KLEIN TOOLS CL1200 AC Clamp Meter Instruction Manual
- June 16, 2024
- KLEIN TOOLS
Table of Contents
KLEIN TOOLS CL1200 AC Clamp Meter
Specifications
Electrical Specifications
DC Voltage Measurement
- Range: 600mV ~ 600V, 1000V
- Resolution: 0.1mV ~ 100mV, 1V
- Overload Protection: 1000V
AC Voltage Measurement
- Range : 600mV ~ 750V
- Resolution: 0.1mV ~ 1V
- Accuracy: RMS Frequency Response: 45 to 400 Hz Minimum Voltage for Frequency Measurement: 200mV Response: Averaging
- Overload Protection : 750V RMS
DC Current Measurement
- Range : 600 ~ 6M, 60M
- Resolution: 0.1 ~ 1k, 10k
- Overload Protection : 600V RMS
AC Current Measurement
- Range:
- Resolution:
- Accuracy:
Resistance Measurement
- Range:
- Resolution:
- Overload Protection:
Capacitance Measurement
- Range:
- Resolution:
- Overload Protection:
Frequency Measurement (Voltage)
- Range:
- Resolution:
- Accuracy:
- Overload Protection:
Duty Cycle Measurement
- Range:
- Resolution:
- Overload Protection:
- Frequency Range:
Diode Test
- Overload Protection Range Test Current:
- Open Circuit Voltage:
Continuity Test
- Overload Protection:
- Open Circuit Voltage:
- Threshold (Approx.):
Product Usage Instructions
AC Voltage Measurement
To measure AC voltage, follow these steps:
- Select the AC voltage measurement function on the device.
- Select the desired range for the measurement.
- Ensure the test leads are properly connected to the circuit being measured.
- Read the voltage value displayed on the LCD screen.
DC Voltage Measurement
To measure DC voltage, follow these steps:
- Select the DC voltage measurement function on the device.
- Select the desired range for the measurement.
- Ensure the test leads are properly connected to the circuit being measured.
- Read the voltage value displayed on the LCD screen.
DC Current Measurement
To measure DC current, follow these steps:
- Select the DC current measurement function on the device.
- Select the desired range for the measurement.
- Ensure the test leads are properly connected to the circuit being measured.
- Read the current value displayed on the LCD screen.
AC Current Measurement
To measure AC current, follow these steps:
- Select the AC current measurement function on the device.
- Select the desired range for the measurement.
- Ensure the test leads are properly connected to the circuit being measured.
- Read the current value displayed on the LCD screen.
Resistance Measurement
To measure resistance, follow these steps:
- Select the resistance measurement function on the device.
- Select the desired range for the measurement.
- Ensure the test leads are properly connected to the circuit being measured.
- Read the resistance value displayed on the LCD screen.
Capacitance Measurement
To measure capacitance, follow these steps:
- Select the capacitance measurement function on the device.
- Select the desired range for the measurement.
- Ensure the test leads are properly connected to the circuit being measured.
- Read the capacitance value displayed on the LCD screen.
Frequency Measurement (Voltage)
To measure frequency of a voltage signal, follow these steps:
- Select the frequency measurement function on the device.
- Select the desired range for the measurement.
- Ensure the test leads are properly connected to the circuit being measured.
- Read the frequency value displayed on the LCD screen.
Duty Cycle Measurement
To measure duty cycle, follow these steps:
- Select the duty cycle measurement function on the device.
- Select the desired range for the measurement.
- Ensure the test leads are properly connected to the circuit being measured.
- Read the duty cycle value displayed on the LCD screen.
Diode Test
To perform a diode test, follow these steps:
- Select the diode test function on the device.
- Connect the diode being tested to the test leads.
- Read the test result displayed on the LCD screen.
Continuity Test
To perform a continuity test, follow these steps:
- Select the continuity test function on the device.
- Connect the test leads to the circuit being tested for continuity.
- Read the test result displayed on the LCD screen.
FAQ
-
Q: What is the maximum voltage for AC voltage measurement?
A: The maximum voltage for AC voltage measurement is 750V RMS. -
Q: What is the maximum voltage for DC voltage measurement?
A: The maximum voltage for DC voltage measurement is 1000V. -
Q: What is the maximum current for DC current measurement?
A: The maximum current for DC current measurement is 6A. -
Q: What is the maximum current for AC current measurement?
A: The maximum current for AC current measurement is N/A.
Instruction Manual
- DATA HOLD
- BACKLIGHT
- WORKLIGHT
- ANALOG
BAR GRAPH
- MAX / MIN
- 3-5/6 DIGIT 5999 COUNT LCD
- AUTO / MANUAL RANGE
- NON CONTACT VOLTAGE TESTER
GENERAL SPECIFICATIONS
The Klein Tools CL1200 is an auto-ranging clamp meter. It measures AC / DC voltage, AC current, resistance, capacitance, frequency and duty cycle. It can also test non-contact voltage, diodes, and continuity.
- Operating Altitude : 2000 meters
- Humidity: 80% max
- Operating Temperature: 32°F to 113°F (0°C to 45°C)
- Storage Temperature: -4°F to 140°F (-20°C to 60°C)
- Dimensions : 7.6″ x 2.6″ x 1.4″ (194 mm x 66 mm x 36 mm)
- Weight : 12 oz. (340 g)
- Calibration : Accurate for one year
- Ingress Protection: IP42
- Drop Protection: 2 m (6 ft.)
- Safety Rating: CATIII 1000V, CAT IV 600V
- Accuracy: ± (% of reading + # of least significant digits)
WARNINGS
To ensure safe operation and service of the tester, follow these
instructions. Failure to observe these warnings can result in severe injury or
death.
- Before each use, verify meter operation by measuring a known voltage or current.
- Never use the meter on a circuit with voltages that exceed the category based rating of this meter.
- Do not use the meter during electrical storms, or in wet weather.
- Do not use the meter or test leads if they appear to be damaged.
- Ensure meter leads are fully seated, and keep fingers away from the metal probe contacts when making measurements.
- Do not open the meter to replace batteries while the probes are connected.
- Use caution when working with voltages above 60V DC, or 25V AC RMS. Such voltages pose a shock hazard.
- To avoid false readings that can lead to electrical shock, replace batteries if a low battery indicator appears.• Unless measuring voltage or current, shut off and lock out power before measuring resistance or capacitance.
- Always adhere to local and national safety codes. Use individual protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
SYMBOLS
FEATURE DETAILS
-
A. Use CAT IV rated leads or higher.
- Do not attempt to measure more than 1000V DC or 750V AC or 2000µA.
-
B. Keep hands below line when measuring high current levels.
-
C. Auto Power-Off (Apo)
- Device will power off after 30 minutes non-use.
- Turn the dial or press a button to wake.
- Disabled during Max / Min function.
- Holding Select button while turning on disables Auto Power-Off.
-
D. Select Functionality Button
- Switch between AC and DC.
- Switch between
- Press for 2 seconds to switch between AC, frequency and duty cycle.
-
E. Hold / Backlight / Worklight
- Press to hold the current input on the display.
- Press again to return to live reading.
- Press for 2 seconds to enable / disable lights.
- Using lights drains the battery significantly.
-
F. Auto / Manual Range
- Press repeatedly to cycle through manual ranges.
- Press for 2 seconds to return to auto ranging mode
- AT is displayed on LCD only during auto ranging mode
-
G. Max / Min Hol
- Press to enter Max / Min mode; the largest and smallest values will be saved while in this mode
- Press repeatedly to alternate between the maximum and minimum readings. Press for 2 seconds to return to live reading and clear the stored maximum and minimum values.
-
H. I. Battery Replacement
- When indicator is displayed on the LCD, batteries must be replaced.
- Remove the back screw and replace 2 x AAA batteries.
-
J. Magnetic Back
- Attach instrument to metal for hands-free use.
-
K. Bar Graph
- The bar graph shows an approximate analog representation of a measurement.
- The bar graph responds much faster than the digital display.
- The scale of the bar graph is zero to the maximum reading of the selected range
FUNCTION INSTRUCTIONS
- AC Current (large): < 600A
- Center wire in guides for best accuracy.
- Opposing currents cancel (use line-splitter when necessary).
- AC / DC Current (small): < 2000µA
- Select AC or DC current source.
- Current above 2000µA will damage instrument.
