SHARP EC-A1RAS Cordless Vacuum Cleaner Instruction Manual
- June 16, 2024
- Sharp
Table of Contents
- EC-A1RAS Cordless Vacuum Cleaner
- Product Information
- Specifications
- Safety Precautions
- Charger Safety
- Product Usage Safety
- Preparation
- Vacuuming
- Emptying the Dust Cup
- Maintenance
- Storage
- Q: Can I use the vacuum cleaner on wet surfaces?
- Q: How often should I clean the filter?
- Q: Can I wash the attachments with water?
EC-A1RAS Cordless Vacuum Cleaner
Product Information
Specifications
- Model: EC-A1RAS
- Type: Cordless Vacuum Cleaner
- Intended Use: Household use
- Reg. No.: I.31.STID2.00501.0516
Safety Precautions
Matters that must be observed in order to prevent danger to
humans and damages to property are explained. Descriptions of
conditions that occur due to erroneous uses are classified in the
following manner for the purpose of providing explanations:
-
Danger: with high probability of death or
sustaining serious injury. -
Warning: matters with probability of death or
serious injury. -
Caution: matters with probability of
sustaining minor injury or damage to property.
Charger Safety
-
Do not use any power outlet that is loose.
-
Do not insert or remove the power plug with wet hands. Do not
use any damaged power plug or power cord. (Risk of electrocution,
short circuiting, ignition of fire or cause injury.) -
Always use the charger that is a genuine accessory. Do not use
an extension cord. (Risk of fire disaster, electrocution and
product malfunction.) -
Remove dust on the power plug periodically. Remove the plug and
wipe with a dry cloth. (Dust accumulating on the power plug may
lead to insulation defects due to humidity and the like, which can
cause fire disaster.) -
Securely insert the power plug to the base. (Incomplete
insertion of a plug may cause fire disaster, electrocution or short
circuiting.)
Product Usage Safety
-
Do not use the product near any substance that is flammable or
allow such substance to be suctioned into the product. (Risk of
explosion or fire disaster.) -
Never use the product in a location that is wet or where it can
become wet such as a bathroom, or where there is high temperature
and high humidity and never allow water to be suctioned into the
product. (Risk of electrocution, short circuiting and ignition of
fire.) -
Do not apply water or detergent on the vacuum cleaner body or
the charger and do not wash them with water (excluding components
that can be washed with water). (Risk of electrocution, short
circuiting and ignition of fire.)
Product Usage Instructions
Preparation
-
Ensure that the vacuum cleaner is fully charged before
use. -
Check that all parts and accessories are properly connected and
assembled. -
Inspect the dust cup and filter for any debris or
blockages.
Vacuuming
-
Press the power button to turn on the vacuum cleaner.
-
Start vacuuming by moving the cleaner head over the desired
surface. -
Use the appropriate attachments for different surfaces and
areas. -
Continue vacuuming until the desired area is clean.
Emptying the Dust Cup
-
Turn off the vacuum cleaner and unplug it from the power
source. -
Press the release button or lever to detach the dust cup from
the main unit. -
Hold the dust cup over a trash bin and press the emptying
button or lever to release the collected debris. -
Tap or shake the dust cup to remove any remaining debris.
-
Reattach the dust cup securely to the main unit.
Maintenance
-
Regularly clean the dust cup, filter, and brush roll to ensure
optimal performance. -
Inspect and clean the attachments for any debris or
blockages. -
Replace the filter as recommended by the manufacturer.
-
Store the vacuum cleaner in a clean and dry place.
Storage
-
Ensure the vacuum cleaner is turned off and unplugged before
storing. -
Wrap the power cord around the designated cord hooks or storage
compartments. -
Store the vacuum cleaner in an upright position to save
space.
Specifications
- Weight: [insert weight]
- Battery Type: [insert battery type]
- Battery Life: [insert battery life]
- Dust Cup Capacity: [insert dust cup capacity]
- Power: [insert power rating]
Troubleshooting
If you experience any issues with the vacuum cleaner, refer to
the troubleshooting section in the user manual. If the problem
persists, contact customer support for assistance.
FAQ
Q: Can I use the vacuum cleaner on wet surfaces?
A: No, the vacuum cleaner is not designed for wet use. Using it
on wet surfaces may result in electrocution or product
malfunction.
Q: How often should I clean the filter?
A: The frequency of filter cleaning depends on usage. It is
recommended to clean the filter at least once a month or when you
notice a decrease in suction power.
Q: Can I wash the attachments with water?
A: Some attachments may be washable with water, but it is
important to refer to the user manual for specific instructions.
Avoid washing the vacuum cleaner body or charger with water.
Model
EC-A1RAS
Cordless Vacuum Cleaner
Household use
Operation Manual
Penyedot Debu Nirkabel
Penggunaan Rumah Tangga
Panduan Operasional
Máy hút bi không dây
Dùng cho gia ình
Hng dn s dng
Reg. No. : I.31.STID2.00501.0516
EC-A1RA_Hyo_contens_A4 (ai sorted).indd 1
2017/07/07 14:39:45
CONTENTS
SAFETY PRECAUTIONS PART NAMES PREPARATION VACUUMING EMPTYING THE DUST CUP
MAINTENANCE STORAGE SPECIFICATIONS TROUBLESHOOTING
PagePs ages
EN-1 EN-5 EN-7 EN-9 EN-13 EN-15 EN-19 EN-20 EN-21
DAFTAR ISI
Halaman
TINDAK PENCEGAHAN UNTUK KESELAMATAN NAMA-NAMA SUKU CADANG PERSIAPAN PROSES PENGHISAPAN PENGOSONGAN WADAH PENAMPUNG DEBU PERAWATAN PENYIMPANAN SPESIFIKASI PEMECAHAN MASALAH
ID-1 ID-5 ID-7 ID-9
ID-13 ID-15 ID-19 ID-20 ID-21
EC-A1RA_Hyo_contens_A4 (ai sorted).indd 2
2017/07/07 14:39:45
TH-1
TH-5
TH-7
TH-9
TH-13
TH-15
TH-19
TH-20
TH-21
MC LC
CÁC BIN PHÁP PHÒNG NGA AN TOÀN TÊN CÁC B PHN CHUN B HÚT BI LÀM SCH HP CHA BI
BO TRÌ CT GI C TÍNH K THUT X LÝ S C
Trang
VN-1 VN-5 VN-7 VN-9 VN-13 VN-15 VN-19 VN-20 VN-21
EC-A1RA_Hyo_contens_A4 (ai sorted).indd 3
2017/07/07 14:39:45
SAFETY PRECAUTIONS
Matters that must be observed in order to prevent danger to humans and damages to property are explained.
Descriptions of conditions that occur due to erroneous uses are classified in the following manner for the purpose of providing explanations.
Details that related to “matters
Danger with high probability of death or sustaining serious injury”.
Details that related to
Warning “matters with probability of death or serious injury”.
– Details that relate to “matters with
Caution probability of sustaining minor injury or damage to property”.
Warning – Matters for preventing electrocution, fire disaster, electricity leaks and major injuries
Charger
Do not overload power outlets. (Risk of fire disaster or electrocution.) Do
not damage the power plug or power cord. Do not force the cord or plug to bend
Do not pull the cord or plug Do not twist the cord or plug Do not bundle the
cord Do not pinch the cord or plug Do not modify the cord or plug Do not allow
the cord or the plug to be tangled up in the Rotary brush of the Suction head
Do not scratch or damage the cord or the plug Do not place any heavy object on
top of the cord or the plug (The cord may be damaged and cause fire disaster
or electrocution.)
Do not use any power outlet that is loose.
Do not insert or remove the power plug with wet hands. Do not use any damaged
power plug or power cord. (Risk of electrocution, short circuiting, ignition
of fire or cause injury.)
Always use the charger that is a genuine accessory. Do not use an extension
cord. (Risk of fire disaster, electrocution and product malfunction.)
Remove dust on the power plug periodically. Remove the plug and wipe with a
dry cloth. (Dust accumulating on the power plug may lead to insulation defects
due to humidity and the like, which can cause fire disaster.)
Securely insert the power plug to the base. (Incomplete insertion of a plug
may cause fire disaster, electrocution or short circuiting.)
Location of using product and when product is in use
Do not use the product near any substance that is flammable or allow such substance to be suctioned into the product.
Kerosene, gasoline and incense Benzene thinners
Cigarette stubs
Combustible substances such as toner (Risk of explosion or fire disaster.)
Never use the product in a location that is wet or where it can become wet such as a bathroom, or where there is high temperature and high humidity and never allow water to be suctioned into the product.
(Risk of electrocution, short circuiting and ignition of fire.)
Do not apply water or detergent on the vacuum cleaner body or the charger and do not wash them with water (excluding components that can be washed with water). (Risk of electrocution, short circuiting and ignition of fire.)
Do not throw the product
into a fire or heat it.
Furthermore, do not
place the product
near fire or space
heater, a location exposed to direct sun light or at a
–
location with high
temperature such as inside
a car parked under the
flaming sun and the like. (Risk of short circuiting,
–
ignition of fire, liquid leakage
and explosion.)
Stop using the product immediately when there is any abnormality or malfunction.
The product does not always operate even when the switch is turned on. Moving
the power plug or the power cord of the charger results in the Charging lamp
on the charger turning on and off.
Abnormal sound is emitted while the product is in operation.
Abnormally hot with the vacuum cleaner body or the charger deforming from
heat. Burning smell is emitted.
Press the and remove the battery from the vacuum cleaner body immediately.
Disconnect the power cord of the charger from the electrical outlet.
Refer to EN-21 and 22 in
– “TROUBLESHOOTING” and contact your nearest
service center approved by SHARP.
EN-1
De
EC-A1RA_Eng_A4(ai sorted).indd 1
2017/07/07 11:43:17
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance. If the Cord
of the Charger is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard. The
Suction head and Pipe (accessories) are only to be used with the appliance. Do
not connect these accessories with the power outlet or plug, socket-outlet,
connector or appliance inlet that is connected with the power outlet.
Details on the types of matters that must be observed are explained using
following symbols.
Do not do this
Must do this
Caution – Matters for preventing electrocution, fire disaster and malfunction of vacuum cleaner body
When product is used
Never modify the structure of the vacuum cleaner body or the charger and do
not disassemble and no one must repair the product unless the individual is a
repair technician. (Risk of fire disaster, electrocution or injury.)
Contact your nearest service center approved by SHARP.
Do not touch the terminals of the charger
or the battery while charging or
immediately after completing charging.
(Risk of burns.)
EN-7
Do not touch the terminals of the vacuum cleaner body, the charger or the
battery with a metal object such as a needle or a pin.
(Risk of heating, ignition of fire, electrocution or product malfunction.)
When product is used
Do not block the air exhaust port
Do not operate the product over a
long period of time with the Suction
head blocked.
(Risk of deformation of vacuum
cleaner body, ignition of fire
and fire disaster due to
overheating.)
–
–
Do not allow any metal objects or pins to
enter in the pipe insertion slots, pipe
contacts or air exhaust port.
(Risk of electrocution and
–
malfunction of product.)
Terminal
Terminal
Terminal
Do not touch the Rotary Brush or Roller Switch (with safety stop mechanism). (Risk of injury of a hand or the like.) Be particularly careful with children!
Roller Switch
Rotary brush
Must do the followings when servicing or inspecting the product
Press the and remove the battery from the vacuum cleaner body.
Disconnect the power cord of the charger from the electrical outlet. (Risk of
electrocution or injury.)
Pipe contact
–
Do not transport the product by holding on a pipe or the Dust Cup.
(Risk of injury or malfunction of product when the vacuum cleaner body becomes
dislodged or falls.)
Charger
Remove the plug
Be sure to remove the power plug from the power outlet by holding onto the
power plug with a hand. (Risk of electrocution, short circuiting and ignition
of fire.)
Disconnect the power cord of the product from the electrical outlet when not
using the product over a long period of time.
(Risk of electrocution, electric current leakage and fire disaster due to
deterioration of insulation.)
EN-2
EC-A1RA_Eng_A4(ai sorted).indd 2
2017/07/07 11:43:17
SAFETY PRECAUTIONS
Information on Battery
Danger Preventing accidents and major injuries from electrocution or fire disaster and the like.
Do not use the battery with any appliances other than the vacuum cleaners
manufactured by Sharp and do not disassemble, modify or separately charge the
battery.
(Risk of fire disaster, electrocution or injury.) Do not allow any metal
object, such as a needle or a pin to contact a terminal and do not transport
or store the product with such articles as necklaces or hair pins. Do not
pierce the product with a nail, hit with a hammer, step on the product or
otherwise give strong impact or throw the product. Do not use any battery that
has been deformed or scratched from dropping and the like. Do not throw the
product into fire or heat it. Do not place the product near fire or space
heater, a location exposed to direct sun light or at a location with high
temperature such as inside a car parked under the flaming sun and the like. Do
not immerse or wet the product with water. Do not use any charger for a
battery that is not specified by Sharp. (Risk of heating, smoke generation,
bursting, ignition of fire or liquid leakage.)
Always use a battery that is specified by Sharp.
(Risk of heating, smoke generation, bursting or ignition of fire.)
When the liquid from inside the battery leaks and comes in contact with the
eye, do not rub and immediately rinse out the liquid from the eye using clean
water such as tap water and receive treatment by a physician right away. (Risk
of harm to the eyes.)
EN-3
Warning Matters for preventing electrocution, fire disaster, electricity leaks
and major injuries
Do not use the battery when there is emission of smell, heat, liquid leakage,
discoloration, deformation and any other abnormality that was not present
previously. (Risk of heating, smoke generation, bursting or ignition of fire.)
Do not touch the battery with a wet hand. (Risk of heating, ignition of fire
or electrocution.)
When the liquid from inside the battery leaks and comes in contact with the
skin or clothing, immediately rinse out the liquid from the skin using clean
water such as tap water. (Risk of harm to the skin.) Keep the battery at a
place that is out of reach of infants. Stop charging if the battery is not
completely charged even after exceeding the
prescribed charging time and replace the battery. EN-4
Caution Matters for preventing electrocution, fire disaster and malfunction of
base unit
A battery must be charged in an environment with the temperature in the range
of 5°C to 35°C. (Risk of heating, generation of smoke, bursting and ignition
of fire, as well as improper charging or deterioration of the battery.) Use
and store the product in a location where it is not exposed to humidity or
dust. (Risk of heating, ignition of fire or electrocution.)
EC-A1RA_Eng_A4(ai sorted).indd 3
2017/07/07 11:43:17
Tips
Precautions for Details
When the product is not used for a long time.
There may be cases where the floor surface is damaged when the roller switch on the bottom side of the Suction head, wheels or the Napped cushion is worn.
In the event the part becomes worn it is necessary to replace it with a new one. Stop using the product and contact your nearest service center approved by SHARP.
Wheel
Roller Switch
The replacement of the part for the is performed while the product
is left with Sharp. Replacement part (Rotary brush cover) is available for
purchase.
Napped cushion Integrated with Suction head
Napped cushion
Integrated with Rotary brush cover
Remove the battery from the base unit and completely charge the
battery before storing. EN-7
It is recommended that the power plug of the charger be removed from the power
outlet. The charger consumes about 0.5 W of power while the power plug is
connected to the power outlet. Removing the power plug when the charger is not
in use can keep down wasteful power consumption.
Consider following precautions when storing the battery.
Do not suction any of the following types of items (Risk of scratching of the product interiors and clogging of the product, as well as product malfunction).
Liquid or moist dirt.
Twines
A large amount of sand.
Sharp objects (glass, razor blade and the like).
Do not transport or store the product together with any metal object, such as
a needle, necklace or hair pin.
Furthermore, store the product in a location where there is little humidity or
dust.
Large dirt or a large amount of dirt suctioned at the same time. Clean respective filters when fine powder (plaster, cement,
(Risk of heating, ignition of fire or electrocution.)
chalk and the like) has been suctioned. EN-15 and 16
Do not operate the product while the Dust cup assembly EN-5
has been removed.
This product is for indoor use only.
Do not hit the Suction head hard on the steps on the floor surface or gaps in
floor heights, as well as furniture or wall (Risk of the floor surface
becoming scratched). Do not apply lubricant to the Rotary brush (Risk of
plastic parts cracking). Do not drag the charger (Risk of scratching on the
floor surface).
There are instances where the operation of the product causes noise to appear
on the screen of television sets. There is no negative impact on the
television set when this occurs.
This cordless vacuum cleaner is intended for household use and must not be
used for commercial applications. Furthermore, the product must not be used
for any purpose other than cleaning.
Replacing Battery
Batteries are consumable products.The operating time gradually becomes shorter
as the battery deteriorates with repeated use. Although the deterioration of
batteries vary depending on the condition of use or operating environments,
the battery should be replaced if any of the following conditions apply.
When the operating time is extremely short even when the battery has been
charged. When the Charging lamp (red) of the charger blinks slowly whenever
charging in an environment with room temperature of between 5°C and 35°C.
Rtheecboamttmereyn. dedENtim-6e for replacing
There is no malfunction if the the Charging lamp (red) on
the charger blinks slowly when charging in an
environment with a low temperature (about 5°C or lower)
or a high temperature(about 35°C or higher).
Charge the battery in an environment that is between 5°C to 35°C.
We invite you to recycle the spent battery.
The battery (lithium-ion battery) is a precious resource that can be recycled.
Bring in the spent battery to a store that accepts batteries for recycling, rather than disposing of
them as waste material.
Information on handling of spent
Insulate the terminal sections using plastic tape or
tbhealitkt)eetrhyat.are
available
on
the
market.
Furthermore, do not disassemble the product. )
Terminal
EN-4
EC-A1RA_Eng_A4(ai sorted).indd 4
2017/07/07 11:43:17
PART NAMES
Names of each part and how to assemble
When using the product in the Stick state
Press Release button to remove respective parts.
Right side surface
Battery EN-4, 7
Battery release button EN-7
Exhaust port The built in filter cannot be removed. Cleaning is not required.
Dust cup assembly
Dust disposal hook (yellow)
Cover section Pleat filter
Filter Cover Mesh filter
Dust Cup Dirt accumulates here.
Press the Dust disposal hook (yellow) to split the Dust Cup from the Cover
section.
Wash respective filter with water when the Filter care
lamp (red) blinks rapidly EN-15, 16
Handle / Control switch
Always hold on the handle on the vacuum cleaner body to transport the
product.Holding onto other parts (such as a pipe of the Dust Cup) can dislodge
such parts from the vacuum cleaner body and the product may fall and lead to
injury or product
malfunction. EN-9 Lamps EN-6
Back side
Holder section
EN-10, 19
Cup release lever (black)
EN-13
Release button
Pipe
Release button
Suction head EN-17
Accessories The Suction head and Pipe described above are also accessories.
Charger (1 unit)
EN-7
Cord (Approx. 80 cm)
Battery (1 piece)
(Already attached to Charger at shipping)
Cleaning Brush (1 piece)
(Attached to vacuum cleaner body) Attach the brush in the direction shown in
the diagram after use.
Enclosed Nozzles
Duster Nozzle (1 piece)
EN-11, 12
Crevice Nozzle (1 piece)
EN-5
Plug Adapter (1 piece)
2-flat-pin adapter
Use the adapter if your outlet is for 2-flat-pin plug. This adapter is not
used in Singapore.
EC-A1RA_Eng_A4(ai sorted).indd 5
2017/07/21 10:00:55
When using the product in the Handy state
Press Release button to remove respective parts.
Click!
Release button
Tips for making the battery last
Charge the battery every time the product is used, regardless of how long it
was used.
The battery lasts longer when charged before the charge level becomes low.
Leaving a discharged battery without charging will lead to the deterioration
of the battery.
When the product is not used for a long time EN-4
Recommended Time for replacing the battery
About 1,100 times of charge/discharge
According to tests conducted based on Sharp’s standard for repeatedly charging
and charge/discharge a battery. The life of a battery can vary depending on
the conditions of use and the environment.
Lamps notify status of the vacuum cleaner body
Filter care lamp (red)
Battery level indicator lamp (green) *1
Lamp State
Filter care lamp (red)
Turned on *2
Fast blinking
Indicated State/ Explanation Empty the dust cup and clean the filter. EN-13,
14 The filter of the Dust cup assembly is dirty.
Clean the filter by rinsing with water. The filter of the Dust cup assembly is
clogged with dust. EN-15, 16
The vacuum cleaner body is overheating. Leave the product in a cool place for
a while. Operating the product without allowing it to cool leads to the
overheating protection circuit of the vacuum cleaner body triggering, which
disables the product for some time.
Battery level indicator lamp (green)
Turned on
Blinking
Fast blinking
There is sufficient charge remaining in the battery.
The charge remaining in the battery is low. The charge remaining in the
battery is quite low. (There is no charge remaining in the battery.)
Charge the battery. EN-7
1 The Battery level indicator lamp is turned on in following situations. (The lamp is not turned on when there is no charge left in the battery.) About 5 seconds after the battery is reinstalled on the vacuum cleaner body.
While using the product for cleaning
About 5 seconds after pressing the and stopping the operation of the product.
2 The lamp may also turn on when the Suction head is clogged even when the filter is not dirty. In such instances, press the and then restart operation to turn the lamp off.
EN-6
EC-A1RA_Eng_A4(ai sorted).indd 6
2017/07/21 10:00:55
PREPARATION
See EN-6 for
tips for making the
battery last.
Charging battery
The battery is not charged when the product is purchased, so the battery must
be removed from
the vacuum cleaner body and charged until the Charging lamp on the charger is
turned off.
Remove the battery from the vacuum cleaner body.
Press the Battery release
Battery release button
button in the direction of
the arrow
1
Remove the battery by sliding it in the direction
of the arrow.
Insert the power plug of
the charger in the power
2
outlet.
In case your outlet is for 2-flat-pin Charger
plug, use the enclosed adapter.
(Make sure the plug is fully
inserted into the plug adapter.)
Set the battery on the charger and recharge.
Power plug
Insert securely to as far as it goes.
Verify that the Charging lamp (red) is turned on.
If the lamp blinks (repeating the “blinking” in
intervals of about one second) the battery has
Align the terminals.
not been securely inserted. Insert the battery securely to as far as it goes.
3
Lamp state
Charging status
Estimated duration from start of charging*
The estimated duration of time required for charging varies depending on the
Turned on
Charging
–
remaining charge in the
Turned off
Charging completed (fully charged)
About 80 minutes
battery at the time charging starts.
Notices
The charger or the battery becomes hot while charging, but this is not abnormal.
CAUTION
Do not touch the terminals of the charger or the battery since they become hot while charging or immediately after completing charging. [Risk of burns.]
EN-7
EC-A1RA_Eng_A4(ai sorted).indd 7
2017/07/07 11:43:18
Insert the battery into the vacuum cleaner body.
Remove the battery from the charger.
Insert the battery into the vacuum cleaner body.
4
Click!
Securely insert the battery along the grooves on the vacuum cleaner body until
the “click” sound is emitted.
Once the terminals are connected, the Battery Level Indicator lamp on the
vacuum cleaner body turns on for about five seconds to notify the remaining
charge in the battery. Be sure to securely insert the battery until the
“click” sound is heard, even if the lamp starts to light up during the
process.
Slot
Align the terminals.
Notices
In cases where charging is not possible, verify followings.
Is the power plug of the charger dislodged? Is the battery correctly set to the charger?
Is there any dirt or foreign matter attached to a terminal of the charger or
the battery? Remove the dirt or foreign
matter with dry cloth. EN-17, 18
Information on Charging
The charging time may be long in following cases. When not in use for long
period of time The battery is charged in an environment at a low temperature
(approx. 5°C or lower) or a high temperature (approx. 35°C or higher) (charge
the battery in an environment with at room temperature between 5°C and 35°C).
Information on operating time
The operating time gradually becomes shorter as the battery is used repeatedly.
When the remaining charge in the battery becomes low, the
Battery level indicator lamp (green) blinks to notify the
status.
EN-6
The Charging lamp (red) of the charger blinks slowly)
Continuous operation time*
High mode
About 8 minutes
Standard mode
About 30 minutes
When a single battery is used (fully charged and initial condition of the battery / 20°C). Conditions may vary depending on the material of the floor surface, environment in which the product is used and the condition under which the product is used.
If the blinking occurs when the room temperature is between 5°C and 35°C, then
it is time to replace the battery. EN-4
There is no malfunction if the product blinks in an environment with a low
temperature (about 5°C or lower) or a high temperature (about 35°C or higher).
Charge the battery in an environment that is between 5°C to 35°C.
When the Charging lamp (red) of the charger rapidly blinks, that may be caused by malfunction of the charger, or deterioration or malfunction of the battery. Contact your nearest service center approved by SHARP.
EC-A1RA_Eng_A4(ai sorted).indd 8
EN-8
2017/07/07 11:43:19
VACUUMING
Flow of cleaning process
Control switch
Start
The mode toggles between the “High mode” and the “Standard mode” each time it
is pressed. High mode: When cleaning with maximum suction power.
Standard mode: When cleaning with subdued suction power. (When a mat or a rug
tends to block the Suction head, for instance.)
Finish
Cleaning completed
Charging the battery
EN-7
Disposing of dirt is recommended after each cleaning session, for the
purpose of hygiene. EN-13, 14
Notices
The Rotary brush of the Suction head automatically turns when the cleaning
starts.
Even when a cleaning session is completed in the Standard mode, the operation
starts with the High mode if the is pressed the next time.
When the remaining charge in the battery becomes depleted while operating, the
operation is automatically stopped to prevent excessive discharge that can
deteriorate battery. Always charge the battery each time the product is used
for cleaning, regardless of how long it was used.
Safety Stop
The Rotary brush stops automatically for safety purpose when the Suction head
(roller switch on the
bottom side EN-17 ) is off the floor while cleaning.
The operation does not stop in such instances. The rotation restarts when the
Suction head contacts the floor and moved.
Even when the Suction head contacts the floor if the Roller Switch is off the floor the operation is temporarily suspended.
CAUTION
Do not touch the Rotary Brush or Roller Switch while the operation is temporarily suspended. [Risk of injury when the Rotary brush starts to operate] Be sure to press the to stop the operation when cleaning the Suction head.
EN-9
EC-A1RA_Eng_A4(ai sorted).indd 9
2017/07/07 11:43:19
Tips for Vacuuming
Move the Suction head so that it moves
lightly and glides slowly. More dirt is suctioned this way
than
quickly
moving the Suction head back and forth.
This also prevents scratching of the vacuum
cleaner and the floor surface.
Stick state
For cleaning floors.
Handy state
For cleaning stairs.
CAUTION
Always install the Suction head or an Accessory Suction head when cleaning.
[Risk of scratching of floor surface or product malfunction] Do not clean
while pressing the Suction head hard against the floor surface.
The wheels and Napped cushions EN-17 may wear quickly and scratch the floor
surface.
Moving the Suction head (wheel) sideways or diagonally can result in scratches
and markings on the floor surface.
There are instances where the rotation of the wheels deteriorate due to the
entanglement of pet hair and
the like on the wheels. Be sure to clean the wheels often. EN-17
The product can be left in the conditions depicted in the diagrams below when pausing the cleaning operation.
Resting the vacuum cleaner
Standing state
Hook the holder section onto a table or the like.
Hook the holder section on a chair or the like.
Holder section
Always press the and stop the operation of the product.
Place the product on a flat floor.
CAUTION
Keep the Suction head contacting the floor surface when pausing the cleaning
operation. [Risk of falling or tumbling of the product] Verify that there is
nothing in the vicinity of the product that can be damaged easily when
standing the vacuum cleaner body leaned on an object. Pay particular attention
to ensure no infant or pet is allowed to get near the product.
Do not leave the product while leaning on an object.
EC-A1RA_Eng_A4(ai sorted).indd 10
EN-10
2017/07/07 11:43:19
VACUUMING
Using accessory nozzles (Duster nozzle and Crevice nozzle)
Duster nozzle
The accessory may be used by attaching on the vacuum cleaner body or on a
pipe. For cleaning high places, such as above furniture.
Do not press the while operating when cleaning with the vacuum cleaner body
facing up. Press the after facing the Suction head downward to stop the
operation. Pressing the while the product is facing up may lead to the dirt
spilling out of the vacuum cleaner body.
Use
Insert securely and use.
Click!
Attach
Release button
Removal
Turn while pressing the Lock Release to change the angle.
Lock Release
Click!
Attach
Release button
Removal
Press the Release button for the vacuum cleaner body or the pipe to remove the accessory.
CAUTION
Careful not to pinch a hand or a finger in the rotating section when changing the angle!
Rotating section
Tip
EN-11
EC-A1RA_Eng_A4(ai sorted).indd 11
2017/07/07 11:43:20
Do not use the product to clean items that scratch easily, such as a piano.
Using Accessory Suction Inlet (Duster nozzle and Crevice nozzle)
Crevice nozzle
The accessory may be used by attaching on the vacuum cleaner body or on a
pipe. For cleaning gaps between furniture and sash on the windows.
This is a hole intended to prevent overheating of the motor in an enclosure. Do not block the hole.
Use Insert securely and use.
Click!
Attach
Release button
Removal
Press the Release button for the vacuum cleaner body or the pipe to remove the accessory.
Click!
Attach
Release button
Removal
CAUTION Careful not to pinch a hand or a finger!
EC-A1RA_Eng_A4(ai sorted).indd 12
EN-12
2017/07/07 11:43:20
EMPTYING THE DUST CUP
Guide for disposing of dirt
When the level of the accumulated dirt reaches the “MAX” line.
Mesh filter
“MAX” line
MAX
MAX
Dispose of the dirt before the level of the accumulated dirt exceeds the
height of the line, even when the dirt is leaning on one side or the other.
Disposing of dirt is recommended after each cleaning session, for the purpose
of hygiene.
When the Filter care lamp (red) is turned on*
Removal
Removing the Dust cup assembly
Pull the Cup release lever while standing the vacuum cleaner body vertically.
Cup release lever
Removal
Cleaning is not required for the built in filter. Do not remove the filter.
(Red: Turned on)
Dispose of the dirt in the Dust Cup and follow the procedure described on the
right to remove the dirt on the Mesh filter. If the lamp still does not turn
off, clean the unit.
EN-15, 16
The lamp may also turn on when the Suction head is
blocked (when cleaning a mat or when using an
enclosed nozzle and the like) even when the filter is
not dirty. In such instances, press the
and then
restart operation to turn the lamp off.
Tips
Continuing to operate the product without disposing of the accumulating dirt
results in the deterioration of the suction power due to the attachment of the
dirt on the Mesh filters. Be sure to dispose of the dirt. Continuing to
operate the product without disposing of the dirt may lead to the product
malfunction. Dispose of the dirt on newspapers or over a dirt bin. [Dust could
spill out]
EN-13
Removing the Cleaning Brush
It is on the vacuum cleaner body side after the Dust cup assembly has been
removed.
Pull out from the position depicted in the diagram.
EC-A1RA_Eng_A4(ai sorted).indd 13
2017/07/07 11:43:20
Emptying the Dust Cup
1 Remove the Dust Cup and dispose of the dirt.
Press the Dust disposal hook (yellow) on the side of
the Cover section. Lift the Cover
Cover section
section.
Dust disposal hook (yellow)
Mounting the Dust Cup Assembly
Install the Dust cup assembly on the vacuum cleaner body.
Put the recessed section on the Dust Cup to the hook (blue) on the vacuum
cleaner body
Ensure that no dirt remains at the bottom of the Dust Cup.
2 Remove dirt on the Mesh filters with a cleaning brush.
When the dirt is entangled and does not come off
Clean the Dust cup assembly.
EN-15, 16
Mesh filter
When used continuously for long time
Dust accumulates on the built in Pleat Filter. Clean this dust out.
EN-15, 16
3 Mount the Dust Cup. Align the protrusion on the Dust Cup and the Dust disposal hook (yellow) and insert.
Dust disposal hook (yellow)
Click!
Protrusion
Recessed section
Hook (blue) Securely push in the direction of the arrow
Click!
CAUTION
The Pleat filter cannot be installed on the vacuum cleaner body unless it is
installed on the Dust Cup.
The suction power may decline, abnormal noise may be heard, dirt may enter
into the motor and other issues may arise that may lead to product malfunction
unless the Dust cup assembly is securely installed on the vacuum cleaner body.
The Dust cup assembly cannot be installed properly on the vacuum cleaner body
unless it is completely assembled.
Caution is required to ensure that the Mesh filters (Upper and Lower) are not
lost while throwing out dirt or cleaning.
EN-14
EC-A1RA_Eng_A4(ai sorted).indd 14
2017/07/07 11:43:20
MAINTENANCE Dust cup assembly
Guide for cleaning
Dispose of dirt and remove the dirt and dust on the filter in following cases.
When the Filter care lamp (red) is turned on*
(Red: Turned on)
The product stops during operations When the suction force is weak The
operating sound changes or becomes louder
Clean the filter by rinsing with water in following cases.
When the Filter care lamp (red) is rapidly blinking*
(Red: Rapidly blinking)
When the vacuum cleaner body is heated. When fine powder has been suctioned
When the Filter care lamp (red) turns on frequently.
If the Filter care lamp (red) rapidly blinks even after the filter has been
sufficiently cleaned, purchase a Pleat filter and replace the filter.
The lamp may also turn on when the Suction head is
blocked (when cleaning a mat or when using an
enclosed nozzle and the like) even when the filter is
not dirty. In such instances, press the
and then
restart operation to turn the lamp off.
Tips
Continuing the use without cleaning will lead to automatic stop of the
operation. Cleaning of the filters must be performed. Lay down newspapers and
the like when cleaning the filters. Do not use any paint thinner, benzene
product or hot water (exceeding approx. 40°C).
EN-15
Removal
1 Remove the Dust Cup. Press the Dust disposal hook (yellow).
Cover section
Lift the Cover
section.
Dust disposal
hook (yellow)
Dust Cup
2 Remove the Pleat filter
Hold on the handle to lift.
Pleat filter
3 Turn and remove the Mesh filters (Upper and Lower). Filter Cover
Mesh filter (Upper)
Mesh filter (Lower)
Filter Cover
Mesh filter (Upper)
The Mesh filters (Upper and Lower) may have different sequence for removal,
depending on how they are matched.
Use the hand grip on the cleaning brush to tap on the raised section (plastic)
of the Pleat filter to dislodge dirt and dust with vibration for easier
cleaning.
Raised section
Care must be taken when inserting a cleaning brush, since inserting a cleaning
brush too far may lead to damage.
EC-A1RA_Eng_A4(ai sorted).indd 15
2017/07/07 11:43:20
Parts that may be washed with water
EN-17
EN-17
EN-17
Cleaning the Filters
Pleat Filter
Dislodge and remove dirt and dust by dusting.
Dust in the direction illustrated in the diagram on the right as dirt tends to
accumulate on the back side.
Top side
Do not use a cleaning brush [Risk of damages].
Mesh filters (Upper and Lower), Filter Cover
Remove dirt and dust with a cleaning brush.
Gently rub the mesh.
When heavily dirtied, wash with water.
Pleat filter
Carefully wash the back side.
When the odor stands out, dilute bleach for clothing in water and immerse the filter in this solution following instruction for the bleach, then rinse with water.
Wash with water or thinned neutral detergent.
Filter Cover
Mesh filter
Dust Cup
Dry the parts after washing with water.
Thoroughly dry prior to assembling. [Risk of filter clogging not improving even after cleaning.] Properly remove moisture, gently wipe off moisture with a towel or the like, dry in shade at a well ventilated location to thoroughly dry.[Risk of emission of odor or product malfunction.]
Estimated drying time:
12 hours. (This may vary depending on the environment and season.)
Do not apply any hot air, such as air blown by a hair dryer. [Risk of deformation or product malfunction.]
Warning
Always do followings during maintenance
Press the to stop the operation of the product and remove the battery.
Disconnect the power cord of the charger from the electrical outlet.
[Risk of electrocution or injury.]
Assembling the Filters
1 Install the Filter Cover and the Mesh filters (Upper and Lower).
Align the positions..
Turn
Align the positions..
Turn
2 Align the salient part of the Pleat filter to the recessed section of the Filter Cover and press in.
Salient section
Recessed section
Install the Dust Cup.
3 Install the Dust Cup. Align the protrusion on the Dust Cup and the Dust disposal hook (yellow) and insert.
Dust disposal
hook (yellow)
Click!
Protrusion
CAUTION
Each part must be assembled correctly in order for them to fit onto the vacuum cleaner body. Caution is required to ensure that the Mesh filters (Upper and Lower) are not lost while throwing out dirt or cleaning.
EN-16
EC-A1RA_Eng_A4(ai sorted).indd 16
2017/07/07 11:43:21
MAINTENANCE Suction head, vacuum cleaner body, Enclosed nozzles and contacts (terminals) of charging section
Suction head (Rotary brush) When lint, rubber band, hair or pet hair and the like is attached.
Removing the dirt
Wheel Rotary brush cover
Roller Switch
Napped cushion
Rotary brush
Remove the dust attached to the Suction head with a Duster Nozzle and cut off
the hair and lint entangled in the section and then wipe with wrung cloth.
Remove dirt that became attached to fine parts with a pair of scissor or a
pair of tweezers with thin tips.
Wash with water When heavily dirtied
After removing the Rotary brush and washing it with water, remove water and
moisture properly and sufficiently dry in a ventilated location before re-
installing.
The Suction head cannot be washed with water in its entirety.
Removal
Remove the Rotary brush cover by sliding the Release lever to the “OPEN”
position.
Rotary brush cover
Release lever
Cut along the slot of the Rotary brush for removal. (Do not cut the tips of
the bristles of the brush.)
Stop using the product when the section
becomes worn, check EN-4 and contact
your nearest service center approved by SHARP.
Remove the belt from the gear while lifting up the Rotary brush and remove the
Rotary brush.
Belt
Remove the belt
Gear
Vacuum cleaner body, Enclosed nozzles and contacts (terminals) of charging section
Vacuum cleaner body
Wipe with cloth moistened with some water or thinned neutral detergent. Do not use any paint thinner or benzene product. [Risk of deterioration or discoloration]
CAUTION
The vacuum cleaner body, charger and battery cannot be washed with water.
When heavily dirtied
Enclosed nozzles
Wash with water or thinned neutral detergent.
Dry the parts after washing
with water.
EN-16
EN-17
EC-A1RA_Eng_A4(ai sorted).indd 17
2017/07/07 11:43:21
Warning
Always do the following during maintenance:
Press the to stop the operation of the product and remove the battery.
Disconnect the power cord of the Charger from the electrical outlet.
[Risk of electrocution or injury.]
CAUTION
Do not use any detergent, paint thinner, benzene product or hot water (exceeding approx. 40°C). [Risk of deterioration or deformation] Do not apply any hot air, such as air blown by a hair dryer. [Risk of deformation or product malfunction]
Attach
Insert the side without a gear of the Rotary brush, as far as it goes into the
slot.
Clip on the tab on the Rotary brush cover in the
slot.
Tab
Rotary brush cover
Slot
Slot
Strap the belt on the gear of the Rotary brush and insert it into the slot.
Installation is not possible when the left and right are reversed.
Slide the Release lever in the direction of the arrow.
Strap on a belt
Gear
Contacts (terminals) of charging section
Wipe off any dirt with a dry cloth.
Terminal
EC-A1RA_Eng_A4(ai sorted).indd 18
EN-18
2017/07/07 11:43:21
STORAGE
Storing Product
CAUTION
Verify that there is nothing in the vicinity of the product that can be damaged easily. Pay particular attention to ensure no infant or pet is allowed to get near the product. If the product cannot be easily secured by hooking due to slippery floor or furniture, do not force the product to hook at a location but disassemble the product for storage instead. Care must be taken as the holder section may slide and leave pigment on the contacted surface, depending on the type of the wall or furniture. Care is needed when leaving the product standing leaning against a wall, as the product may fall.
Store the product by hooking the holder section on furniture or the like, in a
gap between a furniture and the wall, in the corner of the room or inside a
closet where the product is unlikely to fall.
Back side
Holder section
Store the product in the condition described in the diagram below when not using the product for a long period of time.
EN-19
EC-A1RA_Eng_A4(ai sorted).indd 19
2017/07/07 11:43:22
SPECIFICATIONS
Power supply Power supply method Electric power consumption Continuous
operation time* Dust collecting capacity
Charging time
Weight
Base unit dimensions charger dimensions Cord length
Input 100 – 240 V 50-60 Hz (charger) Rechargeable type (lithium ion battery,
18V )
While charging: Approx. 40 W; After charging: Approx. 0.5 W
High mode: Approx. 8 minutes Standard mode: Approx. 30 minutes
0.13 L Approx. 80 minutes (charging may take up to maximum of about 2 hours
depending on the conditions of use, such as the surrounding temperature or
duration of use) 1.5 kg (Suction head, pipe, base unit and battery included)
0.6 kg (charger) 222 mm W x 220 mm D x 980 mm H 200 mm W x 90 mm D x 133 mm H
80 cm (charger)
When a single battery is used (fully charged and initial condition of the battery / 20°C). Conditions may vary depending on the material of the floor surface, environment in which the product is used and the condition under which the product is used.
INSTRUCTION MANUAL FOR BATTERY PACK ( BY-5SB )
” Disposal method and Storage method ”
Dispose of used batteries according to local ordinances and/or regulations.
After extended periods of storage, it may be necessary to charge and discharge
the cells or batteries several times to obtain maximum performance. Do not
store cells or batteries haphazardly in a box or drawer where they may short-
circuit each other or be short-circuited by other metal objects. Keep cells
and batteries clean and dry. Replace only with same SHARP Corporation type BY-
5SB battery pack.
” Charging Information ”
Item Charging Current (Std.)
Charging Voltage (Std.) Charging cut current
Nominal Specifications Specifications 1.95A 3.90A 20.75V 20.25V 100mA
Remark 010 1060 045 4560 060
Charge Limits
Battery Pack Model Maximum Charge Current, A Maximum Charge Voltage, V
BY-5SB
3.9A(010) 7.8A(1060)
20.87V
EC-A1RA_Eng_A4(ai sorted).indd 20
EN-20
2017/07/07 11:43:22
TROUBLESHOOTING
Problems with vacuum cleaner body during operation
Symptoms
The product does not operate (Movements are strange)
Check here
Is the charge remaining in the battery low? Charge the battery. Is the battery
correctly set to the vacuum cleaner body? Remove the battery from the vacuum
cleaner body, wait for about one minutes to pass and then reinstall the
battery on the vacuum cleaner body and restart the operation.(The vacuum
cleaner body circuit becomes reset and the product is restored to normal
operation.)
Reference Pages
EN-7 EN-8
–
was pressed but the operation does not stop immediately.
Operation time is shorter.
Abnormal sound is emitted.
Filter care lamp (red) turns on.
EN-6
The motor keeps on turning for a while even after the is pressed,
–
but this is not a malfunction.
The operating time gradually becomes shorter as the battery is used repeatedly.Replace the battery when the operating time is extremely short even when the battery has been charged.
EN-4
Is the Dust cup assembly correctly installed on the vacuum cleaner body? EN-14
Is there any dirt or foreign matter trapped between the Pleat filter and the Mesh filters?
EN-16
Isthe filter of the Dust cup assembly is dirty? Remove the Dust cup assembly, dispose of dirt and remove the dirt and dust on the filter.
EN-13, 14 EN-15, 16
Is the Suction head blocked? (When cleaning a mat or a enclosed nozzle is used)
EN-6
Press the and then restarting operation turns the lamp off.
The suction power becomes weak during operation in the “High mode”.
Continuously performing power operation at a location exposed to direct sun light or in an environment with high temperature such as inside a car parked under the flaming sun and the like can automatically reduce the suction power as the overheating protection circuit is triggered to prevent deterioration of the battery. Is there any clogging on the Mesh filters or Pleat filter? Clean the filter by rinsing with water.
EN-1 EN-15, 16
The product stops during operations. Filter care lamp (red)
blinks rapidly. EN-6
The suction power is weak.
The operating sound changed or became louder.
Is the vacuum cleaner body overheating? Leave the product in a cool place for
a while. Is the charge remaining in the battery low? Charge the battery. Is
there any clogging on the Mesh filters or Pleat filter? Clean the filter by
rinsing with water.
Is there much dirt accumulating in the Dust Cup?
Is there any large dirt such as a piece of tissue paper entangled inside the
Dust Cup? Is there any dirt clogging the pipe or the Suction head? Remove the
clogging dirt.
Contact your nearest service center approved by SHARP if the product still stops during cleaning even if the measures described above have been implemented.
EN-6
EN-7 EN-15, 16
EN-13, 14 EN-13, 14
–
The battery cannot be charged. (The Charging lamp (red) of the charger is not turned on)
Is the power plug of the charger securely inserted in the power outlet?
Is the battery correctly set to the charger? Is there any dirt or foreign
matter attached to a terminal of the charger or the battery? Remove the dirt
or foreign matter with dry cloth.
–
EN-7 EN-17, 18
The battery cannot be charged. (The Charging lamp (red) of the charger blinks rapidly)
The symptom may be caused by malfunction of the charger,deterioration or malfunction of the battery. Contact your nearest service center approved by SHARP. (Leaving a battery without charging and depleted for a prolonged period of time can deteriorate the battery, which may need to be replaced.)
EN-6
Charging
The Charging lamp (red) of the charger blinks slowly)
EN-21
If the slow blinking occurs when the room temperature is between 5°C and 35°C,
then it is time to replace the battery. Replace the battery.
There is no malfunction if the product blinks slowly in an environment with a
low temperature (about 5°C or lower) or a high temperature (about 35°C or
higher). Charge the battery in an environment that is between 5°C to 35°C.
EN-4
–
De
EC-A1RA_Eng_A4(ai sorted).indd 21
2017/07/07 11:43:22
Check details described below (prior to requesting for repairs or contacting for inquiries).
Symptoms
Check here
Details on thTehetytepmespeorfatmuraettoefrtshethvaatcmuuumstclbeeanoebrsbeordvyecdanarreise to about 40°C during operation, but this is
not abnormal. The vacuum cleaner body is hot
Is there any clogging on the Mesh filters or Pleat filter?
Hot
The charger or the battery becomes hot while charging.
Heat is generated due to the electrical current that is supplied to the control circuit, but this is not abnormal.
Reference Pages
EN-15, 16
–
The Dust cup assembly cannot be installed on the vacuum cleaner body
Are respective components of the Dust cup assembly assembled properly?
EN-16
Dust cup assembly
The Dust cup assembly cannot be assembled.
Is there any dirt accumulating at the bottom of the Dust Cup? Is there any dirt entangled on the Mesh filters? Is the Pleat filter properly installed to the Filter Cover? Are respective components of the Dust cup assembly assembled properly?
EN-14 EN-16 EN-16
EN-16
Suction head & Rotary brush
The Rotary brush does not rotate.
A rattling sound is coming out of the Suction head.
The Rotary brush stops automatically for safety purpose when the Suction head
is off the floor. (Safety Stop) Is the pipe dislodged from the vacuum cleaner
body?
Is any hair or lint tangled on the brush? The Rotary brush may stop in some
instances as the automatic stop function is triggered when the Suction head
becomes stuck on a surface when the product is used to clean carpets and mats
on which the Suction head can become closely attached and blocked. In such
instances, turn off the product. The automatic stop function will be released
and the product can then be used again. Is the Suction head assembled
properly?
This is a sound emitted by the Roller Switch, due to the structure (safety
stop mechanism). This is not abnormal.
EN-9
–
EN-17
–
EN-17
–
The air discharged from the vacuum cleaner body smells.
Is there much dirt accumulating in the Dust Cup? (Depending on the type of
accumulated dirt some odor may be emitted.)
Has the Mesh filters or the Pleat filter been washed with water and then
sufficiently dried? [Using the product while moisture remains on or in the
product may lead to the emission of an odor]
EN-13, 14 EN-15, 16
A part of the Pleat filter appears to be white and floating.
– The white filter material can become visible at times, but there is no
quality
issue with such a situation.
Others Odor
If the Filter care lamp (red) and the Battery level indicator lamp (green) on the vacuum cleaner body are blinking simultaneously the product may be malfunctioning. Contact your nearest service center approved by SHARP.
EC-A1RA_Eng_A4(ai sorted).indd 22
EN-22
2017/07/07 11:43:22
SHARP CORPORATION
Malaysia SHARP ELECTRONICS (MALAYSIA) SDN. BHD. (356997-H)
No. 1A, Persiaran Kuala Langat, Section 27, 40400 Shah Alam, Selangor Darul
Ehsan, Malaysia.
Singapore Sharp Singapore Electronics Corporation Pte. Ltd.
438B Alexandra Road, #06-02, Alexandra Technopark, Singapore 119968
Indonesia PT.SHARP TRADING INDONESIA
Kawasan Industri KIIC, JI.Harapan Raya Lot LL1 & 2, Gedung No.01
Desa Sirnabaya, Kec.Teluk Jambe Timur, Kabupaten Karawang. 41361
Thailand
6/10 19-20
10120 http://www.sharpthai.co.th 0 2855 8899 0 2855 8500
0 2855 8888
Vietnam
Cty TNHH in T Sharp Vit Nam
9 inh Tiên Hoàng – Q.1 – Tp. H Chí Minh
TINSZA001VBRZ 17G-
EC-A1RA_Hyo_contens_A4 (ai sorted).indd 4
2017/07/07 14:39:45
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>