Eaton 9PX3000RT Uninterruptible Power Supply (UPS) User Manual

June 16, 2024
EATON

Eaton 9PX3000RT Uninterruptible Power Supply (UPS)

Eaton-9PX3000RT-Uninterruptible-Power-Supply-UPS-
product

Manual is applicable on the following models:

  • 9PX 700 RT
  • 9PX 1000 RT
  • 9PX 1000GRT
  • 9PX 1500 RT
  • 9PX 1500GRT
  • 9PX 2000 RT
  • 9PX 2200 GRT
  • 9PX 3000 RT
  • 9PX 3000 GRT
  • 9PX 3000 GLRT
  • 9PX EBM 36V RT
  • 9PX EBM 48V RT
  • 9PX EBM 72V RT

SAFETY INSTRUCTIONS

  • SAVE THESE INSTRUCTIONS. This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries.
  • The 9PX models that are covered in this manual are intended for installation in an environment within 0 to 40°C, free of conductive contaminant.
  • This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipmentgenerates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Safety of persons

  • The system has its own power source (the battery). Consequently, the power outlets may be energized even if the system is disconnected from the AC power source. Dangerous voltage levels are present within the system. It should be opened exclusively by qualified service personnel.
    The system must be properly grounded at all times.

  • The battery supplied with the system contains small amounts of toxic materials.

  • To avoid accidents, the directives listed below must be observed:

    • Servicing of batteries should be performed or supervised by personnel knowledgeable about batteries and the required precautions.
    • When replacing batteries, replace with the same type and number of batteries or battery packs.
    • Do not dispose of batteries in a fire. The batteries may explode.
    • Batteries constitute a danger (electrical shock, burns). The short-circuit current may be very high.
  • Precautions must be taken for all handling:

    • Wear rubber gloves and boots.
    • Do not lay tools or metal parts on top of batteries.
    • Disconnect the charging source before connecting or disconnecting battery terminals.
    • Determine if the battery is inadvertently grounded. If inadvertently grounded, remove the source from the ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance (applicable to equipment and remote battery supplies not having a grounded supply circuit).

Product Safety

  • To connect the UPS, instructions, and operations described in the manual must be followed in the indicated order.
  • CAUTION – To reduce the risk of fire, the unit connects only to a circuit provided with 20 or 30 amperes maximum branch circuit overcurrent protection by the National Electric Code, ANSI/NFPA 70 (US installations only).
  • Check that the indications on the rating plate correspond to your AC-powered system and to the actual electrical consumption of all the equipment to be connected to the system.
  • For PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and shall be easily accessible
  • Never install the system near liquids or in an excessively damp environment.
  • Never let a foreign body penetrate inside the system.
  • Never block the ventilation grates of the system.
  • Never expose the system to direct sunlight or a source of heat.
  • If the system must be stored before installation, storage must be in a dry place.
  • The admissible storage temperature range is -25ºC to +55ºC without batteries, 0°C to 40°C with batteries.
  • The system is not for use in a computer room AS DEFINED IN the Standard for the Protection of Information Technology Equipment, ANSI/NFPA 75 (US installations only). Contact Eaton resellers to order a special battery kit, if needed to meet the ANSI/NFPA 75 requirement.

Introduction

  • Thank you for selecting an EATON product to protect your electrical equipment.
  • The 9PX range has been designed with the utmost care.
  • We recommend that you take the time to read this manual to take full advantage of the many features of your UPS (Uninterruptible Power System).
  • Before installing your 9PX, please read the booklet presenting the safety instructions.
  • Then follow the indications in this manual.
  • To discover the entire range of EATON products and the options available for the 9PX range, we invite you to visit our website at www.eaton.com/powerquality or contact your EATON representative.

Environmental protection

  • EATON has implemented an environmental protection policy.
  • Products are developed according to an eco-design approach.

Substances

  • This product does not contain CFCs, HCFCs or asbestos.

Packing

  • To improve waste treatment and facilitate recycling, separate the various packing components.
  • The cardboard we use comprises over 50% of recycled cardboard.
  • Sacks and bags are made of polyethylene.

Frequently Asked Questions

What are the safety instructions for installing and maintaining the Eaton 9PX3000RT UPS?

Safety instructions for installing and maintaining the Eaton 9PX3000RT UPS are provided in the user manual. It's crucial to follow these instructions to ensure safe operation and maintenance of the UPS and batteries.

Is the Eaton 9PX3000RT UPS suitable for residential use?

No, the Eaton 9PX3000RT UPS is not intended for residential use. It is designed for use in commercial environments.

Can I dispose of the used Eaton 9PX3000RT UPS equipment in a regular trash bin?

No, you should not dispose of the used Eaton 9PX3000RT UPS equipment in a regular trash bin. Contact your local recycling or hazardous waste center for proper disposal instructions.

Can the Eaton 9PX3000RT UPS be used in a computer room as defined by the Standard for the Protection of Information Technology Equipment, ANSI/NFPA 75?

No, the Eaton 9PX3000RT UPS is not intended for use in a computer room as defined by the ANSI/NFPA 75 standard. Contact Eaton resellers if you need a UPS that meets this requirement.

Is the Eaton 9PX3000RT UPS environmentally friendly?

Yes, the Eaton 9PX3000RT UPS is designed with environmental protection in mind. It does not contain CFCs, HCFCs, or asbestos.

How do I perform a self-test on the Eaton 9PX3000RT UPS?

To perform a self-test on the Eaton 9PX3000RT UPS, press the self-test button on the UPS front panel. The UPS will run a self-test to check its readiness and battery health.

What is the expected battery life of the Eaton 9PX3000RT UPS, and how frequently should I replace the batteries?

The expected battery life of the Eaton 9PX3000RT UPS depends on usage and environmental conditions. Generally, batteries may need replacement every 3 to 5 years. Monitor battery status and follow the manufacturer's recommendations for replacement.

Can I connect additional battery modules (EBMs) to extend the runtime of the Eaton 9PX3000RT UPS?

Yes, you can connect additional battery modules (EBMs) to extend the runtime of the Eaton 9PX3000RT UPS. This allows you to customize the UPS backup time based on your specific needs.

What is the warranty coverage for the Eaton 9PX3000RT UPS?

The warranty coverage for the Eaton 9PX3000RT UPS includes 1 year of coverage for the UPS and 3 years for the cutting blades. Specific warranty terms may vary, so refer to the warranty documentation for details.

Can the Eaton 9PX3000RT UPS be used with generators or alternative power sources?

Yes, the Eaton 9PX3000RT UPS can be used with generators or alternative power sources, but it's essential to ensure compatibility and consult the user manual for guidelines on proper setup.

Is the Eaton 9PX3000RT UPS compatible with various operating systems and network configurations?

Yes, the Eaton 9PX3000RT UPS is designed to be compatible with a wide range of operating systems and network configurations. It provides flexibility and support for various IT environments.

How can I monitor and manage the Eaton 9PX3000RT UPS remotely?

You can monitor and manage the Eaton 9PX3000RT UPS remotely using Eaton's monitoring and management software solutions. These software tools allow you to check UPS status, receive alerts, and perform remote management tasks.