ergomotion RIO 5.0 Adjustable Base Owner’s Manual
- June 16, 2024
- ergomotion
Table of Contents
- Safety precautions and usage statements
- Parts list
- Base and remote overview
- Quick reference guide
- Installation guide
- Bluetooth Setup
- Remote control
- Pairing remote control
- Connecting strap (optional)
- Syncing two bases (optional)
- Headboard bracket installation guide (optional)
- Battery backup strap (optional)
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Rio 5.0
ADJUSTABLE BASE
OWNER’S MANUAL
Customer Service: 1-888-550-3746
Safety precautions and usage statements
Attention: Important Safety Disclaimers
Read the following information before using this product. Failure to use a
surge protection device could compromise safety or cause product malfunction
and could void the electrical portion of your warranty.
TO REDUCE THE RISK OF SHOCK, BURNS, FIRE OR INJURY:
For optimal safety and operation, plug bed base into a surge protector (not
included). The bed base should only be plugged directly into a wall outlet or
surge protector (strongly recommended). Always unplug the base from the
electrical outlet before servicing any part of the base. To reduce risk of
electric shock, unplug the base before cleaning. To safely disconnect, ensure
the base is in a flat position with all motors off, and unplug from power
source. Keep the power cord away from heated surfaces. Never operate the base
when the air openings are blocked. Keep air openings free of lint, hair and
the like. Do not drop or insert any object into any opening. Discontinue use
of the bed base and contact a qualified service center if: it has a damaged
cord or plug, if it is not working properly, or it has been dropped into
water.
Only use this bed base for its intended use as described in this manual.
Do not use accessories/attachments that are not recommended by the
manufacturer. Close supervision is required when the bed base is used by or
near children, convalescents, disabled persons or pets. Improper connection of
the equipment can result in the risk of electrical shock, electrical fire or
faulty operation of this bed base. If the plug does not fit your outlet,
contact a qualified electrician to install a suitable outlet. Unauthorized
modification or failure to use a wall outlet or surge protector could void the
electrical portion of your warranty.
CHILDREN AND PETS:
Immediately dispose of all packing materials as it may pose a smothering risk
to small children and pets. To avoid injury, it is not advised to allow
children and small pets to play on or under the bed. Children should not
operate the bed base without adult supervision.
SAFETY FEATURES:
Manual operation – If something gets caught in the platform when flattened,
you can manually raise the platform up by lifting at both the head and foot to
relieve pressure and allow for release.
Emergency stop – Stop the motion of the platform by pressing any button on the
remote control .
Power outage – Use the “Emergency Battery Backup Strap” as a temporary power
source to get the base to a desired position. Instructions on how to operate
the Battery Backup Box are on the Emergency Battery Backup page(s).
Child-lockout – This remote control is programmed with a child-lock safety
feature. Information on activation and deactivation of this feature can be
found on the Remote Control page(s) and on the back of your remote control.
PACEMAKERS:
Some products contain Neodymium MAGNETS which may interfere with devices such
as pacemakers, ICD’s and any other device sensitive to magnetic fields. It is
STRONGLY recommended that owners of such medical devices consult their
physician prior to using products that contain Neodymium MAGNETS. It is also
possible that some pacemakers may falsely interpret the optional massage
feature vibrations as movement/exercise. This is a common occurrence with any
product that creates a vibrating movement and may affect the pacemaker. Please
consult your physician before using the massage feature .
IN-HOME USE AND HOSPITAL STANDARDS:
Ergo adjustable bed bases are designed solely for in-home use. This base was
not designed as a hospital bed and is not designed to meet hospital standards.
Do not use this base with TENT TYPE oxygen therapy equipment or near explosive
gases.
ADDITIONAL SAFETY FEATURES
Casters (optional leg accessory) are equipped with locking wheels to prevent
unwanted movement. Even when locked and unable to roll, it is possible for the
casters to slide. Free release head and foot motors are designed to lower the
mattress by retracting only with gravity, never pulling downwards, which
minimizes pinch points
LIFTING/LOWERING MECHANISMS
The lift/lower feature will emit a minimal humming sound during operation.
