4

Honeywell-R856D-Fan-Center-FIG-5 Honeywell-
R856D-Fan-Center-FIG-8

HONEYWELL MINNEAPOLI, MINN. 55408 INTERNATIONAL Sales Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A

PRINTED IN U.S.A.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals