CONOPU DH-JSD03 Room Humidifier Instruction Manual

June 16, 2024
CONOPU

CONOPU DH-JSD03 Room Humidifier

CONOPU-DH-JSD03-Room-Humidifier-PRODUCT

Thank you for choosing CONOPU! Please read and save these important safety instructions.

READ AND SAVE THESE UK INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

This user manual and any additional inserts are considered part of the product. They contain important information about safety, use and disposal. Before using the product, please familiarize yourself with all operating and safety instructions. Please keep all documents for future reference and pass these documents on together with the product, to any future owner. See our website to view download and print the most current version of this owner’s guide.

INTENDED USE: This product is intended to humidify and circulate the air in indoor living spaces. This product is not intended for commercial or industrial use. The manufacturer assumes no responsibility for damage or injury due to unauthorized use or product modification. Failure to follow these directions will void the product warranty.

WARNING: Risk to Children and Impaired Persons

  • Supervision is required during the installation, operation, cleaning and maintenance of this product by children age 12 and younger and anyone with reduced physical, sensory or mental capabilities. Children should be super-vised to ensure that they do not play with the appliance, its parts and pack-aging material.

INSTALLATION WARNING -TO reduce risk of fire, electrical shock and injury to persons, observe the following:

  • No part of this product (the appliance, power cord, plug, packaging, etc) should be placed near furnaces, fireplaces, stoves or other high-temperature heat sources. Do not use in a window, on an uneven or unstable surface, or near water.
  • The appliance, power supply, power cord and plug cannot come into contact with water. Do not use this product on wet surfaces. Do not use this product in a bathtub or shower or position product where it may fall into a bathtub, laundry, swimming pool or other water container. Do not use this product outdoors or expose it to weather or elements
  • Do not run a cord under the carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route under furniture or appliances. Arrange the cord away from the traffic area and where it will not be tripped over. The cord should not hang over the edges of counters or be placed where it can be crimped or closed in doors. Place the appliance near an easi accessible outlet so the product can be unplugged quickly during an emergency.

SAFE USE WARNING -TO reduces risk of fire, electrical shock and injury to persons, observe the following:

WARNING: To reduce the likelihood of circuit overload, fire and electric shock, do not operate with a solid-state speed device, such as a dimmer control switch

  • Do not operate the unit if the unit has been dropped or damaged. Do not use this product if it has a damaged power cord or plug. To avoid risk of electrical shock, do not attempt to repair or replace parts. Only original replacement parts may be used. If the power cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.
  • Get away from the fire to avoid risk. Your appliance may be equipped with a detachable power supply or a cord or plug with a safety device such as a fuse. Use only the power cord and plug provided.
  • Before plugging a power cord into an electrical outlet, be sure that all electrical information on the rating label, including voltage, is compatible with your outlet’s power supply.
  • Never use the cord as a handle or otherwise yank, strain or stretch the power cord.
  • While the product is plugged in, do not insert or allow foreign objects to enter any input or output opening as this may cause risk of electric shock or fire, or damage the product.
  • A loose fit between the wall outlet (receptacle) and the plug may cause overheating and distortion of the plug. Stopped using the product in this outlet. Contact a qualified electrician to replace loose or worn outlets.
  • This is appliance has a polarized plug (one blade is wider than the other. To reduce the risk of electrical shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
  • Before filling with water, moving, repositioning, servicing, cleaning and when not in use, use the product controls to turn off the power and then unplug. To disconnect from outlet, grasp and pull only the plug. Also power off and unplug if the product will be left unattended for an extended period or during electrical storms.
  • Electric shock can occur when liquid comes in contact with electricity. Be careful when removing the water tank and refilling to avoid electric shock. Do not pour water through the top Outlet Air Grille on the power head.
  • Turn the humidifier off if the relative humidity exceeds 60%. Humidity levels above 60% may allow moisture to build up indoors and condense on surfaces, where microorganisms can settle and grow. For accurate readings, use a hygrometer which is available at most hardware stores and home centers.
  • Be aware that high humidity levels may encourage the growth of biological organisms in the environment.
  • Do not permit the area around the humidifier to become damp. If dampness occurs, turn the output of the humidifier down. If the humidifier’s output of volume cannot be turned down, use the humidifier intermittently. Do not allow absorbent materials, such as carpeting, curtains, drapes, or tablecloths, to become damp.
  • Unplug the appliance during filling and cleaning.
  • Never leave water in the reservoir when the appliance is not in use.
  • Empty and clean the humidifier before storage. Clean the humidifier before the next use.