This is normal. During operation, the lift arm wheels make contact with the
platform support of the base. This contact may result in metal on metal or
metal on plastic contact. This applies slight tension on the moving components
and resonance is reduced to a minimum level. If excessive noise or vibration
is experienced, reverse the movement action (up or down) of the base with the
remote control. This should realign the base’s activating mechanisms to the
proper operational position. In normal base operation, the wheels, which allow
the bed to maintain its distance from the wall, will make contact with the
steel platform supports of the base creating a contact noise. When entering,
exiting or shifting weight on the base, this contact noise may be audible as
the wheels make contact. This is normal.
MATERIALS
Ergo adjustable bases are constructed from various materials including woods,
metals, plastics and fabrics. Tension, pressure or movement applied to the
frame, platform or shroud through general use may create an audible sound.
MASSAGE OPERATION AND LOCATION ENVIRONMENT
The massage feature will emit a tone during operation. This is normal. As the
massage intensity level is increased, the tone will intensify. The volume of
this tone is directly related to the location environment. For example, when
demonstrated in a show room, the surrounding environmental noise will cover
some of the massage noise. However, when installed in a home setting with
wooden floors, carpeted or not, the massage volume will be more noticeable. To
minimize this resonance, place a piece of carpet, or rubber caster cups, under
each leg or caster of the base. It is possible to experience vibration or
noise from the exterior bed frame, headboard brackets, headboards or
footboards if mounting bolts are not firmly tightened.
Levels 1-3 of massage intensity represent the revolutions of the motor per
minute. Level 3 provides the maximum number of RPMs. However, this does not
mean that the feeling of vibration is the strongest. Depending on the mattress
material, thickness, and positioning of the user, the feeling of vibrations
will differ. We encourage the user to find the massage intensity setting that
suits them best. It is important to understand the physics of vibrations. Just
as an engine may run rough during idle, as the RPMs increase, the vibrations
change concurrently.
TOLERANCE
All Ergo adjustable foundations, depending on make and model, are designed and
manufactured to perform and function within designated quality control
parameters. Bases are subject to meticulous and rigorous inspections during
the quality control process to ensure bases will operate within these
standards during normal operating use. Normal operating use is defined as the
following: Adjustable foundation is to be operated with a mattress and load.
Testing procedures require lifetime cycle tests with up to 120kg distributed
load. The angle (designated “α” in figure 1) between the back section and the
flat section for various configurations of the mattress support platform shall
be ± 3°, which translates to a tolerance of up to 1 ½”. The angle (designated
“β” in figure 1) between the flat section and foot section for various
configurations of the mattress support platform shall be ± 3°, which
translates to a tolerance of up to ¾”. Any adjustable foundation deemed to be
within these allocated tolerances is considered to have met the manufacturer’s
quality control standards.
THAT “NEW PRODUCT” SMELL:
Some people notice a slight odor to their new adjustable base—this can come
from our material manufacturing process. This smell is normal and usually
disappears before the product reaches you. Sometimes, however, this smell may
still be noticeable. It usually disappears after a few weeks, providing
adequate ventilation of the product and the environment.
BREAK IN PERIOD:
You can speed up the break-in period by simply spending time in the adjustable
bed through activities such as reading, watching TV or playing with the kids
or grandkids. The extra movement will help the adjustable base respond to
weight and temperature changes. Some of the materials in our adjustable bases
such as the woods, metals and plastics used in the platform, frame and
components are sensitive to moisture content and temperature and may make
sounds in colder environments.
PAIRED OPERATION:
When operating a “paired” split base setup there may be a time latency up to
1.5 seconds between each bases articulation.
WEAR AND TEAR:
Wear and tear is damage that naturally and inevitably occurs as a result of
normal use or aging.
FABRIC CARE:
To prolong the life of your fabric, protect from direct sunlight whenever
possible. For spot cleaning, wipe area with a light damp sponge or vacuum with
a soft brush attachment to remove particles. Keep at a minimum of 30cm (12
inches) away from direct heat sources. For a deeper cleaning, blot liquid
spills with a clean dry cloth. Wipe with a clean cloth dampened with warm
water. Do not wet excessively. A soft bristle brush may be used to remove
ingrained soil. Avoid scratching by gentle brushing. Wipe with a clean cloth
dampened with warm water to remove residues. Dry in shade away from direct
heat. If persistent marks remain visible after cleaning, seek professional
advice.
PRODUCT RATINGS:
The lift motors are not designed to operate continuously for more than [2]
minutes in an [18] minute time period or approximately 10% duty cycle.
Attempting to circumvent or exceed this rating will shorten the life
expectancy of the product and may void the warranty. The massage motors are
not designed to operate continuously for more than 30 minutes at a time.
Please allow the massaging system to rest for 30 minutes after automatic
massage shut off before restarting.
WEIGHT LIMITS:
This product is not rated to support weights in excess of 750 pounds. The base
will structurally support this weight, provided it is evenly distributed
across the bed base. The adjustable base is not designed to support or lift
this amount in the head or foot sections alone. Exceeding this weight
restriction could damage the bed and/or cause injury and will void the
warranty.
SAVE THESE INSTRUCTIONS.
FCC Compliance:
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Parts list
Before discarding the packing materials – ensure all the parts are accounted for.
All electronics and components that need to be installed are located in boxes under the base or attached to the frame.
A) Wireless Remote Control (1)
B) Mattress Retainer Bar (1)*
C) Legs (6)
D) Power Cord (1)
E) Power Supply (1)
F) Sync Cord ‡
G) Battery Backup Strap (1)
(2) 9V Alkaline Batteries (not included)
H) Connecting Strap‡
Misc Parts (not included):
I) Surge Protector
Headboard Bracket Components (Optional):
J) Headboard Bracket (2)†
K) T-Bracket (2) †
L) Long Bolts (8)†
M) Short Bolts (6)†
N) Wingnuts (2)†
O) Washers (2)†
P) Hex Key (1)†
- These items are attached to the base for shipping purposes. Carefully remove from base and set aside.
‡ Only included in Twin Long and Cal King Split bases.
† This is an optional item and can be purchased (1-888-550-3746)
Base and remote overview
Quick reference guide
Not to scale. For illustration purposes only. Read all instructions before beginning installation.
ELECTRONICS OVERVIEW
If installing a split unit, see pages 13-14.
Installation guide
Always use two people when setting up the base.
STEP 1
Place the bed base box in a desired location with the bottom of the box facing
up.
Remove the binding straps and packing materials, making sure not to puncture
the box with any sharp objects.
STEP 2
Remove the bed base from the box. Unfold the bed making sure to keep the
bottom of the bed facing upwards.
STEP 3
To install headboard brackets (sold separately), see instructions on page 13.
Legs are shipped fully assembled. Alternative heights in 3″ increments can be
achieved by removing leg segments.
To install the legs, thread the leg into frame, and tighten by hand. Do not
over tighten.
STEP 4
If installing a split unit, see pages 11-12.
Locate the battery backup strap and install (2) 9V Alkaline batteries (not
included). Store the strap in a convenient location in case of an emergency
power outage.
(For operating instructions see page 14).
STEP 5
Uncoil input power cord (connected to control box’s power port) and plug into
power supply.
STEP 6
Uncoil the power cord and connect to the power supply. Place power supply on
the ground and extend from the base. Ensure that the power supply and all
attached cords are directed toward the desired surge protector.
STEP 7
Carefully flip the base over on to its legs. Important: Two people are
required to move the bed base. Do not drag across the floor. Do not rest frame
on its side, excessive pressure may damage the legs.
STEP 8
Plug the power cord into a power source. A surge protector is recommended.
