ONLINE YUNTO series UPS Systems User Manual
- June 16, 2024
- ONLINE
Table of Contents
- ONLINE YUNTO series UPS Systems
- Product Information
- Product Usage Instructions
- Introduction
- Safety warnings
- Installation
- Functions and controls
- Communication and interfaces
- Maintenance
- Troubleshooting
- Support
- Technical data
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ONLINE YUNTO series UPS Systems
Product Information
Specifications
- Manufacturer: ONLINE UPS-Systems S.r.l.
- Model: YUNTO
- Available Models: YUNTO 500 – 800, YUNTO 1200 – 1500
- Country of Origin: Germany, Italy, Switzerland
- Contact Information:
- Germany: Phone +49 (89) 2423990-10, Fax +49 (89) 2423990-20, Website: www.online-usv.de
- Italy: Phone +39 (039) 2051444, Fax +39 (039) 2051435, Website: www.online-ups.it
- Switzerland: Phone +41 (41) 5002868, Fax +49 (89) 242399020, Website: www.online-usv.ch
Product Usage Instructions
Introduction
The YUNTO UPS system is a reliable and efficient power backup solution. This
user manual provides detailed instructions for the installation and
maintenance of the UPS system and batteries. It is essential to read and
follow all the instructions before working with the device.
Safety Warnings
This manual contains important safety instructions that must be followed
during the installation and maintenance of the UPS system and batteries. It is
crucial to read and understand these warnings to ensure safe operation. Keep
the manual in a safe place for future reference.
CAUTION Ensure to follow all safety precautions to prevent accidents or damage to the UPS system and batteries.
Installation
Checking the Delivery
Before starting the installation process, carefully check the delivery package
to ensure all components are included. Keep the transport box and packaging
materials for any potential complaints or returns. If any parts of the system
are damaged during transit, notify your supplier within 24 hours. If you
discover concealed damage after accepting the device, file a complaint
immediately.
Unpacking the UPS System
When unpacking the UPS system, be cautious if the ambient temperature is low,
as it may cause condensation inside and outside the casing. Only install the
UPS system when both the inside and outside surfaces are completely dry to
avoid the risk of electric shock. Carefully handle and open the packaged UPS
system, leaving the components in their packaging until installation.
FAQ (Frequently Asked Questions)
-
Q: What should I do if I discover damage to the UPS system after accepting it?
A: If you notice any damage to the UPS system after accepting it, file a complaint for concealed damage immediately. -
Q: Where can I find the contact information for technical support?
A: For technical support and inquiries, refer to the contact information provided in the manual based on your country of residence.
Introduction
- ONLINE USV-Systeme AG (ONLINE) is one of the leading manufacturers of uninterruptible power supplies (UPS). Since 1988, the German company has focussed on the development, production, sale and support of UPS systems. Based on unit numbers sold, ONLINE products are the German number one in the UPS market and internationally recognized because of their top quality and excellent support.
- The power supply often fails when you least expect it. There can also be significant fluctuation in the quality of the power supply. Network problems can lead to the destruction of critical data, data that is not backed up can be lost and hardware damaged. This means expensive repairs and downtime.
- With models from the YUNTO series from ONLINE, you are perfectly prepared for such eventualities. YUNTO protects sensitive applications from data loss and operating downtime, whether they are price-sensitive entry servers or high-end PCs, telephone systems, network peripherals or NAS boxes.
- YUNTO offers the following advantages:
- Compact design
- Silent operation
- Cold start function, starts the UPS system without network volt-age
- Intelligent battery management, self-test and fast charge function
- Surge protection for data and telephone wires
- Alarm function
- USB interface
- Built-in wall mount
- Inc. shutdown, management and monitoring software, Da-taWatch to download for all operating systems
- 2 years warranty incl. battery and 24h advance replacement
Safety warnings
This manual contains important instructions that you must follow during the installation and maintenance of the UPS system and the batteries. Please read all the instructions in the manual before working with the device. Keep the manual in a safe place.
CAUTION
- The UPS system carries life-threatening voltages. All repair and maintenance work must be carried out by customer service personnel.
- The UPS system has its own energy source (batteries). The output of the UPS system can be live even when the UPS system is not connected to a wall outlet.
- In order to reduce the risk of fire or electric shock, the UPS system may only be installed in buildings with controlled temperature and air humidity in which there are no conductive contaminants. The ambient temperature must not exceed 40°C. The UPS system must not be operated near water or in extremely high air humidity (>90%).
- Before transporting the UPS system, make sure that it is disconnected from the power supply and switched off.
- Batteries can pose a risk of electric shock or catch fire as a result of high short-circuit currents. Please take the necessary precautionary measures. Maintenance must be carried out by qualified personnel who are trained in handling batteries and have good knowledge of the necessary precautionary measures, see Chapter 6 Maintenance. Keep unauthorized personnel away from batteries
- Batteries must be disposed of properly. Local regulations must be taken into consideration.
- Batteries must not be burnt. There is risk of explosion.
Installation
Checking the delivery
Keep the transport box and the packaging material for the carrier or sales
point. If parts of the system have been damaged in transit, submit a transport
damage complaint to your supplier within 24 hours. If you only discover damage
after accepting the device, please submit a complain for concealed damage.
Unpacking the UPS system
-
CAUTION
Unpacking the UPS system at a low ambient temperature can lead to the formation of condensation inside and outside the casing. Only install the UPS system if the inside and outside are completely dry (risk of electric shock). -
PLEASE NOTE
Move and open the packaged UPS system carefully. Leave the components in their packaging until they are installed.
To unpack the UPS system and accessories:
- Open the external box and take the accessories packed with the UPS system out.
- Carefully lift the UPS system out of the external box.
- Place the UPS system in a protected, adequately ventilated position that is free of humidity, flammable gasses and corrosion.
- To avoid interference with other devices, make sure to maintain a clearance of at least 20 cm.
Checking the accessories
Installation and setup
The UPS system is delivered fully assembled.
CAUTION
Make sure that the overall rated performance of the load connected does not
exceed the capacity of the UPS system. The power consumption of inductive
loads or laser printers can be very high, please consider this when specifying
your UPS system.
- Connect the load with the UPS system without switching them on.
- Connect the mains connection cable for the UPS system into a socket.
- Press the button on the UPS system until a short beep sounds and the status LED lights up.
- The UPS system is now operating in normal mode and supplying the load with reliable power.
- Switch the loads on one by one.
PLEASE NOTE
- The internal batteries charge up to 90% of their full capacity in less than eight hours. ONLINE recommends charging the batteries for 48 hours after installation or extended periods of non-use.
- The battery charging starts as soon as the UPS system is connected to the supply network and switched on.
Starting in battery mode
- Press the button on the UPS system until a short beep sounds and the status LED lights up.
- The UPS system is starting, the display then shows the battery statues (see Chapter 4 Battery statuses) and supplies the loads connected with reliable power.
- If the display is lit, fix all warnings (see Chapter 7 Trouble-shooting) and restart the UPS system.
Switching off
- Press the off switch on the UPS system. The UPS system switches off.
- Disconnect the mains connection cable of the UPS system from the socket.
Functions and controls
Together with the beeps, the LEDs on the front of the device indicate the operating status of the UPS.
Communication and interfaces
USB interface
To establish communication between the UPS system and a computer, connect the
computer using a suitable data cable (cable provided) to the USB interface on
the UPS system (see Chapter 9.2 Rear view).
The UPS system can then exchange data via the DataWatch software (see Chapter
DataWatch software).
Surge voltage protection for data and telephone lines (DSL /
telephone/fax/network)
The surge protection filters surge voltage from the data and telephone cables.
This involves connecting the incoming cable to the IN connection on the
reverse of the UPS system. Connect the OUT connection to the end device. The
data connection protection cable protects networks with a transfer rate of 10
to 1000 Mbit/s.
DataWatch software
- The YUNTO series is supplied as standard with DataWatch, the comprehensive software solution for shutdown and management of the PC or server system and for monitoring the YUNTO and the power supply network. To ensure you are always working with the latest version of DataWatch, please download it from the download area of www.online-usv.de.
- DataWatch works in the background and is in constant communication with the YUNTO via the USB protocol. The most famous of all functions: Automatic data backup including the shutdown of running applications and the proper shutdown of the whole system using a freely configurable shutdown routine. At the same time, DataWatch has a comprehensive messaging system, time-controlled test routines and event logging.
- DataWatch supports all current operating systems.
- As a client/server application, DataWatch works in networks and on local workstations. Based on an optional RCCMD agent (Remote Con-sole Command), multiple servers connected to a UPS system can be addressed and controlled across the network without additional hardware.
Maintenance
Care and maintenance
-
To ensure a long service life of the system, the area around the UPS system should be kept clean and free of dust. If the area around the system is very dusty, clean the external surfaces of the system with a vacuum cleaner.
-
To ensure a long service life for the batteries, the ambient temperature should not exceed 25°C.
PLEASE NOTE- Before transporting the UPS system, make sure that it is disconnected from the supply network and switched off.
- The service life of a battery varies as a function of how often it is used, the intensity of use and ambient temperature. Batteries that are used beyond their expected service life often have reduced autonomy times. Replace the batteries in good time to ensure the system always runs at optimum performance.
Storage
If you intend to store the UPS system for an extended period, charge the
battery every three months by connecting the UPS system to the supply network
for five hours. The system should be stored in a cool, dry place.
Replacing the batteries
PLEASE NOTE
Do not replace the batteries while the UPS system is in battery mode.
To replace the batteries, the UPS system bust be switched off, disconnected
from the power supply and opened. Batteries cannot be hot-swapped.
CAUTION
- Maintenance work must be carried out by a qualified technician who is familiar with batteries and the necessary safety measures. Do not allow unauthorized personnel to handle the batteries.
- Batteries pose the risk of an electric shock or injury due to high short circuit current. Take the following safety measures:
- remove watches, jewellery and other metal items
- only use tools with insulated handles
- do not place tools or metal components on the batteries
- The batteries must only be replaced with the same number of batteries of the same type.
- Batteries must be properly disposed of. When disposing of batteries, comply with the statutory regulations applicable in your location.
- Batteries must not be burnt. There is risk of explosion.
- Do not open or damage the battery or batteries. Battery acid can damage the eyes and skin and cause poisoning.
- DANGER OF ELECTRIC SHOCK. Never make changes to the battery cabling or connections. Attempting to change the battery cabling yourself could lead to serious injury.
- The batteries of the UPS system are very heavy. Be careful when handling heavy batteries.
Disposing of the old batteries or UPS system
Find out from a local recycling center how the old batteries or the UPS system
should properly be disposed of. Old batteries can also be returned to ONLINE
for disposal free of charge. Please contact Support (see Chapter 8 Support).
CAUTION
- Batteries must not be burnt. There is risk of explosion.
- Batteries must be disposed of properly. Find out about the lo-cal disposal regulations.
- Do not open or damage the battery or batteries. Battery acid can damage the eyes and skin and cause poisoning.
Troubleshooting
The YUNTO is designed for autonomous operation and automatically reports any problems in the display.
Support
- ONLINE USV-Systeme AG (ONLINE) is one of the leading manufacturers of uninterruptible power supplies (UPS). Since 1988, the German company has focussed on the development, production, sale and support of UPS systems. Based on unit numbers sold, ONLINE products are the German number one in the UPS market and internationally recognised because of their top quality and excellent support.
- As a German provider, ONLINE guarantees direct approachability, simple processing and short response times. Comprehensive support is a matter of course – before and after purchase.
- ONLINE sets great store by reliable support and service.
- Free direct advice and support on:
- Software hotline: +49 (89) 242 39 90 – 13
- Hardware hotline: +49 (89) 242 39 90 – 18
- Free 24 h advance exchange
- Interactive UPS configurator online or as app
- 2 years full warranty, optional renewal
- Unbureaucratic 14 day money-back guarantee
- Excellent product availability and wide network of distributors.
Further information: www.online-usv.de
Technical data
Specification
Model | YUNTO 500 | YUNTO 800 | YUNTO 1200 | YUNTO 1500 |
---|---|---|---|---|
Order no. | Y500 | Y800 | Y1200 | Y1500 |
Electrical characteristics
Rated power (VA / W)| 500 / 300| 800 / 480| 1200 / 720| 1500 / 900
Input voltage and tolerance in normal mode| 230V (180 – 270V)
Frequency| 50 / 60Hz (automatic detection) +/-5Hz
Max. input current| 3.3A| 5.2A| 7.8A| 9.7A
Cold-start function| Yes
Output voltage| 230V +/-10%
Output frequency Battery operation| 50 / 60Hz +/-1Hz
Waveform| Simulated sine
Efficiency, Normal operation| >95%
Battery mode| 70%
Power loss, max.| 15W| 24W| 36W| 45W
Connections
Input| 1x IEC320 C14 (10A)
Outputs, 10A| 3x IEC320 C13 (10A)| 3x IEC320 C13 (10A)| 5x IEC320 C13 (10A)|
5x IEC320 C13 (10A)
Batteries
Typ. Autonomy times at
50 and 100% load and pf=0.6
| ****
6 / 3
| ****
6 / 2.5
| ****
6 / 3
| ****
6 / 2.5
Battery type| 1x 12V / 7Ah| 1x 12V / 9h| 2x 12V / 7Ah| 2x 12V / 9Ah
Design| Sealed, maintenance-free, valve-controlled, lead/acid, life expectancy
3 to 5 years in accordance
with EUROBAT
Charge current| 0.5A
Charging time| < 8 hours to 90%
Communication
USB| Yes
Modem / Network
Over-voltage protection
| Yes
Operating conditions, standards and approvals
Operating temperature| 0 – 40°C
Storage temperature| -15 – 50°C
Rel. air humidity| 0 – 90%
Noise level| silent
Safety| EN62040-1: 2008 +A1: 2013
EMC, Performance| EN62040-2: 2006
Approval| CE
Protection class| IP20
Dimensions / Weight
Dimensions (W x H x D)| 80.1 x 177.5 x 232| 90.9 x 238.7 x 282
Weight| 3kg| 3.5kg| 5.4kg| 6.3kg
Rearview
CE confirmation
DECLARATION Of CONFORMITY
Warranty
ONLINE USV-Syteme AG (ONLINE) guarantees that this product will be free of material and production faults for two years from the purchase date. ONLINE’s obligation by this guarantee is restricted to the repair or replacement (at ONLINE’s discretion) of any faulty products. Before warranty claims can be asserted, a Returned Material Authorization (RMA) number must be obtained from customer services. Products must be returned with the postage paid by the sender, a brief description of the problem and evidence of the place and date of purchase. This warranty does not apply to devices damaged by accidents, negligence or misuse or those which have otherwise been altered or modified. Apart from the above exceptions, ONLINE accepts no explicit or tacit warranty, including a guarantee of conventional quality or suitability for a specific purpose. In some jurisdictions, the restriction or exclusion of tacit guarantees is prohibited, which means that the restrictions or exclusions above may not apply to the purchaser.
Irrespective of the above exclusions, ONLINE shall under no circumstances for direct, indirect, specific, auxiliary or subsequent damage caused as a result of the use of this product, even if ONLINE was informed about the possibility of such damage. In particular, ONLINE shall not be liable for costs of whatsoever nature, such as lost profit or revenue, loss of equipment, loss of the use of the device, loss of software or data, replacement costs, third- party claims or other costs. The content is copyright © 2017 by ONLINE USV- Systeme AG. All rights reserved. Unauthorized reproduction in part or in whole is not permitted without consent.
Luise-Ullrich-Strasse 8
82031 Grünwald/ Germany
Telefon +49 (89) 2423990-10
Telefax +49 (89) 2423990-20
info@online-usv.de
www.online-usv.de
References
- ONLINE USV-Systeme AG - USV Anlagen XANTO, ZINTO, YUNTO
- Online Srl - Gruppi di continuità e UPS
- ONLINE USV-Systeme AG - USV Anlagen XANTO, ZINTO, YUNTO
- ONLINE USV-Systeme AG - USV Anlagen XANTO, ZINTO, YUNTO
- ONLINE USV-Systeme AG - USV Anlagen XANTO, ZINTO, YUNTO
- Manual-Hub.com – Free PDF manuals!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>