SERVICING WARNING -TO reduce risk of fire, electrical shock and injury to persons, observe the following:

  • Wash your hands and avoid touching your eyes after handling the wick (filter).
  • Clean your product regularly, only as is instructed in this manual. Before cleaning, turn off the power on your product and unplug it. Do not use gasoline, thinners, solvents or other chemicals for cleaning. Refer to the CLEANING AND  MAINTENANCE instructions provided.
  • Do not open appliance housing while the product is plugged in. To avoid risk of shock, all service and/or repairs must be done by an Authorized Service Center.
  • Protect against the growth of mould, mildew and other microorganisms by empty˜ ing the water tank immediately after each use. lf water is left in the tank for longer than 8 hours, thoroughly clean and disinfect the unit as described in the section of this user manual referenced as “CLEANING AND MAINTENANCE”.

PACKAGE RECYCLING -To reduce waste and environmental harm, observe the following:

  • The packaging protects the appliance from transport damage. The packaging materials are selected from the point of view of environmental friendliness and disposal technology and are therefore recyclable. Dispose of all packaging materials in an environmentally responsible manner.

SAVE THESE INSTRUCTIONS

BEFORE USING THE HUMIDIFIER

Before use, check the appliance for visible damage. DO NOT USE if there is evidence of damage. If any damage is found, contact Consumer Service.

  • Check for Leaks. Damage due to shipping may cause leaks in the Base or Water Tank. A visual inspection may not reveal hairline fractures. Fill the Water Tank with water to inspect for leaks.
  • Please install the product correctly according to the instructions, otherwise, it may cause electrical shock, fire, and injury to persons.
  • If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons to avoid a hazard.
  • The power supply voltage must be consistent with the rated voltage of the product. If does not match, please stop using the unit and contact the dealer.
  • DO NOT plug the humidifier if the installation is not finished.
  • After receiving the humidifier, please place the unit for 30 minutes before using it to prevent damage of the water tank due to the sudden change of temperature.
  • Plug the unit into a suitable socket.
  • DO NOT put metal products, chemicals, or detergents into the sink.
  • DO NOT add water into the mist outlet or air outlet.

WHEN USING THE HUMIDIFIER

  • When moving the unit, please turn off, unplug and empty the water in the water tank.
  • Always place the unit 2m away from the wooden furniture or other appliance
  • Do NOT let water to flow into the bottom from air outlet to avoid damaging the product.
  • Please always place the unit on a smooth, flat surface during using. DO NOT tilt the humidifier.
  • DO NOT put the humidifier near fabrics, lints or hair in order not to block the airflow or other damage to the machine.
  • When using with household gas appliances (gas stoves, gas water heaters etc. ) please keep ventilating.
  • When adding water, DO NOT exceed the max level.
  • Use under 5°C-40°C room temperature.
  • Spills can occur during cleaning, moving or refilling the Water Tank, so be careful to avoid spills when doing these activities.
  • Do not position the humidifier directly blow mist to plants or other objects to avoid damage to items due to excessive humidity.

AFTER USING THE HUMIDIFIER

  • DO NOT unplug by pulling on the cord
  • DO NOT clean the unit or add the water while it is connected to a power source or while it is on.
  • DO NOT disassemble the unit by yourself.
  • Please keep the unit away from heat and direct sunlight.
  • If the room temperature is below 0°, please empty the water in water tank and in sink.
  • Please keep the bottom dry while cleaning.

SPECIFICATIONS

  • Model: DH-JSD03
  • Rated voltage: 220-240V~
  • Rated frequency: 50Hz
  • Rated power: 25W
  • Rated capacity: 4L
  • Rated humidifying capacity: 250ml/h

PRODUCT CONSTRUCTION

CONOPU-DH-JSD03-Room-Humidifier-FIG-1

INSTRUCTIONS FOR USE

  1. Place the machine on a horizontal table. Remove the water tank cover and fill the water tank with pure water at room temperature (you must not fill the mist outlet with water). Cover the water tank with the lid and put the water tank on the machine base. Then connect the machine to a 220-240V~50Hz power supply.

  2. When the adjustment knob is placed in the “off / on” position, the humidifier is power-off, placed in low position, the humidifier is in a power-on condition (red light water shortage standby, green light work).

  3. When the indicator light on the knob turns red, the humidifier is in water shortage, you need to unplug the power plug, fill the water and put the tank on the base, plug in again.