STEP 9
Ensure batteries are correctly installed in the back of the remote.
Quickly test functions to verify proper setup before placing mattress on base.
Return the base to a flat position before placing the mattress on top.
STEP 10
Insert the ends of the mattress retainer bar into the holes at the foot of the
platform.
Setup is now complete! Test all functions on remote.
Bluetooth Setup
To operate the base from a smart device, the “Ergomotion Sync” application must be downloaded to the desired smart device from the App Store (Apple) or Google Play Store (Android).
STEP 1
Download and open the Ergomotion Sync app on your smart device.
STEP 2
Swipe through the remote control options and select the option that matches
your physical remote.
STEP 3
Click OK when prompted to allow Ergomotion Sync to use Bluetooth on your
device.
If access is not granted, you will be redirected to app settings to enable
Bluetooth.
For assistance setting up a Bluetooth® connection, refer to your smart device’s owners manual or contact the manufacturer directly.
STEP 4
The app will automatically begin to search for nearby adjustable beds to
connect. If more than one bed is found, select the adjustable bed you wish to
connect.
STEP 5
Once you are successfully connected, you will be redirected to the remote page
and you may begin operating your adjustable base.
Remote control
Remote Control arrives paired to the adjustable base. Three (3) AAA batteries are required to operate the remote.
REMOTE FUNCTIONS
A. Head Massage: Cycle through 3 head massage intensities (Low > Medium > High
Off) After 10 minutes, massage timer will automatically turn off.
B. Foot Massage: Cycle through 3 foot massage intensities (Low > Medium > High Off) After 10 minutes, massage timer will automatically turn off.
C. Massage Timer/All Off: The TIMER/ALL OFF button starts massage at level 2. Select a 10, 20 or 30 minute massage interval. Pressing a fourth time will turn off massage.
D. Anti-Snore: Raises the head of the bed slightly to help open airways and reduce snoring.
E. Zero-G®: Preset position that adjusts your legs to a higher level than your heart helping to relieve pressure off the lower back and promote circulation.
F. Lumbar Adjustment: Increases and decreases the lumbar support.
G. Lights: Turn the underbed lights On/Off.
H. Head Articulation: Raises and lowers the head end of the adjustable base.
I. Foot Articulation: Raises and lowers the foot end of the adjustable base.
J. Programmable Presets*: Save a customizable position.
K. Flat: Return the adjustable base to a flat position.
PRESET PROGRAMMING
STEP 1
Articulate the head and foot to your desired position.
STEP 2
Press and hold one of the preset buttons [ ] for 7 seconds. The position is
now saved.
NOTE: To restore the preset buttons back to their original factory
settings, hold FLAT and ZERO-G® simultaneously for at least 5 seconds.
The original presets will be restored.
CHILD LOCK
ACTIVATE CHILD LOCK:
Press and hold FLAT and HEAD UP buttons for 3 seconds. When the backlight on
the remote flashes 2 times, that means the lock is completed.
When a button is pressed in Child Lock mode, the backlight on the remote will
flash twice.
DEACTIVATE CHILD LOCK:
Press and hold FLAT and FOOT UP buttons for 3 seconds. When the backlight on
the remote flashes 2 times, that means the unlock is completed.
The remote will now operate normally.
Pairing remote control
The original remote that comes in the box is already paired to the adjustable base. No further action is required. In the event that the remote is not paired with the base, follow the steps below.
STEP 1
Unplug the Power Cord from your power outlet. Wait 1 minute, then plug it back
in to your power outlet. Perform Step 2 within 10 seconds, while the control
box light is flashing.
STEP 2
Remove the cover on the back of the remote and hold the PAIR button. The PAIR
button will illuminate and start to flash. When the PAIR button stops
flashing, the pairing LED light on the control box will stop illuminating.
Release the PAIR button on the remote.