- AC / DC Voltage: < 750V AC or 1000V DC
- Frequency (Hz) / Duty Cycle (See Feature Details)
- Capacitance: < 6000µF
- Safely discharge capacitor before measurement.
- Reading may take up to 60 seconds for large capacitors.
- Resistance: < 60MΩ
- Do not measure resistance on a live circuit.
- Diode / Continuity
- Diode Features: HOLD MAX/MIN
- Display shows:
- Forward voltage drop if forward biased.
- “O.L.” if reverse biased.
- Continuity Features: HOLD MAX/MIN
- Display shows resistance.
- Buzzer sounds if less than 40Ω.
- Non Contact Voltage (NCV) : > 25V AC
SYMBOLS USED ON LCD
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range | Resolution | Accuracy |
---|---|---|
600mV ˜ 600V | 0.1mV ˜ 100mV | ± (0.5% + 4 digits) |
1000V | 1V | ± (0.8% + 10 digits) |
- Overload Protection: 1000V AC
- Voltage Measurement
Range | Resolution | Accuracy |
---|---|---|
600mV ˜ 750V | 0.1mV ˜ 1V | ± (2.0% + 5 digits) |
- Overload Protection : 750V RMS
- Frequency Response : 45 to 400 Hz
- Minimum Voltage for Frequency Measurement: 200mV Response: Averaging
DC Current Measurement
Range | Resolution | Accuracy |
---|---|---|
600µA | 0.1µA | ± (1.2% + 3 digits) |
2000µA | 1µA |
Overload Protection:
- Voltage: 600V RMS
- Current (leads): 2000µA
AC Current Measurement
Range | Resolution | Accuracy |
---|---|---|
600µA | 0.1µA | ± (2.0% + 5 digits) |
2000µA | 1µA | ± (1.5% + 5 digits) |
60A | 0.01A | ± (2.9% + 15 digits) |
600A | 0.1A | ± (1.9% + 8 digits) |
Overload Protection:
- Voltage : 600V RMS
- Current: (leads) 2000µA (clamp) 600A
- Frequency: 45 to 400Hz
- Minimum Current for Frequency Measurement: 400µA or 20A Minimum Current for Clamp
- Measurement : 0.2A Response: Averaging
- Resistance Measurement
Range | Resolution | Accuracy |
---|---|---|
600Ω ˜ 6MΩ | 0.1Ω ˜ 1kΩ | ± (1.0% + 4 digits) |
60MΩ | 10kΩ | ± (2.0% + 4 digits) |
- Overload Protection : 600V RMS
- Capacitance Measurement
Range | Resolution | Accuracy |
---|---|---|
60nF ˜ 6000µF | 0.01nF ˜ 1µF | ± (3.5% + 6 digits) |
- Overload Protection: 600V RMS
- Frequency Measurement (Voltage)
Range | Resolution | Accuracy |
---|---|---|
99.99Hz ˜ 499.9kHz | 0.01Hz ˜ 100Hz | ± (0.1% + 4 digits) |
- Overload Protection : 600V RMS
- Duty Cycle Measurement
- Sensitivity : 2.5V RMS
Range | Resolution | Accuracy |
---|---|---|
1 ˜ 99% | 0.1% | ± (0.1% + 5 digits) |
- Overload Protection : 600V RMS
- Frequency Range : < 500 Hz
- Sensitivity : 1.2Vpp ~ 50Vpp
Diode Test
Overload Protection| Range| Test Current| Open
Circuit Voltage
---|---|---|---
600V RMS| 6.0V| Appx. 0.25mA| < 1.8V DC
Continuity Test
Overload Protection| Open Circuit Voltage|
Threshold (Appx.)
---|---|---
600V RMS| < 0.44V| <40Ω
Non Contact Voltage Detector
WARRANTY
-
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using a damp cloth. Do not use abrasive cleaners or solvents. -
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the Specifications section, allow the instrument to return to normal operating conditions before using it. -
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items must be properly disposed of in accordance with local regulations.
CUSTOMER SERVICE
- KLEIN TOOLS, INC.
- 450 Bond Street
- Lincolnshire, IL 60069
- 1-877-775-5346
- 139701 Rev. 01/14 B
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>