  4. When the indicator light on the knob turns green, the humidifier is working, you can adjust the volume of the mist.

  5. Mist volume adjustment knob was placed in the “max” position, humidifier in a state of maximum amount of mist.

  6. Clockwise rotation of the knob to adjust mist volume from small to large. Adjust the knob to “off / on” to turn off the humidifier.
    NOTE: If the room temperature is too low or the humidity is too high, it is recommended to reduce the mist volume when the mist cannot be fully diffused.

  7. Aroma Diffuser

  8. Lift the water tank

  9. Add essential oil to the indicated position, being careful not to overflowCONOPU-DH-JSD03-Room-Humidifier-FIG-4

CLEANING AND MAINTENANCE

Regular cleaning and maintenance are crucial for optimal air quality and performance of your Top-fill Ultrasonic Humidifier. The cleaning frequency may vary based on usage, water hardness, and environmental factors. It is recommended to thoroughly clean the water tank every 3 days.

TIPS

  1. The water tank and mist guide tube should be cleaned regularly to remove limescale buildup, ideally every 3 days.
  2. The frequency of cleaning can be increased appropriately, especially when algae, mineral deposits or other particles begin to form.
  3. Before cleaning, please make sure to unplug the power supply.
  4. Remove the water tank from base and pour out any remaining water. The water tank and the water reservoir can be wiped with a clean, soft damp cloth. Rinse it with clean water and wipe with the cloth. Please keep the unit dry and then reassemble the humidifier.
  5. When cleaning, please use water instead of any chemicals to avoid damaging the machine and causing safety hazards.
  6. Please consult customer service if you have questions about product cleaning and maintenance.

Cleaning the water tank and mist guide tube
Rinse off with clean water and wipe directly with a clean soft cloth, as in figure 1.

Cleaning the base and atomizer
Add a small amount of vinegar to the base, soak for 10 minutes, then rinse with water and wipe out the limescale/dirt with a soft cloth, as shown in Figure 2.(Be careful not to splash water into the air outlet to prevent any damage to the machine)

TROUBLESHOOTING AND RESOLUTION

NOTICE: If the machine has the following problems, please refer to the cause analysis and follow the instructions, if the problem cannot be solved, please contact the after-sales service.CONOPU-DH-JSD03-Room-Humidifier-
FIG-6

Proper cleaning and maintenance of your Top-fill Ultrasonic Humidifier is essential to the air quality and performance of your humidifier. The frequency in which your humidifier will need to be cleaned will vary depending on use, water hardness and outside environmental factors. It is recommended, assuming average use, to thoroughly clean the unit several times throughout the season, or when algae, mineral deposits or other particles begin to form. Clean the water tank every 3 days.

  • Before cleaning, turn the humidifier off and unplug
  • Remove the water tank from the base and pour out any remaining water. please wipe with a soft cloth.
  • The surface of the humidifier and the water reservoir can be wiped with a clean, soft damp cloth. Keep the unit dry. Reassemble humidifier.
  • ATTENTION: Micro-organisms that may be present in the water or in the environment where the appliance is used or stored, can grow in the water reservoir and be blown in the air causing very serious health risks when the water is not renewed and the tank is not cleaned properly every 3 days
  • ATTENTION: Empty the tank and refill every third day. Before refilling, clean it with fresh tap water or cleaning agents if required by the manufacturer. Remove any scale, deposits, or film that has formed on the sides of the tank or interior surfaces, and wipe all surfaces dry
  • ATTENTION: if the humidifier is not cleaned as recommended, you may experience some growth of algae or bacteria. These microorganisms may become airborne.
  • Note: On occasion, the Water Tank may need to be wiped down or cleaned to remove the build-up of impurities with a mild detergent and cool water.
  • ATTENTION: Do not use gasoline, thinners, solvents or other chemicals for cleaning. The unit may not produce mist at low gear if there is too much dirt in the water reservoir. After cleaning the dirt, you can use it normally. Please do not let water flow into the air outlet during cleaning to avoid damaging your humidifier.
  • ATTENTION: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons to avoid a hazard.

WARRANTY

We appreciate your feedback and will do our best to guarantee your satisfaction. Within 1 year after your purchase, should the product have defects, we will provide a refund or resend you a new one. Please email us with your concern and order number. Your inquiries will be taken care of as soon as possible. This warranty only covers orders from authorized brand online stores and our official website. We are not responsible for any purchases from other distribution channels.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CONOPU User Manuals

Related Manuals