STEP 3
Test all remote functions. If the remote buttons do not impact the
adjustable base movements, please repeat the process again or call Ergomotion
customer service: 1-888-550-3746
Connecting strap (optional)
If a split setup is being installed, optional plastic connecting straps can be used to help secure the bases together. To purchase optional accessories, please call 1-888-550-3746.
STEP 1
With the bases in their desired location, slightly loosen both legs to
allow the strap to fit on the leg bolt, between the leg washer and frame.
STEP 2
Slide side (a) of the connecting strap onto leg bolt. Swing the strap and
connect side (b) to the leg bolt. Secure the strap by shifting to the left.
STEP 3
Re-tighten legs. Do not over tighten. Use the remaining strap and repeat on
other end of the base.
Syncing two bases (optional)
A Sync Cord is included with the base. Not available on Queen, Full or Full-
Long size bases.
The Sync Cord connects the two control boxes to a single remote for the
synchronization of two bases.
This process is most commonly used for syncing two connected TXL bases.
STEP 1
Unplug the base(s) from power source.
STEP 2
Connect the Sync Cord to the Multifunction port of each Control Box.
STEP 3
Plug bases back into the power source.
STEP 4
Check to ensure all cords are securely attached. Both remotes will now
operate both bases simultaneously.
The system is now linked. Pressed buttons on either remote will control the two bases simultaneously.
PERFORMANCE NOTES
If bases become mismatched, returning the bases to the flat positions will re-
sync the mechanical positions.
Headboard bracket installation guide (optional)
Headboard Brackets are an optional accessory and are not included.
A hex key is included with the accessory kit to complete installation.
STEP 1
a. Align the hole in the bracket to the brass sleeve into which the leg
threads. Hold the bracket in place and screw the leg into the base until it is
snug. DO NOT OVERTIGHTEN. Too much force may cause the leg to spin freely.
b. Align the tab with the hole in the frame (located towards the foot of the
base) and use a short bolt, washer and wingnut to secure the bracket.
Make sure the bolt is tight.
STEP 2
a. Measure the distance between the mounting holes on the headboard and
install the T-Bracket to accommodate the headboard.
b. To install the T-Bracket, slide the T-Bracket through the end of the
headboard bracket. Align the flat side of the T-Bracket plate to the mounting
holes on the headboard.
c. Secure T-Bracket in place by inserting two short screws through top of
bracket. Use hex key to tighten screws.
STEP 3
Connect your headboard to the attachment plate using the remaining long
screws or hardware that came with your headboard. The heads of the bolts will
face outward. Use hex key to tighten bolts.
Battery backup strap (optional)
For emergency use only, in case of a power outage.
Batteries are not to be used for normal operation of the bed.
STEP 1
Disconnect the Power Supply from the input power cord.
STEP 2
Connect the Battery Backup Strap to the (2) Alkaline 9 Volt batteries. Do
not mix brand name Batteries.
STEP 3
Connect the end of the Battery Backup Strap to the input cord.
STEP 4
Use the remote to return the base to a flat position.
Note: Detach the Battery Backup Strap and reconnect the power supply
after the emergency is over, as the system will continue to draw power from
the batteries even if not in use.
Troubleshooting
If one or more functions on the bed base have stopped operating:
- Check under the bed base to verify that the wired connections are secure and that there are no cords or bedding obstructing the movementhe base .
- Check to ensure the green LED light is illuminated on the power supply. If there is no light, verify that the input and power cords are properly connected.
- Unplug the base for 1 hour to reset the electronic components.
- Plug bed base into a different electrical outlet, or test current outlet with another working appliance (a grounded, electrical surge protect recommended).
- Ensure that your remote batteries are properly installed or do not need replacing.
- Ensure Child Lock feature is not enabled. See page 11 for more information.
- Ensure that the remote control is paired to the bed base. See page 12 for more information.
Nationwide Customer Service
Phone 1 .888 .550 .3746
Email info@ergomotion.com
Web www.ergomotion.com
©2022 Ergomotion Inc
V001_12/2023
For customer support,
visit www.ergomotion.com
or
call: 1-888-550-3746
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>